Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Cancer Lett ; 588: 216783, 2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38462034

RESUMO

Inhibition of K-RAS effectors like B-RAF or MEK1/2 is accompanied by treatment resistance in cancer patients via re-activation of PI3K and Wnt signaling. We hypothesized that myotubularin-related-protein-7 (MTMR7), which inhibits PI3K and ERK1/2 signaling downstream of RAS, directly targets RAS and thereby prevents resistance. Using cell and structural biology combined with animal studies, we show that MTMR7 binds and inhibits RAS at cellular membranes. Overexpression of MTMR7 reduced RAS GTPase activities and protein levels, ERK1/2 phosphorylation, c-FOS transcription and cancer cell proliferation in vitro. We located the RAS-inhibitory activity of MTMR7 to its charged coiled coil (CC) region and demonstrate direct interaction with the gastrointestinal cancer-relevant K-RASG12V mutant, favouring its GDP-bound state. In mouse models of gastric and intestinal cancer, a cell-permeable MTMR7-CC mimicry peptide decreased tumour growth, Ki67 proliferation index and ERK1/2 nuclear positivity. Thus, MTMR7 mimicry peptide(s) could provide a novel strategy for targeting mutant K-RAS in cancers.


Assuntos
Neoplasias , Proteínas Tirosina Fosfatases não Receptoras , Animais , Humanos , Camundongos , Peptídeos , Fosfatidilinositol 3-Quinases/metabolismo , Proteínas Tirosina Fosfatases não Receptoras/genética , Proteínas Tirosina Fosfatases não Receptoras/metabolismo , Transdução de Sinais
2.
Front Cardiovasc Med ; 10: 1223035, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37965085

RESUMO

Introduction: Pericoronary adipose tissue (PCAT) stands in complex bidirectional interaction with the surrounding arteries and is known to be connected to many cardiovascular diseases involving vascular inflammation. PCAT texture may be influenced by other cardiovascular risk factors such as hypercholesterolemia. The recently established photon-counting CT could improve texture analysis and help detect those changes by offering higher spatial resolution and signal-to-noise ratio. Methods: In this retrospective, single-center, IRB-approved study, PCAT of the left and right coronary artery was manually segmented and radiomic features were extracted using pyradiomics. The study population consisted of a test collective and a validation collective. The collectives were each divided into two groups defined by the presence or absence of hypercholesterolemia, taken from self-reported conditions and confirmed by medical records. Mean and standard deviation were calculated with Pearson correlation coefficient for correlation of features and visualized as boxplots and heatmaps using R statistics. Random forest feature selection was performed to identify differentiating features between the two groups. 66 patients were enrolled in this study (34 female, mean age 58 years). Results: Two radiomics features allowing differentiation between PCAT texture of the groups were identified (p-values between 0.013 and 0.24) and validated. Patients with hypercholesterolemia presented with a greater concentration of high-density values as indicated through analysis of specific texture features as "gldm_HighGrayLevelEmphasis" (23.95 vs. 22.99) and "glrlm_HighGrayLevelRunEmphasis" (24.21 vs. 23.31). Discussion: Texture analysis of PCAT allowed differentiation between patients with and without hypercholesterolemia offering a potential imaging biomarker for this specific cardiovascular risk factor.

3.
BMC Med Imaging ; 23(1): 97, 2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-37495950

RESUMO

BACKGROUND: Cardiovascular diseases remain the world's primary cause of death. The identification and treatment of patients at risk of cardiovascular events thus are as important as ever. Adipose tissue is a classic risk factor for cardiovascular diseases, has been linked to systemic inflammation, and is suspected to contribute to vascular calcification. To further investigate this issue, the use of texture analysis of adipose tissue using radiomics features could prove a feasible option. METHODS: In this retrospective single-center study, 55 patients (mean age 56, 34 male, 21 female) were scanned on a first-generation photon-counting CT. On axial unenhanced images, periaortic adipose tissue surrounding the thoracic descending aorta was segmented manually. For feature extraction, patients were divided into three groups, depending on coronary artery calcification (Agatston Score 0, Agatston Score 1-99, Agatston Score ≥ 100). 106 features were extracted using pyradiomics. R statistics was used for statistical analysis, calculating mean and standard deviation with Pearson correlation coefficient for feature correlation. Random Forest classification was carried out for feature selection and Boxplots and heatmaps were used for visualization. Additionally, monovariable logistic regression predicting an Agatston Score > 0 was performed, selected features were tested for multicollinearity and a 10-fold cross-validation investigated the stability of the leading feature. RESULTS: Two higher-order radiomics features, namely "glcm_ClusterProminence" and "glcm_ClusterTendency" were found to differ between patients without coronary artery calcification and those with coronary artery calcification (Agatston Score ≥ 100) through Random Forest classification. As the leading differentiating feature "glcm_ClusterProminence" was identified. CONCLUSION: Changes in periaortic adipose tissue texture seem to correlate with coronary artery calcium score, supporting a possible influence of inflammatory or fibrotic activity in perivascular adipose tissue. Radiomics features may potentially aid as corresponding biomarkers in the future.


Assuntos
Doenças Cardiovasculares , Doença da Artéria Coronariana , Humanos , Masculino , Feminino , Cálcio , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem
4.
Sci Rep ; 13(1): 12036, 2023 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-37491452

RESUMO

Pectus excavatum (PE) is a congenital malformation with a funnel-shaped depression of the sternum that can lead to cardiac symptoms. However, there are patients with thoracic constriction (defined as elevated Haller-Index > 3.25 determined by cardiac magnetic resonance imaging (CMR)) without visible evidence of PE, leading to similar complaints. Between January 2004 till June 2020, patients who underwent CMR for further evaluation of the heart, due to cardiac symptoms were enrolled and compared to controls. Biventricular global strain analysis was assessed using feature tracking (CMR-FT). ECG and/or Holter recordings were performed to detect rhythm events. Cardiac symptoms were evaluated in detail using a questionnaire. Finally, 88 patients (male 35, female 53) with elevated Haller-Index (3.9 ± 0.8) were included and compared to CMR data from 25 individuals with confirmed PE and 25 healthy controls (HC). Mean age at time of CMR was 35 ± 16 years. The most common symptoms at presentation were palpitations (41%), followed by dyspnea (24%) and atypical chest pain (14%). Three patients (3%) had atrial fibrillation or atrial flutter. Concomitant phenomena were pericardial effusion in 39% and mitral valve prolapse (MVP) in 27% of the study cohort. While there were no differences in left ventricular function or volumes, right ventricular function (RVEF) was significantly lower in patients with internal PE compared to HC (RVEF (%) 50 ± 5 vs 59 ± 4, p < 0.01). Strain analysis revealed only discrete changes in RV strain, implying a purely mechanical problem in the absence of structural changes. RV dimensions were negatively correlated with the size of thoracic indices (r = 0.41), reflecting the extent of thoracic constriction. MVP was more prevalent in patients with greater thoracic indices (r = 0.24). The described cohort, referred to as internal PE because of the absence of external changes, showed similar CMR morphologic findings as patients with real PE (especially altered dimensions of the right heart and a lower RVEF). In addition, there was a high incidence of rhythm disturbances, such as extrasystoles or arrhythmias. In one-third of the study cohort additional abnormalities such as pericardial effusion or MVP were present, with MVP being found more frequently in patients with larger thoracic indices, suggesting a possible common pathogenesis.Trial registration: ISRCTN registry, ISRCTN15355937, retrospectively registered 03.06.2022, https://www.isrctn.com/ISRCTN15355937?q=15355937&filters=&sort=&offset=1&totalResults=1&page=1&pageSize=10 .


Assuntos
Tórax em Funil , Prolapso da Valva Mitral , Derrame Pericárdico , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Tórax em Funil/diagnóstico por imagem , Derrame Pericárdico/complicações , Constrição , Imageamento por Ressonância Magnética , Coração , Imagem Cinética por Ressonância Magnética/métodos
5.
Int J Cardiovasc Imaging ; 39(5): 1065-1073, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36773035

RESUMO

Coronary computed tomography angiography has become a mainstay in diagnosing coronary artery disease and is increasingly used in screening symptomatic patients. Recently, photon-counting computed tomography (PCCT) has been introduced into clinical practice, offering higher spatial and temporal resolution. As the applied radiation dose is highly dependent on the choice of scan mode and is lowest using the ultra-fast high-pitch (FLASH) mode, guidelines for their application are needed. From a retrospective study investigating the properties of a novel photon-counting computed tomography, all patients who underwent FLASH-mode PCCT angiography were selected between January and April 2022. This resulted in a study population of 46 men and 27 women. We recorded pre- and intrascan ECG readings and calculated heart rate (maximum heart rate 73 bpm) as well heart rate variability (maximum HRV 37 bpm) as measured by the standard deviation of the heart rate. Diagnostic quality and motion artifacts scores were recorded for each coronary artery segment by consensus between two readers. We found a highly significant association between heart rate variability and image quality (p < 0.001). The heart rate itself was not independently associated with image quality. Both heart rate and heart rate variability were significantly associated with the presence of motion artifacts in a combined model. Scan heart rate variability-but not heart rate itself-is a highly significant predictor of reduced image quality on high-pitch coronary photon-counting computed tomography angiography. This may be due to better scanner architecture and an increased temporal resolution compared to conventional energy-integrating detector computed tomography, which has to be addressed in a comparison study in the future.


Assuntos
Angiografia por Tomografia Computadorizada , Masculino , Humanos , Feminino , Frequência Cardíaca , Estudos Retrospectivos , Estudos de Viabilidade , Valor Preditivo dos Testes , Angiografia Coronária/métodos , Doses de Radiação
6.
Eur Radiol ; 33(7): 4905-4914, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36809435

RESUMO

OBJECTIVES: Radiomics image data analysis offers promising approaches in research but has not been implemented in clinical practice yet, partly due to the instability of many parameters. The aim of this study is to evaluate the stability of radiomics analysis on phantom scans with photon-counting detector CT (PCCT). METHODS: Photon-counting CT scans of organic phantoms consisting of 4 apples, kiwis, limes, and onions each were performed at 10 mAs, 50 mAs, and 100 mAs with 120-kV tube current. The phantoms were segmented semi-automatically and original radiomics parameters were extracted. This was followed by statistical analysis including concordance correlation coefficients (CCC), intraclass correlation coefficients (ICC), as well as random forest (RF) analysis, and cluster analysis to determine the stable and important parameters. RESULTS: Seventy-three of the 104 (70%) extracted features showed excellent stability with a CCC value > 0.9 when compared in a test and retest analysis, and 68 features (65.4%) were stable compared to the original in a rescan after repositioning. Between the test scans with different mAs values, 78 (75%) features were rated with excellent stability. Eight radiomics features were identified that had an ICC value greater than 0.75 in at least 3 of 4 groups when comparing the different phantoms in a phantom group. In addition, the RF analysis identified many features that are important for distinguishing the phantom groups. CONCLUSION: Radiomics analysis using PCCT data provides high feature stability on organic phantoms, which may facilitate the implementation of radiomics analysis likewise in clinical routine. KEY POINTS: • Radiomics analysis using photon-counting computed tomography provides high feature stability. • Photon-counting computed tomography may pave the way for implementation of radiomics analysis in clinical routine.


Assuntos
Algoritmo Florestas Aleatórias , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos , Fótons
7.
Eur Radiol ; 33(4): 2415-2425, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36350390

RESUMO

OBJECTIVE: Subjective and objective image quality comparison of bone microstructure and disease-related abnormalities in multiple myeloma patients using a 1st-generation dual-source photon-counting detector CT(DS-PCD-CT) and a 2nd-generation dual-source dual-energy (energy-integrating detector) CT (DS-EID-CT). METHODS: Fifty multiple myeloma patients (mean age 67.7 ± 10.9 years,16 females) were prospectively enrolled. Unenhanced whole-body CTs were clinically indicated and performed on DS-EID-CT and DS-PCD-CT (median time difference: 12 months). DS-PCD-CT was performed in Quantumplus UHR mode and DS-EID-CT was performed using dual-energy mode. DS-PCD-CT kernel was set at Br64 with Quantum iterative reconstruction strength Q1; for DS-EID-CT a comparable I70f kernel with SAFIRE iterative reconstruction strength 1 was used. Two independent radiologists assessed image quality subjectively using a 5-point Likert scale considering delineation and sharpness of trabecular bone and lytic bone lesions in the spine and pelvic bones. Additionally, ImageJ was used for quantification of bony septa inside the cancellous bone and through or the edges of osteolysis. RESULTS: Overall quality as well as detectability and sharpness in the delineation of lytic bone lesions were superior for DS-PCD-CT compared with DS-EID-CT (p < 0.0001). The inter-reader agreement for subjective image quality readings showed excellent consistency(α = 94.2-98.8). CTDI and DLP mean values for DS-PCD-CT and DS-EID-CT were 1107.4 ± 247.6 mGy*cm and 8.2 ± 1.8 mGy vs. 1344.3 ± 204.6 mGy*cm and 10.1 ± 1.9 mGy. The quantitative metric for bone microstructure in the femoral head showed significantly better visualization of trabeculae in DS-PCD-CT compared with DS-EID-CT (p < 0.0001). Quantitative analyses of edge sharpness of osteolysis showed significant steeper edges for DS-PCD-CT (p < 0.0001). CONCLUSION: DS-PCD-CT significantly improves spatial resolution of bony microstructure and lytic bone lesions compared to DS-EID-CT. KEY POINTS: • Application of photon-counting detector CT is superior to dual-source dual-energy integrating detector in clinical workup of multiple myeloma patients. • Compared to energy integrating detectors, photon-counting detectors significantly increase the spatial resolution of bone microstructure including disease-related lytic bone lesions in patients with multiple myeloma.


Assuntos
Mieloma Múltiplo , Osteólise , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Mieloma Múltiplo/diagnóstico por imagem , Osteólise/diagnóstico por imagem , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Fótons
8.
Int J Cardiovasc Imaging ; 38(11): 2459-2467, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36434338

RESUMO

Perivascular adipose tissue is known to be metabolically active. Volume and density of periaortic adipose tissue are associated with aortic calcification as well as aortic diameter indicating a possible influence of periaortic adipose tissue on the development of aortic calcification. Due to better spatial resolution and signal-to-noise ratio, new CT technologies such as photon-counting computed tomography may allow the detection of texture alterations of periaortic adipose tissue depending on the existence of local aortic calcification possibly outlining a biomarker for the development of arteriosclerosis. In this retrospective, single-center, IRB-approved study, periaortic adipose tissue was segmented semiautomatically and radiomics features were extracted using pyradiomics. Statistical analysis was performed in R statistics calculating mean and standard deviation with Pearson correlation coefficient for feature correlation. For feature selection Random Forest classification was performed. A two-tailed unpaired t test was applied to the final feature set. Results were visualized as boxplots and heatmaps. A total of 30 patients (66.6% female, median age 57 years) were enrolled in this study. Patients were divided into two subgroups depending on the presence of local aortic calcification. By Random Forest feature selection a set of seven higher-order features could be defined to discriminate periaortic adipose tissue texture between these two groups. The t test showed a statistic significant discrimination for all features (p < 0.05). Texture changes of periaortic adipose tissue associated with the existence of local aortic calcification may lay the foundation for finding a biomarker for development of arteriosclerosis.


Assuntos
Tecido Adiposo , Arteriosclerose , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Retrospectivos , Valor Preditivo dos Testes , Tecido Adiposo/diagnóstico por imagem , Tomografia Computadorizada por Raios X
9.
J Clin Med ; 11(20)2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36294324

RESUMO

The aim of this paper is to evaluate the diagnostic image quality of spectral dual-source photon-counting detector coronary computed tomography angiography (PCD-CCTA) for coronary artery disease in a multicenter study. The image quality (IQ), assessability, contrast-to-noise ratio (CNR), Agatston score, and radiation exposure were measured. Stenoses were quantified and compared with invasive coronary angiography, if available. A total of 92 subjects (65% male, age 58 ± 14 years) were analyzed. The prevalence of significant coronary artery disease (CAD) (stenosis ≥ 50%) was 17% of all patients, the range of the Agatston score was 0−2965 (interquartile range (IQR) 0−135). The IQ was very good (one, IQR one−two), the CNR was very high (20 ± 10), and 5% of the segments were rated non-diagnostic. The IQ and assessability were higher in proximal coronary segments (p < 0.001). Agatston scores up to 600 did not significantly affect the assessability of the coronary segments (p = 0.3). Heart rate influenced assessability only at a high-pitch mode (p = 0.009). For the invasive coronary angiography (ICA) subgroup (n = nine), the diagnostic performance for CAD per segment was high (sensitivity 92%, specificity 96%), although the limited number of patients who underwent both diagnostic modalities limits the generalization of this finding at this stage. PCD-CCTA provides good image quality for low and moderate levels of coronary calcifications.

10.
Sci Rep ; 12(1): 14228, 2022 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-35987779

RESUMO

Systemic mastocytosis (SM) is characterized by multifocal accumulation of neoplastic mast cells (MCs), predominately affecting the bone marrow (BM). Imaging with computed tomography (CT) is used for assessment of bone mineral density and structure. However, the value of functional imaging with dual-energy CT (DECT) and the assessment of virtual-non-calcium attenuation values (VNCa-AV) for visualization of BM disease burden in SM has not yet been assessed. DECT of the axial skeleton was performed in 18 patients with SM (indolent SM [ISM], n = 6; smoldering SM [SSM]/advanced SM [AdvSM], n = 12) and 18 control subjects. VNCa-AV were obtained in 5 representative vertebraes per patient and correlated with laboratory, morphologic and molecular parameters. VNCa-AV strongly correlated with quantitative BM MC infiltration (r = 0.7, R2 = 0.49, P = 0.001) and serum tryptase levels (r = 0.7, R2 = 0.54, P < 0.001). Mean VNCa-AV were significantly higher in SSM/AdvSM as compared to ISM (- 9HU vs. - 54HU, P < 0.005) and controls (- 38HU, P < 0.005). Nine of 10 (90%) patients with a VNCa-AV > - 30HU and 7/7 (100%) patients with a VNCa-AV > - 10HU had SSM or AdVSM. BM VNCa-AV provide information about the MC burden of SM patients and correlate with SM subtypes. DECT may therefore serve as a supplementary tool for SM diagnosis, subclassification and monitoring in a one-stop-shop session.


Assuntos
Doenças da Medula Óssea , Mastocitose Sistêmica , Medula Óssea/diagnóstico por imagem , Humanos , Mastócitos , Mastocitose Sistêmica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
11.
Diagnostics (Basel) ; 12(7)2022 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-35885567

RESUMO

The coronary artery calcium score is an independent risk factor of the development of adverse cardiac events. The severity of coronary artery calcification may influence the myocardial texture. Due to higher spatial resolution and signal-to-noise ratio, new CT technologies such as PCCT may improve the detection of texture alterations depending on the severity of coronary artery calcification. In this retrospective, single-center, IRB-approved study, left ventricular myocardium was segmented and radiomics features were extracted using pyradiomics. The mean and standard deviation with the Pearson correlation coefficient for correlations of features were calculated and visualized as boxplots and heatmaps. Random forest feature selection was performed. Thirty patients (26.7% women, median age 58 years) were enrolled in the study. Patients were divided into two subgroups depending on the severity of coronary artery calcification (Agatston score 0 and Agatston score ≥ 100). Through random forest feature selection, a set of four higher-order features could be defined to discriminate myocardial texture between the two groups. When including the additional Agatston 1-99 groups as a validation, a severity-associated change in feature intensity was detected. A subset of radiomics features texture alterations of the left ventricular myocardium was associated with the severity of coronary artery calcification estimated by the Agatston score.

12.
Diagnostics (Basel) ; 12(5)2022 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-35626448

RESUMO

The implementation of radiomics-based, quantitative imaging parameters is hampered by a lack of stability and standardization. Photon-counting computed tomography (PCCT), compared to energy-integrating computed tomography (EICT), does rely on a novel detector technology, promising better spatial resolution and contrast-to-noise ratio. However, its effect on radiomics feature properties is unknown. This work investigates this topic in myocardial imaging. In this retrospective, single-center IRB-approved study, the left ventricular myocardium was segmented on CT, and the radiomics features were extracted using pyradiomics. To compare features between scanners, a t-test for non-paired samples and F-test was performed, with a threshold of 0.05 set as a benchmark for significance. Feature correlations were calculated by the Pearson correlation coefficient, and visualization was performed with heatmaps. A total of 50 patients (56% male, mean age 56) were enrolled in this study, with equal proportions of PCCT and EICT. First-order features were, nearly, comparable between both groups. However, higher-order features showed a partially significant difference between PCCT and EICT. While first-order radiomics features of left ventricular myocardium show comparability between PCCT and EICT, detected differences of higher-order features may indicate a possible impact of improved spatial resolution, better detection of lower-energy photons, and a better signal-to-noise ratio on texture analysis on PCCT.

13.
Ann Allergy Asthma Immunol ; 128(3): 314-318, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34637924

RESUMO

BACKGROUND: Patients with systemic mastocytosis (SM) are at increased risk of hypersensitivity reactions (HRs). Although Hymenoptera venoms are the predominant triggers, cases of contrast media-induced HR (CMIHR) have also been reported and prophylactic premedication is often performed. However, data from larger series are limited and differences between indolent and advanced SM have not yet been investigated. OBJECTIVE: To determine the incidence and severity of CMIHR in all subtypes of SM. METHODS: We analyzed 162 adult patients with SM (indolent systemic mastocytosis [ISM], n = 65; advanced systemic mastocytosis [advSM], n = 97). First, the cumulative incidence of CMIHR was retrospectively assessed in the patient's history. Second, at our institution, patients underwent 332 contrast media (CM)-enhanced imaging including 80 computed tomography (CT) scans with iodine-based contrast agent and 252 magnetic resonance imaging (MRI) with a gadolinium-based contrast agent, and tolerance was assessed. RESULTS: Previous CMIHRs to CT (vomiting, n = 1, erythema, n = 1, cardiovascular shock, n = 1), and MRI (dyspnea, n = 1, cardiovascular shock, n = 1) had been reported by 4 out of 162 (2.5%) patients (ISM, n = 3; advSM, n = 1). In contrast, during or after 332 CM-enhanced CT or MRI examinations at our institution, no CMIHRs were reported. Premedication was solely given to 3 patients before CT scans, including 1 with previous CMIHR, who tolerated the imaging well. CONCLUSION: We conclude that: (1) there is a substantial discrepancy between the perception and prevalence of HRs to CM in SM; (2) reactions are scarce in ISM and even rarer in advSM; and (3) in SM patients without previous history of CM hypersensitivity, prophylactic premedication before CM-enhanced CT or MRI is dispensable.


Assuntos
Venenos de Artrópodes , Mastocitose Sistêmica , Mastocitose , Adulto , Meios de Contraste/efeitos adversos , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos
14.
Laryngorhinootologie ; 101(5): 390-398, 2022 05.
Artigo em Alemão | MEDLINE | ID: mdl-34902864

RESUMO

OBJECTIVE: Intraorbital masses represent a condition that is frequently threatening for the visual system. A rigorous differential diagnosis is essential to promptly initiate appropriate therapy and optimize prognosis. MATERIALS/METHODS: Narrative review of current literature and expert recommendations. For further illustration we describe the case of a 71-year-old male admitted to our department three months after sinus surgery. Postoperative intraorbital hematoma of the right orbit had been treated conservatively with antibiotics/corticosteroids, leading to a near-complete unilateral visual loss. The immediate surgical intervention aimed at decompression of the orbit and the optical nerve. Due to the delay, the intervention could not prevent formation of a lipogranuloma. Inflammatory phases associated with the lipogranuloma are successfully managed by conservative treatment based on multidisciplinary recommendations. RESULTS: In the case reported, delay of surgical therapy acted as a cause of intraorbital lipogranuloma formation. Literature supports our recommendation of immediate surgical intervention in case of acute retrobulbar hematoma. Besides acute conditions, intraorbital masses can be a sign of systemic disease. In every case, a multidisciplinary therapeutic approach is required for adequate management. CONCLUSIONS: Intraorbital masses can occur as a complication of trauma or e.g. sinus surgery. On the other hand they can be a sign of systemic disease. Timely diagnosis and treatment prevents from visual loss. That is why rigorous differential diagnosis is essential for every discipline managing intraorbital lesions.


Assuntos
Hematoma , Órbita , Idoso , Diagnóstico Diferencial , Hematoma/diagnóstico , Humanos , Masculino , Órbita/diagnóstico por imagem , Órbita/cirurgia , Transtornos da Visão/diagnóstico , Transtornos da Visão/etiologia
15.
Anticancer Res ; 41(9): 4423-4429, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34475064

RESUMO

AIM: To evaluate the image quality and time saving using simultaneous multi-slice (SMS)-accelerated T2-weighted turbo spin echo (TSE) sequences compared to standard T2 TSE sequences in breast magnetic resonance imaging (MRI). PATIENTS AND METHODS: Thirty patients were examined with an SMS-accelerated T2 TSE sequence and a standard T2 TSE sequence as part of a breast MRI protocol at 1.5T. Image quality, signal homogeneity and tissue delineation were evaluated. For quantitative assessment, the signal-to-noise ratio (SNR) was measured from representative SNR maps. RESULTS: There were no significant differences regarding tissue delineation and signal homogeneity. Image quality was rated equal at the chest wall and the breasts but decreased in the axilla on SMS-T2 TSE (p=0.01) with a simultaneous decrease of SNR (p=0.03). This did not significantly impact the overall image quality (p=0.2). The acquisition time for SMS-T2 TSE was 48% shorter compared to standard T2 TSE. CONCLUSION: SMS-acceleration for T2-weighted imaging of the breast at 1.5T substantially reduces acquisition time while maintaining comparable quantitative and qualitative image quality. This may pave the way for protocol abbreviation especially in a high-throughput clinical workspace.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Razão Sinal-Ruído
16.
Urol Int ; 105(7-8): 600-604, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33915535

RESUMO

PURPOSE: Low-dose computer tomography (NCCT) is the standard imaging modality for patients with acute flank pain with a suspicion of urolithiasis. The stone size is usually measured 2D by a radiologist. We compared 3D stone measurement using different windows to the 2D measurement and evaluated the clinical impact on ureterorenoscopic stone removal (URS). METHODS: One hundred sixty-four patients (201 stones) with a preoperative NCCT, following a URS within 4 weeks, were included in this study. Stone location, number and size of stones, operating time, and laser lithotripsy were documented. Stones were measured in 3D using bone and soft tissue window. The maximum diameter was compared to the radiological report. The U test, Kruskal-Wallis, and regression were used for statistical analyses. RESULTS: Almost two-thirds (64.68%; 130 stones) of stone measurements in 3D with the bone window were lower than the radiologist reports in 2D. One-third (34.83%; 70 stones) of stone measurements were higher and 0.5% (1 stone) reported the same size. Using the 3D soft tissue window, 81.09% (163 stones), 17.91% (37 stones), and 1% (2 stones) of stones were measured bigger, smaller, or had the same measurement results, respectively. In the clinical setting, we could calculate a cutoff for laser lithotripsy at a maximum stone diameter of 5.70 mm (p < 0.01) with the 3D and 6.01 mm with the 2D measurements, respectively, and found a significant correlation between maximum stone diameter and operating time (p < 0.01) and number of stones and operating time (p < 0.01 with and p = 0.02 without laser). CONCLUSION: 3D stone measurement with bone window seems to be more accurate than 2D measurement, but 2D is sufficient for planning stone treatment.


Assuntos
Cálculos Renais/diagnóstico por imagem , Cálculos Renais/cirurgia , Tomografia Computadorizada por Raios X/métodos , Cálculos Ureterais/diagnóstico por imagem , Cálculos Ureterais/cirurgia , Ureteroscopia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
17.
Urol Int ; 105(1-2): 108-117, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33045708

RESUMO

INTRODUCTION: To compare RENAL, preoperative aspects and dimensions used for an anatomical (PADUA) classification, and Mayo Adhesive Probability (MAP) scores with the respective intraoperative findings and surgeon's assessment in predicting surgical outcome of patients undergoing partial nephrectomy. METHODS: Data of 150 eligible patients treated at the University Medical Center Mannheim between 2016 and 2018 were analyzed. Tumors were radiologically and intraoperatively assessed by PADUA, RENAL, and MAP scores and surgeon's assessment. Correlations and regression models were created to predict ischemia time (IT), major complications, and Trifecta (negative surgical margin, IT < 25 min, and absence of major complications). RESULTS: There were strong correlations between radiological and intraoperative RENAL (r = 0.68; p < 0.001) and PADUA scores (r = 0.72; p < 0.001). Radiological RENAL, PADUA, and MAP scores and surgeon's assessment were independent predictors of Trifecta (OR = 0.71, p = 0.015; OR = 0.77, p = 0.035; OR = 0.65, p = 0.012; OR = 0.40, p = 0.005, respectively). IT showed significant associations with radiological RENAL, PADUA, and surgeon's assessment (OR = 1.41, p = 0.033; OR = 1.34, p = 0.044; OR = 3.04, p = 0.003, respectively). MAP score proved as only independent predictor of major complications (OR = 2.12, p = 0.002). CONCLUSION: Radiologically and intraoperatively assessed scores correlated well with each other. Intraoperative nephrometry did not outperform radiological scores in predicting outcome confirming the value of the existing systems. MAP score correlates well with surgeon's assessment of perirenal fat and major complications underlining the importance of perirenal fat characteristics.


Assuntos
Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Nefrectomia , Carga Tumoral , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Renais/classificação , Carcinoma de Células Renais/cirurgia , Feminino , Humanos , Período Intraoperatório , Neoplasias Renais/classificação , Neoplasias Renais/cirurgia , Masculino , Pessoa de Meia-Idade , Nefrectomia/métodos , Período Pré-Operatório , Prognóstico , Adulto Jovem
18.
Acta Radiol ; 62(5): 695-704, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32600068

RESUMO

BACKGROUND: The combination of motion-insensitive, high-temporal, and spatial resolution imaging with evaluation of quantitative perfusion has the potential to increase the diagnostic capabilities of magnetic resonance imaging (MRI) in the female pelvis. PURPOSE: To compare a free-breathing compressed-sensing VIBE (fbVIBE) with flexible temporal resolution (range = 4.6-13.8 s) with breath-hold VIBE (bhVIBE) and to evaluate the potential value of quantifying uterine perfusion. MATERIAL AND METHODS: A total of 70 datasets from 60 patients (bhVIBE: n = 30; fbVIBE: n = 40) were evaluated by two radiologists. Only temporally resolved reconstruction (fbVIBE) was performed on 30 of the fbVIBE datasets. For a subset (n = 10) of the fbVIBE acquisitions, a time- and motion-resolved reconstruction (mrVIBE) was evaluated. Image quality (IQ), artifacts, diagnostic confidence (DC), and delineation of uterine structures (DoS) were graded on Likert scales (IQ/DC/DoS: 1 (non-diagnostic) to 5 (perfect); artifacts: 1 (no artifacts) to 5 (severe artifacts)). A Tofts model was applied for perfusion analysis. Ktrans was obtained in the myometrium (Mm), junctional zone (Jz), and cervix (Cx). RESULTS: The median IQ/DoS/DC scores of fbVIBE (4/5/5 κ >0.7-0.9) and bhVIBE (4/4/4; κ = 0.5-0.7; P > 0.05) were high, but Artifacts were graded low (fbVIBE/bhVIBE: 2/2; κ = 0.6/0.5; P > 0.05). Artifacts were only slightly improved by the additional motion-resolved reconstruction (fbVIBE/mrVIBE: 2/1.5; P = 0.08); fbVIBE was preferred in most cases (7/10). Significant differences of Ktrans values were found between Cx, Jz, and Mm (0.12/0.21/0.19; P < 0.05). CONCLUSION: The fbVIBE sequence allows functional and morphological assessment of the uterus at comparable IQ to bhVIBE.


Assuntos
Imageamento por Ressonância Magnética/métodos , Doenças Uterinas/diagnóstico por imagem , Doenças Uterinas/fisiopatologia , Útero/diagnóstico por imagem , Útero/fisiologia , Adulto , Artefatos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Respiração
19.
Eur Arch Otorhinolaryngol ; 278(7): 2473-2483, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32910225

RESUMO

PURPOSE: Augmented reality improves planning and execution of surgical procedures. The aim of this study was to evaluate the feasibility of a 3D augmented reality hologram in live parotic surgery. Another goal was to develop an accuracy measuring instrument and to determine the accuracy of the system. METHODS: We created a software to build and manually align 2D and 3D augmented reality models generated from MRI data onto the patient during surgery using the HoloLens® 1 (Microsoft Corporation, Redmond, USA). To assess the accuracy of the system, we developed a specific measuring tool applying a standard electromagnetic navigation device (Fiagon GmbH, Hennigsdorf, Germany). RESULTS: The accuracy of our system was measured during real surgical procedures. Training of the experimenters and the use of fiducial markers significantly reduced the accuracy of holographic system (p = 0.0166 and p = 0.0132). Precision of the developed measuring system was very high with a mean error of the basic system of 1.3 mm. Feedback evaluation demonstrated 86% of participants agreed or strongly agreed that the HoloLens will play a role in surgical education. Furthermore, 80% of participants agreed or strongly agreed that the HoloLens is feasible to be introduced in clinical routine and will play a role within surgery in the future. CONCLUSION: The use of fiducial markers and repeated training reduces the positional error between the hologram and the real structures. The developed measuring device under the use of the Fiagon navigation system is suitable to measure accuracies of holographic augmented reality images of the HoloLens.


Assuntos
Realidade Aumentada , Cirurgia Assistida por Computador , Alemanha , Humanos
20.
PLoS One ; 15(11): e0241590, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33180805

RESUMO

OBJECTIVES: The aim of this study was to establish quantitative CT (qCT) parameters for pathophysiological understanding and clinical use in patients with acute respiratory distress syndrome (ARDS). The most promising parameter is introduced. MATERIALS AND METHODS: 28 intubated patients with ARDS obtained a conventional CT scan in end-expiratory breathhold within the first 48 hours after admission to intensive care unit (ICU). Following manual segmentation, 137 volume- and lung weight-associated qCT parameters were correlated with 71 clinical parameters such as blood gases, applied ventilation pressures, pulse contour cardiac output measurements and established status and prognosis scores (SOFA, SAPS II). RESULTS: Of all examined qCT parameters, excess lung weight (ELW), i.e. the difference between a patient's current lung weight and the virtual lung weight of a healthy person at the same height, displayed the most significant results. ELW correlated significantly with the amount of inflated lung tissue [%] (p<0.0001; r = -0.66) and was closely associated with the amount of extravascular lung water (EVLW) (p<0.0001; r = 0.72). More substantially than the oxygenation index (PaO2/FiO2) or any other clinical parameter it correlated with the patients' mean SOFA- (p<0.0001, r = 0.69) and SAPS II-Score (p = 0.0005, r = 0.62). Patients who did not survive intensive care treatment displayed higher values of ELW in the initial CT scans. CONCLUSIONS: ELW could serve as a non-invasive method to quantify the amount of pulmonary oedema. It might serve as an early radiological marker of severity in patients with ARDS.


Assuntos
Pulmão/diagnóstico por imagem , Edema Pulmonar/diagnóstico , Síndrome do Desconforto Respiratório/diagnóstico , Tomografia Computadorizada por Raios X , Adulto , Idoso , Estudos de Viabilidade , Feminino , Mortalidade Hospitalar , Humanos , Unidades de Terapia Intensiva/estatística & dados numéricos , Pulmão/fisiopatologia , Medidas de Volume Pulmonar/métodos , Masculino , Pessoa de Meia-Idade , Edema Pulmonar/etiologia , Edema Pulmonar/mortalidade , Edema Pulmonar/fisiopatologia , Síndrome do Desconforto Respiratório/complicações , Síndrome do Desconforto Respiratório/mortalidade , Síndrome do Desconforto Respiratório/fisiopatologia , Testes de Função Respiratória , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...