Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 92(2): 023503, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33648107

RESUMO

Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA Laser Facility. While the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (∼5 keV) and signal levels are low (by ∼20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils must be better characterized, and impact of uncontrolled foil motion prior to detection must be investigated.

2.
Rev Sci Instrum ; 89(11): 113508, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30501287

RESUMO

The next-generation Magnetic Recoil Spectrometer, called MRSt, will provide time-resolved measurements of the deuterium-tritium-neutron spectrum from inertial confinement fusion implosions at the National Ignition Facility. These measurements will provide critical information about the time evolution of the fuel assembly, hot-spot formation, and nuclear burn. The absolute neutron spectrum in the energy range of 12-16 MeV will be measured with high accuracy (∼5%), unprecedented energy resolution (∼100 keV) and, for the first time ever, time resolution (∼20 ps). Crucial to the design of the system is a CD conversion foil for the production of recoil deuterons positioned as close to the implosion as possible. The foil-on-hohlraum technique has been demonstrated by placing a 1-mm-diameter, 40-µm-thick CD foil on the hohlraum diagnostic band along the line-of-sight of the current time-integrated MRS system, which measured the recoil deuterons. In addition to providing validation of the foil-on-hohlraum technique for the MRSt design, substantial improvement of the MRS energy resolution has been demonstrated.

3.
Rev Sci Instrum ; 87(11): 11D816, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910455

RESUMO

The Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility measures the DT neutron spectrum from cryogenically layered inertial confinement fusion implosions. Yield, areal density, apparent ion temperature, and directional fluid flow are inferred from the MRS data. This paper describes recent advances in MRS measurements of the primary peak using new, thinner, reduced-area deuterated plastic (CD) conversion foils. The new foils allow operation of MRS at yields 2 orders of magnitude higher than previously possible, at a resolution down to ∼200 keV FWHM.

4.
Magn Reson Med ; 39(4): 596-605, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9543422

RESUMO

When a linear magnetic field gradient is used, spatially higher-order magnetic fields are produced to satisfy the Maxwell equations. It has been observed that the higher-order magnetic field produced by the readout gradient causes axial echo planar images acquired with a horizontal solenoid magnet to shift along the phase-encoding direction and lose image intensities. Both the shift and intensity reduction become increasingly severe as the slice offset from the isocenter increases. These phenomena are quantitatively analyzed, and good correlation between experiments and theory has been established. The analysis also predicts a previously unreported Nyquist ghost on images with very large slice offsets. This ghost has been verified with computer simulations. Based on the analysis, several methods have been developed to eliminate the image shift, the intensity reduction, and the ghost. Selected methods have been implemented on a commercial scanner and proved effective in removing these image artifacts.


Assuntos
Artefatos , Imagem Ecoplanar/métodos , Magnetismo , Encéfalo/anatomia & histologia , Simulação por Computador , Humanos , Matemática , Modelos Estruturais , Imagens de Fantasmas , Valor Preditivo dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...