Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Phys J C Part Fields ; 84(1): 18, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38205101

RESUMO

High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optimized procedure results in a residual magnetic field that has been reduced by a factor of two. The ultra-low field is achieved with the full magnetic-field-coil system, and a large vacuum vessel installed, both in the MSR. In the inner volume of ∼1.4m3, the field is now more uniform and below 300 pT. In addition, the procedure is faster and dissipates less heat into the magnetic environment, which in turn, reduces its thermal relaxation time from 12h down to 1.5h.

2.
Eur Phys J C Part Fields ; 83(11): 1061, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38021215

RESUMO

We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5 m side length, magnetically shielded room (MSR) provides a passive, quasi-static shielding-factor of about 105 for its inner sensitive volume. The AMS consists of a system of eight complex, feedback-controlled compensation coils constructed on an irregular grid spanned on a volume of less than 1000 m3 around the MSR. The AMS is designed to provide a stable and uniform magnetic-field environment around the MSR, while being reasonably compact. The system can compensate static and variable magnetic fields up to ±50µT (homogeneous components) and ±5µT/m (first-order gradients), suppressing them to a few µT in the sub-Hertz frequency range. The presented design concept and implementation of the AMS fulfills the requirements of the n2EDM experiment and can be useful for other applications, where magnetically silent environments are important and spatial constraints inhibit simpler geometrical solutions.

3.
Phys Rev Lett ; 131(19): 191801, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-38000426

RESUMO

Models that postulate the existence of hidden sectors address contemporary questions, such as the source of baryogenesis and the nature of dark matter. Neutron-to-hidden-neutron oscillations are among the possible mixing processes and have been tested with ultracold neutron storage and passing-through-wall experiments to set constraints on the oscillation period τ_{nn^{'}}. These searches probe the oscillations as a function of the mass splitting due to the neutron-hidden-neutron energy degeneracy. In this work, we present a new limit derived from neutron disappearance in ultracold neutron beam experiments. The overall limit, given by τ_{nn^{'}}>1 s for |δm|∈[2,69] peV(95.45% C.L.), covers the yet unexplored intermediate mass-splitting range and contributes to the ongoing research on hidden sectors.

4.
Eur Phys J A Hadron Nucl ; 59(2): 15, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36751673

RESUMO

Muonic atom spectroscopy-the measurement of the x rays emitted during the formation process of a muonic atom-has a long standing history in probing the shape and size of nuclei. In fact, almost all stable elements have been subject to muonic atom spectroscopy measurements and the absolute charge radii extracted from these measurements typically offer the highest accuracy available. However, so far only targets of at least a few hundred milligram could be used as it required to stop a muon beam directly in the target to form the muonic atom. We have developed a new method relying on repeated transfer reactions taking place inside a 100 bar hydrogen gas cell with an admixture of 0.25% deuterium that allows us to drastically reduce the amount of target material needed while still offering an adequate efficiency. Detailed simulations of the transfer reactions match the measured data, suggesting good understanding of the processes taking place inside the gas mixture. As a proof of principle we demonstrate the method with a measurement of the 2p-1s muonic x rays from a 5  µ g gold target.

6.
Rev Sci Instrum ; 93(9): 095105, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36182526

RESUMO

We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute, which features an interior cubic volume with each side of length 2.92 m, thus providing an accessible space of 25 m3. The MSR has 87 openings of diameter up to 220 mm for operating the experimental apparatus inside and an intermediate space between the layers for housing sensitive signal processing electronics. The characterization measurements show a remanent magnetic field in the central 1 m3 below 100 pT and a field below 600 pT in the entire inner volume, up to 4 cm to the walls. The quasi-static shielding factor at 0.01 Hz measured with a sinusoidal 2 µT peak-to-peak signal is about 100 000 in all three spatial directions and increases rapidly with frequency to reach 108 above 1 Hz.

7.
Eur Phys J C Part Fields ; 81(6): 512, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34720721

RESUMO

We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnitude better sensitivity with provision for further substantial improvements. An overview is of the experimental method and setup is given, the sensitivity requirements for the apparatus are derived, and its technical design is described.

8.
Eur Phys J A Hadron Nucl ; 57(4): 152, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34776778

RESUMO

Psychological bias towards, or away from, prior measurements or theory predictions is an intrinsic threat to any data analysis. While various methods can be used to try to avoid such a bias, e.g. actively avoiding looking at the result, only data blinding is a traceable and trustworthy method that can circumvent the bias and convince a public audience that there is not even an accidental psychological bias. Data blinding is nowadays a standard practice in particle physics, but it is particularly difficult for experiments searching for the neutron electric dipole moment (nEDM), as several cross measurements, in particular of the magnetic field, create a self-consistent network into which it is hard to inject a false signal. We present an algorithm that modifies the data without influencing the experiment. Results of an automated analysis of the data are used to change the recorded spin state of a few neutrons within each measurement cycle. The flexible algorithm may be applied twice (or more) to the data, thus providing the option of sequentially applying various blinding offsets for separate analysis steps with independent teams. The subtle manner in which the data are modified allows one subsequently to adjust the algorithm and to produce a re-blinded data set without revealing the initial blinding offset. The method was designed for the 2015/2016 measurement campaign of the nEDM experiment at the Paul Scherrer Institute. However, it can be re-used with minor modification for the follow-up experiment n2EDM, and may be suitable for comparable projects elsewhere.

9.
Phys Rev Lett ; 116(18): 182501, 2016 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-27203316

RESUMO

The N=48 ^{80}Ge nucleus is studied by means of ß-delayed electron-conversion spectroscopy at ALTO. The radioactive ^{80}Ga beam is produced through the isotope separation on line photofission technique and collected on a movable tape for the measurement of γ and e^{-} emission following ß decay. An electric monopole E0 transition, which points to a 639(1) keV intruder 0_{2}^{+} state, is observed for the first time. This new state is lower than the 2_{1}^{+} level in ^{80}Ge, and provides evidence of shape coexistence close to one of the most neutron-rich doubly magic nuclei discovered so far, ^{78}Ni. This result is compared with theoretical estimates, helping to explain the role of monopole and quadrupole forces in the weakening of the N=50 gap at Z=32. The evolution of intruder 0_{2}^{+} states towards ^{78}Ni is discussed.

10.
Phys Rev Lett ; 115(16): 162502, 2015 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-26550870

RESUMO

We describe a spin-echo method for ultracold neutrons (UCNs) confined in a precession chamber and exposed to a |B0|=1 µT magnetic field. We have demonstrated that the analysis of UCN spin-echo resonance signals in combination with knowledge of the ambient magnetic field provides an excellent method by which to reconstruct the energy spectrum of a confined ensemble of neutrons. The method takes advantage of the relative dephasing of spins arising from a gravitationally induced striation of stored UCNs of different energies, and also permits an improved determination of the vertical magnetic-field gradient with an exceptional accuracy of 1.1 pT/cm. This novel combination of a well-known nuclear resonance method and gravitationally induced vertical striation is unique in the realm of nuclear and particle physics and should prove to be invaluable for the assessment of systematic effects in precision experiments such as searches for an electric dipole moment of the neutron or the measurement of the neutron lifetime.


Assuntos
Gravitação , Modelos Teóricos , Nêutrons , Temperatura Baixa , Cinética
11.
Opt Express ; 23(17): 22108-15, 2015 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-26368184

RESUMO

We present a magnetometer based on optically pumped Cs atoms that measures the magnitude and direction of a 1 µT magnetic field. Multiple circularly polarized laser beams were used to probe the free spin precession of the Cs atoms. The design was optimized for long-time stability and achieves a scalar resolution better than 300 fT for integration times ranging from 80 ms to 1000 s. The best scalar resolution of less than 80 fT was reached with integration times of 1.6 to 6 s. We were able to measure the magnetic field direction with a resolution better than 10 µrad for integration times from 10 s up to 2000 s.

12.
Phys Rev Lett ; 103(8): 081602, 2009 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-19792714

RESUMO

A clock comparison experiment, analyzing the ratio of spin precession frequencies of stored ultracold neutrons and 199Hg atoms, is reported. No daily variation of this ratio could be found, from which is set an upper limit on the Lorentz invariance violating cosmic anisotropy field b perpendicular < 2 x 10(-20) eV (95% C.L.). This is the first limit for the free neutron. This result is also interpreted as a direct limit on the gravitational dipole moment of the neutron |gn| < 0.3 eV/c2 m from a spin-dependent interaction with the Sun. Analyzing the gravitational interaction with the Earth, based on previous data, yields a more stringent limit |gn| < 3 x 10(-4) eV/c2 m.

13.
Phys Rev Lett ; 99(16): 161603, 2007 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-17995237

RESUMO

In case a mirror world with a copy of our ordinary particle spectrum would exist, the neutron n and its degenerate partner, the mirror neutron n', could potentially mix and undergo nn' oscillations. The interaction of an ordinary magnetic field with the ordinary neutron would lift the degeneracy between the mirror partners, diminish the n' amplitude in the n wave function and, thus, suppress its observability. We report an experimental comparison of ultracold neutron storage in a trap with and without superimposed magnetic field. No influence of the magnetic field is found and, assuming negligible mirror magnetic fields, a limit on the oscillation time taunn' > 103 s (95% C.L.) is derived.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...