Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Forensic Sci ; 69(2): 651-658, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38037231

RESUMO

Establishing the path or trajectory of a fired bullet is an often recurring part of shooting incident reconstruction. The current study describes how gravitational pull causes a systemic error on the vertical component of a trajectory reconstruction. Bullet drop, drop angle, and vertical offset are explained and calculated for 10 different handgun/ammunition combinations over a range of distances up to 100 m. The presented results are intended to provide forensic firearm examiners with a reference frame for the magnitude of error introduced on handgun bullet trajectory reconstructions over distance. Threshold values of 20 and 30 m are proposed as conservative distances up to where bullet trajectories can be modeled as straight lines with subsonic/transonic handgun bullets and with supersonic handgun bullets respectively. Both the bullet drop and vertical offset will be below 5 cm at these distances for those categories. The drop angle will be below 0.3°.

2.
Forensic Sci Int ; 313: 110363, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32590197

RESUMO

Firearm examination is subject to increased scrutiny regarding its foundational validity and inherent subjective nature. The increased use of automatic comparison systems may help to reduce subjectivity. In this paper, we present the performance and limits of an automatic comparison system that assigns a weight to the forensic findings for the comparisons between firing pin marks, breechface marks, or a combination of the two. This weight is expressed by a likelihood ratio (LR) based on 3D topographical measurements coupled with a bi-dimensional statistical model. As the performance of such systems may depend on the reference databases used to inform the model, we investigated the impact of the brand of ammunition and the number of samples. We show that reference databases used to calculate LRs should ideally consist of the same type of ammunition as is seen in the case under investigation and that 7 specimens fired by the same firearm are enough to obtain rates of misleading evidence of a similar magnitude compared to those obtained when far more specimens (60) are used. Additionally, the automatic system was used to assess the outcomes of 7 cases with known same-source or different-source ground truths. These cases were also examined by 8 qualified firearm examiners. In all cases, the experts' appraisals were in line with the ground truth. The automatic system showed some limitations in cases were the data were not sufficient to calculate a robust LR, but also that it can assist and enhance the examiners in their decision process.

3.
Int J Legal Med ; 134(3): 1007-1013, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31289933

RESUMO

Blunt abdominal organ injury is an abundant and relevant topic in forensic medicine, yet comparatively few experimental studies have been performed to quantify organ injury threshold parameters. The goal of this study was to relate an impact to a kidney injury determining an energy threshold while taking account of the influence of the overlaying soft tissue thickness. A model consisting of ballistic gelatin with an embedded filled porcine kidney was made such that a gelatin layer of 2 or 4 cm thickness covered the organ. An impactor was dropped on this model from different heights and the resulting organ damage was categorized according to the abbreviated injury scale (AIS). The 50% energy threshold for damage and the 50% energy threshold causing injuries ≥ AIS 3 were determined for the two protecting soft layers to be 22 J and 32 J and 27 J and 36 J, respectively. A finite element model was created to determine the strain energy densities at the depth of the organ's surface for these energies. The strain energy densities for the 50% damage thresholds were 88.9 mJ/cm3 and 86.7 mJ/cm3 for 2 and 4 cm and for the injuries ≥ AIS 3104.2 mJ/cm3 and 98.7 mJ/cm3. For forensic cases, this means that the thickness of the abdominal layers must be taken into account when the severity of an injury is used to draw conclusions about the applied impact strength.


Assuntos
Rim/lesões , Estresse Mecânico , Ferimentos não Penetrantes/patologia , Escala Resumida de Ferimentos , Animais , Fenômenos Biomecânicos , Análise de Elementos Finitos , Medicina Legal , Humanos , Modelos Biológicos , Suínos
4.
Forensic Sci Int ; 295: 137-144, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30599333

RESUMO

The Liberator is a firearm that can be manufactured from its blueprints by the means of a 3D-printer. This handgun is composed of nineteen pieces: eighteen made of printed polymer and one metallic nail. This study focuses on the physical traces which can be found and exploited from a forensic point of view after the discharging of such types of pistols. Two main aspects have been investigated: (1) whether it can be inferred that a 3D-printed handgun was used when investigating a scene; (2) when presuming the use of a 3D-printed Liberator on a scene. Six Liberators were manufactured, assembled and discharged. The discharge occurred under controlled conditions to allow the collection of ballistics data and traces produced by the shooting. Elements of ammunition - cartridge cases and projectiles - that were fired during an experimental campaign appeared to carry polymeric materials (flakes, melted polymer or both). Besides, we observed that the fired ammunition elements lacked traditional marks left by the metal pieces of a conventional firearm. Indeed, the projectiles did not carry rifling marks and the cartridge cases were found torn or swollen. Fragments or larger pieces of polymer were found, mostly on the ground, near the location of the discharge, up to nine metres away. The impression of the cartridge case head stamp was also found on a part of the Liberator called the "hammer body". This study showed that the discharge of a 3D-printed Liberator is expected to produce traces that can be transferred onto and recovered from the printed firearm, the cartridge case, the projectile, the target, and the environment of the discharge. These traces are different from those left by conventional firearms. When found on investigation scenes, some of these traces can inform on the use of a 3D-printed handgun and contribute to the reconstruction of a shooting event involving such a weapon. This study suggests that the approach adopted when investigating a scene must be adapted in terms of traceology when the use of such firearm is suspected.

5.
Forensic Sci Int ; 294: 150-159, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30529039

RESUMO

Synthetic models, also called "surrogates", are commonly used in wound ballistics in order to simulate human tissues. Despite several surrogates are worldwide accepted and used; some of them have not been yet fully validated and their limits for forensic reconstructions have not been deeply investigated yet. In this work we present a homicide/suicide case involving three gunshots to the head with bullets retained in the skull or beneath the scalp. Reconstruction of these cases was performed preparing three individual synthetic head models based on post-mortem computed tomography (PMCT) measurements. Ballistic soap, polyurethane plates and 10% ballistic gelatine at 4°C were used as simulants in individually adapted thickness. Ballistic tests were performed using the questioned firearm and ammunition type. The damages on the synthetic models have been compared to the findings in PMCT and autopsy of the victims. Although the results highlighted general similarities in terms of injury characteristics, some of the experimental shots overpenetrated. Furthermore, the bullets recovered in the synthetic models did not show the same quality of deformations as the questioned bullets. This lack of bullet deformation in the synthetic models might be mainly attributed to the physical difference between real bones and polyurethane surrogate.


Assuntos
Balística Forense/métodos , Modelos Biológicos , Ferimentos por Arma de Fogo , Estudos de Viabilidade , Gelatina , Traumatismos Cranianos Penetrantes/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Poliuretanos , Tomografia Computadorizada por Raios X , Ferimentos por Arma de Fogo/diagnóstico por imagem
6.
Forensic Sci Int ; 286: 245-251, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29602152

RESUMO

The Liberator is a firearm that can be manufactured from its blueprints, using a 3D-printer. This weapon made of nineteen pieces - eighteen in printed plastic and one metallic nail - raises questions such as its ability to fire a round, its wounding potential and the traces produced by its discharge. In particular, knowledge must be gained to infer that a 3D-printed handgun was used, reconstruct the shooting event involving such handgun, and gather information related to the type of 3D-printed handgun used. This study focused on the traces that could orientate forensic investigations when the use of a 3D-printed Liberator is suspected. In a first step, the Liberator was investigated to study its behaviour during the discharge and characterize traces produced by the discharge. To fulfil this goal, some Liberators were printed and assembled. Six Liberators fired a round. The discharge of the weapons was done under specific conditions allowing to collect ballistics data and traces produced by the shooting. The results showed that the barrel tended to break between the ignition of the primer and the moment the projectile exited the muzzle. The speed of the projectiles reached 140m/s when the barrel broke, while it was about 170m/s when barrel remained intact. The trajectory of the projectiles was sometimes disrupted, and the projectile tumbled on itself. It was thus very difficult to characterize the trajectory. The cavity wound caused by the fastest bullet was typical of a handgun wound firing a FMJ projectile (penetration of 21cm in ballistics soap). On the other hand, the cavity caused by the slowest bullet was more representative of a splinter wound (penetration of 14cm in ballistics soap). The study of gunshot residues collected on adhesive targets showed the presence of unburnt particles and small perforations caused by polymer pieces that concentrated around the entry holes.

7.
Meat Sci ; 135: 159-165, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29035813

RESUMO

Stock management of the Swiss water buffalo livestock results in the slaughtering of about 350 animals per year. As the stunning of water buffaloes still is an unresolved issue, we investigated the terminal ballistics of currently used perforating stunning devices. Cartridge fired captive bolt devices, handguns and a bullet casing gun were tested in a shooting steep by firing on bisected heads, forehead plates and soap blocks. Energy loss of captive bolts confirmed their inadequacy when used for heavy water buffaloes, notably adult males. As for the free projectiles, ballistics revealed that beyond the impact energy, bullet deformation has a strong impact on the outcome. Light 9mm Luger or .38 Spl bullets as well as large deformable .44 Rem. Magnum bullets should be avoided in favor of heavier .357 Magnum deformation ammunition. These data have been translated into the development of a new stunning device for water buffaloes meeting both animal welfare and occupational safety requirements.


Assuntos
Matadouros , Búfalos , Armas de Fogo/normas , Fatores Etários , Bem-Estar do Animal , Animais , Fenômenos Biomecânicos , Feminino , Cabeça , Masculino , Suíça
8.
Forensic Sci Int ; 271: 107-112, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28076837

RESUMO

The influence of the distance to the top and bottom of a gelatine block and to bullet tracks from previously fired shots on a bullet's trajectory, when passing through ballistic gelatine, was studied. No significant difference in deflection was found when trajectories of 9mm Luger bullets, fired at a 3.5cm distance to the top and bottom of a gelatine block and to bullet tracks from previously fired shots, were compared to trajectories of bullets fired 7cm or more away from any of the aforementioned aspects. A surprisingly consistent 6.5° absolute deflection angle was found when these bullets passed through 22.5 to 23.5cm of ballistic gelatine. The projection angle, determined by the direction of the deflection, appeared to be random. The consistent absolute angle, in combination with the random projection angle, resulted in a cone-like deflection pattern.

9.
J Forensic Sci ; 62(2): 417-422, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27921288

RESUMO

Subclass characteristics can be found on the breech face marks left on spent cartridge cases. Even if they are assumed to be rare and their reported number is small, they can potentially lead to false associations. Subclass characteristics have been studied empirically allowing examiners to recognize them and to understand in which conditions they are produced. Until now, however, their influence on the identification process has not been studied from a probabilistic point of view. In this study, we aim at measuring the effect of these features on the strength of association derived from examinations involving subclass characteristics. The study takes advantage of a 3D automatic comparison system allowing the calculation of likelihood ratios (LRs). The similarities between cartridge case specimens fired by thirteen S&W .40S&W Sigma pistols are quantified, and their respective LRs are computed. The results show that the influence of subclass characteristics on the LRs is limited, even when these features are prevalent among the potential sources considered in a case. We show that the proportion of firearms sharing subclass characteristics should be larger than 40% of the pool of potential firearms for the effect to be significant.

10.
Forensic Sci Int ; 270: 248-254, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27836412

RESUMO

Recently, quantitative MR sequences have started being used in post-mortem imaging. The goal of the present study was to evaluate if early acute and following age stages of myocardial infarction can be detected and discerned by quantitative 1.5T post-mortem cardiac magnetic resonance (PMCMR) based on quantitative T1, T2 and PD values. In 80 deceased individuals (25 female, 55 male), a cardiac MR quantification sequence was performed prior to cardiac dissection at autopsy in a prospective study. Focal myocardial signal alterations detected in synthetically generated MR images were MR quantified for their T1, T2 and PD values. The locations of signal alteration measurements in PMCMR were targeted at autopsy heart dissection and cardiac tissue specimens were taken for histologic examinations. Quantified signal alterations in PMCMR were correlated to their according histologic age stage of myocardial infarction. In PMCMR seventy-three focal myocardial signal alterations were detected in 49 of 80 investigated hearts. These signal alterations were diagnosed histologically as early acute (n=39), acute (n=14), subacute (n=10) and chronic (n=10) age stages of myocardial infarction. Statistical analysis revealed that based on their quantitative T1, T2 and PD values, a significant difference between all defined age groups of myocardial infarction can be determined. It can be concluded that quantitative 1.5T PMCMR quantification based on quantitative T1, T2 and PD values is feasible for characterization and differentiation of early acute and following age stages of myocardial infarction.


Assuntos
Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Miocárdio/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Temperatura Corporal , Estudos de Casos e Controles , Edema/patologia , Eosinofilia/patologia , Feminino , Fibroblastos/patologia , Patologia Legal , Granulócitos/patologia , Hemorragia/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Necrose , Fatores de Tempo
11.
Int J Legal Med ; 129(5): 1127-36, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26162597

RESUMO

The purpose of the present study was to investigate whether serous fluids, blood, cerebrospinal fluid (CSF), and putrefied CSF can be characterized and differentiated in synthetically calculated magnetic resonance (MR) images based on their quantitative T1, T2, and proton density (PD) values. Images from 55 postmortem short axis cardiac and 31 axial brain 1.5-T MR examinations were quantified using a quantification sequence. Serous fluids, fluid blood, sedimented blood, blood clots, CSF, and putrefied CSF were analyzed for their mean T1, T2, and PD values. Body core temperature was measured during the MRI scans. The fluid-specific quantitative values were related to the body core temperature. Equations to correct for temperature differences were generated. In a 3D plot as well as in statistical analysis, the quantitative T1, T2 and PD values of serous fluids, fluid blood, sedimented blood, blood clots, CSF, and putrefied CSF could be well differentiated from each other. The quantitative T1 and T2 values were temperature-dependent. Correction of quantitative values to a temperature of 37 °C resulted in significantly better discrimination between all investigated fluid mediums. We conclude that postmortem 1.5-T MR quantification is feasible to discriminate between blood, serous fluids, CSF, and putrefied CSF. This finding provides a basis for the computer-aided diagnosis and detection of fluids and hemorrhages.


Assuntos
Sangue , Líquidos Corporais , Líquido Cefalorraquidiano , Imageamento por Ressonância Magnética , Mudanças Depois da Morte , Temperatura Corporal , Encéfalo/patologia , Feminino , Patologia Legal , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Miocárdio/patologia , Pericárdio/patologia , Trombose/patologia
12.
J Forensic Sci ; 59(3): 637-47, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24502645

RESUMO

Recent years have been characterized by a series of publications in the field of firearms investigation questioning the reliability and objectivity of such examination. This research investigates new solutions to decrease the subjective component affecting the evaluation that follows the comparison of impressions left by a firearm on the surface of spent cartridge cases. An automatic comparison system based on 3D measurements has been developed and coupled to a bivariate evaluative model allowing assigning likelihood ratios. Based on a dataset of 79 pistols (all SIG Sauer 9 mm Luger caliber), the system shows a very high discriminating power and the LRs that it provides are very indicative of the true state under both the prosecution and the defense propositions. For example, likelihood ratios exceeding a billion are predominantly obtained when impressions originating from the same source are compared. The system is also characterized by relatively low rates (≤ 1%) of misleading evidence depending on the firearm considered.

13.
Forensic Sci Int ; 186(1-3): 29-35, 2009 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-19217228

RESUMO

Determining the time since discharge of spent cartridges found on a crime scene may be very useful in firearm investigations. The potential of small calibre munitions was barely studied in the past and this work did therefore focus on that problematic. The first step was to optimise the detection potential of solid-phase microextraction (SPME) followed by gas chromatography coupled to a mass spectrometry detector (GC/MS). This allowed determining the organic volatile composition of empty cartridges immediately after a gunshot. Identification of 32 detected compounds was confirmed by the analysis of reference substances. Preliminary aging studies over 32 h were carried out on selected target compounds to evaluate their potential to determine the time since discharge of empty cartridge cases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...