Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomater Adv ; 153: 213537, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37406516

RESUMO

This paper is about the effects of reactive oxygen species (ROS) - and of their nanoparticle-mediated extracellular removal - in the TGF-ß1-induced differentiation of fibroblasts (human dermal fibroblasts - HDFa) to more contractile myofibroblasts, and in the maintenance of this phenotype. Here, poly(propylene sulfide) (PPS) nanoparticles have been employed on 2D and 3D in vitro models, showing extremely low toxicity and undergoing negligible internalization, thereby ensuring an extracellular-only action. Firstly, PPS nanoparticles abrogated ROS-mediated downstream molecular events such as glutathione oxidation, NF-κB activation, and heme oxidase-1 (HMOX) overexpression. Secondly, PPS nanoparticles were also capable to inhibit, prevent and reverse the TGF-ß1-induced upregulation of key biomechanical elements, such as ED-a fibronectin (EF-A FN) and alpha-smooth muscle actin (α-SMA), respectively markers of protomyofibroblastic and of myofibroblastic differentiation. We also confirmed that ROS alone are ineffective promoters of the myofibroblastic transition, although their presence contributes to its stabilization. Finally, the particles also countered TGF-ß1-induced matrix- and tissue-level phenomena, e.g., the upregulation of collagen type 1, the development of aberrant collagen type 1/3 ratios and the contracture of HDFa 3D-seeded fibrin constructs. In short, experimental data at molecular, cellular and tissue levels show a significant potential in the use of PPS nanoparticles as anti-fibrotic agents.


Assuntos
Miofibroblastos , Fator de Crescimento Transformador beta1 , Humanos , Miofibroblastos/patologia , Fator de Crescimento Transformador beta1/farmacologia , Espécies Reativas de Oxigênio/farmacologia , Fibroblastos , Fibrose , Colágeno Tipo I/farmacologia
2.
Adv Healthc Mater ; 12(24): e2300732, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37310792

RESUMO

Cochlear implants are a life-changing technology for those with severe sensorineural hearing loss, partially restoring hearing through direct electrical stimulation of the auditory nerve. However, they are known to elicit an immune response resulting in fibrotic tissue formation in the cochlea that is linked to residual hearing loss and suboptimal outcomes. Intracochlear fibrosis is difficult to track without postmortem histology, and no specific electrical marker for fibrosis exists. In this study, a tissue-engineered model of cochlear fibrosis is developed following implant placement to examine the electrical characteristics associated with fibrotic tissue formation around electrodes. The model is characterized using electrochemical impedance spectroscopy and an increase in the resistance and a decrease in capacitance of the tissue using a representative circuit are found. This result informs a new marker of fibrosis progression over time that is extractable from voltage waveform responses, which can be directly measured in cochlear implant patients. This marker is tested in a small sample size of recently implanted cochlear implant patients, showing a significant increase over two postoperative timepoints. Using this system, complex impedance is demonstrated as a marker of fibrosis progression that is directly measurable from cochlear implants to enable real-time tracking of fibrosis formation in patients, creating opportunities for earlier treatment intervention to improve cochlear implant efficacy.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Impedância Elétrica , Cóclea/fisiologia , Implante Coclear/efeitos adversos , Fibrose
3.
Ann Biomed Eng ; 51(7): 1390-1407, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37087541

RESUMO

As the first clinically translated machine-neural interface, cochlear implants (CI) have demonstrated much success in providing hearing to those with severe to profound hearing loss. Despite their clinical effectiveness, key drawbacks such as hearing damage, partly from insertion forces that arise during implantation, and current spread, which limits focussing ability, prevent wider CI eligibility. In this review, we provide an overview of the anatomical and physical properties of the cochlea as a resource to aid the development of accurate models to improve future CI treatments. We highlight the advancements in the development of various physical, animal, tissue engineering, and computational models of the cochlea and the need for such models, challenges in their use, and a perspective on their future directions.


Assuntos
Implante Coclear , Implantes Cocleares , Animais , Cóclea/cirurgia , Audição , Resultado do Tratamento
4.
Biosensors (Basel) ; 12(11)2022 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-36354508

RESUMO

(1) Background: During a cochlear implant insertion, the mechanical trauma can cause residual hearing loss in up to half of implantations. The forces on the cochlea during the insertion can lead to this mechanical trauma but can be highly variable between subjects which is thought to be due to differing anatomy, namely of the scala tympani. This study presents a systematic investigation of the influence of different geometrical parameters of the scala tympani on the cochlear implant insertion force. The influence of these parameters on the insertion forces were determined by testing the forces within 3D-printed, optically transparent models of the scala tympani with geometric alterations. (2) Methods: Three-dimensional segmentations of the cochlea were characterised using a custom MATLAB script which parametrised the scala tympani model, procedurally altered the key shape parameters (e.g., the volume, vertical trajectory, curvature, and cross-sectional area), and generated 3D printable models that were printed using a digital light processing 3D printer. The printed models were then attached to a custom insertion setup that measured the insertion forces on the cochlear implant and the scala tympani model during a controlled robotic insertion. (3) Results: It was determined that the insertion force is largely unaffected by the overall size, curvature, vertical trajectory, and cross-sectional area once the forces were normalised to an angular insertion depth. A Capstan-based model of the CI insertion forces was developed and matched well to the data acquired. (4) Conclusion: By using accurate 3D-printed models of the scala tympani with geometrical alterations, it was possible to demonstrate the insensitivity of the insertion forces to the size and shape of the scala tympani, after controlling for the angular insertion depth. This supports the Capstan model of the cochlear implant insertion force which predicts an exponential growth of the frictional force with an angular insertion depth. This concludes that the angular insertion depth, rather than the length of the CI inserted, should be the major consideration when evaluating the insertion force and associated mechanical trauma caused by cochlear implant insertion.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Rampa do Tímpano/cirurgia , Implante Coclear/métodos , Cóclea/anatomia & histologia , Cóclea/cirurgia , Fenômenos Mecânicos
5.
Clin Otolaryngol ; 47(6): 641-649, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35833359

RESUMO

OBJECTIVE: To investigate the value of scalp surface potentials to identify and manage partial short circuits to ground in cochlear implant electrodes. DESIGN: A retrospective review of patients with suspected partial short circuits. MAIN OUTCOME MEASURE: Electrical output of individual electrodes was measured using scalp surface potentials for patients reporting a change in hearing function. Electrical output was compared to functional performance and impedance measurements to determine if devices with suspected partial short circuits were experiencing a decrease in performance as a result of reduced electrical output. Electrical output was checked in an artificial cochlea for two implants following explant surgery to confirm scalp surface potential results. RESULTS: All patients with suspected partial short circuits (n = 49) had reduced electrical output, a drop in impedances to approximately ½ of previously stable measurements or to below 2 kΩ, an atypical electrical field measurement (EFI) and a decline in hearing function. Only devices with an atypical EFI showed reduced electrical output. Results of scalp based surface potentials could be replicated in an artificial cochlea following explantation of the device. All explant reports received to date (n = 42) have confirmed partial short circuits, with an additional four devices failing integrity tests. CONCLUSION: Surface potential measurements can detect partial shorts and had 100% correlation with atypical EFI measurements, which are characteristic of a partial short to ground in this device. Surface potentials can help determine the degree to which the electrode array is affected, particularly when behavioural testing is limited or not possible.


Assuntos
Implante Coclear , Implantes Cocleares , Cóclea , Implante Coclear/métodos , Impedância Elétrica , Testes Auditivos , Humanos , Couro Cabeludo/cirurgia
6.
IEEE Trans Biomed Eng ; 69(11): 3300-3312, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35417340

RESUMO

GOAL: Advances in computational models of biological systems and artificial neural networks enable rapid virtual prototyping of neuroprostheses, accelerating innovation in the field. Here, we present an end-to-end computational model for predicting speech perception with cochlear implants (CI), the most widely-used neuroprosthesis. METHODS: The model integrates CI signal processing, a finite element model of the electrically-stimulated cochlea, and an auditory nerve model to predict neural responses to speech stimuli. An automatic speech recognition neural network is then used to extract phoneme-level speech perception from these neural response patterns. RESULTS: Compared to human CI listener data, the model predicts similar patterns of speech perception and misperception, captures between-phoneme differences in perceptibility, and replicates effects of stimulation parameters and noise on speech recognition. Information transmission analysis at different stages along the CI processing chain indicates that the bottleneck of information flow occurs at the electrode-neural interface, corroborating studies in CI listeners. CONCLUSION: An end-to-end model of CI speech perception replicated phoneme-level CI speech perception patterns, and was used to quantify information degradation through the CI processing chain. SIGNIFICANCE: This type of model shows great promise for developing and optimizing new and existing neuroprostheses.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Humanos , Percepção da Fala/fisiologia , Ruído , Nervo Coclear
7.
Biomater Adv ; 133: 112661, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35067436

RESUMO

Tissue contractures are processes of cell-mediated contraction, irreversible in nature and typically associated with fibrotic phenomena. Contractures can be reproduced in vitro; here, we have used a medium-throughput model based on fibroblast-seeded fibrin (the 'contracture well'). Firstly, we show how profoundly these processes depend on the location of the contractile cells: when on top of the material, fibroblasts produce an interfacial contracture (analog to capsular contraction around an implant), which tries and bends the construct; when seeded inside the material, they initiate a bulk contracture (analogue to a wound bed closure) that shrinks it from within. Secondly, we demonstrate that the interfacial and bulk contractures are also mechanically and biologically different processes. Thirdly, we show the potentially predictive value of this model, since it not only recapitulates the effect of pro-fibrotic factors (TGF-ß1 for dermal (myo)fibroblasts), but can also indicate the fibrotic potential of a given cell population (here, dystrophic myoblasts more fibrotic than healthy or genetically corrected ones), which may have important implications in the identification of appropriate therapies.


Assuntos
Contratura , Fibroblastos , Células Cultivadas , Fibrose , Humanos , Mioblastos
8.
IEEE Trans Biomed Eng ; 68(7): 2281-2288, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33587694

RESUMO

Cochlear implants use electrical stimulation of the auditory nerve to restore the sensation of hearing to deaf people. Unfortunately, the stimulation current spreads extensively within the cochlea, resulting in "blurring" of the signal, and hearing that is far from normal. Current spread can be indirectly measured using the implant electrodes for both stimulating and sensing, but this provides incomplete information near the stimulating electrode due to electrode-electrolyte interface effects. Here, we present a 3D-printed "unwrapped" physical cochlea model with integrated sensing wires. We integrate resistors into the walls of the model to simulate current spread through the cochlear bony wall, and "tune" these resistances by calibration with an in-vivo electrical measurement from a cochlear implant patient. We then use this model to compare electrical current spread under different stimulation modes including monopolar, bipolar and tripolar configurations. Importantly, a trade-off is observed between stimulation amplitude and current focusing among different stimulation modes. By combining different stimulation modes and changing intracochlear current sinking configurations in the model, we explore this trade-off between stimulation amplitude and focusing further. These results will inform clinical strategies for use in delivering speech signals to cochlear implant patients.


Assuntos
Implante Coclear , Implantes Cocleares , Limiar Auditivo , Cóclea , Nervo Coclear , Estimulação Elétrica , Humanos
9.
Mater Sci Eng C Mater Biol Appl ; 118: 111433, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33255027

RESUMO

Polycaprolactone (PCL) scaffolds have been widely investigated for tissue engineering applications, however, they exhibit poor cell adhesion and mechanical properties. Subsequently, PCL composites have been produced to improve the material properties. This study utilises a natural material, Bombyx mori silk microparticles (SMP) prepared by milling silk fibre, to produce a composite to enhance the scaffolds properties. Silk is biocompatible and biodegradable with excellent mechanical properties. However, there are no studies using SMPs as a reinforcing agent in a 3D printed thermoplastic polymer scaffold. PCL/SMP (10, 20, 30 wt%) composites were prepared by melt blending. Rheological analysis showed that SMP loading increased the shear thinning and storage modulus of the material. Scaffolds were fabricated using a screw-assisted extrusion-based additive manufacturing system. Scanning electron microscopy and X-ray microtomography was used to determine scaffold morphology. The scaffolds had high interconnectivity with regular printed fibres and pore morphologies within the designed parameters. Compressive mechanical testing showed that the addition of SMP significantly improved the compressive Young's modulus of the scaffolds. The scaffolds were more hydrophobic with the inclusion of SMP which was linked to a decrease in total protein adsorption. Cell behaviour was assessed using human adipose derived mesenchymal stem cells. A cytotoxic effect was observed at higher particle loading (30 wt%) after 7 days of culture. By day 21, 10 wt% loading showed significantly higher cell metabolic activity and proliferation, high cell viability, and cell migration throughout the scaffold. Calcium mineral deposition was observed on the scaffolds during cell culture. Large calcium mineral deposits were observed at 30 wt% and smaller calcium deposits were observed at 10 wt%. This study demonstrates that SMPs incorporated into a PCL scaffold provided effective mechanical reinforcement, improved the rate of degradation, and increased cell proliferation, demonstrating potential suitability for bone tissue engineering applications.


Assuntos
Seda , Engenharia Tecidual , Humanos , Poliésteres , Porosidade , Impressão Tridimensional , Alicerces Teciduais
10.
Macromol Biosci ; 20(1): e1900283, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31769933

RESUMO

This review focuses on fibrin, starting from biological mechanisms (its production from fibrinogen and its enzymatic degradation), through its use as a medical device and as a biomaterial, and finally discussing the techniques used to add biological functions and/or improve its mechanical performance through its molecular engineering. Fibrin is a material of biological (human, and even patient's own) origin, injectable, adhesive, and remodellable by cells; further, it is nature's most common choice for an in situ forming, provisional matrix. Its widespread use in the clinic and in research is therefore completely unsurprising. There are, however, areas where its biomedical performance can be improved, namely achieving a better control over mechanical properties (and possibly higher modulus), slowing down degradation or incorporating cell-instructive functions (e.g., controlled delivery of growth factors). The authors here specifically review the efforts made in the last 20 years to achieve these aims via biomimetic reactions or self-assembly, as much via formation of hybrid materials.


Assuntos
Fibrina , Hidrogéis , Engenharia Tecidual , Alicerces Teciduais/química , Animais , Fibrina/química , Fibrina/uso terapêutico , Humanos , Hidrogéis/química , Hidrogéis/uso terapêutico
11.
Biotechnol Bioeng ; 116(7): 1698-1709, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30883678

RESUMO

Viral vectors such as adenovirus have successful applications in vaccines and gene therapy but the manufacture of the high-quality virus remains a challenge. It is desirable to use the adsorption-based chromatographic separations that so effectively underpin the therapeutic protein manufacture. However fundamental differences in the size and stability of this class of product mean it is necessary to revisit the design of sorbent's morphology and surface chemistry. In this study, the behaviour of a cellulose nanofiber ion-exchange sorbent derivatised with quaternary amine ligands at defined densities is characterised to address this. This material was selected as it has a large accessible surface area for viral particles and rapid process times. Initially, the impact of surface chemistry on infective product recovery using low (440 µmol/g), medium (750 µmol/g), and high (1029 µmol/g) ligand densities is studied. At higher densities product stability is reduced, this effect increased with prolonged adsorption durations of 24 min with just ~10% loss at low ligand density versus ~50% at high. This could be mitigated by using a high flow rate to reduce the cycle time to ~1 min. Next, the impact of ligand density on the separation's resolution was evaluated. Key to understanding virus quality is the virus particle: infectious virus particle ratio. It was found this parameter could be manipulated using ligand density and elution strategy. Together this provides a basis for viral vector separations that allows for their typically low titres and labile nature by using high liquid velocity to minimise both load and on-column times while separating key product and process-related impurities.


Assuntos
Adenoviridae/isolamento & purificação , Nanofibras/química , Vírion/isolamento & purificação , Adenoviridae/química , Cromatografia por Troca Iônica , Células HEK293 , Humanos , Vírion/química
12.
Mater Sci Eng C Mater Biol Appl ; 98: 266-278, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30813027

RESUMO

Carbon nanotubes (CNTs) with exceptional physical and chemical properties are attracting significant interest in the field of tissue engineering. Several reports investigated CNTs biocompatibility and their impact in terms of cell attachment, proliferation and differentiation mainly using polymer/CNTs membranes. However, these 2D membranes are not able to emulate the complex in vivo environment. In this paper, additive manufacturing (3D printing) is used to create composite 3D porous scaffolds containing different loadings of multi-walled carbon nanotubes (MWCNT) (0.25, 0.75 and 3 wt%) for bone tissue regeneration. Pre-processed and processed materials were extensively characterised in terms of printability, morphological and topographic characteristics and thermal, mechanical and biological properties. Scaffolds with pore sizes ranging between 366 µm and 397 µm were successfully produced and able to sustain early-stage human adipose-derived mesenchymal stem cells attachment and proliferation. Results show that MWCNTs enhances protein adsorption, mechanical and biological properties. Composite scaffolds, particularly the 3 wt% loading of MWCNTs, seem to be good candidates for bone tissue regeneration.


Assuntos
Regeneração Óssea/fisiologia , Nanotubos de Carbono/química , Impressão Tridimensional , Humanos , Porosidade , Engenharia Tecidual , Alicerces Teciduais/química
13.
APL Bioeng ; 2(3): 036102, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31069320

RESUMO

The invasion of a matrix by migrating cells is a key step in its remodelling. At least in 2D migration models, cells tend to localize in stiffer areas (durotaxis). Here, we show that mechanical properties affect differently the 3D migration rate: non-proteolytic 3D cell migration is facilitated in softer matrices. In these gels, the modulus was varied by introducing defects in fibres, leaving largely intact the nanostructure. The matrices derive from fibrin via functionalization with a bioinert polymer [poly(ethylene glycol), PEG] through an affinity mechanism identical to that presiding to fibrin own self-assembly. Peptidic end groups on PEG were used to bind fibrinogen globular D regions [GPRP (glycine-proline-arginine-proline) for a holes, GHRP (glycine-histidine-arginine-proline) for b holes; Kd evaluated via isothermal titration calorimetry or fluorescence anisotropy]. In a dose-dependent manner, both PEGylated peptides decreased gel stiffness, but most other properties at a macroscopic [e.g., overall elastic character, strain hardening, and high (>0.5) Poisson ratio] or nano/micro level (fibre dimension and pore size) were largely unaffected, suggesting that the softening effect was due to the introduction of defects within fibres, rather than to differences in the network architecture. In these matrices, the key determinant of fibroblast migration was found to be the elastic modulus, rather than the identity or the dose of the PEGylated peptide; softer materials allowed a faster invasion, even if this meant a higher content of non-adhesive PEG. This does not conflict with fibroblast durotaxis (where stiffness controls accumulation but not necessarily the speed of migration) and indicates a way to fine tune the speed of cell colonization.

14.
Biotechnol Lett ; 34(12): 2307-15, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22983716

RESUMO

The commercialisation of human embryonic stem cell derived cell therapies for large patient populations is reliant on both minimising expensive and variable manual-handling methods whilst realising economies of scale. The Quantum Cell Expansion System, a hollow fibre bioreactor (Terumo BCT), was used in a pilot study to expand 60 million human embryonic stem cells to 708 million cells. Further improvements can be expected with optimisation of media flow rates throughout the run to better control the cellular microenvironment. High levels of pluripotency marker expression were maintained on the bioreactor, with 97.7 % of cells expressing SSEA-4 when harvested.


Assuntos
Reatores Biológicos , Técnicas de Cultura de Células/métodos , Células-Tronco Embrionárias/fisiologia , Expressão Gênica , Humanos , Antígenos Embrionários Estágio-Específicos/biossíntese
15.
Pediatr Emerg Care ; 21(5): 325-6, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15874817

RESUMO

Traumatic posterior dislocation of the sternoclavicular joint is an uncommon injury in children. It is not normally well seen on plain films. We report 2 cases where spiral computed tomography with intravenous contrast confirmed the clinical suspicion of sternoclavicular joint dislocation and also allowed assessment of the adjacent mediastinum for possible complications. Emergency physicians should be aware that the use of spiral computed tomography is the procedure of choice in posterior sternoclavicular joint dislocation. This is particularly helpful in allowing multiplanar reconstruction to show complications arising in the mediastinum.


Assuntos
Luxações Articulares/diagnóstico por imagem , Articulação Esternoclavicular/diagnóstico por imagem , Articulação Esternoclavicular/lesões , Tomografia Computadorizada Espiral , Adolescente , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...