Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 734
Filtrar
1.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38763211

RESUMO

INTRODUCTION AND OBJECTIVES: In patients undergoing percutaneous coronary intervention (PCI) in the workup for transcatheter aortic valve replacement (TAVR), the clinical impact of coronary revascularization complexity remains largely unknown. This study sought to examine the impact of PCI complexity on clinical outcomes after TAVR in patients undergoing PCI in the preprocedural workup. METHODS: This was a multicenter study including consecutive patients scheduled for TAVR with concomitant significant coronary artery disease. Complex PCI was defined as having at least 1 of the following features: 3 vessels treated, ≥ 3 stents implanted, ≥ 3 lesions treated, bifurcation with 2 stents implanted, total stent length > 60 mm, or chronic total occlusion. The rates of major adverse cardiac events (MACE), including cardiovascular mortality, myocardial infarction, and coronary revascularization were evaluated. RESULTS: A total of 1550 patients were included, of which 454 (29.3%) underwent complex PCI in the pre-TAVR workup. After a median follow-up period of 2 [1-3] years after TAVR, the incidence of MACE was 9.6 events per 100 patients-years. Complex PCI significantly increased the risk of cardiovascular death (HR, 1.44; 95%CI, 1.01-2.07), nonperiprocedural myocardial infarction (HR, 1.52; 95%CI, 1.04-2.21), and coronary revascularization (HR, 2.46; 95%CI, 1.44-4.20). In addition, PCI complexity was identified as an independent predictor of MACE after TAVR (HR, 1.44; 95%CI, 1.09-1.83; P = .009). CONCLUSIONS: In TAVR candidates with significant coronary artery disease requiring percutaneous treatment, complex revascularization was associated with a higher risk of MACE. The degree of procedural complexity should be considered a strong determinant of prognosis in the PCI-TAVR population.

2.
Eur J Clin Invest ; : e14241, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38767226

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is increasingly being used in younger patients and those with lower peri-procedural risk, meaning more patients will live long enough to experience structural valve deterioration (SVD) of the bioprosthesis, indicating repeated TAVI. Experience of repeated TAVI-transcatheter heart valve (THV) implantation into an index THV is limited. This registry aims to assess the peri-procedural and short-term safety, efficacy and durability of repeated TAVI. METHODS: The ReTAVI Prospective observational registry is an investigator-initiated, multicentre, international, prospective registry of patients undergoing repeated TAVI using balloon-expandable SAPIEN prosthesis to evaluate procedural and short-term safety, efficacy and durability as well as anatomical and procedural factors associated with optimal results. The registry will enrol at least 150 patients across 60 high-volume centres. Patients must be ≥18 years old, have had procedural success with their first TAVI, have index THV device failure, intend to undergo repeated TAVI and be considered suitable candidates by their local Heart Team. All patients will undergo a 30-day and 12-month follow-up. The estimated study completion is 2025. CONCLUSIONS: The registry will collect pre-, peri-, postoperative and 12-months data on patients undergoing repeated TAVI procedures with THVs for failure of the index THV and determine VARC-3-defined efficacy and safety at 30 days and functional outcome at 12 months. The registry will expand existing data sets and identify patient characteristics/indicators related to complications and clinical benefits for patients with symptomatic severe calcific degenerative aortic stenosis.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38736245

RESUMO

BACKGROUND: Malnutrition is associated with poor prognosis in several cardiovascular diseases; however, its role in patients with secondary mitral regurgitation (SMR) is poorly known. AIMS: To evaluate the impact of nutritional status, assessed using different scores, on clinical outcomes in patients with SMR undergoing transcatheter edge-to-edge repair (TEER) in a real-world setting. METHODS: A total of 658 patients with SMR and complete nutritional data were identified from the MIVNUT registry. Nutritional status has been assessed using controlling nutritional status index (CONUT), prognostic nutritional index (PNI), and geriatric nutritional risk index (GNRI) scores. Outcomes of interest were all-cause mortality and all-cause mortality or heart failure (HF) hospitalization. RESULTS: Any malnutrition grade was observed in 79.4%, 16.7%, and 47.9% of patients by using CONUT, PNI, and GNRI, respectively, while moderate to severe malnutrition was noted in 24.7%, 16.7%, and 25.6% of patients, respectively. At a median follow-up of 2.2 years, 212 patients (32.2%) died. Moderate-severe malnutrition was associated with a higher rate of all-cause mortality (HR: 2.46 [95% CI: 1.69-3.58], HR: 2.18 [95% CI: 1.46-3.26], HR: 1.97 [95% CI: 1.41-2.74] for CONUT, PNI, and GNRI scores, respectively). The combined secondary endpoint of all-cause mortality and HF rehospitalization occurred in 306 patients (46.5%). Patients with moderate-severe malnutrition had a higher risk of the composite endpoint (HR: 1.56 [95% CI: 1.20-2.28], HR: 1.55 [95% CI: 1.01-2.19], HR: 1.36 [95% CI: 1.02-1.80] for CONUT, PNI, and GNRI scores, respectively). After adjustment for multiple confounders, moderate-severe malnutrition remained independently associated with clinical outcomes. CONCLUSIONS: Moderate-severe malnutrition was common in patients with SMR undergoing TEER. It was independently associated with poor prognosis regardless of the different scores used.

4.
EuroIntervention ; 20(9): 591-601, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726722

RESUMO

BACKGROUND: Little is known about the occurrence of subclinical new-onset atrial fibrillation (NOAF) after transcatheter aortic valve implantation (TAVI). AIMS: We aimed to evaluate the incidence, predictors, and clinical impact of subclinical NOAF after TAVI. METHODS: This was a multicentre study, including patients with aortic stenosis (AS) and no previous atrial fibrillation undergoing TAVI, with continuous ambulatory electrocardiogram (AECG) monitoring after TAVI. RESULTS: A total of 700 patients (79±8 years, 49% female, Society of Thoracic Surgeons score 2.9% [1.9-4.0]) undergoing transarterial TAVI were included (85% balloon-expandable valves). AECG was started 1 (0-1) day after TAVI (monitoring time: 14121314 days). NOAF was detected in 49 patients (7%), with a median duration of 185 (43-421) minutes (atrial fibrillation burden of 0.7% [0.3-2.8]). Anticoagulation was started in 25 NOAF patients (51%). No differences were found in baseline or procedural characteristics, except for a higher AS severity in the NOAF group (peak gradient: no NOAF: 71.9±23.5 mmHg vs NOAF: 85.2±23.8 mmHg; p=0.024; mean gradient: no NOAF: 44.4±14.7 mmHg vs NOAF: 53.8±16.8 mmHg; p=0.004). In the multivariable analysis, the baseline mean transaortic gradient was associated with a higher risk of NOAF after TAVI (odds ratio 1.04, 95% confidence interval: 1.01-1.06 for each mmHg; p=0.006). There were no differences between groups in all-cause mortality (no NOAF: 4.7% vs NOAF: 0%; p=0.122), stroke (no NOAF: 1.4% vs NOAF: 2.0%; p=0.723), or bleeding (no NOAF: 1.9% vs NOAF: 4.1%; p=0.288) from the 30-day to 1-year follow-up. CONCLUSIONS: NOAF detected with AECG occurred in 7% of TAVI recipients and was associated with a higher AS severity. NOAF detection determined the start of anticoagulation therapy in about half of the patients, and it was not associated with an increased risk of clinical events at 1-year follow-up.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Eletrocardiografia Ambulatorial , Substituição da Valva Aórtica Transcateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Eletrocardiografia Ambulatorial/métodos , Fatores de Risco , Resultado do Tratamento
5.
ESC Heart Fail ; 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38773938

RESUMO

AIMS: Interatrial shunts are under evaluation as a treatment for heart failure (HF); however, their in vivo flow performance has not been quantitatively studied. We aimed to investigate the fluid dynamics properties of the 0.51 cm orifice diameter Ventura shunt and assess its lumen integrity with serial transesophageal echocardiography (TEE). METHODS AND RESULTS: Computational fluid dynamics (CFD) and bench flow tests were used to establish the flow-pressure relationship of the shunt. Open-label patients from the RELIEVE-HF trial underwent TEE at shunt implant and at 6 and 12 month follow-up. Shunt effective diameter (Deff) was derived from the vena contracta, and flow was determined by the continuity equation. CFD and bench studies independently validated that the shunt's discharge coefficient was 0.88 to 0.89. The device was successfully implanted in all 97 enrolled patients; mean age was 70 ± 11 years, 97% were NYHA class III, and 51% had LVEF ≤40%. Patency was confirmed in all instances, except for one stenotic shunt at 6 months. Deff remained unchanged from baseline at 12 months (0.47 ± 0.01 cm, P = 0.376), as did the trans-shunt mean pressure gradient (5.1 ± 3.9 mmHg, P = 0.316) and flow (1137 ± 463 mL/min, P = 0.384). TEE measured flow versus pressure closely correlated (R2 ≥ 0.98) with a fluid dynamics model. At 12 months, the pulmonary/systemic flow Qp/Qs ratio was 1.22 ± 0.12. CONCLUSIONS: When implanted in patients with advanced HF, this small interatrial shunt demonstrated predictable and durable patency and performance.

7.
Artigo em Inglês | MEDLINE | ID: mdl-38752971

RESUMO

BACKGROUND: The safety profile of transcatheter tricuspid valve (TTV) repair techniques is well established, but residual tricuspid regurgitation (TR) remains a concern. OBJECTIVES: The authors sought to assess the impact of residual TR severity post-TTV repair on survival. METHODS: We evaluated the survival rate at 2 years of 613 patients with severe isolated functional TR who underwent TTV repair in TRIGISTRY according to the severity of residual TR at discharge using a 3-grade (mild, moderate, and severe) or 4-grade scheme (mild, mild to moderate, moderate to severe, and severe). RESULTS: Residual TR was none/mild in 33%, moderate in 52%, and severe in 15%. The 2-year adjusted survival rates significantly differed between the 3 groups (85%, 70%, and 44%, respectively; restricted mean survival time [RMST]: P = 0.0001). When the 319 patients with moderate residual TR were subdivided into mild to moderate (n = 201, 33%) and moderate to severe (n = 118, 19%), the adjusted survival rate was also significantly different between groups (85%, 80%, 55%, and 44%, respectively; RMST: P = 0.001). Survival was significantly lower in patients with moderate to severe residual TR compared to patients with mild to moderate residual TR (P = 0.006). No difference in survival rates was observed between patients with no/mild and mild to moderate residual TR (P = 0.67) or between patients with moderate to severe and severe residual TR (P = 0.96). CONCLUSIONS: The moderate residual TR group was heterogeneous and encompassed patients with markedly different clinical outcomes. Refining TR grade classification with a more granular 4-grade scheme improved outcome prediction. Our results highlight the importance of achieving a mild to moderate or lower residual TR grade during TTV repair, which could define a successful intervention.

8.
Rev. esp. cardiol. (Ed. impr.) ; 77(5): 396-407, mayo 2024. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-JHG-73

RESUMO

Introducción y objetivos: Existen pocos datos acerca del impacto pronóstico de una clase funcional NYHA III-IV después del implante percutáneo de válvula aórtica (TAVI). El objetivo del estudio fue determinar la incidencia, los predictores y las implicaciones pronósticas de una clase NYHA III-IV al mes del TAVI.MétodosEstudio multicéntrico que incluyó a 3.462 pacientes sometidos a TAVI que recibieron dispositivos de nueva generación. Se compararon pacientes en clase funcional NYHA I-II frente a pacientes en clase NYHA III-IV al mes de seguimiento. Los predictores de clase NYHA III-IV a un mes se identificaron mediante regresión logística multivariante. La supervivencia se evaluó con el método de Kaplan-Meier y los factores asociados a peor pronóstico se identificaron mediante la regresión de Cox.ResultadosLa edad media de la población de estudio era de 80,3±7,3 años, con el 47% de mujeres y un valor mediano en la escala de la Society of Thoracic Surgeons del 3,8% [IQR, 2,5-5,8]). Un total de 208 pacientes (6%) presentaron NYHA III-IV al mes del TAVI. Los predictores de NYHA III-IV al mes fueron: NYHA basal III-IV (OR=1,76; IC95%, 1,08-2,89; p=0,02), enfermedad pulmonar obstructiva crónica (OR=1,80; IC95%, 1,13-2,83; p=0,01) e insuficiencia mitral severa post-TAVI (OR=2,00; IC95%, 1,21-3,31; p<0,01). Los pacientes en NYHA III-IV al mes del TAVI tenían un mayor riesgo de muerte (HR=3,68; IC95%, 2,39-5,70; p<0,01) y hospitalización por insuficiencia cardiaca (HR=6,00; IC95%, 3,76-9,60; p<0,01) durante el año que siguió al TAVI. (AU)


Introduction and objectives: There are scarce data on the factors associated with impaired functional status after transcatheter aortic valve replacement (TAVR) and its clinical impact. This study aimed to determine the incidence, predictors, and prognostic implications of impaired functional class (NYHA class III-IV) following TAVR.MethodsThis multicenter study included 3462 transarterial TAVR patients receiving newer generation devices. The patients were compared according to their NYHA class at 1 month of follow-up (NYHA I-II vs NYHA III-IV). A multivariate logistic regression was performed to identify the predictors of 30-day NYHA class III-IV. Patient survival was compared with the Kaplan-Meier method and factors associated with decreased survival were identified with Cox regression analysis.ResultsThe mean age of the study population was 80.3±7.3 years, with 47% of women, and a median Society of Thoracic Surgeons score of 3.8% [IQR, 2.5-5.8]. A total of 208 patients (6%) were in NYHA class III-IV 1 month after TAVR. Predictors of 30-day NYHA class III-IV were baseline NYHA class III-IV (OR, 1.76; 95%CI, 1.08-2.89; P=.02), chronic pulmonary obstructive disease (OR, 1.80; 95%CI, 1.13-2.83; P=.01), and post-TAVR severe mitral regurgitation (OR, 2.00; 95%CI, 1.21-3.31; P<.01). Patients in NYHA class III-IV 1 month after TAVR were at higher risk of death (HR, 3.68; 95%CI, 2.39-5.70; P<.01) and heart failure-related hospitalization (HR, 6.00; 95%CI, 3.76-9.60; P<.01) at 1-year follow-up. (AU)


Assuntos
Humanos , Valva Aórtica/cirurgia , Complicações Pós-Operatórias , Taxa de Sobrevida/tendências , Fatores de Tempo , Seguimentos , Fatores de Risco
9.
Eur J Heart Fail ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561314

RESUMO

AIMS: Heart failure (HF) outcomes remain poor despite optimal guideline-directed medical therapy (GDMT). We assessed safety, effectiveness, and transthoracic echocardiographic (TTE) outcomes during the 12 months after Ventura shunt implantation in the RELIEVE-HF open-label roll-in cohort. METHODS AND RESULTS: Eligibility required symptomatic HF despite optimal GDMT with ≥1 HF hospitalization in the prior year or elevated natriuretic peptides. The safety endpoint was device-related major adverse cardiovascular or neurological events at 30 days, compared to a prespecified performance goal. Effectiveness evaluations included the Kansas City Cardiomyopathy Questionnaire (KCCQ) at baseline, 1, 3, 6, and 12 months and TTE at baseline and 12 months. Overall, 97 patients were enrolled and implanted at 64 sites. Average age was 70 ± 11 years, 97% were in New York Heart Association class III, and half had left ventricular ejection fraction (LVEF) ≤40%. The safety endpoint was achieved (event rate 0%, p < 0.001). KCCQ overall summary score was improved by 12-16 points at all follow-up timepoints (all p < 0.004), with similar outcomes in patients with reduced and preserved LVEF. At 12 months, left ventricular end-systolic and end-diastolic volumes were reduced (p = 0.020 and p = 0.038, respectively), LVEF improved (p = 0.009), right ventricular end-systolic and end-diastolic areas were reduced (p = 0.001 and p = 0.030, respectively), and right ventricular fractional area change (p < 0.001) and tricuspid annular plane systolic excursion (p < 0.001) improved. CONCLUSION: Interatrial shunting with the Ventura device was safe and resulted in favourable clinical effects in patients with HF, regardless of LVEF. Improvements of left and right ventricular structure and function were consistent with reverse myocardial remodelling. These results would support the potential of this shunt device as a treatment for HF.

11.
Struct Heart ; 8(2): 100262, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38481716

RESUMO

Background: It is unknown whether bioprostheses used for transcatheter aortic valve implantation will have similar long-term durability as those used for surgical aortic valve replacement. Repetitive mechanical stress applied to the valve leaflets, particularly during diastole, is the main determinant of structural valve deterioration. Leaflet mechanical stress cannot be measured in vivo. The objective of this in vitro/in silico study was thus to compare the magnitude and regional distribution of leaflet mechanical stress in old vs new generations of self-expanding (SE) vs balloon expandable (BE) transcatheter heart valves (THVs). Methods: A double activation simulator was used for in vitro testing of two generations of SE THV (Medtronic CoreValve 26 mm and EVOLUT PRO 26 mm) and two generations of BE THV (Edwards SAPIEN 23 mm vs SAPIEN-3 23 mm). These THVs were implanted within a 21-mm aortic annulus. A noncontact system based on stereophotogammetry and digital image correlation with high spatial and temporal resolution (2000 img/sec) was used to visualize the valve leaflet motion and perform the three-dimensional analysis. A finite element model of the valve was developed, and the leaflet deformation obtained from the digital image correlation analysis was applied to the finite element model to calculate local leaflet mechanical stress during diastole. Results: The maximum von Mises leaflet stress was higher in early vs new THV generation (p < 0.05) and in BE vs SE THV (p < 0.05): early generation BE: 2.48 vs SE: 1.40 MPa; new generation BE: 1.68 vs SE: 1.07 MPa. For both types of THV, the highest values of leaflet stress were primarily observed in the upper leaflet edge near the commissures and to a lesser extent in the mid-portion of the leaflet body, which is the area where structural leaflet deterioration most often occurs in vivo. Conclusions: The results of this in vitro/in silico study suggest that: i) Newer generations of THVs have ∼30% lower leaflet mechanical stress than the early generations; ii) For a given generation, SE THVs have lower leaflet mechanical stress than BE THVs. Further studies are needed to determine if these differences between new vs early THV generations and between SE vs BE THVs will translate into significant differences in long-term valve durability in vivo.

12.
J Invasive Cardiol ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38489568

RESUMO

OBJECTIVES: Little is known about valve hemodynamic performance during the Evolut and Neo deployment course. We aimed to evaluate transvalvular mean and peak-to-peak gradients over several intraprocedural timepoints during TAVR with Evolut PRO+ (Medtronic) and Neo (Boston Scientific) systems. METHODS: This was single-center pilot sub-study from the SavvyWire EFficacy and SafEty in Transcatheter Aortic Valve Implantation Procedures (SAFE-TAVI) trial. Participants received either the Evolut PRO+ or Neo for native valve severe aortic stenosis and the SavvyWire (OpSens Medical) was used for device delivery, pacing, and continuous left ventricular and aortic pressure measurements. For the Evolut, evaluation was done for baseline, two-thirds of valve deployment (still recapturable), 90% of valve deployment (no longer recapturable), and post-deployment hemodynamics. For the Neo, analysis was done at baseline, after the first step (top-crown deployment), and at final status. RESULTS: Nineteen patients were included (Evolut = 15; Neo = 4). There were no statistically significant changes in peak-to-peak gradients (44 mm Hg [IQR:33-69] vs 43 mm Hg [IQR:26-62], P = .41) between baseline and two-thirds of valve deployment in the Evolut patients. There was a significant decrease in mean (40 mm Hg [IQR:32-54] vs 14 mm Hg [IQR:10-18], P less than .001) and peak-to-peak (43 mmHg [IQRS:26-62] vs 9 mm Hg [IQR:8-13], P less than .001) transvalvular gradients between two-thirds and 90% of valve deployment for Evolut. Neo patients exhibited a decrease in transvalvular gradients after top-crown deployment (42.5 mm Hg baseline vs 13 mm Hg). CONCLUSIONS: Transvalvular gradients did not vary between the point of "no-recapture" compared to baseline values in patients receiving the Evolut, whereas a significant reduction in transvalvular gradients was observed when the valve was deployed at 90% and fully deployed. The Neo valve was slightly obstructive after the first step of deployment.

13.
J Invasive Cardiol ; 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38446025

RESUMO

OBJECTIVES: Valve oversizing has been associated with reduced paravalvular leaks (PVL) and valve migration risk. However, no optimal cut-off oversizing value has been defined for the Evolut system (Medtronic). The aim of this study was to assess the relationship between the degree of oversizing and moderate-to-severe PVL and determine the optimal oversizing cut-off value. METHODS: We conducted a multicenter study that included 740 consecutive patients with multidetector computed tomography (CT) data. Valve size was selected according to manufacturer recommendations, with oversizing ranging from 10% to 30%. The primary endpoint was moderate-to-severe PVL. RESULTS: The median age was 84 years (79-87 years), with 58.4% women, and a median EuroSCORE II of 4.1% (2.4-7.3%). Moderate-to-severe PVL was observed in 7.0% of the patients. An inverse relationship was found between oversizing and both PVL (11.3%, 8.6%, 5.4%, and 2.7% for quartiles Q1 to Q4; P = .007) and the need for post-dilation (P = .016). The multivariable analysis showed an association between oversizing and PVL (OR: 0.915 for each 1%-increase, P = .002). The optimal oversizing cut-off value to predict PVL was 20%, and PVL was significantly higher in patients with oversizing less than 20% (10.5% vs.4.2%, P less than .001). There were no differences in major clinical events according to the degree of oversizing, and a higher oversizing did not translate into an increased risk of permanent pacemaker (18.4% vs18.3%, P = .976). CONCLUSIONS: In TAVR with the Evolut valve, a higher oversizing was associated with lower rates of moderate-to-severe PVL and a lower need for post-dilation, with no negative impact on procedural and early clinical outcomes. A 20% oversizing threshold could be suggested to reduce PVLs. Further prospective studies are warranted to validate optimal oversizing for this valve system.

14.
J Invasive Cardiol ; 36(2)2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38335504

RESUMO

OBJECTIVES: The SavvyWire(OpSens Medical) is a support wire for transcatheter aortic valve replacement (TAVR) procedures that, in addition to its dedicated left ventricle (LV) pacing capabilities, has a distal pressure sensor that measures live transvalvular hemodynamics during the procedure. We aimed to determine the safety, efficacy, and functionality of the SavvyWire during TAVR procedures in an all-comer population. METHODS: We performed a multicentric, prospective, observational, single-arm, all-comers registry of patients with symptomatic, severe aortic stenosis undergoing TAVR in 3 Canadian centers. Data were collected in a dedicated database, and pre-specified questionnaires were fulfilled by the heart team implanters after each procedure. RESULTS: A total of 60 patients were included (mean age: 78.6 ± 7.2 years; 51% women; mean Society of Thoracic Surgeons score: 2.2 ± 1.6%). TAVR was performed through a transfemoral approach in 90% of cases, and balloon- and self-expandable valves were used in 73% and 27% of patients, respectively. There were no cases of LV perforation, guidewire deformation, significant loss of capture, or major software malfunction. The rate of successful delivery of the TAVR system was 100%, and effective LV pacing was achieved in 98% of patients. The pre-TAVR mean gradient was 39 ± 14 mm Hg while the final post-TAVR gradient was 8 ± 5 mm Hg; the mean aortic systolic pressure during rapid pacing was 54 ± 12 mm Hg. In 97% of the TAVR procedures, SavvyWire's functionality was reported to be better or similar to other TAVR workhorse support wires. CONCLUSIONS: SavvyWire was safe, effective, and functional for live transvalvular hemodynamic evaluation and rapid pacing during TAVR procedures. More studies with larger sample sizes and comparison against different wires and gradient measurement methods are warranted.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Canadá , Hemodinâmica , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
15.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38276659

RESUMO

BACKGROUND: Current European guidelines support transcatheter aortic valve implantation (TAVI) in intermediate-to-low-risk patients ≥75 years-old, but its prognostic relevance is unknown. METHODS: Intermediate-to-low-risk (The Society of Thoracic Surgeons score <8%) patients enrolled in the HORSE registry were included. We compared the populations aged under 75 with those over 75. The primary endpoint was all-cause mortality. RESULTS: A total of 2685 patients were included: 280 (8.6%) < 75 and 2405 ≥ 75 years. Through a mean follow-up of 437 ± 381 days, 198 (8.2%) and 23 (8.2%) patients died in the two arms without statistically significant differences (log-rank p = 0.925). At Cox regression analysis, age did not predict the occurrence of all-cause death, neither as a continuous variable (HR 1.01, 95% CI 0.99-1.04, p = 0.294) nor dichotomizing according to the prespecified cutoff of 75 years (HR 0.97, 95% CI 0.63-1.51, p = 0.924). Time-to-event ROC curves showed low accuracy of age to predict all-cause mortality (area under the curve of 0.54 for both 1-year and 2-year outcomes). CONCLUSIONS: TAVI has comparable benefits across age strata for intermediate-to-low-risk patients. The age cutoff suggested by the current guidelines is not predictive of the risk of adverse events during hospital stays or of all-cause mortality through a mid-term follow-up.

16.
Struct Heart ; 8(1): 100227, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38283572

RESUMO

Bicuspid aortic valve (BAV) is a common congenital valvular malformation, which may lead to early aortic valve disease and bicuspid-associated aortopathy. A novel BAV classification system was recently proposed to coincide with transcatheter aortic valve replacement being increasingly considered in younger patients with symptomatic BAV, with good clinical results, yet without randomized trial evidence. Procedural technique, along with clinical outcomes, have considerably improved in BAV patients compared with tricuspid aortic stenosis patients undergoing transcatheter aortic valve replacement. The present review summarizes the novel BAV classification systems and examines contemporary surgical and transcatheter approaches.

17.
Can J Cardiol ; 40(2): 218-234, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37758014

RESUMO

The growing number of candidates for transcatheter aortic valve replacement (TAVR) has increased the interest in the concomitant presence of coronary artery disease (CAD) and severe aortic stenosis (AS), prompting the need to define the appropriate revascularization strategy for each case. The reported prevalence of concurrent AS and CAD has varied over the years on the basis of the CAD definition and the population evaluated. Revascularization for treating CAD in patients with severe AS involves additional interventions that could impact outcomes. The addition of coronary artery bypass grafting (CABG) to surgical aortic valve replacement (SAVR) has demonstrated favourable effects on long-term prognosis, while the impact of adding percutaneous coronary intervention (PCI) to TAVR may depend on the CAD complexity and the feasibility of achieving complete or reasonably incomplete revascularization. Furthermore, the comparison between SAVR+CABG and TAVR+PCI in low-intermediate surgical risk and low-intermediate complex CAD patients did not reveal differences in all-cause mortality or stroke between the groups. However, there is some evidence showing a lower incidence of major cardiovascular events with the SAVR+CABG strategy for patients with complex CAD. Thus, SAVR+CABG seems to be the best option for patients with low-intermediate surgical risk and complex CAD, and TAVR+PCI for high surgical risk patients seeking complete and/or reasonable incomplete revascularization. After deciding between TAVR+PCI or SAVR+CABG, factors such as timing for PCI, low ejection fraction, coronary reaccess, and valve durability must be considered. Finally, alternative methods for assessing CAD severity are currently under evaluation to ascertain their real value for guiding revascularization in patients with severe AS with CAD.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Implante de Prótese de Valva Cardíaca , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco
18.
Clin Infect Dis ; 78(1): 179-187, 2024 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-37552784

RESUMO

BACKGROUND: Scarce data are available comparing infective endocarditis (IE) following surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). This study aimed to compare the clinical presentation, microbiological profile, management, and outcomes of IE after SAVR versus TAVR. METHODS: Data were collected from the "Infectious Endocarditis after TAVR International" (enrollment from 2005 to 2020) and the "International Collaboration on Endocarditis" (enrollment from 2000 to 2012) registries. Only patients with an IE affecting the aortic valve prosthesis were included. A 1:1 paired matching approach was used to compare patients with TAVR and SAVR. RESULTS: A total of 1688 patients were included. Of them, 602 (35.7%) had a surgical bioprosthesis (SB), 666 (39.5%) a mechanical prosthesis, 70 (4.2%) a homograft, and 350 (20.7%) a transcatheter heart valve. In the SAVR versus TAVR matched population, the rate of new moderate or severe aortic regurgitation was higher in the SB group (43.4% vs 13.5%; P < .001), and fewer vegetations were diagnosed in the SB group (62.5% vs 82%; P < .001). Patients with an SB had a higher rate of perivalvular extension (47.9% vs 27%; P < .001) and Staphylococcus aureus was less common in this group (13.4% vs 22%; P = .033). Despite a higher rate of surgery in patients with SB (44.4% vs 27.3%; P < .001), 1-year mortality was similar (SB: 46.5%; TAVR: 44.8%; log-rank P = .697). CONCLUSIONS: Clinical presentation, type of causative microorganism, and treatment differed between patients with an IE located on SB compared with TAVR. Despite these differences, both groups exhibited high and similar mortality at 1-year follow-up.


Assuntos
Estenose da Valva Aórtica , Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Fatores de Risco
19.
Circulation ; 149(9): 644-655, 2024 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-37883682

RESUMO

BACKGROUND: The optimal treatment in patients with severe aortic stenosis and small aortic annulus (SAA) remains to be determined. This study aimed to compare the hemodynamic and clinical outcomes between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with a SAA. METHODS: This prospective multicenter international randomized trial was performed in 15 university hospitals. Participants were 151 patients with severe aortic stenosis and SAA (mean diameter <23 mm) randomized (1:1) to TAVR (n=77) versus SAVR (n=74). The primary outcome was impaired valve hemodynamics (ie, severe prosthesis patient mismatch or moderate-severe aortic regurgitation) at 60 days as evaluated by Doppler echocardiography and analyzed in a central echocardiography core laboratory. Clinical events were secondary outcomes. RESULTS: The mean age of the participants was 75.5±5.1 years, with 140 (93%) women, a median Society of Thoracic Surgeons predicted risk of mortality of 2.50% (interquartile range, 1.67%-3.28%), and a median annulus diameter of 21.1 mm (interquartile range, 20.4-22.0 mm). There were no differences between groups in the rate of severe prosthesis patient mismatch (TAVR, 4 [5.6%]; SAVR, 7 [10.3%]; P=0.30) and moderate-severe aortic regurgitation (none in both groups). No differences were found between groups in mortality rate (TAVR, 1 [1.3%]; SAVR, 1 [1.4%]; P=1.00) and stroke (TAVR, 0; SAVR, 2 [2.7%]; P=0.24) at 30 days. After a median follow-up of 2 (interquartile range, 1-4) years, there were no differences between groups in mortality rate (TAVR, 7 [9.1%]; SAVR, 6 [8.1%]; P=0.89), stroke (TAVR, 3 [3.9%]; SAVR, 3 [4.1%]; P=0.95), and cardiac hospitalization (TAVR, 15 [19.5%]; SAVR, 15 [20.3%]; P=0.80). CONCLUSIONS: In patients with severe aortic stenosis and SAA (women in the majority), there was no evidence of superiority of contemporary TAVR versus SAVR in valve hemodynamic results. After a median follow-up of 2 years, there were no differences in clinical outcomes between groups. These findings suggest that the 2 therapies represent a valid alternative for treating patients with severe aortic stenosis and SAA, and treatment selection should likely be individualized according to baseline characteristics, additional anatomical risk factors, and patient preference. However, the results of this study should be interpreted with caution because of the limited sample size leading to an underpowered study, and need to be confirmed in future larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03383445.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Estudos Prospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Acidente Vascular Cerebral/etiologia
20.
Cardiovasc Revasc Med ; 60: 18-26, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37793964

RESUMO

AIM: To determine long-term survival of patients after cardiac arrest undergoing emergent coronary angiography and therapeutic hypothermia. METHODS: We analysed data from patients treated within the regional STEMI Network from January 2015 to December 2020. The primary endpoint was all-cause mortality at median follow-up. Secondary endpoints were periprocedural complications (arrhythmias, pulmonary edema, cardiogenic shock, mechanical complication, stent thrombosis, reinfarction, bleeding) and 6-month all-cause death. A landmark analysis was performed, studying two time periods; 0-6 months and beyond 6 months. RESULTS: From a total of 24,125 patients in the regional STEMI network, 494 patients who suffered from cardiac arrest were included and divided into two groups: treated with (n = 119) and without therapeutic hypothermia (n = 375). At median follow-up (16.0 [0.2-33.3] months), there was no difference in the adjusted mortality rate between groups (51.3 % with hypothermia vs 48.0 % without hypothermia; HRadj1.08 95%CI [0.77-1.53]; p = 0.659). There was a higher frequency of bleeding in the hypothermia group (6.7 % vs 1.1 %; ORadj 7.99 95%CI [2.05-31.2]; p = 0.002), without difference for the rest of periprocedural complications. At 6-month follow-up, adjusted all-cause mortality rate was similar between groups (46.2 % with hypothermia vs 44.5 % without hypothermia; HRadj1.02 95%CI [0.71-1.47]; p = 0.900). Also, no differences were observed in the adjusted mortality rate between 6 months and median follow-up (9.4 % with hypothermia vs 6.3 % without hypothermia; HRadj2.02 95%CI [0.69-5.92]; p = 0.200). CONCLUSIONS: In a large cohort of patients with cardiac arrest within a regional STEMI network, those treated with therapeutic hypothermia did not improve long-term survival compared to those without hypothermia.


Assuntos
Parada Cardíaca , Hipotermia , Parada Cardíaca Extra-Hospitalar , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Angiografia Coronária , Resultado do Tratamento , Parada Cardíaca/diagnóstico , Parada Cardíaca/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...