Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Appl Crystallogr ; 57(Pt 3): 690-699, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38846768

RESUMO

Scintillator-based ZnS:Ag/6LiF neutron detectors have been under development at ISIS for more than three decades. Continuous research and development aim to improve detector capabilities, achieve better performance and meet the increasingly demanding requirements set by neutron instruments. As part of this program, a high-efficiency 2D position-sensitive scintillator detector with wavelength-shifting fibres has been developed for neutron-diffraction applications. The detector consists of a double scintillator-fibre layer to improve detection efficiency. Each layer is made up of two orthogonal fibre planes placed between two ZnS:Ag/6LiF scintillator screens. Thin reflective foils are attached to the front and back scintillators of each layer to minimize light cross-talk between layers. The detector has an active area of 192 × 192 mm with a square pixel size of 3 × 3 mm. As part of the development process of the double-layer detector, a single-layer detector was built, together with a prototype detector in which the two layers of the detector could be read out separately. Efficiency calculations and measurements of all three detectors are discussed. The novel double-layer detector has been installed and tested on the SXD diffractometer at ISIS. The detector performance is compared with the current scintillator detectors employed on SXD by studying reference crystal samples. More than a factor of 3 improvement in efficiency is achieved with the double-layer wavelength-shifting-fibre detector. Software routines for further optimizations in spatial resolution and uniformity of response have been implemented and tested for 2D detectors. The methods and results are discussed in this manuscript.

2.
Int J Antimicrob Agents ; 53(1): 95-97, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30315921

RESUMO

The quantitative importance of active antimicrobial treatment relative to other modifiable and non-modifiable risk factors for mortality has not been well defined in the literature. Here we quantify the impact of active antimicrobial treatment on mortality relative to other disease modifiers in patients with Gram-negative bloodstream infection (GNBSI). Patients with at least one positive blood culture who were treated with ≥24 h of cefepime for GNBSI were included in the study. To examine in-hospital survival, a full primary model and a base model with the least significant covariate from the primary model were established. Relative importance of covariates was calculated using percentages of difference in log-likelihood values when each covariate was iteratively added to the base model. A total of 154 unique patients with GNBSI were included. The primary model included active cefepime therapy (P = 0.004), normalised days to positive culture (P = 0.091), intensive care unit (ICU) at time of treatment (P = 0.001), modified Acute Physiology and Chronic Health Evaluation (APACHE) II score on day zero (P = 0.025), history of leukaemia (P = 0.008) and prior immunosuppressive therapy (P = 0.088). Active antimicrobial therapy displayed a relative importance of 32.2%, which was second to ICU residence at the time of culture. Amongst all covariates in the model, active antimicrobial therapy was the only modifiable variable and contributed significantly to in-hospital survival in acutely ill patients with GNBSI.


Assuntos
Antibacterianos/uso terapêutico , Bacteriemia/tratamento farmacológico , Bacteriemia/microbiologia , Cefepima/uso terapêutico , Infecções por Bactérias Gram-Negativas/tratamento farmacológico , Adulto , Idoso , Feminino , Bactérias Gram-Negativas/efeitos dos fármacos , Infecções por Bactérias Gram-Negativas/microbiologia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco
3.
Clin Transl Sci ; 10(6): 496-502, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28675684

RESUMO

A translational need exists to understand and predict vancomycin-induced kidney toxicity. We describe: (i) a vancomycin high-performance liquid chromatography (HPLC) method for rat plasma and kidney tissue homogenate; (ii) a rat pharmacokinetic (PK) study to demonstrate utility; and (iii) a catheter retention study to enable future preclinical studies. Rat plasma and pup kidney tissue homogenate were analyzed via HPLC for vancomycin concentrations ranging from 3-75 and 15.1-75.5 µg/mL, respectively, using a Kinetex Biphenyl column and gradient elution of water with 0.1% formic acid: acetonitrile (70:30 v/v). Sprague-Dawley rats (n = 10) receiving 150 mg/kg of vancomycin intraperitoneally had plasma sampled for PK. Finally, a catheter retention study was performed on polyurethane catheters to assess adsorption. Precision was <6.1% for all intra-assay and interassay HPLC measurements, with >96.3% analyte recovery. A two-compartment model fit the data well, facilitating PK exposure estimates. Finally, vancomycin was heterogeneously retained by polyurethane catheters.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Testes de Toxicidade , Vancomicina/farmacocinética , Vancomicina/toxicidade , Animais , Teorema de Bayes , Bioensaio , Cateterismo , Rim/metabolismo , Masculino , Ratos Sprague-Dawley , Extratos de Tecidos , Vancomicina/sangue
4.
J Clin Pharm Ther ; 42(3): 350-355, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28370067

RESUMO

WHAT IS KNOWN AND OBJECTIVE: Neurotoxicity is a side effect of acyclovir. We report the first case, to our knowledge, whereby Bayesian-informed clearance estimates supported a therapeutic intervention for acyclovir-associated neurotoxicity. CASE SUMMARY: A 62-year-old male with the diagnosis of disseminated zoster was being treated with intravenous (IV) acyclovir when he developed symptoms of acute neurotoxicity. Acyclovir had been dose-adjusted for renal dysfunction according to traditional creatinine clearance estimates; however, as the patient was also on vancomycin, Bayesian estimates of vancomycin clearances were performed, which revealed a 2-fold lower creatinine clearance. In response to the Bayesian estimates, acyclovir was discontinued, and improvements in mentation were noted within 24 hours. WHAT IS NEW AND CONCLUSION: Alternate approaches to estimate renal function beyond Cockcroft-Gault, such as a Bayesian approach used in our patient, should be considered when population estimates are likely to be inaccurate and potentially dangerous to the patient.


Assuntos
Aciclovir/efeitos adversos , Antivirais/efeitos adversos , Síndromes Neurotóxicas/etiologia , Aciclovir/administração & dosagem , Antivirais/administração & dosagem , Teorema de Bayes , Creatinina/análise , Relação Dose-Resposta a Droga , Herpes Zoster/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Síndromes Neurotóxicas/diagnóstico , Vancomicina/administração & dosagem , Vancomicina/farmacocinética
5.
Rep Prog Phys ; 79(9): 094301, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27502571

RESUMO

Neutron scattering techniques are attracting an increasing interest from scientists in various research fields, ranging from physics and chemistry to biology and archaeometry. The success of these neutron scattering applications is stimulated by the development of higher performance instrumentation. The development of new techniques and concepts, including radiative capture based neutron detection, is therefore a key issue to be addressed. Radiative capture based neutron detectors utilize the emission of prompt gamma rays after neutron absorption in a suitable isotope and the detection of those gammas by a photon counter. They can be used as simple counters in the thermal region and (simultaneously) as energy selector and counters for neutrons in the eV energy region. Several years of extensive development have made eV neutron spectrometers operating in the so-called resonance detector spectrometer (RDS) configuration outperform their conventional counterparts. In fact, the VESUVIO spectrometer, a flagship instrument at ISIS serving a continuous user programme for eV inelastic neutron spectroscopy measurements, is operating in the RDS configuration since 2007. In this review, we discuss the physical mechanism underlying the RDS configuration and the development of associated instrumentation. A few successful neutron scattering experiments that utilize the radiative capture counting techniques will be presented together with the potential of this technique for thermal neutron diffraction measurements. We also outline possible improvements and future perspectives for radiative capture based neutron detectors in neutron scattering application at pulsed neutron sources.

6.
Rev Sci Instrum ; 82(7): 073904, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21806196

RESUMO

The high magnetic field (HiFi) muon instrument at the ISIS pulsed neutron and muon source is a state-of-the-art spectrometer designed to provide applied magnetic fields up to 5 T for muon studies of condensed matter and molecular systems. The spectrometer is optimised for time-differential muon spin relaxation studies at a pulsed muon source. We describe the challenges involved in its design and construction, detailing, in particular, the magnet and detector performance. Commissioning experiments have been conducted and the results are presented to demonstrate the scientific capabilities of the new instrument.

7.
Rev Sci Instrum ; 81(3): 033905, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20370190

RESUMO

NIMROD is the Near and InterMediate Range Order Diffractometer of the ISIS second target station. Its design is optimized for structural studies of disordered materials and liquids on a continuous length scale that extends from the atomic, upward of 30 nm, while maintaining subatomic distance resolution. This capability is achieved by matching a low and wider angle array of high efficiency neutron scintillation detectors to the broad band-pass radiation delivered by a hybrid liquid water and liquid hydrogen neutron moderator assembly. The capabilities of the instrument bridge the gap between conventional small angle neutron scattering and wide angle diffraction through the use of a common calibration procedure for the entire length scale. This allows the instrument to obtain information on nanoscale systems and processes that are quantitatively linked to the local atomic and molecular order of the materials under investigation.

8.
Nature ; 301(5900): 535-7, 1983 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-6823334

RESUMO

The synthetic polynucleotide poly[d(AT)].poly[d(AT)] is of interest in studies of the relationship between nucleic acid structure and function. In particular, A + T-rich regions in DNA double helices have been invoked as centres for controlling the transcription of genetic information. Here we describe conditions for observing by X-ray fibre diffraction the A, B, C and D conformations of Na-poly[d(AT)].poly[d(AT)], and for inducing transitions between these conformations. The D form emerges as a particularly stable conformation; once assumed, it persists over a wide range of variation in the relative humidity of the fibre environment. Further, while transitions between the B and D conformations are readily reversible, transitions between A and D are much more complex.


Assuntos
Conformação de Ácido Nucleico , Poli dA-dT , Polidesoxirribonucleotídeos , Sódio , Relação Estrutura-Atividade , Água , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA