Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Dent ; 2023: 8851098, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37885810

RESUMO

Background: Stress distribution plays a vital role in the longevity and success of implant-supported prosthesis. This study evaluated the von Mises stress and microstrain in the peri-implant bone and the implant-abutment junction of short dental implants with three different implant-abutment connections in splinted and unsplinted conditions using finite element analysis (FEA). Materials and Methods: In this experimental study, nine transversely isotropic finite element models were developed, and randomly divided into three equal groups (n = 3): control, (Group AC) single-standard 4.3 × 10 mm bone level implant-supported restorations with external hexagonal (EH) connection, internal conical (IC) and internal trichannel (ITC) connection, single short implant-supported restorations (Group AT), and splinted short implant-supported restorations (Group B) for each of the three implant-abutment connections, respectively. A 200 N load was applied along the long axis of the implants and a 100 N (45°) oblique load was applied and von Mises stress and microstrain values were evaluated. Results: Single standard implants demonstrated the highest von Mises stress and microstrain values followed by single short implants and splinted short implants, respectively. Among the implant-abutment connections, the IC connection showed the highest values and the ITC connection showed the least values. Conclusion: Within the limitations of this study, it was concluded that splinting of short dental implants demonstrated lesser and more homogeneous stress and microstrain, especially on oblique loading. The microstrain values for all connections evaluated were within the physiological loading limit (200-2,500 N) and were hence considered safe for clinical use.

2.
Int J Dent ; 2022: 2557127, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35677808

RESUMO

Background: To evaluate and compare the shear bond strength of feldspathic porcelain to four distinctively surface-treated Ni-Cr and Co-Cr alloys and to assess the impact of oxidation-heat treatment on porcelain to base metal alloy bond strength. Methods: 40 specimens each of nickel-chromium alloy and cobalt-chromium alloy were cast. A total of four groups of specimens were created. Group I was surface-treated by sandblasting with 50 µm alumina particles, Group II was surface-treated by sandblasting with 110 µm alumina particles, Group III and Group IV were surface-treated with 250 µm alumina particles. In Group IV, after sandblasting initially with 250 µm alumina particles, the alloys were subjected to oxidation and resandblasting with 250 µm alumina particles. Each of the specimen was coated with opaque and body porcelain and fired to a total thickness of 2 mm porcelain. A universal measuring machine was used to assess shear bond strength at a crosshead speed of 0.5 mm/min. Results: Two-way ANOVA followed by Tukey's post hoc test was used to assess the significant difference within the groups. Unpaired t-test was used for the intergroup comparison of the obtained data. The study showed that the size of the air abrasion particles used for sandblasting significantly influenced the porcelain to metal surface bond strength, with p value <0.001. The bond strength values of the two alloys tested showed no major variations. Result also showed that oxidation influences the metal-ceramic bond strength. Conclusions: The bond strength of the metal-ceramic interface is influenced by the alloy's surface treatment. The oxidation process impacts the bond strength of the metal-ceramic system.

3.
Int J Dent ; 2022: 1546802, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35464102

RESUMO

Purpose: To study the effect of different surface treatments on the micro-shear bond strength and surface characteristics of zirconia. Methods: Two types of zirconia ceramics were tested: opaque (O) and translucent (T). Each type of zirconia was further allotted into four groups based on the type of surface treatment method. The four groups were: control (C), air abrasion with 110 µm Al2O3 particles (A), etching with Zircos-E Etching solution for 2 hours (E), and a combination of air abrasion and etching (AE). After the surface treatment, all specimens were ultrasonically cleaned and 10 resin cement cylinders were attached to the zirconia discs in each group. A micro-shear bond strength test was performed in a universal testing machine at a crosshead speed of 0.5 mm/min. The fracture surfaces were assessed under a compound microscope. SEM, EDAX, and AFM analyses were done for the zirconia specimens after being subjected to surface treatment. Statistical analysis for the bond strength test was done using the Shapiro-Wilk test, one-way analysis of variance (ANOVA), and Post hoc Tukey test. Results: The micro-shear bond strength values for the groups were as follows in megapascals (MPa): OC 18.96 (5.54), OA 22.66 (2.51), OE 28.48 (4.50), OAE 28.63 (4.53), TC 22.82 (5.46), TA 25.36 (5.17), TE 28.12 (4.76), and TAE 32.00 (3.47). The one-way analysis of variance (ANOVA) and post hoc Tukey HSD tests were done which showed significant results in the groups. In opaque zirconia, significant differences were seen in the etching and air abrasion with etching groups when compared with the control and air abrasion groups. There was no difference between the etching and air abrasion with etching groups. For translucent zirconia, the only significant difference was seen in the air abrasion with etching group in comparison with the control and air abrasion groups. The mode of failure was majorly adhesive. The surface topography and surface roughness showed significant differences between the groups. The EDAX results showed material loss that occurred due to sandblasting in the air abrasion groups. Conclusions: Etching with Zircos-E Etching solution significantly increased the bond strength of zirconia to resin cement when compared with other surface treatment methods. In translucent zirconia, the best results can be achieved by combining etching with air abrasion.

4.
Int J Dent ; 2022: 4916464, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35096067

RESUMO

PURPOSE: To investigate and compare the cellular host response of human gingival fibroblasts (HGF) on four currently used cements. Methods and Material. 5 cement pellet samples were made for each of the 4 test cements (n = 20). The cements used for this study were zinc phosphate, zinc oxide noneugenol (ZOE), RelyX U200, and glass ionomer cement (GIC). One commercially available cell line was used to investigate the cytotoxicity of peri-implant tissues. Direct contact cell culture testing was conducted following International Organization for Standardization (ISO) methods 10993-5 and 10993-12 (MTT assay test). Cell cultures without dental cement were considered as control. Cells were allowed to grow and confluence over 48 hours after subcultivation according to standard laboratory procedures. The cells were kept in direct contact with the cement samples for 24 hours before being subjected to analysis. All specimens were tested in triplicate to validate the results. Quantitative evaluation of cytotoxicity was done to measure cell death and inhibition of cell growth. Results were analyzed using 1-way ANOVA (a = 0.05) followed by Tukey B post hoc test. RESULTS: The results of the study showed that HGF was vulnerable to the dental cement test material. GIC, zinc phosphate, ZOE, and resin cement were cytotoxic in decreasing order, respectively, and significantly reduced the cell viability after exposure to HGF (p < 0.001). CONCLUSIONS: Within the limitations of this in vitro cellular study, results indicated that the test dental cements were cytotoxic to HGF. The highest cytotoxicity was observed in GIC followed by zinc phosphate, ZOE, and resin cement.

6.
Indian J Dent Res ; 31(2): 282-290, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32436910

RESUMO

OBJECTIVE: This study evaluated the effect of chemical disinfection and microwave irradiation on the surface hardness and roughness of two commercially available hard relining materials (Ufi Gel hard, GC Kooliner) and one denture base resin (Trevalon). MATERIALS AND METHODS: A total of 72 specimens (n = 24) were divided into four groups. C: Not disinfected, Cl: disinfected with 4% chlorhexidine solution, Gl: disinfected with 2% glutaraldehyde solution, Mw: disinfected with microwave irradiation (650 W; 6 min). Hardness and roughness measurements were made after polymerisation, 1st day, 14th day and 28th day. RESULTS: Ufi Gel hard showed an increased roughness after 1st day (P = 0.021) following chemical disinfection and GC Kooliner showed similar results after 14th day (P < 0.05). Microwave irradiation showed a significant increase in surface roughness value after 1st day (P < 0.05) for both Ufi Gel hard and GC Kooliner. Hardness of both Ufi Gel (12.131 to 7.333 VHN) and Kooliner (9.133 to 5.276 VHN) was significantly reduced by chemical disinfection, while microwave irradiation resulted in an increased surface hardness of Kooliner (from 9.126 to 12.713 VHN) and Ufi Gel hard (from 11.698 to 14.940VHN). Results for Trevalon were not significant for both the disinfection methods. CONCLUSIONS: Microwave irradiation increased the surface roughness and hardness of Ufi Gel hard and Kooliner, while chemical disinfection resulted in a decreased hardness and increased roughness of both hard relining materials. There was no effect of either of the disinfection methods on Trevalon.


Assuntos
Bases de Dentadura , Reembasadores de Dentadura , Desinfecção , Dureza , Teste de Materiais , Micro-Ondas , Propriedades de Superfície
7.
J Indian Prosthodont Soc ; 20(4): 363-370, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33487963

RESUMO

AIM: This study assessed the effect of postetch cleansing on the surface microstructure, surface topography, and microshear bond strength (µSBS) of lithium disilicate and the resin cement. SETTING AND DESIGN: In Vitro analytical study. MATERIALS AND METHODS: Fifteen discs (10 mm diameter and 2 mm thickness) were fabricated from highly translucent lithium disilicate IPS Emax 2 ceramic (Ivoclar Vivadent, Schaan, Liechtenstein). Four resin cement (RelyX Ultimate, 3M ESPE) cylinders (0.9 mm diameter and 4 mm high) were placed on each ceramic disc (total n = 60). The samples were divided into three groups based on the surface treatment of the ceramic discs (20 resin cement cylinders on 5 discs in each group). Group I (HF) (control) etched with 9.6% HF with no postetch cleansing, Group II (HFP) etched with 9.6% HF for 20 s followed by rinsing with water and postetching cleansing with 37% phosphoric acid, and Group III (HFPU) etched with 9.6% HF followed by active application of 37% phosphoric acid followed by postetch cleansing in ultrasonic bath for 5 min. µSBS of resin cement to ceramic surfaces was tested following a standard protocol. Surface roughness was evaluated using an atomic force microscope. Surface topography and elemental analysis were analyzed using SEM/EDX. Mode of failure was also assessed. STATISTICAL ANALYSIS USED: The data were analysed using one way analysis of variance and post hoc tukeys test. RESULTS: The µSBS were found to be highest for Group III (HFPU), followed by Group II (HFP) followed by Group I (HF) and were statistically significant. There was a difference in the surface topography and surface microstructure between the three groups. Mode of failure was predominantly adhesive. CONCLUSION: The µSBS, surface topography, and surface microstructure were found to be superior in the groups, in which postetch cleansing was done as compared to the control in which no postetch cleansing was done.

8.
J Indian Prosthodont Soc ; 18(3): 196-200, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30111907

RESUMO

Primary stability in dental implants is an essential factor for achieving successful osseointegration. Surgical procedure and bone quality are among the most common factors that affect primary stability. It is also crucial to achieve high-insertion torque which is important for obtaining primary stability. Maintaining sufficient bone bulk and density is essential to achieve necessary bone-to-implant contact for obtaining a biomechanically stable implant. A new concept for osteotomy called osseodensification (OD) has been at the forefront of changes in surgical site preparation in implantology. This relatively new concept with universally compatible drills has been proposed to help in better osteotomy preparation, bone densification, and indirect sinus lift and also achieve bone expansion at different sites of varying bone densities. This procedure has also shown improvement in achieving better implant primary stability and better osteotomy than conventional implant drills. A systematic review was undertaken to analyze if OD procedure had any advantages over conventional osteotomy on bone density and primary stability. An electronic database search was conducted in PubMed using keywords such as "OD," "implant primary stability," "implant bone density," and "implant osteotomy." A total of 195 articles were collected and subjected to screening using inclusion and exclusion criteria. A literature review was done, following which it was seen that the use of versah drills for bone OD resulted in undersized osteotomy compared to conventional drills. It also resulted in improved bone density and increase in percentage bone volume and bone-to-implant contact, thereby improving implant stability.

9.
Indian J Dent Res ; 27(2): 190-4, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27237212

RESUMO

CONTEXT: Castability has been found to be affected by many aspects of the entire casting system. Very few references in dental literature are available regarding recasting of the base metal alloys. AIMS: To evaluate and compare the castability of fresh and reused nickel-chromium alloy and to evaluate the effect of two brands of investment materials on castability of nickel-chromium alloy. SUBJECTS AND METHODS: For the experimental purpose of evaluation of the effect of recasting of nickel-chromium alloy on its castability, different percentages of new and casted alloy (Nickel-chromium alloy-(Wirolloy NB, Type 4 (Ni-67%; Cr-25%; Mo-5%; Si-1.5%; Mn, Nb, B, C each <1%) and two commercial brands of investment materials namely, Deguvest Impact (Degudent; Dentsply Germany) and Bellavest SH (Degudent; Dentsply Germany) was used to obtain 30 samples. Castability value was obtained using Whitlock's formula. Student t-test and one way ANOVA using SPSS 20.0 software was done. RESULTS: The results of this study confirm earlier works that demonstrate that there is no significant difference in castability values of new and recast alloys. In addition, it also demonstrated, there was no difference in castability using Deguvest Impact and Bellavest SH investment materials. CONCLUSIONS: Within the limitations of the study, it was concluded that there was no significant difference found in castability of different percentage combinations of new and once casted alloy using two investment materials. The addition of new alloy during recasting to maintain the castability of nickel-chromium alloy may therefore not be required.


Assuntos
Ligas de Cromo/química , Ligas Dentárias/química , Revestimento para Fundição Odontológica/química , Técnica de Fundição Odontológica , Técnicas In Vitro , Teste de Materiais , Propriedades de Superfície
10.
Gerodontology ; 33(3): 402-9, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25523749

RESUMO

OBJECTIVE: Candida albicans-associated denture stomatitis is the most common type of denture stomatitis seen in denture wearers. This study evaluates and compares the antifungal action of fluconazole, chlorhexidine gluconate and tea tree oil on heat-polymerised denture base resin, which has been previously contaminated with C. albicans grown in BHI broth. MATERIAL AND METHODS: Seventy-five specimens were immersed in BHI broth previously inoculated with C. albicans and stored for 3 h at 37°C. They were divided into five groups (n = 15): G1: 2% chlorhexidine solution; G2: 100% pure pharmaceutical grade tea tree oil; G3: 65 µg/ml fluconazole solution; C1: specimens not disinfected; C2: specimens not contaminated with Candida. Each specimen was then transferred to individual tubes containing BHI broth and incubated for 24 h. Culture media turbidity was evaluated for absorbance over a period of 14 days using a microplate reader. It was observed that the lower the absorbance, the stronger the antimicrobial action. Statistical analysis was performed (two-way anova and Bonferroni test, p < 0.001). RESULTS: Chlorhexidine and tea tree oil inhibited Candida up to the 14th day, whereas antifungal effect of fluconazole was not significant after the 7th day. CONCLUSION: Tea tree oil and chlorhexidine gluconate are more effective than fluconazole in inhibiting C. albicans growth on heat-polymerised acrylic resin.


Assuntos
Candida albicans/efeitos dos fármacos , Clorexidina/análogos & derivados , Bases de Dentadura/microbiologia , Fluconazol/farmacologia , Óleo de Melaleuca/farmacologia , Resinas Acrílicas , Anti-Infecciosos Locais/farmacologia , Clorexidina/farmacologia
11.
Int J Orthod Milwaukee ; 26(4): 45-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-27029092

RESUMO

Adult orthodontics has been an area of increasing focus in recent times. Comprehensive treatment of adults is more challenging due to a myriad of problems that coexist in an adult that makes treatment planning more challenging. A large number of individuals seek dental care because of aesthetic reasons, that is, the desire to look more attractive by improving their smiles. The role an attractive smile plays on a person's self-image and confidence cannot be overemphasized. Evaluating and treating patients for the purpose of smile design often involves a multi-discipline approach. Achieving an ideal smile may require orthodontics, orthognathic surgery, periodontal therapy, including soft tissue repositioning and bone re-contouring, cosmetic dentistry, and plastic surgery. This aesthetic approach to patient care produces the best dental and dental-facial beauty. This paper describes a case report in which an orthodontist, an endodontist, and a prosthodontist worked as a team to improve the patients smile and confidence.


Assuntos
Estética Dentária , Arcada Parcialmente Edêntula/reabilitação , Má Oclusão Classe I de Angle/terapia , Planejamento de Assistência ao Paciente , Equipe de Assistência ao Paciente , Cefalometria/métodos , Implantes Dentários para Um Único Dente , Prótese Dentária Fixada por Implante , Facetas Dentárias , Prótese Parcial Fixa , Diastema/terapia , Assimetria Facial/terapia , Humanos , Incisivo/anormalidades , Masculino , Autoimagem , Sorriso , Técnicas de Movimentação Dentária/métodos , Adulto Jovem
12.
Contemp Clin Dent ; 2(4): 355-8, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22346167

RESUMO

Malignant melanoma of the oral cavity is very rare. This clinical report describes a method for prosthetic rehabilitation of a patient with malignant melanoma of the palate following partial maxillectomy with a closed hollow interim obturator.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...