Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Vet Intern Med ; 34(6): 2287-2295, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33001499

RESUMO

BACKGROUND: Glycemic variability (GV) is an indicator of glycemic control and can be evaluated by calculating the SD of blood glucose measurements. In humans with diabetes mellitus (DM), adding a glucagon-like peptide-1 (GLP-1) analogue to conventional therapy reduces GV. In diabetic cats, the influence of GLP-1 analogues on GV is unknown. OBJECTIVE: To evaluate GV in diabetic cats receiving the GLP-1 analogue exenatide extended release (EER) and insulin. ANIMALS: Thirty client-owned cats with newly diagnosed spontaneous DM. METHODS: Retrospective study. Blood glucose curves from a recent prospective placebo-controlled clinical trial generated 1, 3, 6, 10, and 16 weeks after starting therapy were retrospectively evaluated for GV. Cats received either EER (200 µg/kg) or 0.9% saline SC once weekly, insulin glargine and a low-carbohydrate diet. Mean blood glucose concentrations were calculated and GV was assessed by SD. Data were analyzed using nonparametric tests. RESULTS: In the EER group, GV (mean SD [95% confidence interval]) was lower at weeks 6 (1.69 mmol/L [0.9-2.48]; P = .02), 10 (1.14 mmol/L [0.66-1.62]; P = .002) and 16 (1.66 mmol/L [1.09-2.23]; P = .02) compared to week 1 (4.21 mmol/L [2.48-5.93]) and lower compared to placebo at week 6 (3.29 mmol/L [1.95-4.63]; P = .04) and week 10 (4.34 mmol/L [2.43-6.24]; P < .000). Cats achieving remission (1.21 mmol/L [0.23-2.19]) had lower GV compared to those without remission (2.96 mmol/L [1.97-3.96]; P = .01) at week 6. CONCLUSIONS AND CLINICAL IMPORTANCE: The combination of EER, insulin, and a low-carbohydrate diet might be advantageous in the treatment of newly diagnosed diabetic cats.


Assuntos
Doenças do Gato , Diabetes Mellitus Tipo 2 , Diabetes Mellitus , Animais , Glicemia , Doenças do Gato/tratamento farmacológico , Gatos , Diabetes Mellitus/tratamento farmacológico , Diabetes Mellitus/veterinária , Diabetes Mellitus Tipo 2/veterinária , Exenatida/uso terapêutico , Peptídeo 1 Semelhante ao Glucagon , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Estudos Prospectivos , Estudos Retrospectivos
2.
Res Vet Sci ; 118: 79-85, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29421488

RESUMO

With the aim to improve current therapeutic and monitoring options for diabetic cats, the present study compared pharmacodynamic parameters of protamine zinc insulin (PZI) and insulin degludec and validated the continuous glucose monitoring system (CGMS) iPro2 with Sof-sensor and Enlite-sensor focusing on the low glycemic range. Three doses (0.1, 0.2 and 0.3IU/kg) of the two insulin preparations and the CGMS iPro2 with two different sensors were tested in six healthy cats. After each insulin administration, onset of action, time to glucose nadir and duration of action were calculated by measuring glucose concentrations with a portable blood glucose meter (PBGM). After sensor placement, paired PBGM and sensor glucose measurements were done and analytical and clinical accuracy were calculated according to the ISO 15197:2013 criteria. Onset of action, time to glucose nadir and glucose nadir were similar for both insulin formulations. Duration of action of insulin degludec was significantly longer than those of PZI at 0.1IU/kg (P=0.043) and 0.2IU/kg (P=0.043). Overall, 166/191 (87%) Sof-sensor measurements and 106/121 (88%) Enlite-sensor measurements met ISO criteria for analytical accuracy, and all sensor measurements fulfilled ISO criteria for clinical accuracy. Insulin degludec was well tolerated in healthy cats and showed longer duration of action than PZI. Further studies on the use of insulin degludec in diabetic cats might be recommended. Both sensors had good clinical accuracy, when used with the CGMS iPro2, but the analytical accuracy was below the minimum set by ISO 15197:2013.


Assuntos
Glicemia/análise , Gatos , Insulina Isófana/farmacocinética , Insulina de Ação Prolongada/farmacocinética , Monitorização Ambulatorial/veterinária , Animais , Glicemia/metabolismo , Monitorização Ambulatorial/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA