1.
Braz J Phys Ther ; 28(2): 101062, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38640642

RESUMO

BACKGROUND: For evidence-based practice, clinicians and researchers can rely on well-conducted randomized clinical trials that exhibit good methodological quality, provide adequate intervention descriptions, and implementation fidelity. OBJECTIVE: To assess the description and implementation fidelity of exercise-based interventions in clinical trials for individuals with rotator cuff tears. METHODS: A systematic search was conducted in PubMed, Embase, CINAHL, LILACS, Cochrane Library, Web of Science, SCOPUS and SciELO. Randomized clinical trials that assessed individuals with rotator cuff tears confirmed by imaging exam were included. All individuals must have received an exercise-based treatment. The methodological quality was scored with the Physiotherapy Evidence Database (PEDro) scale. The Template for Intervention Description and Replication (TIDieR) checklist and the National Institutes of Health Behaviour Change Consortium (NIHBCC) were used to assess intervention description and implementation fidelity, respectively. RESULTS: A total of 13 studies were included. Despite their adequate methodological quality, the description of the intervention was poor with TIDieR scores ranging from 6 to 15 out of 24 total points. The TIDieR highest-scoring item was item 1 (brief name) that was reported in all studies. Considering fidelity, only one of the five domains of NIHBCC (i.e., treatment design) reached just over 50%. CONCLUSION: Exercise-based interventions used in studies for individuals with rotator cuff tears are poorly reported. The description and fidelity of the intervention need to be better reported to assist clinical decision-making and support evidence-based practice.


Assuntos
Terapia por Exercício , Lesões do Manguito Rotador , Humanos , Lesões do Manguito Rotador/terapia , Terapia por Exercício/métodos , Manguito Rotador/fisiopatologia , Ensaios Clínicos como Assunto
2.
Clin Rehabil ; 38(4): 558-568, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38295335

RESUMO

OBJECTIVE: To identify differences in the muscle mechanical properties of the pelvic floor (PF) and lumbar paravertebral (LP) muscles between young nulliparous and uni/multiparous women. Secondarily, specific behaviors, depending on the presence or absence or urinary incontinence (UI), were also researched. DESIGN: Case-control study. SETTING: Higher education institution. PARTICIPANTS: One hundred young women participated, divided into two groups depending on whether they had vaginal birth (nulliparous or uni/multiparous). Each group included women with and without UI. MAIN MEASURES: A muscle mechanical properties (tone, stiffness, decrement-inverse of elasticity-, and viscoelastic properties: relaxation and creep) assessment of the PF and LP muscles were performed with a hand-held tonometer. RESULTS: Tone and stiffness of both sides of the PF presented group by UI interaction (p < 0.05), with uni/multiparous women with UI showing higher tone and stiffness compared to multiparous women without UI. In LP muscles, uni/multiparous women showed greater tone and stiffness on the right and left sides [-2.57 Hz (95% confidence interval -4.42,-0.72) and -79.74 N/m (-143.52,-15.97); -2.20 Hz (-3.82,-0.58) and -81.30 N/m (-140.66-,21.95), respectively], as well as a decrease in viscoelastic properties compared to nulliparous women [relaxation: 2.88 ms (0.31,5.44); creep: 0.15 (0.01,0.30); relaxation: 2.69 ms (0.13,5.25); creep: 0.14 (0,0.28), respectively]. CONCLUSIONS: Vaginal birth and UI have a differential influence on the muscle mechanical properties of the PF and LP muscles. The determination of muscle mechanical properties by externally applied hand-held tonometry improves the knowledge of the lumbopelvic status, with applicability in clinical and research fields.


Assuntos
Incontinência Urinária , Feminino , Humanos , Estudos de Casos e Controles , Incontinência Urinária/etiologia , Força Muscular/fisiologia , Músculos
3.
Sci Rep ; 13(1): 21612, 2023 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-38062151

RESUMO

The lumbopelvic muscle mechanical properties (MMPs) are clinically relevant, but their dependence on sex remains unknown. Therefore, this study aimed to identify if lumbopelvic MMPs depend on the sex in a young adult population. Thirty-five healthy nulliparous women and 35 healthy men were analyzed (age range: 18-50). Lumbopelvic MMPs, that is, tone, stiffness, elasticity, relaxation and creep, assessed with MyotonPRO®, and pelvic floor (PF) health questionnaires were compared between-sexes. Intra-group correlations between sociodemographic and clinical data, and MMPs were also determined. The MMPs of PF were different between healthy non-climacteric adults of both sexes, with women showing higher values of tone and stiffness and lower values of elasticity and viscoelastic properties than men (in all cases, p < 0.03). At lumbar level, tone and stiffness were higher for men at both sides (in all cases, p < 0.04), and relaxation was lower at left side (p = 0.02). The MMPs showed few correlations with sociodemographic data within women. However, within males, there were positive correlations for PF stiffness and viscoelastic parameters with age, BMI and function (0.334 < r < 0.591) and, at lumbar level, negative correlations for tone and stiffness ( - 0.385 < r < -0.590) and positive correlations for viscoelastic properties (0.564 < r < 0.719), with BMI. This indicated that between-sexes differences of lumbopelvic MMPs depend on the specific location of assessment in healthy non-obese young individuals. Women show higher tone and stiffness and lower elasticity and viscoelasticity than men, at PF level.


Assuntos
Fenômenos Fisiológicos Musculoesqueléticos , Masculino , Adulto Jovem , Humanos , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Estudos Transversais , Região Lombossacral , Tono Muscular/fisiologia , Músculos
4.
J Appl Oral Sci ; 31: e20230045, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37909525

RESUMO

OBJECTIVE: Recently, the DC/TMD has become an essential tool for the diagnosis of temporomandibular disorders (TMD). However, as they fail to include functional activities, new assessment proposals have emerged, such as the isometric contraction test (IC test) of the masticatory muscles, which uses muscle contractions to identify muscular TMD. This study aimed to determine the test-retest reliability of the IC test. METHODS: A total of 64 participants (40 women and 24 men) completed the IC test administered by two different physical therapists on two non-consecutive days. Cohen's kappa (k), PABAK, and percent agreement (PA) between days were estimated. RESULTS: The IC test showed good to excellent test-retest reliability values (k>0.77; PABAK>0.90), both globally and individually for the muscles evaluated, and PA>90%, therefore above the thresholds for clinical applicability. However, the global assessment of myofascial pain and the evaluation of the medial pterygoid muscle showed slightly lower reliability values. CONCLUSION: The IC test is reliable for the assessment of subjects with muscular TMD, both in terms of the global assessment and the evaluation of each muscle, which supports its clinical applicability. Care should be taken when assessing myofascial pain globally and when evaluating the medial pterygoid in all types of pain.


Assuntos
Síndromes da Dor Miofascial , Transtornos da Articulação Temporomandibular , Masculino , Humanos , Feminino , Contração Isométrica/fisiologia , Reprodutibilidade dos Testes , Músculos da Mastigação , Transtornos da Articulação Temporomandibular/diagnóstico , Dor
5.
Int Urogynecol J ; 34(10): 2507-2511, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37222738

RESUMO

INTRODUCTION AND HYPOTHESIS: Changes in the mechanisms that modulate sexual response can contribute to the development of female sexual dysfunction (FSD). Although the prevalence of FSD in Brazil has been established, its associated risk factors have not been thoroughly examined. This study aimed to determine the prevalence of FSD in Brazilian women and identify any factors that may be associated with its presence. METHODS: This study used a cross-sectional design and included women aged 18 years or older who had engaged in sexual activity within the past four weeks. Participants completed the Female Sexual Function Index (FSFI) and a sociodemographic and health questionnaire. Two groups were created based on FSFI scores: those with risk for FSD (score >26.55) and those without. The study used t-tests for independent samples to compare quantitative variables between the groups, and the chi-squared test, to compare categorical variables. Binomial logistic regression was used to test the association between sociodemographic and health variables and FSD. RESULTS: FSD had a prevalence of 31.7% (95% CI: 28.2%-35.5%). The results indicated that practice of physical activity was inversely associated with FSD (OR: 0.64, 95% CI: 0.45-0.92), whereas urinary incontinence (OR: 2.55, 95% CI: 1.68-3.87) and post-menopause (OR: 4.69, 95% CI: 1.66-13.3) were directly associated with FSD. CONCLUSIONS: A high prevalence of FSD was observed among Brazilian women in this study. Physically active women are less likely to have FSD. Menopause and the presence of urinary incontinence can negatively impact female sexual function.

6.
J. appl. oral sci ; 31: e20230045, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1521082

RESUMO

Abstract Recently, the DC/TMD has become an essential tool for the diagnosis of temporomandibular disorders (TMD). However, as they fail to include functional activities, new assessment proposals have emerged, such as the isometric contraction test (IC test) of the masticatory muscles, which uses muscle contractions to identify muscular TMD. Objective This study aimed to determine the test-retest reliability of the IC test. Methods A total of 64 participants (40 women and 24 men) completed the IC test administered by two different physical therapists on two non-consecutive days. Cohen's kappa (k), PABAK, and percent agreement (PA) between days were estimated. Results The IC test showed good to excellent test-retest reliability values (k>0.77; PABAK>0.90), both globally and individually for the muscles evaluated, and PA>90%, therefore above the thresholds for clinical applicability. However, the global assessment of myofascial pain and the evaluation of the medial pterygoid muscle showed slightly lower reliability values. Conclusion The IC test is reliable for the assessment of subjects with muscular TMD, both in terms of the global assessment and the evaluation of each muscle, which supports its clinical applicability. Care should be taken when assessing myofascial pain globally and when evaluating the medial pterygoid in all types of pain.

7.
Diagnostics (Basel) ; 12(8)2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-36010212

RESUMO

In recent years, the Diagnostic Criteria for Temporomandibular Pain Disorders (DC/TMD) has been questioned, mainly because of the dependence on the muscular pressure needed to be applied during the clinical examination. Therefore, it is necessary to establish improvements in diagnostic strategies for DC/TMD of axis I. The aim of this study was to determine the validity of the Isometric Contraction Test of the masticatory muscles (ICTest) to diagnose DC/TMD of axis I. Forty (n = 40) patients with muscular TMD (myalgia in any of its subtypes), as well as forty age and sex matched controls, participated. They were diagnosed according to DC/TMD of axis I and performed the ICTest in a single session. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV), and positive (LR+) and negative likelihood ratios (LR-) of the ICTest compared with the DC/TMD of axis I were calculated. The ICTest showed a specificity of 95% for the diagnosis of myalgia, and between 94.9% and 96.8% for all subtypes in relation to the DC/TMD of axis I. For sensitivity, lower values were obtained, that is, 90.0% for myalgia, and losing sensitivity depending on the type of myalgia. The LR+ was over 10 for all diagnoses, with the exception of myofascial pain with referral, which was lower. When addressing the LR-, the myofascial diagnosis was the only one below 0.2. According to the results, the ICTest could be considered a valid procedure to diagnose subjects with muscular TMD in a clinical setting.

8.
Artigo em Inglês | MEDLINE | ID: mdl-35886624

RESUMO

Spinal cord injury (SCI) has been associated with high mortality rates. Thanks to the multidisciplinary vision and approach of SCI, including the application of new technologies in the field of neurorehabilitation, people with SCI can survive and prosper after injury. The main aim of this systematic review was to analyze the effectiveness of the combined use of VR and robotics in the treatment of patients with SCI. The literature search was performed between May and July 2021 in the Cochrane Central Register of Controlled Trials, Physiotherapy Evidence Database (PEDro), PubMed, and Web of Science. The methodological quality of each study was assessed using the SCIRE system and the PEDro scale, whereas the risk of bias was analyzed using the Cochrane Collaboration's tool. A total of six studies, involving 63 participants, were included in this systematic review. Relevant changes were found in the upper limbs, with improvements of shoulder and upper arm mobility, as well as the strengthening of weaker muscles. Combined rehabilitation may be a valuable approach to improve motor function in SCI patients. Nonetheless, further research is necessary, with a larger patient sample and a longer duration.


Assuntos
Reabilitação Neurológica , Robótica , Traumatismos da Medula Espinal , Realidade Virtual , Humanos , Traumatismos da Medula Espinal/complicações , Extremidade Superior
9.
Diagnostics (Basel) ; 12(2)2022 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-35204392

RESUMO

This research aimed to identify changes in muscle mechanical properties (MMPs) when a standardized sequence of movements is performed and to determine the influence of acute low back pain (LBP) and age on the MMPs. Socio-demographic, clinical variables and MMPs were collected in 33 patients with LBP and 33 healthy controls. A 2 × 2 × 2 (group × age × time) analysis of variance (ANOVA) mixed model was used to determine the effect of the study factors on the different MMPs. There were no significant triple interactions. After the movements, tone and stiffness increased 0.37 Hz and 22.75 N/m, respectively, in subjects <35 years, independent of their clinical status. Relaxation showed differences by age in healthy subjects and creep in LBP subjects. Furthermore, elasticity was higher in <35 years (p < 0.001) without the influence of any other factor. In conclusion, sequenced movements can modify tone and stiffness as a function of age, while age-associated changes in viscoelastic characteristics depends on pain but not on movements. The MMPs should be assessed, not only at the beginning of the physical examination at rest, but also along the patient's follow-up, depending on their pain and age, in a clinical setting.

10.
Diagnostics (Basel) ; 11(12)2021 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-34943552

RESUMO

An analysis of the muscle mechanical properties (MMPs) of the pelvic floor muscles (PFMs) is relevant for understanding the physiopathology of urinary incontinence (UI). However, there is no objective and reliable methodology currently available for quantifying the MMPs of PFMs. Thus, the objective was to determine the intra-rater and inter-rater reliability of the MMPs of PFM assessment with a hand-held tonometer device, called the MyotonPRO, in young women with and without UI. Sociodemographic and pelvic floor questionnaires, plus MMPs of PFMs were assessed in 38 nulliparous women with UI and 40 matched healthy women by two trained physiotherapists on two different occasions, 48-72 h apart. Good to excellent absolute reliability was found for tone, stiffness, and decrement of both intra- and inter-rater analyses in both study groups (Intraclass Correlation Coefficient ranged from 0.75 to 0.92), with a trend of lower values for relaxation and creep. The standard error of measurement (SEM) did not achieve 10% of the mean values for any MMPs. The minimum detectable change (MDC) values were also provided for clinical applications. In conclusion, the relative reliability of tone, stiffness, and the assessment of the decrement of PFMs with MyotonPRO is good to excellent for UI and healthy women. The SEM and MDC values were acceptable for their application in clinical settings.

11.
Diagnostics (Basel) ; 11(10)2021 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-34679595

RESUMO

Different musculoskeletal disorders are a source of pain in the spinal region; most of them can be divided into mechanical, such as low back pain (LBP), or inflammatory origins, as is the case of axial spondyloarthritis (axSpA). Nevertheless, insufficient information is available about the muscle negative consequences of these conditions. Thus, the objective of this study was to identify whether mechanical muscle properties (MMPs) of cervical and lumbar muscles are different between patients with axSpA, subacute LBP (sLBP), and healthy controls. Furthermore, we aimed identify whether MMPs were related to sociodemographic and clinical variables in various study groups. The MMPs, sociodemographic, and clinical variables were obtained in 43 patients with axSpA, 43 subjects with sLBP, and 43 healthy controls. One-way ANOVAs and ROC curves were applied to identify whether the MMPs could differentiate between the study groups. Intra-group Pearson r coefficients to test the associations between MMPs and the rest of the variables were calculated. The results showed that axSpA subjects have a higher tone and stiffness and a lower relaxation and creep than sLBP and healthy ones (p < 0.05). All lumbar and cervical MMPs, except for decrement, could correctly classify axSpA and healthy subjects and axSpA and sLBP patients (in both cases, Area Under the Curve > 0.8). However, no MMP could differentiate between sLBP and healthy subjects. Each group had a different pattern of bivariate correlations between MMPs and sociodemographic and clinical data, with a worse state and progression of the axSpA group associated with a higher tone and stiffness in both spinal regions. This study supports that MMPs are different and show different patterns of correlations depending on the type of spinal pain.

12.
Diagnostics (Basel) ; 11(2)2021 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-33672470

RESUMO

Our aims were to identify potential differences in muscle mechanical properties (MMPs) of cervical and lumbar tissues and in spinal range of motion (ROM) between patients with acute low back pain (LBP) or acute neck pain (NP) and healthy controls, and to identify if ROMs and MMPs are able to identify subjects among the three groups. Clinical variables (pain, disability, fear of movement, kinesiophobia, quality of life), MMPs and ROMs were obtained in 33 subjects with acute LBP, 33 with acute NP, and 33 healthy control subjects. Between-groups differences and explanatory models to discriminate groups depending on MMPs and ROMs were calculated. The results showed that cervical tone was higher in patients with acute NP than in controls, while cervical decrement was higher in both spinal pain groups. Patients with acute NP showed reduced cervical flexion when compared to acute LBP and control groups, and also cervical rotation, but just against controls. Furthermore, lumbar flexion was reduced in patients with acute LBP when compared to those with acute NP. Cervical decrement was able to discriminate spinal pain individuals from controls in a multinominal regression (R2: Cox-Snell estimation = 0.533; Nagelkerke estimation = 0.600). Lumbar flexion differentiated patients with acute LBP and controls, whereas cervical flexion differentiated patients with acute NP and controls. This study supports a tendency of the affectation of other spinal regions when only one is affected.

13.
Diagnostics (Basel) ; 10(9)2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32882885

RESUMO

OBJECTIVE: The aim of this study was to design and propose a new test based on inertial measurement unit (IMU) technology, for measuring cervical posture and motor control in children with cerebral palsy (CP) and to evaluate its validity and reliability. METHODS: Twenty-four individuals with CP (4-14 years) and 24 gender- and age-matched controls were evaluated with a new test based on IMU technology to identify and measure any movement in the three spatial planes while the individual is seated watching a two-minute video. An ellipse was obtained encompassing 95% of the flexion/extension and rotation movements in the sagittal and transversal planes. The protocol was repeated on two occasions separated by 3 to 5 days. Construct and concurrent validity were assessed by determining the discriminant capacity of the new test and by identifying associations between functional measures and the new test outcomes. Relative reliability was determined using the intraclass correlation coefficient (ICC) for test-retest data. Absolute reliability was obtained by the standard error of measurement (SEM) and the Minimum Detectable Change at a 90% confidence level (MDC90). RESULTS: The discriminant capacity of the area and both dimensions of the new test was high (Area Under the Curve ≈ 0.8), and consistent multiple regression models were identified to explain functional measures with new test results and sociodemographic data. A consistent trend of ICCs higher than 0.8 was identified for CP individuals. Finally, the SEM can be considered low in both groups, although the high variability among individuals determined some high MDC90 values, mainly in the CP group. CONCLUSIONS: The new test, based on IMU data, is valid and reliable for evaluating posture and motor control in children with CP.

14.
Diagnostics (Basel) ; 10(2)2020 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-32024117

RESUMO

OBJECTIVE: This study aimed to determine the validity and reliability of Inertial Measurement Units (IMUs) for the assessment of craniocervical range of motion (ROM) in patients with cerebral palsy (CP). METHODS: twenty-three subjects with CP and 23 controls, aged between 4 and 14 years, were evaluated on two occasions, separated by 3 to 5 days. An IMU and a Cervical Range of Motion device (CROM) were used to assess craniocervical ROM in the three spatial planes. Validity was assessed by comparing IMU and CROM data using the Pearson correlation coefficient, the paired t-test and Bland-Altman plots. Intra-day and inter-day relative reliability were determined using the Intraclass Correlation Coefficient (ICC). The Standard Error of Measurement (SEM) and the Minimum Detectable Change at a 90% confidence level (MDC90) were obtained for absolute reliability. RESULTS: High correlations were detected between methods in both groups on the sagittal and frontal planes (r > 0.9), although this was reduced in the case of the transverse plane. Bland-Altman plots indicated bias below 5º, although for the range of cervical rotation in the CP group, this was 8.2º. The distance between the limits of agreement was over 23.5º in both groups, except for the range of flexion-extension in the control group. ICCs were higher than 0.8 for both comparisons and groups, except for inter-day comparisons of rotational range in the CP group. Absolute reliability showed high variability, with most SEM below 8.5º, although with worse inter-day results, mainly in CP subjects, with the MDC90 of rotational range achieving more than 20º. CONCLUSIONS: IMU application is highly correlated with CROM for the assessment of craniocervical movement in CP and healthy subjects; however, both methods are not interchangeable. The IMU error of measurement can be considered clinically acceptable; however, caution should be taken when this is used as a reference measure for interventions.

15.
Nurs Outlook ; 66(3): 293-310, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29573827

RESUMO

PURPOSE: The purpose of the study was to summarize the experiences of African psychiatric nurses in their workplace by examining the findings of existing qualitative studies. METHODS: Eleven studies published in English, Portuguese, and Spanish, between 1998 and 2016, which explored psychiatric nurses' experiences in Africa, were included. FINDINGS: After meta-aggregation, five key findings were identified: 1) organization and management, 2) perceptions of professional safety and insecurity, 3) relationship with the patient, 4) emotional experiences and 5) recommendations for improvement. DISCUSSION: The findings in this study highlight the stressful nature of the work climate of the psychiatric nurse in South Africa. More focus on improving working conditions and providing support is necessary to increase the quality of care for psychiatric mental health patients and their nurse providers.


Assuntos
Enfermeiras e Enfermeiros/psicologia , Enfermagem Psiquiátrica , Pesquisa Qualitativa , Atitude do Pessoal de Saúde , Humanos , Relações Enfermeiro-Paciente , Enfermeiras e Enfermeiros/tendências , África do Sul , Local de Trabalho/psicologia , Local de Trabalho/normas
16.
PLoS One ; 11(7): e0159554, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27434594

RESUMO

BACKGROUND: Low back pain (LBP) could be influenced by socio-cultural factors. Pain narratives are important to understand the influence of environment on patients with chronic LBP. There are few studies that have explored the experience of patients with chronic LBP in different socio-cultural environments. The aim of this study was to describe the experience of patients with chronic LBP in Spain and Brazil. METHODS: A qualitative phenomenology approach was implemented. Chronic LBP patients from the University Hospital of Salamanca (Spain), and/or Federal University of São Carlos (Brazil) were included, using purposeful sampling. Data were collected from 22 Spanish and 26 Brazilian patients during in-depth interviews and using researchers' field notes and patients' personal diaries and letters. A thematic analysis was performed and the guidelines for reporting qualitative research were applied. RESULTS: Forty-eight patients with a mean age of 50.7 years (SD: ± 13.1 years) were included in the study. The themes identified included: a) ways of perceiving and expressing pain-the participants focused constantly on their pain and anything outside it was considered secondary; b) the socio-familial environment as a modulator of pain-most participants stated that no one was able to understand the pain they were experiencing; c) religion as a modulator of pain-all Brazilian patients stated that religious belief affected the experience of pain; and d) socio-economic and educational status as a modulator of pain-the study reported that economic factors influenced the experience of pain. CONCLUSIONS: The influences of LBP can be determined based on the how a patient defines pain. Religion can be considered as a possible mechanism for patients to manage pain and as a form of solace.


Assuntos
Hospitais Universitários , Dor Lombar/psicologia , Percepção da Dor , Percepção Social , Adulto , Brasil , Dor Crônica , Feminino , Humanos , Dor Lombar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Pesquisa Qualitativa , Religião , Fatores Socioeconômicos , Espanha