Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Vasc Interv Radiol ; 25(1): 127-32, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24262033

RESUMO

PURPOSE: To evaluate therapeutic lymphangiography and computed tomography (CT)-guided sclerotherapy for the treatment of refractory inguinal, pelvic, abdominal, and thoracic lymphatic leakage. MATERIALS AND METHODS: Between January 2008 and April 2011, 18 patients with refractory lymphatic leakage were treated with therapeutic lymphangiography. Additionally, 10 of these 18 patients underwent CT-guided sclerotherapy with injection of ethanol at the site of the leakage. In the delayed sclerotherapy group (n = 5), the sclerotherapy procedure was performed when the leak persisted after therapeutic lymphangiography. In the immediate sclerotherapy group (n = 5), sclerotherapy was performed on the same day as lymphangiography. The sites of the lymphatic leakage were as follows: inguinal leakage in 8 patients, pelvic leakage in 4 patients, abdominal leakage in 2 patients, and thoracic leakage in 4 patients. Data collected included technical success, clinical success, and procedural complications. RESULTS: Lymphangiography was technically successful in all patients. In eight patients undergoing therapeutic lymphangiography alone, the clinical success rate was 75%, and the drainage catheter could be removed in six patients after the treatment. Lymphangiography followed by immediate sclerotherapy was clinically successful in four of five patients. Lymphangiography combined with delayed sclerotherapy was clinically successful in three of five patients. Overall, the clinical success rate was 72% (13 of 18 patients). One minor complication occurred. CONCLUSIONS: Therapeutic lymphangiography alone or in combination with CT-guided sclerotherapy is a promising treatment option for the management of refractory lymphatic leakage.


Assuntos
Doenças Linfáticas/terapia , Linfografia , Radiografia Intervencionista/métodos , Escleroterapia , Tomografia Computadorizada por Raios X , Adulto , Idoso , Terapia Combinada , Meios de Contraste/administração & dosagem , Drenagem , Etanol/administração & dosagem , Óleo Etiodado/administração & dosagem , Feminino , Humanos , Injeções , Doenças Linfáticas/diagnóstico , Doenças Linfáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Soluções Esclerosantes/administração & dosagem , Escleroterapia/métodos , Fatores de Tempo , Resultado do Tratamento
2.
J Vasc Interv Radiol ; 23(3): 331-7, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22289473

RESUMO

PURPOSE: To evaluate the efficacy and safety of balloon-expandable stent grafts in the emergency treatment of acute arterial hemorrhage. MATERIALS AND METHODS: Between July 2008 and December 2009, 15 patients with acute arterial hemorrhage from inflammatory vessel erosion or pseudoaneurysms (n = 9), noninflammatory pseudoaneurysms (n = 3), or iatrogenic vessel injury (n = 3) were treated with emergency stent graft implants. The primary study endpoints to determine treatment efficacy and safety were survival, complication rates, and freedom from recurrent hemorrhaging or reintervention. The secondary study endpoints were technical and clinical success. RESULTS: The survival rate was 73% with a mean follow-up of 119 days ± 220. The complication rate was 20%. The procedure was technically successful in 13 of 15 (87%) patients. One endoleak persisted and led to a reintervention rate of 7%. The bleeding ceased immediately after stent graft implantation in 14 patients. CONCLUSIONS: Implantation of balloon-expandable stent grafts is a safe and effective emergency treatment for acute arterial hemorrhage from visceral and peripheral vessels.


Assuntos
Falso Aneurisma/cirurgia , Oclusão com Balão/instrumentação , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Hemorragia/cirurgia , Doença Iatrogênica , Stents , Lesões do Sistema Vascular/cirurgia , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Falso Aneurisma/complicações , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/mortalidade , Artérias/lesões , Artérias/cirurgia , Oclusão com Balão/efeitos adversos , Oclusão com Balão/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Endoleak/etiologia , Endoleak/cirurgia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Alemanha , Hemorragia/diagnóstico por imagem , Hemorragia/etiologia , Hemorragia/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Reoperação , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Lesões do Sistema Vascular/complicações , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/mortalidade
3.
World J Gastroenterol ; 17(9): 1126-34, 2011 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-21448416

RESUMO

AIM: To investigate predilection sites of recurrence of pancreatic cancer by computed tomography (CT) in follow-up after surgery. METHODS: Seventy seven patients with recurrence after pancreatic cancer surgery were retrospectively identified. The operative technique, R-status, T-stage and development of tumor markers were evaluated. Two radiologists analyzed CT scans with consensus readings. Location of local recurrence, lymph node recurrence and organ metastases were noted. Surgery and progression of findings on follow-up CT were considered as reference standard. RESULTS: The mean follow-up interval was 3.9 ± 1.8 mo, with a mean relapse-free interval of 12.9 ± 10.4 mo. The predominant site of recurrence was local (65%), followed by lymph node (17%), liver metastasis (11%) and peritoneal carcinosis (7%). Local recurrence emerged at the superior mesenteric artery (n = 28), the hepatic artery (n = 8), in an area defined by the surrounding vessels: celiac trunk, portal vein, inferior vena cava (n = 22), and in a space limited by the mesenteric artery, portal vein and inferior vena cava (n = 17). Lymph node recurrence occurred in the mesenteric root and left lateral to the aorta. Recurrence was confirmed by surgery (n = 22) and follow-up CT (n = 55). Tumor markers [carbohydrate antigen 19-9 (CA19-9), carcinoembryonic antigen (CEA)] increased in accordance with signs of recurrence in most cases (86% CA19-9; 79.2% CEA). CONCLUSION: Specific changes of local and lymph node recurrence can be found in the course of the cardinal peripancreatic vessels. The superior mesenteric artery is the leading structure for recurrence.


Assuntos
Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas/prevenção & controle , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/metabolismo , Feminino , Humanos , Linfonodos/patologia , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/cirurgia , Neoplasias Pancreáticas/cirurgia , Recidiva , Estudos Retrospectivos
4.
Invest Radiol ; 44(3): 168-76, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19169143

RESUMO

OBJECTIVE: To evaluate the diagnostic efficacy (accuracy, sensitivity, specificity) of 1.0 M gadobutrol versus 0.5 M gadopentetate for the classification of lesions as either benign or malignant in patients with known or suspected liver lesions. METHODS AND MATERIALS: A multicenter, phase-III, randomized, interindividually controlled comparison study with blinded reader evaluation was performed to investigate the diagnostic efficacy of a bolus injection of 1.0 M gadobutrol compared with 0.5 M gadopentetate at a dose of 0.1 mmol Gd/kg BW. The imaging protocol included a dynamic 3D-evaluation, static conventional, and fat saturated T1-weighted sequences. MR datasets were evaluated by 3 independent radiologists. The standard of reference was defined by an independent truth panel (radiologist or hepatologist). The safety evaluation included adverse events, vital signs, and physical examination. RESULTS: A total of 497 of 572 patients were eligible for the final efficacy analysis. Noninferiority of gadobutrol-enhanced magnetic resonance imaging (MRI) for the classification of liver lesions was demonstrated on the basis of diagnostic accuracy determined by the on-site investigators (-0.098, 0.021) as well as for the average reader of the blinded evaluation (-0.096, 0.014) (95% confidence interval), compared with the predefined standard of reference. Very similar increases in sensitivity (ranging from approximately 10% to approximately 55%) and specificity (ranging from approximately 1% to approximately 18%) compared with precontrast MRI were also observed for the 2 contrast agent groups, with maximum differences of 4%.Very similar, low rates of adverse events were recorded for each of the 2 groups. No clinically relevant changes in vital signs or the results of the physical examination were observed in any patient. CONCLUSION: This study documents evidence for the noninferiority of a single i.v. bolus injection of 1.0 M gadobutrol (0.1 mmol/kg body weight) to 0.5 M gadopentetate (0.1 mmol/kg body weight) in the diagnostic assessment of liver lesions with contrast-enhanced MRI. The known excellent safety profile of gadobutrol was confirmed in this clinical trial and is similar to that of gadopentetate.


Assuntos
Gadolínio DTPA , Aumento da Imagem/métodos , Neoplasias Hepáticas/epidemiologia , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/estatística & dados numéricos , Compostos Organometálicos , Meios de Contraste , Método Duplo-Cego , Europa (Continente)/epidemiologia , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Prevalência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Stud Health Technol Inform ; 85: 536-41, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-15458148

RESUMO

A substantial component of an image-guided surgery system (IGSS) is the kind of three-dimensional (3D) presentation to the surgeon because the visual depth perception of the complex anatomy is of significant relevance for orientation. Therefore, we examined in this contribution four different visualization techniques, which were evaluated by eight surgeons. The IGSS developed by our group supports the intraoperative orientation of the surgeon by depicting a visualization of the spatially tracked surgical instruments with respect to intrahepatic vessels that have to be conserved vitally, the tumor, and preoperatively calculated resection planes. In the prelimenary trial presented here we examined the human ability to percept an intraoperative virtual scene and to solve given navigation tasks. The focus of the experiments was to measure the ability of eight surgeons to orientate intrahepaticaly and to transfer the percepted spatial relation to movements in real space. An autostereoscopic visualization with a prism-based display yielded that the navigation can be performed faster and more accurately than with the other visualization techniques.


Assuntos
Simulação por Computador , Imageamento Tridimensional , Neoplasias Hepáticas/cirurgia , Fígado/cirurgia , Orientação , Cirurgia Assistida por Computador , Interface Usuário-Computador , Anatomia Regional , Veias Hepáticas/anatomia & histologia , Humanos , Processamento de Imagem Assistida por Computador , Fígado/irrigação sanguínea , Veia Porta/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...