Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21252076

RESUMO

The rapid spread of COVID-19 and disruption of normal supply chains resulted in severe shortages of personal protective equipment (PPE), particularly devices with few suppliers such as powered air-purifying respirators (PAPRs). A scarcity of information describing design and performance criteria represents a substantial barrier to new approaches to address these shortages. We sought to apply open-source product development to PAPRs to enable alternative sources of supply and further innovation. We describe the design, prototyping, validation, and user testing of locally manufactured, modular, PAPR components, including filter cartridges and blower units, developed by the Greater Boston Pandemic Fabrication Team (PanFab). Two designs, one with a fully custom-made filter and blower unit housing, and the other with commercially available variants (the "Custom" and "Commercial" designs respectively) were developed. Engineering performance of the prototypes was measured and safety validated using NIOSH-equivalent tests on apparatus available under pandemic conditions, at university laboratories. Feedback on designs was obtained from four individuals, including two clinicians working in an ambulatory clinical setting and two research technical staff for whom PAPR use is a standard part of occupational PPE. Respondents rated the PanFab Custom PAPR a 4 to 5 on a 5 Likert-scale 1) as compared to current PPE options, 2) for the sense of security with use in a clinical setting, and 3) for comfort. The three other versions of the designs (with a commercial blower unit, filter, or both) performed favorably, with survey responses consisting of scores ranging from 3-5. Engineering testing and clinical feedback demonstrate that the PanFab designs represents favorable alternative PAPRs in terms of user comfort, mobility, and sense of security. A nonrestrictive license promotes innovation in respiratory protection for current and future medical emergencies.

2.
Surg Endosc ; 35(4): 1741-1748, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32323015

RESUMO

BACKGROUND: Lumen apposing metal stent (LAMS) allows an easy access to peripancreatic fluid collections (PPFCs) and the possibility of performing direct endoscopic necrosectomy (DEN). The aim of our study was to evaluate the safety and efficacy of a new 20-mm LAMS in the management of PPFCs. This novel stent represents the largest diameter LAMS available on the market to date. METHODS: This is an international, multicenter retrospective study involving 20 centers. Consecutive patients who underwent EUS-guided PPFC drainage using a 20-mm LAMS were included. Primary outcomes were technical and clinical success. Secondary outcomes were rate and the severity of adverse events. RESULTS: A total 105 patients underwent PPFC drainage using the new 20-mm LAMS and 106 LAMS were placed. Technical success was 100% (106/106). 7/105 patients died due to causes not related to the stent. Clinical success was achieved in 92/98 patients (93.9%). Significant adverse events occurred in 8/98 patients (8.16%): 4 cases (4.08%) of bleeding, 3 cases (3.06%) of suprainfection, 1 case of gastric outlet obstruction. CONCLUSIONS: This multicenter study demonstrated acceptable rates of technical and clinical success using a new 20-mm LAMS for PPFC, including walled-off pancreatic necrosis (WOPN). The results of our study suggest that a new 20-mm LAMS is non-inferior in terms of safety, efficacy, and adverse events as compared to smaller diameter LAMS in the management of PPFCs, including pancreatic psuedocysts (PP) and WOPN. Randomized controlled studies will be needed to determine the ideal size of LAMS need to achieve the greatest clinical benefit with the minimized risk exposure for this high-risk patient population.


Assuntos
Líquidos Corporais/química , Endoscopia , Internacionalidade , Pâncreas/patologia , Pâncreas/cirurgia , Stents/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Drenagem , Endossonografia , Hemorragia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...