1.
J Am Heart Assoc ; 12(24): e031881, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38084735

RESUMO

BACKGROUND: We previously reported procedural and 30-day outcomes of a German early multicenter experience with the PASCAL system for severe mitral regurgitation (MR). This study reports 1-year outcomes of mitral valve transcatheter edge-to-edge repair with the PASCAL system according to MR etiology in a large all-comer cohort. METHODS AND RESULTS: Clinical and echocardiographic outcomes up to 1-year were investigated according to MR etiology (degenerative [DMR], functional [FMR], or mixed [MMR]) in the first 282 patients with symptomatic MR 3+/4+ treated with the PASCAL implant at 9 centers in 2019. A total of 282 patients were included (33% DMR, 50% FMR, 17% MMR). At discharge, MR reduction to ≤1+/2+ was achieved in 58%/87% of DMR, in 75%/97% of FMR, and in 78%/98% of patients with MMR (P=0.004). MR reduction to ≤1+/2+ was sustained at 30 days (50%/83% DMR, 67%/97% FMR, 74%/100% MMR) and at 1 year (53%/78% DMR, 75%/97% FMR, 67%/91% MMR) with significant differences between etiologies. DMR patients with residual MR 3+/4+ at 1-year had at least complex valve morphology in 91.7%. Valve-related reintervention was performed in 7.4% DMR, 0.7% FMR, and 0.0% MMR (P=0.010). At 1-year, New York Heart Association Functional Class was significantly improved irrespective of MR etiology (P<0.001). CONCLUSIONS: In this large all-comer cohort, mitral valve transcatheter edge-to-edge repair with the PASCAL system was associated with an acute and sustained MR reduction at 1-year in all causes. However, in patients with DMR, MR reduction was less pronounced, reflecting the high incidence of complex or very complex anatomies being referred for mitral valve transcatheter edge-to-edge repair.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/etiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Sistema de Registros , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/efeitos adversos
2.
JACC Cardiovasc Interv ; 15(24): 2541-2551, 2022 12 26.
Artigo em Inglês | MEDLINE | ID: mdl-36543448

RESUMO

BACKGROUND: In addition to the edge-to-edge MitraClip repair system, the edge-to-spacer PASCAL repair system was approved for percutaneous treatment of severe mitral regurgitation (MR). Comparative data are lacking. OBJECTIVES: The aim of this study was to compare procedural and short-term safety and efficacy of 2 leaflet-based transcatheter mitral valve repair systems. METHODS: Procedural and 30-day outcomes were investigated in a propensity score-matched cohort of 307 PASCAL and 307 MitraClip patients at 10 sites. Matching criteria included sex, age, left ventricular ejection fraction, New York Heart Association functional class, MR etiology, left ventricular end-diastolic diameter, left atrial volume index, and vena contracta width. The primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE). RESULTS: Technical success was 97.0% in the PASCAL group and 98.0% in the MitraClip group (P = 0.624). MR ≤2+ at discharge was comparable in both groups (PASCAL: 93.8% vs MitraClip: 92.4%; P = 0.527), with more patients exhibiting MR ≤1+ in the PASCAL group (70.5% vs 56.6%; P < 0.001). The postprocedural mean gradient was significantly higher in the MitraClip group (3.3 ± 1.5 mm Hg vs 3.9 ± 1.7 mm Hg; P < 0.001). At 30 days, all-cause mortality and MAE rates were similar (mortality: 1.7% vs 3.3%; P = 0.299; MAE: 3.9% vs 5.2%; P = 0.562). CONCLUSIONS: In this first large propensity score-matched comparison, procedural success rates and MAE did not differ significantly between patients treated with the PASCAL or MitraClip valve repair system. Procedural results with less than moderate MR and no elevated transmitral gradient were more common in the PASCAL group, which might have an impact on long-term outcome.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Volume Sistólico , Pontuação de Propensão , Função Ventricular Esquerda , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos
4.
JACC Case Rep ; 3(6): 893-896, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34317649

RESUMO

Patients with congenitally corrected transposition of the great arteries (ccTGA) with significant systemic tricuspid valve regurgitation and systemic right ventricular dysfunction have prohibitive surgical risk in adulthood. The PASCAL transcatheter valve repair system enables minimally invasive percutaneous tricuspid valve repair in the complex anatomy of patients with ccTGA. (Level of Difficulty: Intermediate.).

5.
Ann Intensive Care ; 11(1): 116, 2021 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-34319491

RESUMO

BACKGROUND: Percutaneous dilatational tracheotomy (PDT) has become an established procedure in intensive care units (ICU). However, the safety of this method has been under debate given the growing number of critically ill patients with high bleeding risk receiving anticoagulation, dual antiplatelet therapy (DAPT) or even a combination of both, i.e. triple therapy. Therefore, the purpose of this study, including such a high proportion of patients on antithrombotic therapy, was to investigate whether PDT in high-risk ICU patients is associated with elevated procedural complications and to analyse the risk factors for bleeding occurring during and after PDT. METHODS: PDT interventions conducted in ICUs at 12 European sites between January 2016 and October 2019 were retrospectively analysed for procedural complications. For subgroup analyses, patient stratification into clinically relevant risk groups based on anticoagulation and antiplatelet treatment regimens was performed and the predictors of bleeding occurrence were analysed. RESULTS: In total, 671 patients receiving PDT were included and stratified into four clinically relevant antithrombotic treatment groups: (1) intravenous unfractionated heparin (iUFH, prophylactic dosage) (n = 101); (2) iUFH (therapeutic dosage) (n = 131); (3) antiplatelet therapy (aspirin and/or P2Y12 receptor inhibitor) with iUFH (prophylactic or therapeutic dosage) except for triple therapy (n = 290) and (4) triple therapy (DAPT with iUFH in therapeutic dosage) (n = 149). Within the whole cohort, 74 (11%) bleedings were reported to be procedure-related. Bleeding occurrence during and after PDT was independently associated with low platelet count (OR 0.73, 95% CI [0.56, 0.92], p = 0.009), chronic kidney disease (OR 1.75, 95% CI [1.01, 3.03], p = 0.047) and previous stroke (OR 2.13, 95% CI [1.1, 3.97], p = 0.02). CONCLUSION: In this international, multicenter study bronchoscopy-guided PDT was a safe and low-complication airway management option, even in a cohort of high risk for bleeding on cardiovascular ICUs. Low platelet count, chronic kidney disease and previous stroke were identified as independent risk factors of bleeding during and after PDT but not triple therapy.

6.
ESC Heart Fail ; 8(4): 2419-2427, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33821578

RESUMO

AIMS: Therapy with phosphodiesterase-5 inhibitors (PDE5Is) after left ventricular assist device (LVAD) implantation has been associated with lower mortality and device thrombosis but increased risk for post-operative and gastrointestinal bleeding. We aimed to evaluate the impact of long-term PDE5Is on the overall bleeding risk after LVAD implantation. METHODS AND RESULTS: We retrospectively included patients who received a continuous-flow LVAD at our site and were prescribed with long-term oral PDE5Is after discharge from the index hospitalization. The primary endpoint was the occurrence of bleeding at 12 month follow-up. Secondary endpoints were all-cause death and the combination of bleeding and all-cause death. Our analysis included 109 patients of whom 75 (69%) received long-term PDE5Is. Mean age was 56 years, and 85% were male. At 12 months, 19 (17%) patients experienced at least one bleeding event. Patients on PDE5Is had higher bleeding rates (23% vs. 6%, P = 0.03) and more bleeding events per patient-year (0.32 vs. 0.06, P = 0.03) compared with patients not on PDE5Is. While overall bleeding incidence was excessively higher in the PDE5I group, there were no significant differences in the incidence of major bleeding (19% vs. 6%, P = 0.08) and gastrointestinal bleeding (11% vs. 3%, P = 0.18). Kaplan-Meier analysis revealed higher cumulative incidence of bleeding for the PDE5I group (log rank = 0.04) with no difference on all-cause death (log rank = 0.67) and the combination of bleeding and all-cause death (log rank = 0.13). Hospitalizations for bleeding and their duration were numerically higher in the PDE5I group (0.28 vs. 0.03, P = 0.07 and 2.4 vs. 0.2, P = 0.07, respectively). CONCLUSIONS: Phosphodiesterase-5 inhibitor treatment after LVAD implantation is associated with increased bleeding risk after LVAD implantation. The safety of long-term PDE5Is in LVAD patients remains unclear and needs to be further clarified in prospective studies with randomized study design.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Nucleotídeo Cíclico Fosfodiesterase do Tipo 5 , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Fosfodiesterase 5 , Estudos Prospectivos , Estudos Retrospectivos
7.
JACC Cardiovasc Interv ; 13(23): 2769-2778, 2020 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-33303115

RESUMO

OBJECTIVES: The aim of this study was to investigate the procedural and short-term safety and efficacy of a new leaflet-based transcatheter mitral valve repair system. BACKGROUND: The PASCAL repair system has been recently approved for percutaneous treatment of mitral regurgitation (MR). Novel characteristics are broad paddles positioned around a central spacer and the ability for independent leaflet capture. METHODS: Procedural and 30-day outcomes were investigated in the first 309 patients with symptomatic MR 3+/4+ treated with the PASCAL repair system at 10 sites. Primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE). RESULTS: Among the 309 patients (mean age 77 ± 10 years, 42% women, mean European System for Cardiac Operative Risk Evaluation II score 5.8 ± 4.5%) included in this study, MR etiology was degenerative in 33%, functional in 52%, and mixed in 16%. Eighty-six percent of patients were in New York Heart Association functional class III or IV. The technical success rate was 96%. Of 308 patients discharged alive, MR was ≤2+ in 93.5%. At 30 days, the MAE rate was 4.1%, with an estimated all-cause mortality rate of 2.0%, and 72% of patients were in New York Heart Association functional class ≤II (p < 0.001). Rates of device success and CLASP (Edwards PASCAL Transcatheter Mitral Valve Repair System Study) trial-defined clinical success were 81.9% and 86.9%, respectively. Single-leaflet device attachment occurred in 7 patients (2.3%). CONCLUSIONS: Mitral valve repair with the PASCAL system in the early post-approval phase was effective and safe, with high procedural success rates and low rates of MAE. MR was significantly reduced, accompanied by significant improvement in functional status.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Feminino , Humanos , Masculino , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
8.
Am J Cardiol ; 125(10): 1550-1557, 2020 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-32241550

RESUMO

The outcome of transfemoral transcatheter aortic valve implantation (TF-TAVI) with a self-expanding (SEP) versus a balloon-expandable prosthesis (BEP) in patients with a reduced ejection fraction (rEF, ≤40%) has not been previously investigated. Patients with rEF have an increased risk of death after TF-TAVI compared to patients with a preserved ejection fraction (pEF), and prosthesis choice might influence the outcome of these patients. We, therefore, sought to compare all-cause mortality of patients with rEF using a SEP versus a BEP. We retrospectively analyzed data of 679 single-center TF-TAVI patients. Patients were censored at death or completion of 1-year follow-up, whichever occurred first. Patients with rEF (n = 141, 21%) had an increased 1-year mortality compared to patients with pEF (28% vs 19%, p = 0.007). SEP were implanted in 149 patients (49 with rEF, 33%), while BEP were implanted in 530 patients (92 with rEF, 17%). In patients with pEF, 1-year mortality was similar after SEP- and BEP-implantation (16% vs 19%, p = 0.516). In patients with rEF, however, 1-year mortality was higher after SEP- than after BEP-implantation (43% vs 21%, p = 0.004). These patients had a higher incidence of new permanent pacemaker implantation (26.5% vs 13%, p = 0.046) and paravalvular leak ≥II° (21% vs 10%, p = 0.07), but both factors could not explain the excess mortality after SEP-implantation in the multivariate analysis. In patients with rEF, the use of a SEP was an independent predictor of 1-year mortality (HR 2.44, 95% CI 1.27 to 4.27, p = 0.007). In conclusion, patients with rEF had a higher 1-year mortality after TF-TAVI when a SEP instead of a BEP was used.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Feminino , Veia Femoral , Alemanha , Humanos , Masculino , Fatores de Risco , Volume Sistólico , Substituição da Valva Aórtica Transcateter/instrumentação
9.
Echocardiography ; 36(1): 28-37, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30484901

RESUMO

OBJECTIVES: To evaluate the impact of baseline left ventricular ejection fraction (LVEF) and its interaction with low-gradient aortic stenosis (LGAS) on all-cause mortality after transfemoral aortic valve implantation (TF-TAVI). METHODS: We reviewed mortality data of 624 consecutive single center TF-TAVI patients and categorized LVEF according to current ASE/EACVI recommendations (normal, mildly-, moderately-, and severely abnormal). RESULTS: Baseline LVEF was normal in 336 (53.8%), mildly abnormal in 160 (25.6%), moderately abnormal in 91 (14.6%), and severely abnormal in 37 (5.9%) patients, and 1-year mortality was 19%, 17%, 23%, and 43% (P = 0.002), respectively. Patients with LGAS had a similar 1-year mortality compared to those without LGAS in groups with normal (19% vs 19%, P = 0.899) and mildly abnormal LVEF (16% vs 17%, P = 0.898). One-year mortality of patients with LGAS was significantly greater than in those without LGAS in presence of moderately abnormal LVEF (31% vs 11%, P = 0.022), and it was numerically greater than in those without LGAS in presence of severely abnormal LVEF (48% vs 25%, P = 0.219). In multivariate analysis, only the combination of moderately/severely abnormal LVEF and LGAS predicted increased 1-year mortality (HR: 2.12, 95% CI: 1.4-3.2, P < 0.001). Other variables, including EuroSCORE I did not affect this result. CONCLUSIONS: Moderately/severely abnormal LVEF (≤40%) at baseline is associated with increased mortality after TF-TAVI, especially when the mean transvalvular aortic gradient is <40 mm Hg (LGAS), while outcomes in patients with normal and mildly abnormal LVEF are comparable regardless of the pressure gradient across the native aortic valve. (DRKS00013729).


Assuntos
Estenose da Valva Aórtica/complicações , Ecocardiografia/métodos , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/fisiopatologia , Substituição da Valva Aórtica Transcateter/mortalidade , Disfunção Ventricular Esquerda/complicações , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade
10.
EuroIntervention ; 8(12): 1398-406, 2013 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-23256946

RESUMO

AIMS: Residual paravalvular aortic regurgitation (PAR) after transcatheter aortic valve implantation (TAVI) is common. We therefore evaluated incidence, determinants and outcome of PAR after TAVI. METHODS AND RESULTS: Data from 167 consecutive transcatheter TAVI patients were analysed. PAR was graded by angiography and the pressure gradient between diastolic aortic pressure and left ventricular end-diastolic pressure (∆PDAP-LVEDP) after implantation. TAVI was technically successful in all patients. Mortality was 9% and 20% at 30 days and one year, respectively. Post-procedural PAR was absent in 54 patients (32.3%). Mild PAR was found in 89 (53.3%), moderate in 21 (12.6%), and moderate-to-severe in three patients (1.8%). Cardiovascular mortality at 30 days and one year was increased in patients with moderate and moderate-to-severe PAR compared to patients with no and mild PAR (46% vs. 4% and 73% vs. 7%, respectively, p<0.001). Receiver operating characteristic curve analysis suggested ∆PDAP-LVEDP ≤18 mmHg as a novel predictor of mortality, with an area under the curve of 0.97. CONCLUSIONS: In patients undergoing TAVI, moderate and moderate-to-severe PAR was observed in 14.4% and associated with increased cardiovascular mortality. A pressure gradient ∆PDAP-LVEDP≤18 mmHg carries adverse prognosis and requires further intervention.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/terapia , Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Área Sob a Curva , Pressão Arterial , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Feminino , Alemanha/epidemiologia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Incidência , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Análise Multivariada , Curva ROC , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Pressão Ventricular