Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Ophthalmology ; 127(2): 186-195, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31474439

RESUMO

PURPOSE: Geographic atrophy (GA), a late stage of age-related macular degeneration (AMD), is a major cause of blindness. Even while central visual acuity remains relatively well preserved, GA often causes considerable compromise of visual function and quality of life. No treatment currently exists. We evaluated the safety and efficacy of pegcetacoplan, a complement C3 inhibitor, for treatment of GA. DESIGN: Prospective, multicenter, randomized, sham-controlled phase 2 study. PARTICIPANTS: Two hundred forty-six patients with GA. METHODS: Patients with GA were assigned randomly in a 2:2:1:1 ratio to receive intravitreal injections of 15 mg pegcetacoplan monthly or every other month (EOM) or sham intravitreal injections monthly or EOM for 12 months with follow-up at months 15 and 18. Area and growth of GA were measured using fundus autofluorescence imaging. MAIN OUTCOME MEASURES: The primary efficacy end point was mean change in square root GA lesion area from baseline to month 12. Secondary outcome measures included mean change from baseline in GA lesion area without the square root transformation, distance of GA lesion from the fovea, best-corrected visual acuity (BCVA), low-luminance BCVA, and low-luminance visual acuity deficit. The primary safety end point was the number and severity of treatment-emergent adverse events. RESULTS: In patients receiving pegcetacoplan monthly or EOM, the GA growth rate was reduced by 29% (95% confidence interval [CI], 9-49; P = 0.008) and 20% (95% CI, 0-40; P = 0.067) compared with the sham treatment group. Post hoc analysis showed that the effect was greater in the second 6 months of treatment, with observed reductions of 45% (P = 0.0004) and 33% (P = 0.009) for pegcetacoplan monthly and EOM, respectively. Two cases of culture-positive endophthalmitis and 1 case of culture-negative endophthalmitis occurred in the pegcetacoplan monthly group. New-onset investigator-determined exudative AMD was reported more frequently in pegcetacoplan-treated eyes (18/86 eyes [20.9%] and 7/79 eyes [8.9%] in monthly and EOM groups, respectively) than in sham-treated eyes (1/81 eyes [1.2%]). CONCLUSIONS: Local C3 inhibition with pegcetacoplan resulted in statistically significant reductions in the growth of GA compared with sham treatment. Phase 3 studies will define the efficacy and safety profile further.


Assuntos
Complemento C3/antagonistas & inibidores , Inativadores do Complemento/uso terapêutico , Atrofia Geográfica/tratamento farmacológico , Degeneração Macular/complicações , Idoso , Idoso de 80 Anos ou mais , Feminino , Angiofluoresceinografia , Atrofia Geográfica/diagnóstico , Atrofia Geográfica/etiologia , Humanos , Injeções Intravítreas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia
3.
Artigo em Inglês | MEDLINE | ID: mdl-23883533

RESUMO

BACKGROUND AND OBJECTIVE: To investigate whether the confocal near-infrared reflectance (NIR) imaging modality could detect the in vivo presence of retinal pigment epithelium cells derived from embryonic human stem cells (hESC-RPE) implanted into the subretinal space of the Royal College of Surgeons (RCS) rat. MATERIALS AND METHODS: Monthly NIR images were obtained from RCS rats implanted with either hESC-RPE seeded on a parylene membrane (n = 14) or parylene membrane without cells (n = 14). Two independent, masked investigators graded the images. Histology and immunohistochemistry were performed at different time points (150, 210, and 270 postnatal days of age). RESULTS: NIR images revealed that an average of 20.53% of the parylene membrane area was covered by hESC-RPE. RPE-65 and TRA-1-85 confirmed the presence of human-specific RPE cells in those animals. No areas corresponding to cells were found in the group implanted with membrane only. Intergrader agreement was high (r = 0.89-0.92). CONCLUSION: The NIR mode was suitable to detect the presence of hESC-RPE seeded on a membrane and implanted into the subretinal space of the RCS rat.


Assuntos
Células-Tronco Embrionárias/transplante , Células Epiteliais/transplante , Oftalmoscopia , Descolamento Retiniano/cirurgia , Epitélio Pigmentado da Retina/citologia , Transplante de Células-Tronco/métodos , Animais , Células Cultivadas , Modelos Animais de Doenças , Células-Tronco Embrionárias/citologia , Humanos , Imuno-Histoquímica , Ratos , Retina/patologia , Retina/cirurgia , Descolamento Retiniano/patologia , Espectroscopia de Luz Próxima ao Infravermelho
4.
Retina ; 33(5): 928-32, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23416511

RESUMO

PURPOSE: To evaluate flow rates and duty cycle for different sizes of ultra-high-speed pneumatic vitreous cutters. METHODS: A precision balance measured the mass of water and vitreous removed from a vial. Porcine vitreous was obtained within 12 hours of killed at a local slaughterhouse and kept at 4 °C. Twenty-, 23- and 25-gauge (n = 3 of each gauge) pneumatic cutters were tested at 0 (water), 1,000, 2,000, 3,000, 4,000, and 5,000 cuts per minute with aspiration levels of 100, 200, 300, 400, 500, and 600 mmHg. Frame-by-frame analysis of high-speed video was used to determine the duty cycle. RESULTS: Larger gauge cutters associated with higher aspiration levels produced greater vitreous and water flow rates (P < 0.05). As the cut rate increased, the vitreous flow rate increased (maximum flow at 5,000 cuts per minute) and the water flow rate decreased (P < 0.05). The duty cycle of the new-generation cutters decreased as cut speeds increased, using all 3 gauges (P < 0.001). Vitreous flow rates averaged 10 times less than water flow rates using the same cutter at the same settings. CONCLUSION: Ultra-high-speed vitreous cutters produce consistent vitreous and water flow rates across the tested range of cuts per minute and aspiration levels.


Assuntos
Microcirurgia/métodos , Vitrectomia/instrumentação , Corpo Vítreo/cirurgia , Animais , Desenho de Equipamento , Pressão , Suínos , Gravação em Vídeo , Água
5.
Retina ; 33(5): 933-8, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23416512

RESUMO

PURPOSE: The purpose of the study was to determine the performance of dual pneumatic ultra high-speed 23-gauge cutters operated with variable duty cycle (DC) settings. METHODS: Frame-by-frame analysis of high-speed video was used to determine the DC in core, 50-50, and shave modes. Using three cutters at various cycles per minute and aspiration levels, mass of water or vitreous removed from a vial was measured within a specified time period. Average flow rates were calculated for each aspiration level and cut rate with the different DC options. RESULTS: The DC increased with increasing cut rate in the shave mode was relatively stable in the 50-50 mode and decreased for the core mode. The DC converged at 5,000 cycles per minute for the 3 different modes. Water flow curves followed the DC variation. Vitreous flow rates for all the DC modes increased with increasing cut rates and peaked at 5,000 cycles per minute (P < 0.05). The results of the 50-50 mode, which had isolated the DC influence, showed that increasing aspiration and/or cut rate independently increased the vitreous flow rate. CONCLUSION: Progressive values of aspiration and/or cut rate increase the vitreous flow rate, independently of the DC. The DC control also has an important effect on the vitreous flow, but this effect was reduced at high cut rates because of convergence of the DC modes.


Assuntos
Microcirurgia/métodos , Vitrectomia/instrumentação , Corpo Vítreo/cirurgia , Animais , Suínos , Gravação em Vídeo , Água
6.
Ophthalmologica ; 229(1): 15-20, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23108417

RESUMO

BACKGROUND: Dual pneumatic systems use two separate air line tubes to open and close the cutter and can achieve high cut rates. The purpose of this study is to evaluate the influence of gauge size, cut rate and aspiration on the flow rate performance of ultra high-speed cutters operated with a commercially available dual pneumatic vitrectomy system. METHODS: Analysis of a high-speed video was used to determine duty cycle. Flow rates from 20-, 23- and 25-gauge cutters were calculated in predetermined conditions of aspiration levels and cut rates; water and fresh porcine vitreous samples were studied. RESULTS: For all three gauges of cutters, the duty cycle and water flow showed an inverse correlation with increasing cut rates and a direct correlation with increasing aspiration levels (p < 0.05). Vitreous flow rates from all gauges increased with increasing aspiration and cut rates (p < 0.05). CONCLUSION: Larger gauges of the cutters as well as higher aspiration and cut rate levels resulted in improvement of the vitreous flow rates. A good understanding of the different flow rate settings is essential for the surgeon and optimizes the safety of surgical procedures.


Assuntos
Microcirurgia/métodos , Vitrectomia/instrumentação , Corpo Vítreo/cirurgia , Animais , Desenho de Equipamento , Pressão , Suínos , Gravação em Vídeo , Água
7.
Br J Ophthalmol ; 97(3): 285-90, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23264545

RESUMO

AIM: To evaluate the efficiency of drusen detection by scanning laser ophthalmoscopy (SLO) using various infrared confocal apertures and differential contrast (DC) strategies. METHODS: 11 eyes with non-neovascular age-related macular degeneration (AMD) underwent infrared imaging with a Nidek F-10 confocal SLO using multiple confocal apertures: central, ring, aperture on the right side (AR) and left side (AL), with and without use of the DC. A conventional colour fundus photograph was also obtained. Images were exported into a certified grading tool and all visible drusen were manually outlined by two graders. For each image type, the number of drusen and total drusen area were calculated, and the measurements obtained by the two graders were averaged. Intergrader reliability was evaluated, and paired t tests compared measurements between the various aperture/DC modes and the colour image. RESULTS: Agreement between graders was high (r=0.93-0.98). Drusen number values obtained with the AR (121.0, p=0.01) mode were higher than for the colour photographs (69.1). Area measurements were also significantly higher in the AR (1.93 mm(2); p=0.04) and AL modes (1.41 mm(2); p=0.03) when compared with the colour photographs (1.24 mm(2)). The addition of the DC did not seem to improve drusen detection compared with the unmodified infrared images. CONCLUSIONS: In this pilot study, drusen number and area grades were significantly higher using the AR and AL in which the laterally scattered light is captured (retromode). Use of the lateral confocal aperture may highlight subclinical drusen and aid in monitoring disease progression and response to emerging non-neovascular AMD therapies.


Assuntos
Lasers , Oftalmoscopia/métodos , Retina/patologia , Drusas Retinianas/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...