RESUMO
Background: Periprocedural myocardial injury (PPMI) frequently occurs after transcatheter aortic valve implantation (TAVI), although its impact on long-term mortality is uncertain. Methods: We performed a pooled analysis of Kaplan-Meier-derived individual patient data to compare survival in patients with and without PPMI after TAVI. Flexible parametric models with B-splines and landmark analyses were used to determine PPMI prognostic value. Subgroup analyses for VARC-2, troponin, and creatine kinase-MB (CK-MB)-defined PPMI were also performed. Results: Eighteen observational studies comprising 10,094 subjects were included. PPMI was associated with lower overall survival (OS) after two years (HR = 1.46, 95% CI 1.30-1.65, p < 0.01). This was also observed when restricting the analysis to overall VARC-2-defined PPMI (HR = 1.23, 95% CI 1.07-1.40, p < 0.01). For VARC-2 PPMI criteria and VARC-2 troponin-only, higher mortality was restricted to the first 2 months after TAVI (HR = 1.64, 95% CI 1.31-2.07, p < 0.01; and HR = 1.32, 95% CI 1.05-1.67, p = 0.02, respectively), while for VARC-2 defined CK-MB-only the increase in mortality was confined to the first 30 days (HR = 7.44, 95% CI 4.76-11.66, p < 0.01). Conclusion: PPMI following TAVI was associated with lower overall survival compared with patients without PPMI. PPMI prognostic impact is restricted to the initial months after the procedure. The analyses were consistent for VARC-2 criteria and for both biomarkers, yet CK-MB was a stronger prognostic marker of mortality than troponin.
RESUMO
BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a worldwide adopted procedure with rapidly evolving practices. Regional and temporal variations are expected to be found. OBJECTIVE: To compare TAVR practice in Latin America with that around the world and to assess its changes in Latin America from 2015 to 2020. METHODS: A survey was applied to global TAVR centers between March and September 2015, and again to Latin-American centers between July 2019 and January 2020. The survey consisted of questions addressing: i) center's general information; ii) pre-TAVR evaluation; iii) procedural techniques; iv) post-TAVR management; v) follow-up. Answers from the 2015 survey of Latin-American centers (LATAM15) were compared with those of other centers around the world (WORLD15) and with the 2020 updated Latin-American survey (LATAM20). A 5% level of significance was adopted for statistical analysis. RESULTS: 250 centers participated in the 2015 survey (LATAM15=29; WORLD15=221) and 46 in the LATAM20. Combined centers experience accounted for 73 707 procedures, with WORLD15 centers performing, on average, 6- and 3-times more procedures than LATAM15 and LATAM20 centers, respectively. LATAM centers performed less minimalistic TAVR than WORLD15 centers, but there was a significant increase in less invasive procedures after 5 years in Latin-American centers. For postprocedural care, a lower period of telemetry and maintenance of temporary pacing wire, along with less utilization of dual antiplatelet therapy was observed in LATAM20 centers. CONCLUSION: Despite still having a much lower number of procedures, many aspects of TAVR practice in Latin-American centers have evolved in recent years, followingthe trend observed in developed country centers.
FUNDAMENTO: Implante transcateter de valva aórtica (TAVI) é um procedimento adotado em todo o mundo e suas práticas evoluem rapidamente. Variações regionais e temporais são esperadas. OBJETIVO: Comparar a prática de TAVI na América Latina com aquela no resto do mundo e avaliar suas mudanças na América Latina de 2015 a 2020. MÉTODO: A pesquisa foi realizada em centros de TAVI em todo o mundo entre março e setembro de 2015, e novamente nos centros latino-americanos entre julho de 2019 e janeiro de 2020. As seguintes questões foram abordadas: i) informação geral sobre os centros; ii) avaliação pré-TAVI; iii) técnicas do procedimento; iv) conduta pós-TAVI; v) seguimento. As respostas da pesquisa dos centros latino-americanos em 2015 (LATAM15) foram comparadas àquelas dos centros no resto do mundo (WORLD15) e ainda àquelas da pesquisa dos centros latino-americanos de 2020 (LATAM20). Adotou-se o nível de significância de 5% na análise estatística. RESULTADOS: 250 centros participaram da pesquisa em 2015 (LATAM15=29; WORLD15=221) e 46 na avaliação LATAM20. No total, foram 73.707 procedimentos, sendo que os centros WORLD15 realizaram, em média, 6 e 3 vezes mais procedimentos do que os centros LATAM15 e LATAM20, respectivamente. Os centros latino-americanos realizaram menor número de TAVI minimalista do que os do restante do mundo, mas aumentaram significativamente os procedimentos menos invasivos após 5 anos. Quanto à assistência pós-procedimento, observaram-se menor tempo de telemetria e de manutenção do marca-passo temporário, além de menor uso de terapia dupla antiplaquetária nos centros LATAM20. CONCLUSÃO: A despeito do volume de procedimentos ainda significativamente menor, muitos aspectos da prática de TAVI nos centros latino-americanos evoluíram recentemente, acompanhando a tendência dos centros dos países desenvolvidos.
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , América Latina , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do TratamentoRESUMO
Resumo Fundamento: Implante transcateter de valva aórtica (TAVI) é um procedimento adotado em todo o mundo e suas práticas evoluem rapidamente. Variações regionais e temporais são esperadas. Objetivo: Comparar a prática de TAVI na América Latina com aquela no resto do mundo e avaliar suas mudanças na América Latina de 2015 a 2020. Método: A pesquisa foi realizada em centros de TAVI em todo o mundo entre março e setembro de 2015, e novamente nos centros latino-americanos entre julho de 2019 e janeiro de 2020. As seguintes questões foram abordadas: i) informação geral sobre os centros; ii) avaliação pré-TAVI; iii) técnicas do procedimento; iv) conduta pós-TAVI; v) seguimento. As respostas da pesquisa dos centros latino-americanos em 2015 (LATAM15) foram comparadas àquelas dos centros no resto do mundo (WORLD15) e ainda àquelas da pesquisa dos centros latino-americanos de 2020 (LATAM20). Adotou-se o nível de significância de 5% na análise estatística. Resultados: 250 centros participaram da pesquisa em 2015 (LATAM15=29; WORLD15=221) e 46 na avaliação LATAM20. No total, foram 73.707 procedimentos, sendo que os centros WORLD15 realizaram, em média, 6 e 3 vezes mais procedimentos do que os centros LATAM15 e LATAM20, respectivamente. Os centros latino-americanos realizaram menor número de TAVI minimalista do que os do restante do mundo, mas aumentaram significativamente os procedimentos menos invasivos após 5 anos. Quanto à assistência pós-procedimento, observaram-se menor tempo de telemetria e de manutenção do marca-passo temporário, além de menor uso de terapia dupla antiplaquetária nos centros LATAM20. Conclusão: A despeito do volume de procedimentos ainda significativamente menor, muitos aspectos da prática de TAVI nos centros latino-americanos evoluíram recentemente, acompanhando a tendência dos centros dos países desenvolvidos.
Abstract Background: Transcatheter aortic valve replacement (TAVR) is a worldwide adopted procedure with rapidly evolving practices. Regional and temporal variations are expected to be found. Objective: To compare TAVR practice in Latin America with that around the world and to assess its changes in Latin America from 2015 to 2020. Methods: A survey was applied to global TAVR centers between March and September 2015, and again to Latin-American centers between July 2019 and January 2020. The survey consisted of questions addressing: i) center's general information; ii) pre-TAVR evaluation; iii) procedural techniques; iv) post-TAVR management; v) follow-up. Answers from the 2015 survey of Latin-American centers (LATAM15) were compared with those of other centers around the world (WORLD15) and with the 2020 updated Latin-American survey (LATAM20). A 5% level of significance was adopted for statistical analysis. Results: 250 centers participated in the 2015 survey (LATAM15=29; WORLD15=221) and 46 in the LATAM20. Combined centers experience accounted for 73 707 procedures, with WORLD15 centers performing, on average, 6- and 3-times more procedures than LATAM15 and LATAM20 centers, respectively. LATAM centers performed less minimalistic TAVR than WORLD15 centers, but there was a significant increase in less invasive procedures after 5 years in Latin-American centers. For postprocedural care, a lower period of telemetry and maintenance of temporary pacing wire, along with less utilization of dual antiplatelet therapy was observed in LATAM20 centers. Conclusion: Despite still having a much lower number of procedures, many aspects of TAVR practice in Latin-American centers have evolved in recent years, followingthe trend observed in developed country centers.
RESUMO
BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29 vs 4.89, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE (CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.
Assuntos
Endocardite , Substituição da Valva Aórtica TranscateterRESUMO
BACKGROUND: The role of direct oral anticoagulants as compared with vitamin K antagonists for atrial fibrillation after successful transcatheter aortic-valve replacement (TAVR) has not been well studied. METHODS: We conducted a multicenter, prospective, randomized, open-label, adjudicator-masked trial comparing edoxaban with vitamin K antagonists in patients with prevalent or incident atrial fibrillation as the indication for oral anticoagulation after successful TAVR. The primary efficacy outcome was a composite of adverse events consisting of death from any cause, myocardial infarction, ischemic stroke, systemic thromboembolism, valve thrombosis, or major bleeding. The primary safety outcome was major bleeding. On the basis of a hierarchical testing plan, the primary efficacy and safety outcomes were tested sequentially for noninferiority, with noninferiority of edoxaban established if the upper boundary of the 95% confidence interval for the hazard ratio did not exceed 1.38. Superiority testing of edoxaban for efficacy would follow if noninferiority and superiority were established for major bleeding. RESULTS: A total of 1426 patients were enrolled (713 in each group). The mean age of the patients was 82.1 years, and 47.5% of the patients were women. Almost all the patients had atrial fibrillation before TAVR. The rate of the composite primary efficacy outcome was 17.3 per 100 person-years in the edoxaban group and 16.5 per 100 person-years in the vitamin K antagonist group (hazard ratio, 1.05; 95% confidence interval [CI], 0.85 to 1.31; P = 0.01 for noninferiority). Rates of major bleeding were 9.7 per 100 person-years and 7.0 per 100 person-years, respectively (hazard ratio, 1.40; 95% CI, 1.03 to 1.91; P = 0.93 for noninferiority); the difference between groups was mainly due to more gastrointestinal bleeding with edoxaban. Rates of death from any cause or stroke were 10.0 per 100 person-years in the edoxaban group and 11.7 per 100 person-years in the vitamin K antagonist group (hazard ratio, 0.85; 95% CI, 0.66 to 1.11). CONCLUSIONS: In patients with mainly prevalent atrial fibrillation who underwent successful TAVR, edoxaban was noninferior to vitamin K antagonists as determined by a hazard ratio margin of 38% for a composite primary outcome of adverse clinical events. The incidence of major bleeding was higher with edoxaban than with vitamin K antagonists. (Funded by Daiichi Sankyo; ENVISAGE-TAVI AF ClinicalTrials.gov number, NCT02943785.).
Assuntos
4-Hidroxicumarinas/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Inibidores do Fator Xa/uso terapêutico , Piridinas/uso terapêutico , Tiazóis/uso terapêutico , Substituição da Valva Aórtica Transcateter , Vitamina K/antagonistas & inibidores , 4-Hidroxicumarinas/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Inibidores do Fator Xa/efeitos adversos , Feminino , Hemorragia Gastrointestinal/induzido quimicamente , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Mortalidade , Fenindiona/análogos & derivados , Fenindiona/uso terapêutico , Complicações Pós-Operatórias/prevenção & controle , Piridinas/efeitos adversos , Tiazóis/efeitos adversos , Tromboembolia/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversosRESUMO
BACKGROUND: No data exist about the characteristics of infective endocarditis (IE) post-transcatheter aortic valve replacement (TAVR) according to transcatheter valve type. We aimed to determine the incidence, clinical characteristics, and outcomes of patients with IE post-TAVR treated with balloon-expandable valve (BEV) versus self-expanding valve (SEV) systems. METHODS: Data from the multicenter Infectious Endocarditis After TAVR International Registry was used to compare IE patients with BEV versus SEV. RESULTS: A total of 245 patients with IE post-TAVR were included (SEV, 47%; BEV, 53%). The timing between TAVR and IE was similar between groups (SEV, 5.5 [1.2-15] months versus BEV, 5.3 [1.7-11.4] months; P=0.89). Enterococcal IE was more frequent in the SEV group (36.5% versus 15.4%; P<0.01), and vegetation location differed according to valve type (stent frame, SEV, 18.6%; BEV, 6.9%; P=0.01; valve leaflet, SEV, 23.9%; BEV, 38.5%; P=0.01). BEV recipients had a higher rate of stroke/systemic embolism (20.0% versus 8.7%, adjusted OR: 2.46, 95% CI: 1.04-5.82, P=0.04). Surgical explant of the transcatheter valve (SEV, 8.7%; BEV, 13.8%; P=0.21), and in-hospital death at the time of IE episode (SEV, 35.6%; BEV, 37.7%; P=0.74) were similar between groups. After a mean follow-up of 13±12 months, 59.1% and 54.6% of the SEV and BEV recipients, respectively, had died (P=0.66). CONCLUSIONS: The characteristics of IE post-TAVR, including microorganism type, vegetation location, and embolic complications but not early or late mortality, differed according to valve type. These results may help to guide the diagnosis and management of IE and inform future research studies in the field. (AU)
Assuntos
Sistema de Registros , Incidência , Endocardite , Substituição da Valva Aórtica TranscateterRESUMO
Coronary obstruction is a rare but life-threatening complication in patients undergoing transcatheter aortic valve replacement (TAVR). Aortic valve-in-valve (VIV) procedures to treat failed surgical bioprosthesis is associated with ~6-fold higher risk for coronary obstruction in certain situations. The primary mechanism consists in the occlusion of the coronary ostium by the dislodged leaflet from the bioprosthesis after deployment of the transcatheter heart valve (THV), which most commonly occurs during the index procedure, but in up to 1/3 of cases a delayed presentation ensues. The clinical presentation consists of severe hypotension and ECG changes in most of the patients, with very high mortality rates. Therefore, pre-procedural multi-slice computed tomography is crucial for identifying high-risk features, such as low coronary heights, shallow sinuses of Valsalva, and short virtual THV to coronary ostial distance (VTC). Also, some models of surgical bioprosthesis present an increased risk for this dreadful complication. Preemptive protective strategies with coronary wiring, with or without placement of an undeployed stent, could mitigate the risks associated with this complication in high-risk patients, even though studies are lacking. This review aims to take a clinical perspective on the challenges in avoiding this complication during VIV procedures.
RESUMO
BACKGROUND: The impact of preexisting left bundle branch block (LBBB) in transcatheter aortic valve replacement (TAVR) recipients is unknown. The aim of this study was to determine the impact of preexisting LBBB on clinical outcomes after TAVR. METHODS AND RESULTS: This multicenter study evaluated 3404 TAVR candidates according to the presence or absence of LBBB on baseline ECG. TAVR complications and causes of death were defined according to Valve Academic Research Consortium-2 definitions. Follow-up outpatient visits or telephone interviews were conducted at 30 days, 12 months, and yearly thereafter. Echocardiography examinations were performed at baseline, at hospital discharge, and at 1-year follow-up. Preexisting LBBB was present in 398 patients (11.7%) and was associated with an increased risk of permanent pacemaker implantation (PPI; 21.1% versus 14.8%; adjusted odds ratio, 1.51; 95% CI, 1.12-2.04) but not death (7.3% versus 5.5%; adjusted odds ratio, 1.33; 95% CI, 0.84-2.12) at 30 days. At a mean follow-up of 22±21 months, there were no differences between patients with and without preexisting LBBB in overall mortality (adjusted hazard ratio, 0.94; 95% CI, 0.75-1.18) and cardiovascular mortality (adjusted hazard ratio, 0.90; 95% CI, 0.68-1.21). In a subanalysis of 2421 patients without PPI at 30 days and with complete follow-up about the PPI, preexisting LBBB was not associated with an increased risk of PPI or sudden cardiac death. Patients with preexisting LBBB had a lower left ventricular ejection fraction (LVEF) at baseline and at 1-year follow-up ( P <0.001 for both), but those with low LVEF exhibited a similar increase in LVEF over time after TAVR compared with patients with no preexisting LBBB ( P=0.327). CONCLUSIONS: Preexisting LBBB significantly increased the risk of early (but not late) PPI after TAVR, without any significant effect on overall mortality or cardiovascular mortality. Preexisting LBBB was associated with lower LVEF pre-TAVR but did not prevent an increase in LVEF post-TAVR similar to patients without LBBB.
Assuntos
Valva Aórtica/cirurgia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial , Doenças das Valvas Cardíacas/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Brasil/epidemiologia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/mortalidade , Bloqueio de Ramo/fisiopatologia , Canadá/epidemiologia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/mortalidade , Ecocardiografia , Eletrocardiografia , Europa (Continente)/epidemiologia , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Marca-Passo Artificial , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do TratamentoRESUMO
BACKGROUND: The impact of preexisting left bundle branch block (LBBB) in transcatheter aortic valve replacement (TAVR) recipients is unknown. The aim of this study was to determine the impact of preexisting LBBB on clinical outcomes after TAVR. METHODS AND RESULTS: This multicenter study evaluated 3404 TAVR candidates according to the presence or absence of LBBB on baseline ECG. TAVR complications and causes of death were defined according to Valve Academic Research Consortium-2 definitions. Follow-up outpatient visits or telephone interviews were conducted at 30 days, 12 months, and yearly thereafter. Echocardiography examinations were performed at baseline, at hospital discharge, and at 1-year follow-up. Preexisting LBBB was present in 398 patients (11.7%) and was associated with an increased risk of permanent pacemaker implantation (PPI; 21.1% versus 14.8%; adjusted odds ratio, 1.51; 95% CI, 1.122.04) but not death (7.3% versus 5.5%; adjusted odds ratio, 1.33; 95% CI, 0.842.12) at 30 days. At a mean follow-up of 22±21 months, there were no differences between patients with and without preexisting LBBB in overall mortality (adjusted hazard ratio, 0.94; 95% CI, 0.751.18) and cardiovascular mortality (adjusted hazard ratio, 0.90; 95% CI, 0.681.21). In a subanalysis of 2421 patients without PPI at 30 days and with complete follow-up about the PPI, preexisting LBBB was not associated with an increased risk of PPI or sudden cardiac death. Patients with preexisting LBBB had a lower left ventricular ejection fraction (LVEF) at baseline and at 1-year follow-up (P <0.001 for both), but those with low LVEF exhibited a similar increase in LVEF over time after TAVR compared with patients with no preexisting LBBB (P=0.327). CONCLUSIONS: Preexisting LBBB significantly increased the risk of early (but not late) PPI after TAVR, without any significant effect on overall mortality or cardiovascular mortality. Preexisting LBBB was associated with lower LVEF pre-TAVR but did not prevent an increase in LVEF post-TAVR similar to patients without LBBB.
Assuntos
Bloqueio de Ramo , Substituição da Valva Aórtica Transcateter/estatística & dados numéricosRESUMO
OBJECTIVES: This study sought to assess the influence of baseline right bundle branch block (RBBB) on all-cause and cardiovascular mortality as well as sudden cardiac death (SCD) among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Few data exist regarding the late clinical impact of pre-existing RBBB in TAVR recipients. METHODS: A total of 3,527 patients (mean age 82 ± 8 years, 50.1% men) were evaluated according to the presence of RBBB on baseline electrocardiography. Intraventricular conduction abnormalities were classified according to the American Heart Association, American College of Cardiology Foundation, and Heart Rhythm Society recommendations for standardization and interpretation of the electrocardiogram. TAVR complications and causes of death were defined according to Valve Academic Research Consortium 2 definitions. RESULTS: RBBB was present on baseline electrocardiography in 362 patients (10.3%) and associated with higher 30-day rates of permanent pacemaker implantation (PPI) (40.1% vs. 13.5%; p < 0.001) and death (10.2% vs. 6.9%; p = 0.024). At a mean follow-up of 20 ± 18 months, pre-existing RBBB was independently associated with all-cause mortality (hazard ratio [HR]: 1.31; 95% confidence interval [CI]: 1.06 to 1.63; p = 0.014) and cardiovascular mortality (HR: 1.45; 95% CI: 1.11 to 1.89; p = 0.006) but not with SCD (HR: 0.71; 95% CI: 0.22 to 2.32; p = 0.57). Patients with pre-existing RBBB and without PPI at discharge from the index hospitalization had the highest 2-year risk for cardiovascular death (27.8%; 95% CI: 20.9% to 36.1%; log-rank p = 0.007). In a subanalysis of 1,245 patients without PPI at discharge from the index hospitalization and with complete follow-up regarding the need for PPI, pre-existing RBBB was independently associated with the composite of SCD and PPI (HR: 2.68; 95% CI: 1.16 to 6.17; p = 0.023). CONCLUSIONS: Pre-existing RBBB was found in 10% of TAVR recipients and was associated with poorer clinical outcomes. Patients with baseline RBBB without permanent pacemakers at hospital discharge may be at especially high risk for high-degree atrioventricular block and/or SCD during follow-up. Future studies should evaluate strategies aimed at the early detection of patients at risk for late development of high-degree atrioventricular block.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bloqueio de Ramo/mortalidade , Morte Súbita Cardíaca/epidemiologia , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Brasil/epidemiologia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Canadá/epidemiologia , Causas de Morte , Ecocardiografia , Eletrocardiografia , Europa (Continente)/epidemiologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Modelos de Riscos Proporcionais , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
OBJECTIVES: The aim of this study was to compare aspirin plus clopidogrel with aspirin alone as antithrombotic treatment following transcatheter aortic valve replacement (TAVR) for the prevention of ischemic events, bleeding events, and death. BACKGROUND: Few data exist on the optimal antithrombotic therapy following TAVR. METHODS: This was a randomized controlled trial comparing aspirin (80 to 100 mg/day) plus clopidogrel (75 mg/day) (dual antiplatelet therapy [DAPT]) versus aspirin alone (single-antiplatelet therapy [SAPT]) in patients undergoing TAVR with a balloon-expandable valve. The primary endpoint was the occurrence of death, myocardial infarction (MI), stroke or transient ischemic attack, or major or life-threatening bleeding (according to Valve Academic Research Consortium 2 definitions) within the 3 months following the procedure. The trial was prematurely stopped after the inclusion of 74% of the planned study population. RESULTS: A total of 222 patients were included, 111 allocated to DAPT and 111 to SAPT. The composite of death, MI, stroke or transient ischemic attack, or major or life-threatening bleeding tended to occur more frequently in the DAPT group (15.3% vs. 7.2%, p = 0.065). There were no differences between groups in the occurrence of death (DAPT, 6.3%; SAPT, 3.6%; p = 0.37), MI (DAPT, 3.6%; SAT, 0.9%; p = 0.18), or stroke or transient ischemic attack (DAPT, 2.7%; SAPT, 0.9%; p = 0.31) at 3 months. DAPT was associated with a higher rate of major or life-threatening bleeding events (10.8% vs. 3.6% in the SAPT group, p = 0.038). There were no differences between groups in valve hemodynamic status post-TAVR. CONCLUSIONS: This small trial showed that SAPT (vs. DAPT) tended to reduce the occurrence of major adverse events following TAVR. SAPT reduced the risk for major or life-threatening events while not increasing the risk for MI or stroke. Larger studies are needed to confirm these results. (Aspirin Versus Aspirin + Clopidogrel Following Transcatheter Aortic Valve Implantation: The ARTE Trial [ARTE], NCT01559298; Aspirin Versus Aspirin+Clopidogrel as Antithrombotic Treatment Following TAVI [ARTE], NCT02640794).
Assuntos
Valva Aórtica/cirurgia , Aspirina/administração & dosagem , Valvuloplastia com Balão , Fibrinolíticos/administração & dosagem , Próteses Valvulares Cardíacas , Inibidores da Agregação Plaquetária/administração & dosagem , Trombose/prevenção & controle , Ticlopidina/análogos & derivados , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Aspirina/efeitos adversos , Valvuloplastia com Balão/efeitos adversos , Canadá , Clopidogrel , Quimioterapia Combinada , Término Precoce de Ensaios Clínicos , Europa (Continente) , Feminino , Fibrinolíticos/efeitos adversos , Hemorragia/induzido quimicamente , Humanos , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/prevenção & controle , Estimativa de Kaplan-Meier , Masculino , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/prevenção & controle , Inibidores da Agregação Plaquetária/efeitos adversos , Desenho de Prótese , Fatores de Risco , América do Sul , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Trombose/diagnóstico , Trombose/etiologia , Trombose/mortalidade , Ticlopidina/administração & dosagem , Ticlopidina/efeitos adversos , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do TratamentoRESUMO
This study sought to assess the influence of baseline right bundle branch block (RBBB) on all-cause and cardiovascular mortality as well as sudden cardiac death (SCD) among patients undergoing transcatheter aortic valve replacement (TAVR). Few data exist regarding the late clinical impact of pre-existing RBBB in TAVR recipients. A total of 3,527 patients (mean age 82 8 years, 50.1% men) were evaluated according to the presence of RBBB on baseline electrocardiography. Intraventricular conduction abnormalities were classified according to the American Heart Association, American College of Cardiology Foundation, and Heart Rhythm Society recommendations for standardization and interpretation of the electrocardiogram. TAVR complications and causes of death were defined according to Valve Academic Research Consortium 2 definitions. RBBB was present on baseline electrocardiography in 362 patients (10.3%) and associated with higher 30-day rates of permanent pacemaker implantation (PPI) (40.1% vs. 13.5%; p < 0.001) and death (10.2% vs. 6.9%; p » 0.024). At a mean follow-up of 20 18 months, pre-existing RBBB was independently associated with all-cause mortality (hazard ratio [HR]: 1.31; 95% confidence interval [CI]: 1.06 to 1.63; p » 0.014) and cardiovascular mortality (HR: 1.45; 95% CI: 1.11 to 1.89; p » 0.006) but not with SCD (HR: 0.71; 95% CI: 0.22 to 2.32; p » 0.57). Patients with pre-existing RBBB and without PPI at discharge from the index hospitalization had the highest 2-year risk for cardiovascular death (27.8%; 95% CI: 20.9% to 36.1%; log-rank p » 0.007). In a subanalysis of 1,245 patients without PPI at discharge from the index hospitalization and with complete follow-up regarding the need for PPI, pre-existing RBBB was independently associated with the composite of SCD and PPI (HR: 2.68; 95% CI: 1.16 to 6.17; p » 0.023)
Assuntos
Bloqueio de Ramo , Implante de Prótese de Valva Cardíaca , Morte Súbita CardíacaRESUMO
BACKGROUND: Direct transcatheter aortic valve replacement (TAVR) is regarded as having potential advantages over TAVR with balloon aortic valve predilatation (BAVP) in reducing procedural complications, but there are few data to support this approach. METHODS AND RESULTS: Patients included in the Brazilian TAVR registry with CoreValve and Sapien-XT prosthesis were compared according to the implantation technique, with or without BAVP. Clinical and echocardiographic data were analyzed in overall population and after propensity score matching. A total of 761 consecutive patients (BAVP=372; direct-TAVR=389) were included. Direct-TAVR was possible in 99% of patients, whereas device success was similar between groups (BAVP=81.2% versus direct-TAVR=78.1%; P=0.3). No differences in clinical outcomes at 30 days and 1 year were observed, including all-cause mortality (7.6% versus 10%; P=0.25 and 18.1% versus 24.5%; P=0.07, respectively) and stroke (2.8% versus 3.8%; P=0.85 and 5.5% versus 6.8%; P=0.56, respectively). Nonetheless, TAVR with BAVP was associated with a higher rate of new onset persistent left bundle branch block with the CoreValve (47.7% versus 35.1%; P=0.01 at 1 year). Mean gradient and incidence of moderate/severe aortic regurgitation were similar in both groups at 1 year (11% versus 13.3%; P=0.57 and 9.8±5.5 versus 8.7±4.3; P=0.09, respectively). After propensity score matching analysis, all-cause mortality and stroke remained similar. By multivariable analysis, BAVP and the use of CoreValve were independent predictors of new onset persistent left bundle branch block. CONCLUSIONS: The 2 TAVR strategies, with or without BAVP, provided similar clinical and echocardiographic outcomes over a midterm follow-up although BAVP was associated with a higher rate of new onset persistent left bundle branch block, particularly in patients receiving a CoreValve.
Assuntos
Angioplastia Coronária com Balão/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Bloqueio de Ramo/etiologia , Causas de Morte , Feminino , Humanos , Masculino , Pontuação de Propensão , Sistema de Registros , Substituição da Valva Aórtica Transcateter/mortalidadeRESUMO
OBJECTIVES: This study sought to evaluate the outcomes of the early experience of transcatheter mitral valve replacement (TMVR) with balloon-expandable valves in patients with severe mitral annular calcification (MAC) and reports the first large series from a multicenter global registry. BACKGROUND: The risk of surgical mitral valve replacement in patients with severe MAC is high. There are isolated reports of successful TMVR with balloon-expandable valves in this patient population. METHODS: We performed a multicenter retrospective review of clinical outcomes of patients with severe MAC undergoing TMVR. RESULTS: From September 2012 to July of 2015, 64 patients in 32 centers underwent TMVR with compassionate use of balloon-expandable valves. Mean age was 73 ± 13 years, 66% were female, and mean Society of Thoracic Surgeons score was 14.4 ± 9.5%. The mean mitral gradient was 11.45 ± 4.4 mm Hg and the mean mitral area was 1.18 ± 0.5 cm(2). SAPIEN valves (Edwards Lifesciences, Irvine, California) were used in 7.8%, SAPIEN XT in 59.4%, SAPIEN 3 in 28.1%, and Inovare (Braile Biomedica, Brazil) in 4.7%. Access was transatrial in 15.6%, transapical in 43.8%, and transseptal in 40.6%. Technical success according to Mitral Valve Academic Research Consortium criteria was achieved in 46 (72%) patients, primarily limited by the need for a second valve in 11 (17.2%). Six (9.3%) had left ventricular tract obstruction with hemodynamic compromise. Mean mitral gradient post-procedure was 4 ± 2.2 mm Hg, paravalvular regurgitation was mild or absent in all. Thirty-day all-cause mortality was 29.7% (cardiovascular = 12.5% and noncardiac = 17.2%); 84% of the survivors with follow-up data available were in New York Heart Association functional class I or II at 30 days (n = 25). CONCLUSIONS: TMVR with balloon-expandable valves in patients with severe MAC is feasible but may be associated with significant adverse events. This strategy might be an alternative for selected high-risk patients with limited treatment options.
Assuntos
Calcinose/cirurgia , Cateterismo Cardíaco/métodos , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Valvuloplastia com Balão , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Calcinose/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Europa (Continente) , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , América do Norte , Seleção de Pacientes , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , América do Sul , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do TratamentoRESUMO
IMPORTANCE: Limited data exist on clinical characteristics and outcomes of patients who had infective endocarditis after undergoing transcatheter aortic valve replacement (TAVR). OBJECTIVE: To determine the associated factors, clinical characteristics, and outcomes of patients who had infective endocarditis after TAVR. DESIGN, SETTING, AND PARTICIPANTS: The Infectious Endocarditis after TAVR International Registry included patients with definite infective endocarditis after TAVR from 47 centers from Europe, North America, and South America between June 2005 and October 2015. EXPOSURE: Transcatheter aortic valve replacement for incidence of infective endocarditis and infective endocarditis for in-hospital mortality. MAIN OUTCOMES AND MEASURES: Infective endocarditis and in-hospital mortality after infective endocarditis. RESULTS: A total of 250 cases of infective endocarditis occurred in 20 006 patients after TAVR (incidence, 1.1% per person-year; 95% CI, 1.1%-1.4%; median age, 80 years; 64% men). Median time from TAVR to infective endocarditis was 5.3 months (interquartile range [IQR], 1.5-13.4 months). The characteristics associated with higher risk of progressing to infective endocarditis after TAVR was younger age (78.9 years vs 81.8 years; hazard ratio [HR], 0.97 per year; 95% CI, 0.94-0.99), male sex (62.0% vs 49.7%; HR, 1.69; 95% CI, 1.13-2.52), diabetes mellitus (41.7% vs 30.0%; HR, 1.52; 95% CI, 1.02-2.29), and moderate to severe aortic regurgitation (22.4% vs 14.7%; HR, 2.05; 95% CI, 1.28-3.28). Health care-associated infective endocarditis was present in 52.8% (95% CI, 46.6%-59.0%) of patients...
Assuntos
Endocardite , Endocardite Bacteriana , Substituição da Valva Aórtica TranscateterRESUMO
BackgroundDirect transcatheter aortic valve replacement (TAVR) is regarded as having potential advantages over TAVRwith balloon aortic valve predilatation (BAVP) in reducing procedural complications, but there are few data to supportthis approach. Methods and ResultsPatients included in the Brazilian TAVR registry with CoreValve and Sapien-XT prosthesis were compared according to the implantation technique, with or without BAVP. Clinical and echocardiographic data were analyzed in overall population and after propensity score matching. A total of 761 consecutive patients (BAVP=372;direct-TAVR=389) were included. Direct-TAVR was possible in 99% of patients, whereas device success was similarbetween groups (BAVP=81.2% versus direct-TAVR=78.1%; P=0.3). No differences in clinical outcomes at 30 daysand 1 year were observed, including all-cause mortality (7.6% versus 10%; P=0.25 and 18.1% versus 24.5%; P=0.07,respectively) and stroke (2.8% versus 3.8%; P=0.85 and 5.5% versus 6.8%; P=0.56, respectively). Nonetheless, TAVRwith BAVP was associated with a higher rate of new onset persistent left bundle branch block with the CoreValve (47.7%versus 35.1%; P=0.01 at 1 year). Mean gradient and incidence of moderate/severe aortic regurgitation were similar inboth groups at 1 year (11% versus 13.3%; P=0.57 and 9.8±5.5 versus 8.7±4.3; P=0.09, respectively). After propensityscore matching analysis, all-cause mortality and stroke remained similar. By multivariable analysis, BAVP and the use ofCoreValve were independent predictors of new onset persistent left bundle branch block...
Assuntos
Estenose da Valva Aórtica , Pontuação de Propensão , Valvuloplastia com BalãoRESUMO
BACKGROUND: Cardiac biomarker release signifying myocardial injury post-transcatheter aortic valve replacement (TAVR) is common, yet its clinical impact within a large TAVR cohort receiving differing types of valve and procedural approaches is unknown. OBJECTIVES: This study sought to determine the incidence, clinical impact, and factors associated with cardiac biomarker elevation post TAVR. METHODS: This multicenter study included 1,131 consecutive patients undergoing TAVR with balloon-expandable (58%) or self-expandable (42%) valves. Transfemoral and transapical (TA) approaches were selected in 73.1% and 20.3% of patients, respectively. Creatine kinase-myocardial band (CK-MB) measurements were obtained at baseline and at several time points within the initial 72 h post TAVR. Echocardiography was performed at baseline and at 6- to 12-month follow-up. RESULTS: Overall, 66% of the TAVR population demonstrated some degree of myocardial injury as determined by a rise in CK-MB levels (peak value: 1.6-fold [interquartile range (IQR): 0.9 to 2.8-fold]). A TA approach and major procedural complications were independently associated with higher peak of CK-MB levels (p < 0.01 for all), which translated into impaired systolic left ventricular function at 6 to 12 months post TAVR (p < 0.01). A greater rise in CK-MB levels independently associated with an increased 30-day, late (median of 21 [IQR: 8 to 36] months) overall and cardiovascular mortality (p < 0.001 for all). Any increase in CK-MB levels was associated with poorer clinical outcomes, and there was a stepwise rise in late mortality according to the various degrees of CK-MB increase after TAVR (p < 0.001). CONCLUSIONS: Some degree of myocardial injury was detected in two-thirds of patients post TAVR, especially in those undergoing TA-TAVR or presenting with major procedural complications. A greater rise in CK-MB levels associated with greater acute and late mortality, imparting a negative impact on left ventricular function.