1.
Micromachines (Basel) ; 14(5)2023 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-37241599

RESUMO

In this study, a subminiature implantable capacitive pressure sensor is proposed for biomedical applications. The proposed pressure sensor comprises an array of elastic silicon nitride (SiN) diaphragms formed by the application of a polysilicon (p-Si) sacrificial layer. In addition, using the p-Si layer, a resistive temperature sensor is also integrated into one device without additional fabrication steps or extra cost, thus enabling the device to measure pressure and temperature simultaneously. The sensor with a size of 0.5 × 1.2 mm was fabricated using microelectromechanical systems (MEMS) technology and was packaged in needle-shaped metal housing that is both insertable and biocompatible. The packaged pressure sensor immersed in a physiological saline solution exhibited excellent performance without leakage. The sensor achieved a sensitivity of approximately 1.73 pF/bar and a hysteresis of about 1.7%, respectively. Furthermore, it was confirmed that the pressure sensor operated normally for 48 h without experiencing insulation breakdown or degradation of the capacitance. The integrated resistive temperature sensor also worked properly. The response of the temperature sensor varied linearly with temperature variation. It had an acceptable temperature coefficient of resistance (TCR) of approximately 0.25%/°C.

2.
Sensors (Basel) ; 22(1)2021 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-35009773

RESUMO

Erection measurements are the most important indicator of male urological disease diagnosis, treatment, and results. Rigiscan has been used widely in studies and diagnoses for nocturnal penile tumescence for evaluating erectile dysfunction by measuring the number and timing of erectile dysfunctions during sleep. However, this device has limitations such as the weight and bulk of the device and has been questioned for its role as a standard for ED Erectile Dysfunction (ED) diagnosis. In this study, we propose a real-time wearable monitoring system that can quantitatively measure the length and circumference of the penis using electronic textiles (E-textile) and carbon nanotube (CNT) sensors. The E-textile sensor is used to measure the length, circumference, and gradient with portability, convenience, and comfort. Sensors were created by coating CNTs on latex for flexibility. The CNT-based latex condom-type sensor in our proposed system shows the length, circumference, and curvature measurements with changes in resistance, and the E-textile performance shows a 1.44% error rate and a cavity radius of 110 to 300. The results of this conceptual study are for supplementary sensor development with a combination of new technologies with alternatives or existing methods for measuring erection function.


Assuntos
Disfunção Erétil , Nanotubos de Carbono , Dispositivos Eletrônicos Vestíveis , Humanos , Masculino , Ereção Peniana , Têxteis
3.
Sensors (Basel) ; 11(3): 2580-91, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22163756

RESUMO

One of the key components of a chemical gas sensor is a MEMS micro-heater. Micro-heaters are used in both semiconductor gas sensors and NDIR gas sensors; however they each require different heat dissipation characteristics. For the semiconductor gas sensors, a uniform temperature is required over a wide area of the heater. On the other hand, for the NDIR gas sensor, the micro-heater needs high levels of infrared radiation in order to increase sensitivity. In this study, a novel design of a poly-Si micro-heater is proposed to improve the uniformity of heat dissipation on the heating plate. Temperature uniformity of the micro-heater is achieved by compensating for the variation in power consumption around the perimeter of the heater. With the power compensated design, the uniform heating area is increased by 2.5 times and the average temperature goes up by 40 °C. Therefore, this power compensated micro-heater design is suitable for a semiconductor gas sensor. Meanwhile, the poly-Si micro-heater without compensation shows a higher level of infrared radiation under equal power consumption conditions. This indicates that the micro-heater without compensation is more suitable for a NDIR gas sensor. Furthermore, the micro-heater shows a short response time of less than 20 ms, indicating a very high efficiency of pulse driving.


Assuntos
Gases/análise , Calefação/instrumentação , Sistemas Microeletromecânicos/instrumentação , Temperatura , Simulação por Computador , Eletricidade , Desenho de Equipamento , Análise de Elementos Finitos , Raios Infravermelhos , Análise Numérica Assistida por Computador