Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
Sensors (Basel) ; 24(9)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38733027

RESUMO

Heart failure (HF) is a complex clinical syndrome associated with significant morbidity, mortality, and healthcare costs. It is characterized by various structural and/or functional abnormalities of the heart, resulting in elevated intracardiac pressure and/or inadequate cardiac output at rest and/or during exercise. These dysfunctions can originate from a variety of conditions, including coronary artery disease, hypertension, cardiomyopathies, heart valve disorders, arrhythmias, and other lifestyle or systemic factors. Identifying the underlying cause is crucial for detecting reversible or treatable forms of HF. Recent epidemiological studies indicate that there has not been an increase in the incidence of the disease. Instead, patients seem to experience a chronic trajectory marked by frequent hospitalizations and stagnant mortality rates. Managing these patients requires a multidisciplinary approach that focuses on preventing disease progression, controlling symptoms, and preventing acute decompensations. In the outpatient setting, patient self-care plays a vital role in achieving these goals. This involves implementing necessary lifestyle changes and promptly recognizing symptoms/signs such as dyspnea, lower limb edema, or unexpected weight gain over a few days, to alert the healthcare team for evaluation of medication adjustments. Traditional methods of HF monitoring, such as symptom assessment and periodic clinic visits, may not capture subtle changes in hemodynamics. Sensor-based technologies offer a promising solution for remote monitoring of HF patients, enabling early detection of fluid overload and optimization of medical therapy. In this review, we provide an overview of the CardioMEMS device, a novel sensor-based system for pulmonary artery pressure monitoring in HF patients. We discuss the technical aspects, clinical evidence, and future directions of CardioMEMS in HF management.


Assuntos
Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Cardiologia/métodos , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Gerenciamento Clínico , Hemodinâmica/fisiologia
2.
Diagnostics (Basel) ; 14(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38535042

RESUMO

In patients with premature ventricular contractions (PVCs), non-invasive mapping could locate the PVCs' origin on a personalized 3-dimensional (3D) heart model and, thus, facilitate catheter ablation therapy planning. The aim of our report is to evaluate its accuracy compared to invasive mapping in terms of assessing the PVCs' early activation zone (EAZ). For this purpose, non-invasive electrocardiographic imaging (ECGI) was performed using the Amycard 01C system (EP Solutions SA, Switzerland) in three cases. In the first step, a multichannel ECG (up to 224 electrodes) was recorded, and the dominant PVCs were registered. Afterward, a cardiac computed tomography (in two cases) or magnetic resonance imaging (in one case) investigation was carried out acquiring non-contrast torso scans for 8-electrode strip visualization and contrast heart acquisition. For the reconstructed epi/endocardial meshes of the heart, non-invasive isochronal maps were generated for the selected multichannel ECG fragments. Then, the patients underwent an invasive electrophysiological study, and the PVCs' activation was evaluated by a 3D mapping system (EnSite NavX Precision, Abbott). Finally, using custom-written software, we performed 3D fusion of the non-invasive and invasive models and compared the resulting isochronal maps. A qualitative analysis in each case showed the same early localization of the dominant PVC on the endocardial surface when comparing the non-invasive and invasive isochronal maps. The distance from the EAZ to the mitral or tricuspid annulus was comparable in the invasive/non-invasive data (36/41 mm in case N1, 73/75 mm in case N2, 9/12 mm in case N3). The area of EAZ was also similar between the invasive/non-invasive maps (4.3/4.5 cm2 in case N1, 7.1/7.0 cm2 in case N2, 0.4/0.6 cm2 in case N3). The distances from the non-invasive to invasive earliest activation site were 4 mm in case N1, 7 mm in case N2, and 4 mm in case N3. Such results were appropriate to trust the clinical value of the preoperative data in these cases. In conclusion, the non-invasive identification of PVCs before an invasive electrophysiological study can guide clinical and interventional decisions, demonstrating appropriate accuracy in the estimation of focus origin.

3.
Open Heart ; 11(1)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38458770

RESUMO

The wearable cardioverter defibrillator (WCD) is becoming a more and more widely used instrument for the prevention of sudden cardiac death of patients either with a secondary prevention implantable cardioverter defibrillator indication or with a transient high risk of sudden cardiac death. Although clinical practice has demonstrated a benefit of protecting patients for a period as long as 3-6 months with such devices, the current European guidelines concerning ventricular arrhythmias and sudden cardiac death are still extremely restrictive in the patient selection in part because of the costs derived from such a prevention device, in part because of the lack of robust randomised trials.To illustrate expanded use cases for the WCD, four real-life clinical cases are presented where patients received the device slightly outside the established guidelines. These cases demonstrate the broader utility of WCDs in situations involving acute myocarditis, thyrotoxicosis, pre-excited atrial fibrillation and awaiting staging/prognosis of a lung tumour. The findings prompt expansion of the existing guidelines for WCD use to efficiently protect more patients whose risk of arrhythmic cardiac death is transient or uncertain. This could be achieved by establishing a European register of the patients who receive a WCD for further analysis.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Dispositivos Eletrônicos Vestíveis , Humanos , Cardioversão Elétrica/efeitos adversos , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Fibrilação Atrial/complicações
5.
EuroIntervention ; 19(10): e844-e855, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-37860860

RESUMO

BACKGROUND: In the prospective, multicentre, randomised TARGET All Comers study, percutaneous coronary intervention (PCI) with the FIREHAWK biodegradable-polymer sirolimus-eluting stent (BP-SES) was non-inferior to the durable-polymer everolimus-eluting stent (DP-EES) for the primary endpoint of target lesion failure (TLF) at 12 months. AIMS: We aimed to report the final study outcomes at 5 years. METHODS: Patients referred for PCI were randomised to receive either a BP-SES or DP-EES in a 1:1 ratio in 10 European countries. Randomisation was stratified by centre and ST-elevation myocardial infarction (STEMI) presentation, and clinical follow-up extended to 5 years. The primary endpoint was TLF (composite of cardiac death, target vessel myocardial infarction [MI], or ischaemia-driven target lesion revascularisation). Secondary endpoints included patient-oriented composite events (POCE; composite of all-cause death, all MI, or any revascularisation and its components). RESULTS: From December 2015 to October 2016, 1,653 patients were randomly assigned to the BP-SES or DP-EES groups, of which 93.8% completed 5-year clinical follow-up or were deceased. At 5 years, TLF occurred in 17.1% of the BP-SES group and in 16.3% of the DP-EES group (p=0.68). POCE occurred in 34.0% of the BP-SES group and 32.7% of the DP-EES group (p=0.58). Revascularisation was the most common POCE, occurring in 19.3% of patients receiving BP-SES and 19.2% receiving DP-EES, of which less than one-third was ischaemia-driven target lesion-related. In the landmark analysis, there were no differences in the rates of TLF and POCE between groups from 1 to 5 years, and these results were consistent across all subgroups. CONCLUSIONS: In an all-comers population requiring stent implantation for myocardial ischaemia, the BP-SES was non-inferior to the DP-EES for the primary endpoint of TLF at 12 months, and results were sustained at 5 years, confirming the long-term safety and efficacy of the FIREHAWK BP-SES.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Sirolimo , Stents Farmacológicos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Implantes Absorvíveis , Everolimo , Infarto do Miocárdio/etiologia , Polímeros
6.
BMC Cardiovasc Disord ; 23(1): 176, 2023 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-37003986

RESUMO

BACKGROUND: A decade ago, the iopromide-paclitaxel coated balloon (iPCB) was added to the cardiologist's toolbox to initially treat in-stent restenosis followed by the treatment of de novo coronary lesions. In the meantime, DES technologies have been substantially improved to address in-stent restenosis and thrombosis, and shortened anti-platelet therapy. Recently, sirolimus-coated balloon catheters (SCB) have emerged to provide an alternative drug to combat restenosis. METHODS: The objective of this study is to determine the safety and efficacy of a novel crystalline sirolimus-coated balloon (cSCB) technology in an unselective, international, large-scale patient population. Percutaneous coronary interventions of native stenosis, in-stent stenosis, and chronic total occlusions with the SCB in patients with stable coronary artery disease or acute coronary syndrome were included. The primary outcome variable is the target lesion failure (TLF) rate at 12 months, defined as the composite rate of target vessel myocardial infarction (TV-MI), cardiac death or ischemia-driven target lesion revascularization (TLR). The secondary outcome variables include TLF at 24 months, ischemia driven TLR at 12 and 24 months and all-cause death, cardiac death at 12 and 24 months. DISCUSSION: Since there is a wealth of patient-based all-comers data for iPCB available for this study, a propensity-score matched analysis is planned to compare cSCB and iPCB for the treatment of de novo and different types of ISR. In addition, pre-specified analyses in challenging lesion subsets such as chronic total occlusions will provide evidence whether the two balloon coating technologies differ in their clinical benefit for the patient. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Identifier: NCT04470934.


Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Reestenose Coronária , Stents Farmacológicos , Humanos , Angioplastia/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Constrição Patológica/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Stents Farmacológicos/efeitos adversos , Paclitaxel/efeitos adversos , Sirolimo/efeitos adversos , Resultado do Tratamento , Ensaios Clínicos como Assunto
7.
Eur J Prev Cardiol ; 29(15): 1945-1954, 2022 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-35653582

RESUMO

AIMS: In Europe, global data on guideline adherence, geographic variations, and determinants of clinical events in patients with chronic coronary syndrome (CCS) remain suboptimal. The European Society of Cardiology (ESC) EURObservational Research Programme (EORP) Chronic Ischemic Cardiovascular Disease Long-Term (CICD-LT) registry is a prospective European registry, and was designed to describe the profile, management, and outcomes of patients with CCS across the ESC countries. METHODS AND RESULTS: We aimed to investigate clinical events at 1-year follow-up from the ESC EORP CICD-LT registry.One-year outcomes of 6655 patients from the 9174 recruited in this European registry were analysed. Overall, 168 patients (2.5%) died, mostly from cardiovascular (CV) causes (n = 97, 1.5%). Northern Europe had the lowest CV mortality rate, while southern Europe had the highest (0.5 vs. 2.0%, P = 0.04). Women had a higher rate of CV mortality compared with men (2.0 vs. 1.3%, P = 0.02). During follow-up, 1606 patients (27.1%) were hospitalized at least once, predominantly for CV indications (n = 1220, 20.6%). Among the population with measured low-density lipoprotein-cholesterol level at 1 year, 1434 patients (66.5%) were above the recommended target. Age, history of atrial fibrillation, previous stroke, liver disease, chronic obstructive pulmonary disease or asthma, increased serum creatinine, and impaired left ventricular function were associated with an increased risk of CV death or hospitalization. CONCLUSION: In the CICD registry, the majority of patients with CCS have uncontrolled CV-risk factors. The 1-year mortality rate is low, but these patients are frequently hospitalized for CV causes. Early identification of comorbidities may represent an opportunity for enhanced care and better outcomes.


Assuntos
Fibrilação Atrial , Cardiologia , Doenças Cardiovasculares , Masculino , Humanos , Feminino , Estudos Prospectivos , Síndrome , Sistema de Registros , Fibrilação Atrial/epidemiologia , Hospitalização , Doença Crônica , Europa (Continente)/epidemiologia , Fatores de Risco
8.
Sci Rep ; 12(1): 3606, 2022 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-35246595

RESUMO

Pace mapping and visual comparison of the local pacing response with the intrinsic QRS morphology form the mainstay of His bundle pacing (HBP). We evaluated the performance of a surface lead morphology match algorithm for automated classification of the pacing response in patients with narrow intrinsic QRS undergoing electroanatomic mapping (EAM)-guided HBP. HBP was attempted in 43 patients. In 28 cases with narrow QRS, the EnSite AutoMap Module was used for automated assessment of the QRS morphology resulting from pace mapping in the His cloud area with either a diagnostic catheter or the His lead. An intrinsic morphology match score (IMS) was calculated for 1.546 QRS complexes and assessed regarding its accuracy and performance in classifying the individual pacing response as either selective HBP (S-HBP), nonselective HBP (NS-HBP) or right ventricular stimulation. Automated morphology comparison of 354 intrinsic beats with the individual reference determined a test accuracy of 99% (95% CI 98.96-99.04) and a precision of 97.99-99.5%. For His-lead stimulation, an IMS ≥ 89% identified S-HBP with a sensitivity, specificity and positive predictive value of 1.00 (0.99, 1.00) and a negative predictive value of 0.99 (0.98, 1.00). An IMS between 78 and < 89% indicated NS-HBP with a sensitivity and specificity of 1.00 (0.99, 1.00) and 0.99 (0.98, 1.00), respectively. IMS represents a new automated measure for standardized individual morphology classification in patients with normal QRS undergoing EAM-guided HBP.Clinical trial registration: NCT04416958.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia , Ventrículos do Coração , Humanos , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
9.
Sensors (Basel) ; 21(24)2021 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-34960440

RESUMO

BACKGROUND: ICDs and pacemakers for cardiac resynchronization therapy (CRT) are complex devices with different sensors and automatic algorithms implanted in patients with advanced cardiac diseases. Data on the perioperative management and outcome of CRT carriers undergoing surgery unrelated to the device are scarce. METHODS: Data from 198 CRT device carriers (100 with active rate responsive sensor) were evaluated regarding perioperative adverse (device-related) events (A(D)E) and lead parameter changes. RESULTS: Thirty-nine adverse observations were documented in 180 patients during preoperative interrogation, which were most often related to the left-ventricular lead and requiring intervention/reprogramming in 22 cases (12%). Anesthesia-related events occurred in 69 patients. There was no ADE for non-cardiac surgery and in pacemaker-dependent patients not programmed to an asynchronous pacing mode. Post-operative device interrogation showed significant lead parameter changes in 64/179 patients (36%) requiring reprogramming in 29 cases (16%). CONCLUSION: The left-ventricular pacing lead represents the most vulnerable system component. Comprehensive pre and post-interventional device interrogation is mandatory to ensure proper system function. The type of ICD function suspension has no impact on each patient's outcome. Precautionary activity sensor deactivation is not required for non-cardiac interventions. Routine prophylactic device reprogramming to asynchronous pacing appears inessential. Most of the CRT pacemakers do not require surgery-related reprogramming.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Marca-Passo Artificial , Algoritmos , Insuficiência Cardíaca/terapia , Humanos , Resultado do Tratamento
10.
Heart Rhythm O2 ; 2(3): 262-270, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34337577

RESUMO

BACKGROUND: MicroFidelity catheter technology may facilitate voltage-guided ablation by high-resolution electroanatomic mapping (HR-EAM) and precisely targeted energy application. OBJECTIVE: To evaluate the performance of minielectrode (ME) technology for zero-fluoroscopy substrate-guided cavotricuspid isthmus (CTI) ablation. METHODS: Eighty-two patients underwent near zero-fluoroscopy substrate-guided CTI ablation using a nonirrigated large-tip catheter with 3 MEs. The CTI was subdivided into 15 electroanatomic segments. Bipolar voltage maps were compared with ME signals. The outcome was compared with a historic cohort of 92 patients who underwent linear ablation. RESULTS: Compared with linear ablation, the substrate-guided approach was associated with an almost halved ablation duration (336 ± 228 vs 649 ± 409 seconds, P < .001), halved radiofrequency energy applied (14.2 ± 10.6 vs 28.6 ± 19.6 kJ, P < .001), and shorter procedure duration (60.8 ± 33.8 vs 76.3 ± 40.9 minutes, P = .008) limiting the extent of energy delivery to 22.7% of the CTI area. HR-EAM visualized 2.03 ± 0.88 conductive pathways with a diameter of 5.35 ± 1.98 mm. A higher number of ME-detected bundles and a larger channel diameter correlated with increased ablation requirements. In 97.6% of the voltage-guided and 88.0% of the linear procedures, fluoroscopy was not used. CONCLUSION: HR-EAM-based substrate-guided CTI ablation may improve procedural outcome compared with the linear approach. Enhanced identification of discrete conductive pathways correlates with ablation efficacy. The electroanatomic subdivision of the CTI into 15 segments was feasible and may improve the understanding and comparability of anatomic variants and ablation results. Independent of the ablation strategy, modern EAM technology enables safe zero-fluoroscopy procedures in the majority of cases.

11.
Eur J Prev Cardiol ; 28(4): 432-445, 2021 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-33966083

RESUMO

BACKGROUND: International guidelines recommend pharmacotherapy combinations for chronic coronary syndromes (CCSs) but medical management remains suboptimal. DESIGN: The CICD-LT registry is investigating short- and long-term outcomes and management in patients in European Society of Cardiology (ESC) member countries, in a longitudinal ESC EURObservational Research Programme aimed at improving CCS management. METHODS: Between 1 May 2015 and 31 July 2018, 9174 patients with previous ST-elevation myocardial infarction (STEMI), non-STEMI or coronary revascularisation, or other CCS, were recruited during a routine ambulatory visit or elective revascularisation procedure. Baseline clinical data were recorded and prescribed medications analysed at initial contact and discharge, and according to patient gender and age (<75 vs. ≥75 years). RESULTS: Poorly controlled cardiovascular risk factors, including current smoking (18.5%), obesity (33.9%), diabetes (25.8%), raised low-density lipoprotein cholesterol (73.3%) and persistent hypertension (24.7%), were common across all cohorts. At ambulatory visit or admission, the guidelines-recommended combination of angiotensin-converting enzyme inhibitor/angiotensin receptor blocker, beta-blocker, aspirin, statin and any antiplatelet agent was prescribed to 57.8% of patients with STEMI/NSTEMI. Differences in prescribing rates, including for combination therapies, were observed based on age and gender and persisted after adjustment for demographic factors. CONCLUSIONS: Cardiovascular risk factors were common in contemporary CCS patients and secondary prevention prescribing was suboptimal. Patients aged ≥75 years and, to some extent, female patients were less likely to receive guidelines-recommended drug combinations than younger and male patients. One- and two-year follow-up will study prescribing changes and associations between baseline characteristics/prescribing and subsequent clinical outcomes.


Assuntos
Síndrome Coronariana Aguda , Cardiologia , Infarto do Miocárdio sem Supradesnível do Segmento ST , Infarto do Miocárdio com Supradesnível do Segmento ST , Feminino , Humanos , Masculino , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
12.
Respiration ; 100(2): 164-172, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33494091

RESUMO

BACKGROUND: Arterial blood gases are important when assessing acute or critically ill patients. Capillary blood and mathematical arterialization of venous blood have been proposed as alternative methods, eliminating pain and complications of arterial puncture. OBJECTIVES: This study compares the arterial samples, arterialized venous samples, and capillary samples in ICU and pulmonary ward patients. METHOD: Ninety-one adult patients with respiratory failure were included in the analysis. Arterial, peripheral venous, and mathematically arterialized venous samples were compared in all patients using Bland-Altman analysis, with capillary samples included in 36 patients. RESULTS: Overall for pH and PCO2, arterialized venous values, and in the subset of 36 patients, capillary values, compared well to arterial values and were within the pre-defined clinically acceptable differences (pH ± 0.05 and PCO2 ± 0.88 kPa). For PO2, arterialized or capillary values describe arterial with similar precision (PO2 arterialized -0.03, LoA -1.48 to 1.42 kPa and PO2 capillary 0.82, LoA -1.36 to 3 kPa), with capillary values underestimating arterial. CONCLUSIONS: Mathematical arterialization functions well in a range of patients in an ICU and ward outside the country of development of the method. Furthermore, accuracy and precision are similar to capillary blood samples. When considering a replacement for arterial sampling in ward patients, using capillary sampling or mathematical arterialization should depend on logistic ease of implementation and use rather than improved measurements of using either technique.


Assuntos
Gasometria/métodos , Dióxido de Carbono/sangue , Concentração de Íons de Hidrogênio , Conceitos Matemáticos , Oxigênio/sangue , Adulto , Idoso , Artérias , Estado Terminal , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Veias
13.
Clin Interv Aging ; 15: 723-731, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32546990

RESUMO

INTRODUCTION: The clinical benefit of invasive therapy in elderly patients with acute coronary syndrome (ACS) remains unclear. Furthermore, the decision-making process to treat this growing patient group is also debatable. The purpose of this study was to assess the association between elderly ACS patients, the treatment choice and their in-hospital outcomes after non-ST-elevation (NSTE)-ACS in a consecutive series of patients >75 years of age. METHODS AND RESULTS: Consecutive patients >75 years presenting with NSTE-ACS in our hospital between July 2017 and July 2018 were included during the first 2 days of hospital admission. Demographic data, prior medical history and present medical condition were documented. During day 0 and day 2, geriatric assessments (Clinical Frailty Scale [CFS], Barthel index, Charlson comorbidity index, "timed up and go" test [TUG], Mini-Mental Status Test [MMS], Geriatric Depression Scale [GDS], SF-36 for quality of life, instrumental activities of daily living [IADL], Killip-score, Grace-score and Euro-score) were conducted. After 6 months, patients were re-evaluated. In 106 patients (mean age 81.9±5.3 years, 57% male gender), 68 patients (64%) were treated interventionally, and 38 patients had conservative treatment (36%). Patients treated with intervention were significantly younger (80.9±4.7 years vs 83.5±6.0 years, p=0.015), had a lower rate of prior cerebral events (17.6% vs 26.3%; p=ns) and suffered more often from chronic obstructive pulmonary disease (17.6% vs 34.2%; p=0.050). All other demographic variables were comparable between both groups. The composite clinical endpoint (death, re-infarction, bleeding) was reached in 7 patients (10.3%) of the invasive and in 2 patients (5.3%) of the conservative group. They were not significantly different between both groups. A frailty index, consisting of commonly used parameters of functional impairment in elderly patients, namely, MMS ≤2 at baseline, IADL ≤7, CFS ≥7 and age ≥85 years, significantly predicted conservative treatment. CONCLUSION: Effective revascularization techniques are still underused in patients of older age in the case of ACS. For decision-making, geriatric tests alone may not predict treatment in those patients, but the combination of different tests may better predict treatment and perhaps the clinical outcomes in those patients. Furthermore, frail patients are at higher risk for not receiving guideline recommended therapy.


Assuntos
Tomada de Decisão Clínica , Fragilidade/epidemiologia , Múltiplas Afecções Crônicas/epidemiologia , Seleção de Pacientes , Infarto do Miocárdio com Supradesnível do Segmento ST , Fatores Etários , Idoso , Feminino , Avaliação Geriátrica/métodos , Humanos , Masculino , Revascularização Miocárdica/efeitos adversos , Revascularização Miocárdica/métodos , Avaliação de Resultados em Cuidados de Saúde , Prognóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia
14.
Pacing Clin Electrophysiol ; 43(7): 763-767, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32359082

RESUMO

In patients with persistent left superior vena cava (PLSVC), transvenous device implantation for cardiac resynchronization therapy (CRT) may be challenging. We present a complex case with successful, high-density electroanatomic mapping (EAM) guided corrective His bundle pacing (CHBP) following failed CRT upgrade in a patient with PLSVC, congenital heart disease, and pacing-associated heart failure. CHBP restored physiological conduction in left bundle branch block with complete conduction block leading to clinical improvement and cardiac remodeling. The presented case supports the growing evidence that EAM-guided CHBP may be considered a feasible alternative to conventional CRT when venous anatomy is not favorable for left ventricular lead implantation.


Assuntos
Fascículo Atrioventricular/fisiopatologia , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Mapeamento Epicárdico/métodos , Cardiopatias Congênitas/terapia , Insuficiência Cardíaca/terapia , Veia Cava Superior Esquerda Persistente/terapia , Idoso , Bloqueio de Ramo/fisiopatologia , Feminino , Cardiopatias Congênitas/fisiopatologia , Insuficiência Cardíaca/etiologia , Humanos , Veia Cava Superior Esquerda Persistente/fisiopatologia
15.
Ther Adv Cardiovasc Dis ; 14: 1753944720911329, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32168991

RESUMO

BACKGROUND: The objective of this review is to provide a practical update on endpoint selection for noninferiority (NI) studies in percutaneous coronary intervention studies. METHODS: A PubMed search was conducted for predefined terms to explore the use of NI designs and intrapatient comparisons to determine their current importance. Sample size calculations for the most frequently used endpoints with NI hypotheses were done to increase statistical awareness. RESULTS: Reported NI trials, with the most frequently chosen clinical endpoint of major adverse cardiac events (MACE), had NI margins ranging from 1.66% to 5.00%, resulting in patient populations of 400-1500 per treatment group. Clinical study endpoints comprising of MACE complemented with rates of bleeding complications and stent thrombosis (ST) are suggested to conduct a statistically and clinically meaningful NI trial. Study designs with surrogate endpoints amenable to intrapatient randomizations, are a very attractive option to reduce the number of necessary patients by about half. Comparative clinical endpoint studies with MACE and ST/bleeding rates to study a shortened dual antiplatelet therapy (DAPT) in coronary stent trials are feasible, whereas ST as the sole primary endpoint is not useful. CONCLUSIONS: Expanded composite clinical endpoints (MACE complemented by ST and bleeding rates and intrapatient randomization for selected surrogate endpoints) may be suitable tools to meet future needs in device approval, recertification and reimbursement.


Assuntos
Doença da Artéria Coronariana/terapia , Determinação de Ponto Final , Estudos de Equivalência como Asunto , Intervenção Coronária Percutânea , Projetos de Pesquisa , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária , Quimioterapia Combinada , Hemorragia/induzido quimicamente , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Inibidores da Agregação Plaquetária/administração & dosagem , Inibidores da Agregação Plaquetária/efeitos adversos , Fatores de Risco , Tamanho da Amostra , Stents , Fatores de Tempo , Resultado do Tratamento
16.
JACC Cardiovasc Interv ; 12(17): 1679-1687, 2019 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-31129092

RESUMO

OBJECTIVES: The aim of this study was to assess the 2-year clinical outcomes of the Firehawk stent (Shanghai MicroPort Medical Group, Shanghai, China), a novel abluminal groove-filled biodegradable-polymer sirolimus-eluting coronary stent, compared with XIENCE (Abbott Vascular, Santa Clara, California), a durable-polymer everolimus-eluting coronary stent. BACKGROUND: The long-term outcomes of the Firehawk stent have not been evaluated beyond 1 year in a randomized all-comers clinical trial. METHODS: The TARGET All Comers study is a prospective, multicenter, all-comers, randomized, noninferiority trial conducted in Europe. A total of 1,653 patients were randomly assigned to undergo implantation of either the Firehawk or the XIENCE stent. The primary endpoint was target lesion failure, a composite of cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization. RESULTS: At 2-year follow-up, the incidence of target lesion failure was 8.7% in the Firehawk group versus 8.6% in the XIENCE group (p = 0.92). The event rates of individual components of the primary endpoint were comparable for the 2 groups. Landmark analyses between 1- and 2-year follow-up revealed no statistically significant difference of TLF for the Firehawk versus the XIENCE stent. Beyond 1 year, very late definite or probable stent thrombosis occurred in 3 patients (0.4%) in the Firehawk group and in 7 patients (0.9%) in the XIENCE group (p = 0.34). CONCLUSIONS: The 2-year follow-up of the TARGET All Comers study confirms comparable safety and efficacy profiles of the Firehawk and XIENCE stents.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/administração & dosagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Terapia Antiplaquetária Dupla , Europa (Continente) , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
17.
Pharmacol Res ; 144: 257-263, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31026503

RESUMO

Quinidine has a very long history as antiarrhythmic medication. The alkaloid has been used in the treatment of almost all cardiac arrhythmias, especially atrial fibrillation, since the early twentieth century. Despite decreases in clinical prescription over the last two decades, mainly due to side effects like pro-arrhythmia, leading to increased mortality and to the availability of newer anti-arrhythmic drugs and catheter ablation, Quinidine remains an invaluable drug in the modern era of antiarrhythmic therapy. We present a review of the pharmacological properties of quinidine and its pivotal therapeutic role in the treatment of life-threatening arrhythmic storms in patients with congenital arrhythmogenic syndromes like Brugada's syndrome, early repolarization syndrome, short QT syndrome and idiopathic ventricular fibrillation.


Assuntos
Antiarrítmicos/uso terapêutico , Arritmias Cardíacas/tratamento farmacológico , Síndrome de Brugada/tratamento farmacológico , Quinidina/uso terapêutico , Fibrilação Ventricular/tratamento farmacológico , Animais , Antiarrítmicos/farmacologia , Humanos , Quinidina/farmacologia
18.
Clin Interv Aging ; 13: 1935-1943, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30349212

RESUMO

AIMS: There is limited evidence of the differences in expectations between elderly (≥80 years) and younger patients (<80 years) regarding treatment success of percutaneous coronary interventions (PCI). We conducted a survey in patients undergoing diagnostic coronary angiography (DA) and/or intervention (PCI) to identify differences in patient perceptions between elderly and younger patients. METHODS AND RESULTS: This is an all-comers study of consecutive patients who underwent DA and/or PCI. Patients were asked to fill out a questionnaire prior to DA/PCI. This questionnaire consisted of ten questions with potential patient expectations based on an increasing scale of importance from 0 to 5 which were related to the procedure (eg, extend life, decrease symptoms etc.) and the value of "hard" cardiac endpoints like death, stroke, acute myocardial infarction and target lesion revascularization for the patient. Among 200 patients (mean age 76.6±9.3 years, 60.5% male, ejection fraction 63.7%±13.2%), 100 patients (50%) were ≥80 years. For these elderly patients the questions "to remain independent," "to maintain mobility, so that I can maintain my current life," and "to prevent myocardial infarction" were rated highest. Regarding "hard" cardiac endpoints "to avoid PCI in the future" was rated lowest in younger and in elderly patients. Significant differences were found between the age groups with the items "to avoid myocardial infarction," "avoid heart insufficiency," "to extend my life" and "to maintain mobility so that I can maintain my current life" (P<0.001). CONCLUSIONS: In our survey we found significant differences in patient expectations between elderly and younger patients regarding the outcome of DA/PCI.


Assuntos
Angiografia Coronária/psicologia , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea/psicologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Atitude Frente a Saúde , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/psicologia , Procedimentos Cirúrgicos Eletivos/psicologia , Feminino , Humanos , Masculino , Infarto do Miocárdio/psicologia , Infarto do Miocárdio/terapia , Percepção Social , Inquéritos e Questionários , Resultado do Tratamento
19.
Lancet ; 392(10153): 1117-1126, 2018 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-30190206

RESUMO

BACKGROUND: The FIREHAWK is a drug-eluting stent with a fully biodegradable sirolimus-containing polymer coating localised to recessed abluminal grooves on the stent surface. We investigated clinical outcomes with this targeted, low-dose, biodegradable polymer, sirolimus-eluting stent compared with XIENCE durable polymer, everolimus-eluting stents in an all-comers population. METHODS: The TARGET All Comers study was a prospective, multicentre, open-label randomised non-inferiority trial done at 21 centres in ten European countries. Patients with symptomatic or asymptomatic coronary artery disease and objective evidence of myocardial ischaemia who qualified for percutaneous coronary intervention were randomised 1:1 to undergo implantation of a FIREHAWK or XIENCE. Randomisation was web-based, with random block allocation and stratification by centre and ST elevation myocardial infarction. Outcome assessors were masked to treatment allocation, but treating physicians and patients were not. The primary endpoint was target lesion failure at 12 months, a composite of cardiac death, target vessel myocardial infarction, or ischaemia-driven target lesion revascularisation. The control event rate for XIENCE was assumed to be 7%, the non-inferiority margin was 3.5%, and the primary analysis was in the intention-to-treat population, censoring patients who did not have either an event before 365 days or contact beyond 365 days. Late lumen loss was the primary endpoint of an angiographic substudy designed to investigate the non-inferiority of the FIREHAWK compared with the XIENCE stent. This trial is registered with ClinicalTrials.gov, number NCT02520180. FINDINGS: From Dec 17, 2015, to Oct 14, 2016, 1653 patients were randomly assigned to implantation of the FIREHAWK (n=823) or XIENCE (n=830). 65 patients in the FIREHAWK group and 66 in the XIENCE group had insufficient follow-up data and were excluded from the analyses. At 12 months, target lesion failure occurred in 46 (6·1%) of 758 patients in the FIREHAWK group and in 45 (5·9%) of 764 patients in the XIENCE group (difference 0·2%, 90% CI -1·9 to 2·2, pnon-inferiority=0·004, 95% CI -2·2 to 2·6, psuperiority=0·88). There were no differences in ischaemia-driven revascularisation or stent thrombosis rates at 12 months. 176 patients were included in the angiographic substudy, in which in-stent late lumen loss was 0·17 mm (SD 0·48) in the FIREHAWK group and 0·11 mm (0·52) in the XIENCE group (p=0·48), with an absolute difference of 0·05 mm (95% CI -0·09 to 0·18, pnon-inferiority=0·024). INTERPRETATION: In a broad all-comers population of patients requiring stent implantation for myocardial ischaemia, the FIREHAWK was non-inferior to the XIENCE as assessed with the primary endpoint of target lesion failure at 12 months and in-stent late lumen loss at 13 months. The FIREHAWK is a safe and effective alternative stent to treat patients with ischaemic coronary artery disease in clinical practice. FUNDING: Shanghai Microport Medical.


Assuntos
Implantes Absorvíveis , Stents Farmacológicos , Imunossupressores/administração & dosagem , Isquemia Miocárdica/cirurgia , Sirolimo/administração & dosagem , Idoso , Estudos de Equivalência como Asunto , Everolimo/administração & dosagem , Feminino , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
20.
Rev. esp. cardiol. (Ed. impr.) ; 71(8): 620-627, ago. 2018. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-178615

RESUMO

Introducción y objetivos: No se ha estudiado bien la incidencia y los predictores de la reestenosis recurrente tras angioplastia con balón farmacoactivo (BFA) en reestenois de stents farmacoactivos (SFA). Nuestro objetivo es analizar la incidencia y los predictores de la reestenosis recurrente en los estudios aleatorizados en que se utilizaron BFA para el tratamiento de la reestenosis del SFA. Métodos: Los datos clínicos y anatómicos de los pacientes incluidos en 6 estudios aleatorizados sobre BFA para el tratamiento de reestenosis de SFA se analizaron en conjunto. Se asignó a todos los pacientes incluidos en este análisis a tratamiento con el BFA de paclitaxel SeQuent Please (B Braun; Melsungen, Alemania). El análisis se centró en los pacientes que tenían seguimiento angiográfico a los 6-9 meses. Se evaluó tanto la incidencia de reestenosis (definida como estenosis ≥ 50% del diámetro luminal en el análisis por segmento durante el seguimiento angiográfico tardío) como sus predictores clínicos y angiográficos. Resultados: Los datos de 546 pacientes se incluyeron en una única base de datos. De 484 pacientes (88,6%), con un total de 518 lesiones tratadas, se disponía de seguimiento angiográfico tardío, y se detectó recurrencia de reestenosis en 101 pacientes (20,8%). En el análisis multivariable, la longitud de la lesión (por cada incremento de 5 mm, OR = 1,58; IC95%, 1,10-2,26; p = 0,012) y el tamaño del vaso (por cada reducción de 0,5 mm, OR = 1,42; IC95%, 1,12-1,79; p = 0,003) se asociaron de manera independiente con la recurrencia de reestenosis. Conclusiones: Este estudio, el mayor disponible de pacientes tratados con BFA por reestenosis de SFA con seguimiento angiográfico tardío, demuestra que la recurrencia de reestenosis se produce en 1 de cada 5 de estos pacientes. Los predictores de la reestenosis recurrente son la longitud de la lesión y el tamaño del vaso


Introduction and objectives: The incidence and predictors of recurrent restenosis after drug-coated balloon (DCB) angioplasty for drug-eluting stent (DES) restenosis remain poorly studied. We sought to evaluate the incidence and predictors of recurrent restenosis among participants in randomized controlled trials receiving DCB angioplasty for DES restenosis. Methods: The clinical and lesion data of individuals enrolled in 6 randomized controlled trials of DCB angioplasty for DES restenosis were pooled. All patients included in this report were assigned to receive paclitaxel-coated balloon angioplasty with the SeQuent Please DCB (B Braun, Melsungen, Germany). The current analysis focused on participants with available follow-up angiography at 6 to 9 months. The incidence of recurrent restenosis, defined as diameter restenosis ≥ 50% in the in-segment area at follow-up angiography, and its clinical and angiographic predictors were evaluated. Results: A total of 546 patients were combined in a single dataset. Angiographic follow-up at 6 to 9 months was available for 484 patients (88.6%) with 518 treated lesions. Recurrent restenosis was detected in 101 (20.8%) patients. On multivariable analysis, lesion length (OR, 1.58; 95%CI, 1.10-2.26; P = .012 for 5 mm increase) and vessel size (OR, 1.42; 95%, 1.12-1.79; P = .003 for 0.5 mm reduction) were independently associated with recurrent restenosis. Conclusions: In the largest cohort to date of individuals with angiographic surveillance after DCB angioplasty for DES restenosis, we demonstrated that recurrent restenosis occurs in approximately 1 out of 5 patients. Predictors of recurrent restenosis are increased lesion length and small vessel size


Assuntos
Humanos , Reestenose Coronária/fisiopatologia , Angioplastia Coronária com Balão , Stents Farmacológicos , Doença das Coronárias/complicações , Recidiva , Ponte de Artéria Coronária , Intervenção Coronária Percutânea , Paclitaxel/uso terapêutico , Infarto do Miocárdio/epidemiologia , Diabetes Mellitus/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...