Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Diagnostics (Basel) ; 12(3)2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-35328265

RESUMO

The usefulness of opportunistic arrhythmia screening strategies, using an electrocardiogram (ECG) or other methods for random "snapshot" assessments is limited by the unexpected and occasional nature of arrhythmias, leading to a high rate of missed diagnosis. We have previously validated a cardiac monitoring system for AF detection pairing simple consumer-grade Bluetooth low-energy (BLE) heart rate (HR) sensors with a smartphone application (RITMIA™, Heart Sentinel srl, Italy). In the current study, we test a significant upgrade to the above-mentioned system, thanks to the technical capability of new HR sensors to run algorithms on the sensor itself and to acquire, and store on-board, single-lead ECG strips. We have reprogrammed an HR monitor intended for sports use (Movensense HR+) to run our proprietary RITMIA algorithm code in real-time, based on RR analysis, so that if any type of arrhythmia is detected, it triggers a brief retrospective recording of a single-lead ECG, providing tracings of the specific arrhythmia for later consultation. We report the initial data on the behavior, feasibility, and high diagnostic accuracy of this ultra-low weight customized device for standalone automatic arrhythmia detection and ECG recording, when several types of arrhythmias were simulated under different baseline conditions. Conclusions: The customized device was capable of detecting all types of simulated arrhythmias and correctly triggered a visually interpretable ECG tracing. Future human studies are needed to address real-life accuracy of this device.

3.
Diagnostics (Basel) ; 11(7)2021 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-34359312

RESUMO

Hypertrophic cardiomyopathy (HCM) and heterozygous familial hypercholesterolemia (HeFH), two of the most common genetic cardiovascular disorders, can lead to sudden cardiac death. These conditions could be complicated by concomitant severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection as in the case herein described. A young amateur soccer player died in late October 2020 after a fatal arrhythmia and the autopsy revealed the presence of HCM with diffuse non-obstructive coronary disease. The molecular autopsy revealed a compound condition with a first mutation in the MYH7 gene (p.Arg719Trp) and a second mutation in the LDLR gene (p.Gly343Cys): both have already been described as associated with HCM and HeFH, respectively. In addition, molecular analyses showed the presence of SARS-CoV-2 lineage B.1.1.7 (UK variant with high titer in the myocardium. Co-segregation analysis within the family (n = 19) showed that heterozygous LDLR mutation was maternally inherited, while the heterozygous MYH7 genetic lesion was de novo. All family member carriers of the LDLR mutation (n = 13) had systematic higher LDL plasma concentrations and positive records of cardiac and vascular ischemic events at young age. Considering that HCM mutations are in themselves involved in the predisposition to malignant arrhythmogenicity and HeFH could cause higher risk of cardiac complications in SARS-CoV-2 infection, this case could represent an example of a potential SARS-CoV-2 infection role in triggering or unmasking inherited cardiovascular disease, whose combination might represent the cause of fatal arrhythmia at such a young age. Additionally, it can provide clues in dating the presence of the SARS-CoV-2 lineage B.1.1.7 in Northern Italy in the early phases of the second pandemic wave.

5.
Biomed Res Int ; 2019: 4861951, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31355264

RESUMO

BACKGROUND: The RITMIA™ app (Heart Sentinel™, Parma, Italy) is a novel application that combined with a wearable consumer-grade chest-strap Bluetooth heart rate monitor, provides automated detection of atrial fibrillation (AF), and may be promising for sustainable AF screening programs, since it is known that prolonged monitoring leads to increased AF diagnosis. OBJECTIVE: The purpose of this study was to examine whether RITMIA™ could accurately differentiate sinus rhythm (SR) from AF compared with gold-standard physician-interpreted 12-lead electrocardiogram (ECG). DESIGN: In this observational prospective study consecutive patients presenting for elective cardioversion (ECV) of AF, from November 2017 to November 2018, were enrolled. Patients underwent paired 12-lead ECG and RITMIA™ recording, both before and after ECV procedure. The RITMIA™ automated interpretation was compared with 12-lead ECG interpreted by the agreement of two cardiologists. The latter were blinded to the results of the App automated diagnosis. Feasibility, sensitivity, specificity, and K coefficient for RITMIA™ automated diagnosis were calculated. RESULTS: A total of 100 consecutive patients were screened and enrolled. Five patients did not undergo ECV due to spontaneous restoration of SR. 95 patients who actually underwent ECV were included in the final analysis. Mean age was 66.2±10.7 years; female patients were 20 (21.1%). There were 190 paired ECGs and RITMIA™ recordings. The RITMIA™ app correctly detected AF with 97% sensitivity, 95.6% specificity, and a K coefficient of 0.93. CONCLUSIONS: The automated RITMIA™ algorithm very accurately differentiated AF from SR before and after elective ECV. The only hardware required by this method is a cheap consumer-grade Bluetooth heart rate monitor of the chest-strap type. This robust and affordable RITMIA™ technology could be used to conduct population-wide screening in patients at risk for silent AF, thanks to the long-term monitoring applicability.


Assuntos
Fibrilação Atrial , Cardioversão Elétrica , Aplicativos Móveis , Dispositivos Eletrônicos Vestíveis , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica
6.
Neuromodulation ; 22(2): 200-207, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30548106

RESUMO

OBJECTIVES: We present the results of a prospective, randomized, crossover, single-blind, study in which each patient is in control of himself. The aim was to evaluate subperception-based (SP-SCS) waveforms in previously implanted spinal cord stimulation (SCS) patients with leg and/or back pain due to failed back surgery syndrome, who experienced only paresthesia-based stimulation (PB-SCS). Patients with PB-SCS experience in SCS was 4.7 years (SD 2.9). MATERIALS AND METHODS: We enrolled 28 consecutive patients. Treatment consisted of seven days of PB-SCS, followed by a randomized, crossover phase to test SP-SCS waveforms (burst or 1 kHz frequency, seven days each). A maximum of three-day washout period separated each stimulation program. RESULTS: Statistically significant pain relief was maintained using both SP-SCS waveforms, as indicated by the differences between the pre-PB-SCS numeric pain rating score (mean 9) and the pain score after using the burst program (pain relief 52%) or the 1 kHz program (pain relief 51%). There was no statistically significant superiority among PB-SCS, burst, and 1 kHz stimulation. Overall, 50% of patients preferred PB-SCS, 42% chose to move to SP-SCS stimulation, one patient was unable to give feedback, and one patient was unsuccessful with any type of stimulation. Overall, SCS has shown to be successful in pain relief and the patients switched to a SP-SCS waveform only for having higher pain relief. CONCLUSIONS: There was a high heterogeneity regarding waveform preference, with patients who preferred to feel the tingling sensation and those who chose a SP-SCS option, mainly for greater pain relief. In general, SCS is successful, resulting in high pain relief, improvements in quality of life, and little depression. Overall, 42% patients benefited from the novel SP-SCS stimulation waveforms.


Assuntos
Dor nas Costas/psicologia , Dor nas Costas/terapia , Preferência do Paciente/psicologia , Estimulação da Medula Espinal/métodos , Estudos Cross-Over , Feminino , Humanos , Masculino , Medição da Dor , Estudos Prospectivos , Escalas de Graduação Psiquiátrica , Método Simples-Cego , Inquéritos e Questionários , Resultado do Tratamento
8.
J Echocardiogr ; 15(1): 18-26, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27589871

RESUMO

BACKGROUND: Accurate quantification of left ventricular (LV) volumes [end-diastolic volume (EDV) and end-systolic volume (ESV)] and ejection fraction (EF) is of critical importance. The development of real-time three-dimensional echocardiography (RT3DE) has shown better correlation than two-dimensional (2D) echocardiography with magnetic resonance imaging (MRI) measurements. The aim of our study was to assess the accuracy of RT3DE and 64-slice computed tomography (CT) in the evaluation of LV volumes and function using MRI as the reference standard in a real-world population with various types of heart disease with different chamber geometry. METHODS: The study population consisted of 66 patients referred for cardiac MRI for various pathologies. All patients underwent cardiac MRI, and RT3DE and 64 slices CT were then performed on a subsequent day. The study population was then divided into 5 clinical groups depending on the underlying heart disease. RESULTS: RT3DE volumes correlated well with MRI values (R 2 values: 0.90 for EDV and 0.94 for ESV). RT3DE measurements of EF correlated well with MRI values (R 2 = 0.86). RT3DE measurements resulted in slightly underestimated values of both EDV and ESV, as reflected by biases of -9.18 and -4.50 mL, respectively. Comparison of RT3DE and MRI in various types of cardiomyopathies showed no statistical difference between different LV geometrical patterns. CONCLUSION: These results confirm that RT3DE has good accuracy in everyday clinical practice and can be of clinical utility in all types of cardiomyopathy independently of LV geometric pattern, LV diameter or wall thickness, taking into account a slight underestimation of LV volumes and EF compared to MRI.


Assuntos
Ecocardiografia Tridimensional/métodos , Cardiopatias/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Cardiopatias/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Volume Sistólico
9.
Neuromodulation ; 20(4): 369-374, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27859948

RESUMO

INTRODUCTION: Assessing the feasibility, technical implications, and clinical benefits of peripheral nerve stimulation (PNS) performed by an implantable pulse generator (IPG) located close to the stimulation site. MATERIALS AND METHODS: Selected patients were affected by neuropathic pain associated with a documented peripheral nerve lesion, refractory to conventional surgical or pharmacological treatment. A PNS system specifically designed for peripheral placement (Neurimpulse, Padova, Italy) was implanted and followed for six months, recording the degree of patient's satisfaction (PGI-I questionnaire), the pain numerical rating scale (NRS) and the quality of life (SF36 questionnaire), as well as any change in drug regimen and work capability. The statistical significance of differences was determined by the paired Student's t-test. RESULTS: A total of 58 patients were referred to permanent IPG implantation. Stimulation failure due to lead damage or dislocation was noticed in two cases (3.4%) in six months. At the follow-up end, the relative NRS reduction averaged -58 ± 30% (p < 10-6 ) and was greater than 50% in 69% of the cases. Quality-of-life physical and mental indices were increased by 18% (p < 0.005) and 29% (p < 0.0005), respectively. The administration of antalgic drugs was stopped in 55% and reduced in 16% of the patients. Low-energy stimulation was possible in most cases, resulting in an IPG estimated life of 80 ± 35 months. CONCLUSIONS: Successful PNS was achieved with a stimulation system designed for peripheral location. This new technology reduced the incidence of lead-related adverse events and the energy cost of the treatment.


Assuntos
Dor Crônica/diagnóstico por imagem , Dor Crônica/terapia , Medição da Dor/métodos , Traumatismos dos Nervos Periféricos/diagnóstico por imagem , Traumatismos dos Nervos Periféricos/terapia , Estimulação Elétrica Nervosa Transcutânea/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Elétrica Nervosa Transcutânea/instrumentação , Resultado do Tratamento , Adulto Jovem
10.
Acta Biomed ; 87(2): 141-7, 2016 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-27648995

RESUMO

BACKGROUND AND AIM: Individuals with ischemia during cardiac stress-test (cST) have a high risk of developing myocardial infarction (MI), but the pathophysiologic mechanism has never been clarified. It is thought that non flow-limiting coronary plaques (FLP) cause more often MI than FLP, but this is in contradiction with the predictive value of cST. We investigated the correspondence between reversible ischemia and location of subsequent MI, since functional assessment shortly before MI could clarify whether the culprit plaque is a FLP or not. METHODS: From 4505 MI and 4959 cST -2017 contrast perfusion stress-echo (cDipSE) and 2942 scintigraphy (SPECT)- performed from 2007 to 2011- 25 patients fulfilling criteria (<3 months between cST and subsequent MI, angiography within 72 hours of symptoms onset and no revascularization between cST and MI) were extracted and data matched. Reversible perfusion defects were considered the endpoint to define a positive cST. RESULTS: Reversible perfusion defects on cST were found in 84% of patients (21/25) and 80% (20/25) had matched defects; 95% (20/21) of patients demonstrating a reversible defect had a subsequent MI in the same territory. CONCLUSION: Our data suggest that when cST-MI time is shortened, and plaque progression bias consequently minimized, most MI (80%) develop in the coronary territory where reversible perfusion defects were detected shortly before. These data encourage reconsidering FLP as main determinant of MI.


Assuntos
Ecocardiografia , Teste de Esforço , Infarto do Miocárdio/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Estenose das Carótidas/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Estudos Retrospectivos
11.
J Am Soc Echocardiogr ; 29(9): 899-906, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27448495

RESUMO

BACKGROUND: Real-time contrast stress echocardiography (RTCSE) permits the simultaneous analysis of myocardial perfusion and wall motion during stress echocardiography, which has resulted in improved coronary artery disease detection. Although several studies have confirmed a protective effect of obesity in coronary artery disease, it is unclear whether this benefit is dependent on the functional significance of the disease. The objective of this study was to compare outcomes in obese versus nonobese subjects referred for pharmacologic RTCSE. METHODS: A retrospective comparison of wall motion and myocardial perfusion with RTCSE was assessed in 481 obese and 961 nonobese patients matched for age and gender without known coronary artery disease referred for either dobutamine (n = 1,056) or dipyridamole (n = 386) stress echocardiography at two separate institutions. Outcomes (death or nonfatal infarction) were determined over a median follow-up period of 1,195 days. RESULTS: Abnormal myocardial perfusion and/or wall motion was seen in 207 (20%) dobutamine and 61 (16%) dipyridamole studies. Abnormal rates were similar in obese (17%) and nonobese (19%) subjects. Event-free survival was significantly worse only for nonobese subjects referred for dobutamine RTCSE, with obesity (not test result) being an independent predictor of event-free survival on multivariate analysis (P = .001). No protective effect of obesity was observed following dipyridamole RTCSE. CONCLUSIONS: Obese subjects in the United States referred for demand stress testing have better outcomes when directly compared with age- and gender-matched nonobese subjects with similar degrees of inducible ischemia.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Ecocardiografia sob Estresse/métodos , Obesidade/diagnóstico por imagem , Obesidade/mortalidade , Vasodilatadores/administração & dosagem , Distribuição por Idade , Idoso , Causalidade , Comorbidade , Dipiridamol/administração & dosagem , Dobutamina/administração & dosagem , Ecocardiografia sob Estresse/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/métodos , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Nebraska/epidemiologia , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade , Distribuição por Sexo , Taxa de Sobrevida
12.
Acta Biomed ; 87(1): 81-5, 2016 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-27163900

RESUMO

BACKGROUND AND AIM: According to the published data and guidelines the diagnosis of pericarditis is mainly clinical; if we exclude patients with pericardial effusion, no single study has been able to relate specific echocardiographic findings to acute pericarditis. We hypothesized that pericardial hyperechogenicity and a defined finding that we named "pericardial comets", in analogy to lung comets, may be associated with acute pericarditis. METHODS: We retrospectively analysed the echocardiograms of patients aged <50 y/o with a confirmed pericarditis diagnosis and compared them with 2 prospectively healthy controls groups (either < or > 50 y/o) to detect a potential association of pericardial hyperechogenicity and/or pericardial comets with acute pericarditis. RESULTS: Comparison between the pericarditis and the control groups did not evidence significant differences regarding the prevalence of hyperechogenicity and pericardial comets when comparing patients with pericarditis and age-matched controls (younger than 50 years); the group of elderly healthy controls (>50 y/o) showed significantly lower prevalence of pericardial hyperechogenicity (p<0.001) and comets (p<0.001), compared with the other 2 groups. A significantly higher number of patients with pericarditis demonstrated ≥2 pericardial comets compared with age-matched controls (68% vs 48%, p=0.042). CONCLUSION: The echocardiographic prevalence of both pericardial hyperechogenicity and comets per patient is heavily influenced by age (inversely proportional), but the presence of at least 2 pericardial comets is significantly more frequent in patients with pericarditis than in healthy aged-matched controls. Nonetheless, this echocardiographic finding may have limited clinical usefulness, due to the frequent detection of ≥2 comets in healthy young subjects also.


Assuntos
Ecocardiografia , Derrame Pericárdico/diagnóstico por imagem , Pericardite/diagnóstico por imagem , Doença Aguda , Adulto , Feminino , Humanos , Masculino , Estudos Retrospectivos
15.
Cardiovasc Ultrasound ; 12: 43, 2014 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-25352208

RESUMO

BACKGROUND: To test the hypothesis that a semi-quantitative echocardiographic calcium score (eCS) significantly correlates with cardiac calcium measured by coronary computed tomography angiography (CCTA) and, secondarily, severe coronary artery calcifications and stenosis. METHODS: This is a retrospective, observational study, conducted in a tertiary centre. eCS was compared with CCTA scores of non-coronary cardiac calcium (nCACS), coronary cardiac calcium (CACS) and number of diseased coronary vessels, in 141 subjects without known coronary artery disease (CAD), who underwent both echocardiography and CCTA for clinical reasons. RESULTS: Age, prevalence of hypertension and all measures of calcium (eCS, nCACS and CACS) differed significantly between the no-CAD and CAD subgroups. eCS was positively correlated with nCACS (Spearman rho = 0.64, p < 0.0001), CACS (rho = 0.46, p < 0.01) and weakly with the number of diseased coronary vessels (rho = 0.28, p < 0.05). eCS and nCACS had similar area under the curve (AUC) for the prediction of severe CACS (≥400) (0.77, 95% CI 0.68-0.86 and 0.79, 95% CI 0.72-0.88) or obstructive CAD (0.63, 95% CI 0.54-0.72 and 0.63, 95% CI 0.55-0.73). CONCLUSIONS: eCS, a calcium score easily obtainable during standard echocardiography, is moderately to strongly correlated with nCACS by CCTA. The full eCS score correlates with nCACS better than its single components. It correlates with CACS and predicts severe coronary calcification (CACS > 400), a known predictor of cardiovascular morbidity and mortality. The eCS also predicts obstructive CAD, incrementally to age and clinical variables, although for this purpose CACS remains the most accurate score.


Assuntos
Calcinose/complicações , Calcinose/diagnóstico , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/etiologia , Ecocardiografia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Tomografia Computadorizada Multidetectores/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto
17.
Neuromodulation ; 17(8): 777-83; discussion 783, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24528884

RESUMO

OBJECTIVE: We examined the efficacy of peripheral nerve stimulation (PNS) in treating neuropathic and causalgic pain, with a stimulation system specifically designated for PNS itself. MATERIALS AND METHODS: A total of 15 patients were treated between January 2011 and March 2012. The percutaneous lead was implanted on the nerves, exposing it on the electrical nerve stimulation (ENS) guide. The average numeric rating scale (NRS) preimplant was 8.46, and the oxycodone intake was 90 mg/day. RESULTS: Of the 15 patients, 3 failed the trial phase and 12 were implanted with a permanent pulse generator (Lightpulse 100, Neurimpulse, Rubano, PD, Italy). At an average of 9.3 months of follow-up, the average NRS score was 3.46 (p < 0.001), and the average Likert scale score at 7 points was 5.91. Nine patients were working prior to their injuries, seven of whom returned to work after receiving an implant. The average oxycodone consumption decreased to 30 mg/day, and the pregabalin dosage decreased to 75 mg/day. CONCLUSION: Our study results confirm that PNS is an effective modality in managing severe neuropathic and intractable pain following multiple joint surgeries that are complicated by causalgic pain.


Assuntos
Terapia por Estimulação Elétrica/métodos , Neuralgia/terapia , Nervos Periféricos/fisiologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor
18.
Echo Res Pract ; 1(1): K1-4, 2014 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-26693297

RESUMO

UNLABELLED: A 52-year-old man presented after one episode of effort angina, normal treadmill electrocardiogram (ECG), and clearly positive adenosine cardiac magnetic resonance (aCMR) for reversible perfusion defects in the left anterior descending (LAD) coronary artery territory. Contrast high-dose dipyridamole (0.84 mg/kg per 6 min) stress echocardiography (cSE) demonstrated normal myocardial perfusion (MP) and wall motion at rest, while perfusion defects were shown in the lateral and apical segments after dipyridamole. Wall motion at stress was completely normal and stress/rest Doppler diastolic velocity ratio on the LAD demonstrated reduced flow reserve. In this case, cSE was the provocative test detecting both the LAD and circumflex obstructive lesions, thanks to MP analysis, while wall motion assessment was negative, not different from treadmill ECG, and aCMR highlighted only the LAD disease. LEARNING POINTS: In spite of the low sensitivity of wall motion assessment during stress-echocardiography to detect coronary artery disease (CAD) in patients with multivessel disease and balanced ischemia, the addition of cSE with myocardial perfusion assessment, is not only able to overcome this limitation of false negative rate on a per-patient basis, but may also depict multivessel myocardial perfusion defects more efficiently than aCMR, as in the reported case, thanks to high spatial resolution.Myocardial perfusion assessment during cSE, although not always technically feasible, has a very high spatial and temporal resolution which can easily demonstrate multivessel subendocardial perfusion defects during maximal vasodilation, which is often the only detectable marker of multivessel, balanced CAD.It is known that wall motion analysis during pharmacologic stress may result in falsely negative multivessel disease; in these cases perfusion imaging or Doppler measurement of coronary flow reserve may be helpful to detect multivessel obstructive CAD, which is a significant and dismal prognostic finding. aCMR is assumed as the perfect imaging modality for CAD detection, but in selected cases, such as the one presented, an advanced echocardiographic method in experienced hands can provide even more comprehensive results.

19.
Echo Res Pract ; 1(2): 61-70, 2014 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26693302

RESUMO

Myocardium subtended by obstructive coronary artery disease (CAD) may show reduced left ventricle (LV) global longitudinal strain (GLS), as well as early systolic lengthening (ESL) before shortening; these can be measured at rest and may predict obstructive CAD. This study investigated whether baseline resting LV longitudinal strain measurements may be able to detect significant CAD in patients undergoing stress echocardiography (SE) and coronary angiography, who have normal resting wall motion. We selected patients with a clinical indication of coronary angiography who were previously referred for SE. Patients with known CAD, rest wall-motion (WM) abnormalities, or rhythm/conduction abnormalities were excluded. Speckle tracking strain analyses were retrospectively performed on digitally archived 2D video-loops, using vendor independent software. Peak GLS and duration of ESL were recorded. Diagnostic accuracy of each parameter to predict obstructive (≥50%) CAD was assessed and multivariate logistic regression models fitted and compared. Eighty-two patients were enrolled and 49 had significant CAD by quantitative angiography. Patients with CAD were more often male (P=0.01) and more frequently presented with typical angina (P<0.01). Among rest and stress variables, GLS showed a Youden index of 0.665, while SE WM assessment showed a Youden index of 0.599. These were the only two parameters that remained predictive in multivariate analyses. In conclusion, rest GLS demonstrated comparable accuracy with stress-echo data for prediction of angiographically obstructive CAD; it also added significant CAD prediction when combined with clinical data, similar to SE WM assessment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...