RESUMO
OBJECTIVES: For the quantification of ß-hydroxybutyrate (BHB) and ß-hydroxy-ß-methylbutyrate (HMB) in human whole blood, a method using hydrophilic interaction liquid chromatography tandem mass spectrometry (HILIC-MS/MS) was developed, which does not require chemical modification of the analytes. DESIGN AND METHODS: Samples were deproteinised by a mixture of methanol and acetonitrile, and the extracts were cleaned-up using both polymeric strong cation exchange and strong anion exchange sorbents. The analytes and their structural isomers were separated using a column with a zwitterionic stationary phase. Isotope dilution of both analytes was used for quantitative analysis. RESULTS: Separation of BHB from isobaric interferences was achieved through chromatography. The relative intra-laboratory reproducibility standard deviations were better than 10% for blood samples at concentration levels of 10-20µM BHB and 1µM HMB and better than 5% at concentration levels 10 times higher. The mean true extraction recoveries were close to 100%. The trueness expressed as the relative bias of test results was within ±5% at concentration levels of 10-1000µM BHB and 1-20µM HMB. The lower limits of quantification were estimated to be 3µM for BHB and 0.4µM for HMB. CONCLUSIONS: A simple and highly sensitive and selective HILIC-MS/MS method was developed that is suitable for the quantification of BHB and HMB in whole blood.