1.
Appl Environ Microbiol ; 71(10): 5805-13, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16204491

RESUMO

A cross-sectional multicenter survey of Italian hotels was conducted to investigate Legionella spp. contamination of hot water. Chemical parameters (hardness, free chlorine concentration, and trace element concentrations), water systems, and building characteristics were evaluated to study risk factors for colonization. The hot water systems of Italian hotels were strongly colonized by Legionella; 75% of the buildings examined and 60% of the water samples were contaminated, mainly at levels of > or =10(3) CFU liter(-1), and Legionella pneumophila was the most frequently isolated species (87%). L. pneumophila serogroup 1 was isolated from 45.8% of the contaminated sites and from 32.5% of the hotels examined. When a multivariate logistic model was used, only hotel age was associated with contamination, but the risk factors differed depending on the contaminating species and serogroup. Soft water with higher chlorine levels and higher temperatures were associated with L. pneumophila serogroup 1 colonization, whereas the opposite was observed for serogroups 2 to 14. In conclusion, Italian hotels, particularly those located in old buildings, represent a major source of risk for Legionnaires' disease due to the high frequency of Legionella contamination, high germ concentration, and major L. pneumophila serogroup 1 colonization. The possible role of chlorine in favoring the survival of Legionella species is discussed.


Assuntos
Água Doce/microbiologia , Temperatura Alta , Legionella/isolamento & purificação , Viagem , Poluição da Água , Abastecimento de Água , Contagem de Colônia Microbiana , Água Doce/química , Itália , Legionella/classificação , Legionella/genética , Legionella pneumophila/classificação , Legionella pneumophila/genética , Legionella pneumophila/isolamento & purificação , Análise de Regressão , Sorotipagem
2.
Emerg Infect Dis ; 10(3): 457-64, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15109413

RESUMO

We investigated Legionella and Pseudomonas contamination of hot water in a cross-sectional multicentric survey in Italy. Chemical parameters (hardness, free chlorine, and trace elements) were determined. Legionella spp. were detected in 33 (22.6%) and Pseudomonas spp. in 56 (38.4%) of 146 samples. Some factors associated with Legionella contamination were heater type, tank distance and capacity, water plant age, and mineral content. Pseudomonas presence was influenced by water source, hardness, free chlorine, and temperature. Legionella contamination was associated with a centralized heater, distance from the heater point >10 m, and a water plant >10 years old. Furthermore, zinc levels of <100 microg/L and copper levels of >50 microg/L appeared to be protective against Legionella colonization [corrected]. Legionella species and serogroups were differently distributed according to heater type, water temperature, and free chlorine, suggesting that Legionella strains may have a different sensibility and resistance to environmental factors and different ecologic niches.


Assuntos
Legionella pneumophila/isolamento & purificação , Legionella/isolamento & purificação , Legionelose/etiologia , Doença dos Legionários/etiologia , Metais/análise , Pseudomonas/isolamento & purificação , Abastecimento de Água/análise , Humanos , Itália , Fatores de Risco , Microbiologia da Água