Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Phys Rev E ; 95(5-1): 053113, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28618524

RESUMO

The effects of strongly varying fluid properties, beyond the validity range of the so-called Boussinesq approximation, were experimentally studied in Rayleigh-Bénard (RB) convection. Two experiments were conducted in the same cubical RB convection cell at similar Rayleigh and Prandtl numbers. In one experiment water was used as working fluid and the imposed temperature difference between the top and bottom plates of the cell was such to ensure non-Boussinesq conditions. In the other experiment, taken as a reference for Boussinesq conditions, methanol was used as working fluid, allowing a smaller temperature difference between the plates. In both experiments the instantaneous and time-averaged flow fields were determined experimentally in a vertical cross section of the cell by using particle image velocimetry. Results show a non-Boussinesq effect that manifests itself as an increase of the time-averaged horizontal velocity component close to the bottom wall of the cell and as a global top-bottom asymmetry of the velocity field. This is an experimental study of the whole velocity field of RB convection at non-Boussinesq conditions.

2.
Urol Int ; 95(4): 422-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26159232

RESUMO

INTRODUCTION: Existing nomograms predicting lymph node involvement (LNI) in prostate cancer (PCa) are based on conventional lymphadenectomy. The aim of the study was to develop the first nomogram for predicting LNI in PCa patients undergoing sentinel guided pelvic lymph node dissection (sPLND). MATERIALS AND METHODS: Analysis was performed on 1,296 patients with PCa who underwent radioisotope guided sPLND and retropubic radical prostatectomy (2005-2010). Median prostate specific antigen (PSA): 7.4 ng/ml (IQR 5.3-11.5 ng/ml). Clinical T-categories: T1: 54.8%, T2: 42.4%, T3: 2.8%. Biopsy Gleason sums: ≤ 6: 55.1%, 7: 39.5%, ≥ 8: 5.4%. Multivariate logistic regression models tested the association between all of the above predictors and LNI. Regression-based coefficients were used to develop a nomogram for predicting LNI. Accuracy was quantified using the area under the curve (AUC). RESULTS: The median number of LNs removed was 10 (IQR 7-13). Overall, 17.8% of patients (n = 231) had LNI. The nomogram had a high predictive accuracy (AUC of 82%). All the variables were statistically significant multivariate predictors of LNI (p = 0.001). Univariate predictive accuracy for PSA, Gleason sum and clinical stage was 69, 75 and 69%, respectively. CONCLUSIONS: The sentinel nomogram can predict LNI at a sPLND very accurately and, for the first time, aid clinicians and patients in making important decisions on the indication of a sPLND. The high rate of LN+ patients underscores the sensitivity of sPLND.


Assuntos
Excisão de Linfonodo/métodos , Nomogramas , Neoplasias da Próstata/cirurgia , Biópsia de Linfonodo Sentinela/métodos , Cirurgia Assistida por Computador/métodos , Tecnécio/administração & dosagem , Idoso , Seguimentos , Humanos , Injeções , Linfonodos/patologia , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Pelve , Valor Preditivo dos Testes , Prostatectomia , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/secundário , Reto , Estudos Retrospectivos , Resultado do Tratamento
3.
Microsc Microanal ; 12(5): 406-15, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16984667

RESUMO

A calibration procedure for the detection efficiency of energy dispersive X-ray spectrometers (EDS) used in combination with scanning electron microscopy (SEM) for standardless electron probe microanalysis (EPMA) is presented. The procedure is based on the comparison of X-ray spectra from a reference material (RM) measured with the EDS to be calibrated and a reference EDS. The RM is certified by the line intensities in the X-ray spectrum recorded with a reference EDS and by its composition. The calibration of the reference EDS is performed using synchrotron radiation at the radiometry laboratory of the Physikalisch-Technische Bundesanstalt. Measurement of RM spectra and comparison of the specified line intensities enables a rapid efficiency calibration on most SEMs. The article reports on studies to prepare such a RM and on EDS calibration and proposes a methodology that could be implemented in current spectrometer software to enable the calibration with a minimum of operator assistance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA