Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Colloids Surf B Biointerfaces ; 177: 204-210, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30743067

RESUMO

Dispersed systems of bicontinuous cubic phases, called cubosomes, show a drug release rate faster than those obtained using other liquid-crystalline phases. To minimize side effects associated with the accelerated release of incorporated drugs, compounds may be added in the dispersions to produce systems of slow initial release and then fast release only in the desired action region. This paper addresses the addition of 10.0% (w/w) of decyl betainate chloride (DBC), a cleavable surfactant, into phytantriol/Pluronic-based dispersions to generate lamellar-to-cubic-to-hexagonal phase transitions. Small-angle X-ray scattering (SAXS) was used to analyze the mesophases obtained with the addition of DBC and pH variation. Transmission electron microscopy (TEM) images confirmed the presence of niosomes after the addition of DBC. The niosomes formed in these systems are pH-responsive with lamellar-to-hexosomes transitions at pH ≥ 7.4. The system investigated herein is gastro-resistant presenting potential therapeutic role for controlled release of drugs in neutral or alkaline environments of the organism.


Assuntos
Álcoois Graxos/química , Nanopartículas/química , Concentração de Íons de Hidrogênio , Estrutura Molecular , Tamanho da Partícula , Transição de Fase , Propriedades de Superfície , Tensoativos/química
2.
Anal Chem ; 90(21): 12377-12384, 2018 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-30222327

RESUMO

This technical note describes a new microfluidic sensor that combines low-cost (USD $0.97) with rapid fabrication and user-friendly, fast, sensitive, and accurate quantification of a breast cancer biomarker. The electrodes consisted of cost-effective bare stainless-steel capillaries, whose mass production is already well-established. These capillaries were used as received, without any surface modification. Microfluidic chips containing electrical double-layer capillary capacitors (µEDLC) were obtained by a cleanroom-free prototyping that allows the fabrication of dozens to hundreds of chips in 1 h. This sensor provided the successful quantification of CA 15-3, a biomarker protein for breast cancer, in serum samples from cancer patients. Antibody-anchored magnetic beads were utilized for immunocapture of the marker, and then, water was added to dilute the protein. Next, the CA 15-3 detection (<2 min) was made without using redox probes, antibody on electrode (sandwich immunoassay), or signal amplification strategies. In addition, the capacitance tests eliminated external pumping systems and precise volumetric sampling steps, as well as presented low sample volume (5 µL) and high sensitivity using bare capillaries in a new design for double-layer capacitors. The achieved limit-of-detection (92.0 µU mL-1) is lower than that of most methods reported in the literature for CA 15-3, which are based on nanostructured electrodes. The data shown in this technical note support the potential of the µEDLC toward breast cancer diagnosis even at early stages. We believe that accurate analyses using a simple sample pretreatment such as magnetic field-assisted immunocapture and cost-effective bare electrodes can be extended to quantify other cancer biomarkers and even biomolecules by changing the biorecognition element.


Assuntos
Biomarcadores Tumorais/análise , Técnicas Biossensoriais/economia , Neoplasias da Mama/diagnóstico por imagem , Técnicas Eletroquímicas/economia , Técnicas Analíticas Microfluídicas/economia , Mucina-1/análise , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , Eletrodos , Feminino , Humanos , Técnicas Analíticas Microfluídicas/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...