Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Ann Noninvasive Electrocardiol ; 29(3): e13119, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38682420

RESUMO

BACKGROUND: To avoid causing a thromboembolic event in patients undergoing catheter ablation for atrial fibrillation (AF), patients are treated with oral anticoagulants (OAC) prior to the procedure. Despite being on anticoagulants, some patients develop a left atrial appendage thrombus (LAAT). To exclude the presence of LAAT, transesophageal ultrasound (TEE) is performed in all patients prior to the procedure. We hypothesized continuous treatment with anticoagulants would result in a low prevalence of LAAT, in patients with low CHA2DS2-VASc score. METHOD: Medical records of consecutive patients planned to undergo AF ablation at Lund University Hospital during the years 2018-2020 were reviewed retrospectively. Examination protocols from transesophageal and transthoracic echocardiography were examined for LAAT and spontaneous echo contrast (SEC). Patients with LAAT and SEC were compared to patients without using Mann-Whitney U-test and Pearson Chi-squared analysis to test for correlation. RESULTS: Of 553 patients, three patients (0.54%) had LAAT, and 18 (3.25%) had spontaneous contrast (SEC). Patients with LAAT or SEC had a higher CHA2DS2-VASc score, more often presented in AF at TEE and less often had a normal sized left atrium. CONCLUSION: There is a low prevalence of LAAT and SEC in patients with AF scheduled for pulmonary vein isolation. Patients with SEC or LAAT tend to have paroxysmal AF less often and more often presented in AF at admission. No patients with CHA2DS2-VASc 0, paroxysmal AF, normal sized left atrium and sinus rhythm at TEE were found to have LAAT or SEC.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Ecocardiografia Transesofagiana , Veias Pulmonares , Trombose , Humanos , Ecocardiografia Transesofagiana/métodos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Masculino , Feminino , Veias Pulmonares/cirurgia , Veias Pulmonares/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Ablação por Cateter/métodos , Estudos Retrospectivos , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Prevalência , Pessoa de Meia-Idade , Idoso , Anticoagulantes/uso terapêutico , Cardiopatias/diagnóstico por imagem , Cardiopatias/epidemiologia
2.
J Cardiovasc Magn Reson ; 25(1): 45, 2023 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-37620886

RESUMO

BACKGROUND: Patients with heart failure and left bundle branch block (LBBB) may receive cardiac resynchronization therapy (CRT), but current selection criteria are imprecise, and many patients have limited treatment response. Hemodynamic forces (HDF) have been suggested as a marker for CRT response. The aim of this study was therefore to investigate left ventricular (LV) HDF as a predictive marker for LV remodeling after CRT. METHODS: Patients with heart failure, EF < 35% and LBBB (n = 22) underwent CMR with 4D flow prior to CRT. LV HDF were computed in three directions using the Navier-Stokes equations, reported in median N [interquartile range], and the ratio of transverse/longitudinal HDF was calculated for systole and diastole. Transthoracic echocardiography was performed before and 6 months after CRT. Patients with end-systolic volume reduction ≥ 15% were defined as responders. RESULTS: Non-responders had smaller HDF than responders in the inferior-anterior direction in systole (0.06 [0.03] vs. 0.07 [0.03], p = 0.04), and in the apex-base direction in diastole (0.09 [0.02] vs. 0.1 [0.05], p = 0.047). Non-responders had larger diastolic HDF ratio compared to responders (0.89 vs. 0.67, p = 0.004). ROC analysis of diastolic HDF ratio for identifying CRT non-responders had AUC of 0.88 (p = 0.005) with sensitivity 57% and specificity 100% for ratio > 0.87. Intragroup comparison found higher HDF ratio in systole compared to diastole for responders (p = 0.003), but not for non-responders (p = 0.8). CONCLUSION: Hemodynamic force ratio is a potential marker for identifying patients with heart failure and LBBB who are unlikely to benefit from CRT. Larger-scale studies are required before implementation of HDF analysis into clinical practice.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Remodelação Ventricular , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética , Bloqueio de Ramo , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Hemodinâmica
3.
ESC Heart Fail ; 9(3): 1864-1874, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35322594

RESUMO

AIMS: Patients awaiting orthotopic heart transplantation (OHT) can be bridged utilizing a left ventricular assist device (LVAD) that reduces left ventricular filling pressures, decreases pulmonary artery wedge pressure, and maintains adequate cardiac output. This study set out to examine the poorly investigated area of if and how pre-treatment with LVAD impacts right ventricular (RV) function following OHT. METHODS AND RESULTS: We prospectively evaluated 59 (LVAD n = 20) consecutive OHT patients. Transthoracic echocardiography (TTE) was performed in conjunction with right heart catheterization (RHC) at 1, 6, and 12 months after OHT. RV function TTE-parameters included tricuspid annular plane systolic excursion (TAPSE), systolic tissue velocity (S'), fractional area change, two-dimensional RV global longitudinal strain and longitudinal strain from the RV lateral wall (RVfree). At 1 month after OHT, the LVAD group had significantly better longitudinal RV function than the non-LVAD group: TAPSE (15 ± 3 mm vs. 12 ± 2 mm, P < 0.001), RV global longitudinal strain (-19.8 ± 2.1% vs. -14.3 ± 2.8%, P < 0.001), and RVfree (-19.8 ± 2.3% vs. -14.1 ± 2.9%, P < 0.001). At this time point, pulmonary vascular resistance (PVR) was also lower [1.2 ± 0.4 Wood Units (WU) vs. 1.6 ± 0.6 WU, P < 0.05] in the LVAD group compared with the non-LVAD group. At 6 and 12 months, no difference was detected in any of the TTE and RHC measured parameters between the two groups. Between 1 and 12 months, all parameters of RV function improved significantly in the non-LVAD group but remained unaltered in the LVAD group. CONCLUSIONS: Our results indicate that pre-treatment with LVAD decreases PVR and is associated with significantly better RV function early following OHT. During the first year following transplantation, RV function progressively improved in the non-LVAD group such that at 6 and 12 months, no difference in RV function was detected between the groups.


Assuntos
Transplante de Coração , Coração Auxiliar , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Função Ventricular Direita
4.
BMC Cardiovasc Disord ; 21(1): 519, 2021 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-34702172

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) restores ventricular synchrony and induces left ventricular (LV) reverse remodeling in patients with heart failure (HF) and dyssynchrony. However, 30% of treated patients are non-responders despite all efforts. Cardiac magnetic resonance imaging (CMR) can be used to quantify regional contributions to stroke volume (SV) as potential CRT predictors. The aim of this study was to determine if LV longitudinal (SVlong%), lateral (SVlat%), and septal (SVsept%) contributions to SV differ from healthy controls and investigate if these parameters can predict CRT response. METHODS: Sixty-five patients (19 women, 67 ± 9 years) with symptomatic HF (LVEF ≤ 35%) and broadened QRS (≥ 120 ms) underwent CMR. SVlong% was calculated as the volume encompassed by the atrioventricular plane displacement (AVPD) from end diastole (ED) to end systole (ES) divided by total SV. SVlat%, and SVsept% were calculated as the volume encompassed by radial contraction from ED to ES. Twenty age- and sex-matched healthy volunteers were used as controls. The regional measures were compared to outcome response defined as ≥ 15% decrease in echocardiographic LV end-systolic volume (LVESV) from pre- to 6-months post CRT (delta, Δ). RESULTS: AVPD and SVlong% were lower in patients compared to controls (8.3 ± 3.2 mm vs 15.3 ± 1.6 mm, P < 0.001; and 53 ± 18% vs 64 ± 8%, P < 0.01). SVsept% was lower (0 ± 15% vs 10 ± 4%, P < 0.01) with a higher SVlat% in the patient group (42 ± 16% vs 29 ± 7%, P < 0.01). There were no differences between responders and non-responders in neither SVlong% (P = 0.87), SVlat% (P = 0.09), nor SVsept% (P = 0.65). In patients with septal net motion towards the right ventricle (n = 28) ΔLVESV was - 18 ± 22% and with septal net motion towards the LV (n = 37) ΔLVESV was - 19 ± 23% (P = 0.96). CONCLUSIONS: Longitudinal function, expressed as AVPD and longitudinal contribution to SV, is decreased in patients with HF scheduled for CRT. A larger lateral contribution to SV compensates for the abnormal septal systolic net movement. However, LV reverse remodeling could not be predicted by these regional contributors to SV.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Estudos de Casos e Controles , Ecocardiografia , Feminino , Coração/fisiologia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Remodelação Ventricular
5.
BMC Cardiovasc Disord ; 21(1): 219, 2021 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-33931021

RESUMO

BACKGROUND: In adult patients with pulmonary arterial hypertension (PAH), right ventricular (RV) failure may worsen rapidly, resulting in a poor prognosis. In this population, non-invasive assessment of RV function is challenging. RV stroke work index (RVSWI) measured by right heart catheterization (RHC) represents a promising index for RV function. The aim of the present study was to comprehensively evaluate non-invasive measures to calculate RVSWI derived by echocardiography (RVSWIECHO) using RHC (RVSWIRHC) as a reference in adult PAH patients. METHODS: Retrospectively, 54 consecutive treatment naïve patients with PAH (65 ± 13 years, 36 women) were analyzed. Echocardiography and RHC were performed within a median of 1 day [IQR 0-1 days]. RVSWIRHC was calculated as: (mean pulmonary arterial pressure (mPAP)-mean right atrial pressure (mRAP)) x stroke volume index (SVI)RHC. Four methods for RVSWIECHO were evaluated: RVSWIECHO-1 = Tricuspid regurgitant maximum pressure gradient (TRmaxPG) x SVIECHO, RVSWIECHO-2 = (TRmaxPG-mRAPECHO) x SVIECHO, RVSWIECHO-3 = TR mean gradient (TRmeanPG) x SVIECHO and RVSWIECHO-4 = (TRmeanPG-mRAPECHO) x SVIECHO. Estimation of mRAPECHO was derived from inferior vena cava diameter. RESULTS: RVSWIRHC was 1132 ± 352 mmHg*mL*m-2. In comparison with RVSWIRHC in absolute values, RVSWIECHO-1 and RVSWIECHO-2 was significantly higher (p < 0.001), whereas RVSWIECHO-4 was lower (p < 0.001). No difference was shown for RVSWIECHO-3 (p = 0.304). The strongest correlation, with RVSWIRHC, was demonstrated for RVSWIECHO-2 (r = 0.78, p < 0.001) and RVSWIECHO-1 ( r = 0.75, p < 0.001). RVSWIECHO-3 and RVSWIECHO-4 had moderate correlation (r = 0.66 and r = 0.69, p < 0.001 for all). A good agreement (ICC) was demonstrated for RVSWIECHO-3 (ICC = 0.80, 95% CI 0.64-0.88, p < 0.001), a moderate for RVSWIECHO-4 (ICC = 0.73, 95% CI 0.27-0.87, p < 0.001) and RVSWIECHO-2 (ICC = 0.55, 95% CI - 0.21-0.83, p < 0.001). A poor ICC was demonstrated for RVSWIECHO-1 (ICC = 0.45, 95% CI - 0.18-0.77, p < 0.001). Agreement of absolute values for RVSWIECHO-1 was - 772 ± 385 (- 50 ± 20%) mmHg*mL*m-2, RVSWIECHO-2 - 600 ± 339 (-41 ± 20%) mmHg*mL*m-2, RVSWIECHO-3 42 ± 286 (5 ± 25%) mmHg*mL*m-2 and for RVSWIECHO-4 214 ± 273 (23 ± 27%) mmHg*mL*m-2. CONCLUSION: The correlation with RVSWIRHC was moderate to strong for all echocardiographic measures, whereas only RVSWIECHO-3 displayed high concordance of absolute values. The results, however, suggest that RVSWIECHO-1 or RVSWIECHO-3 could be the preferable echocardiographic methods. Prospective studies are warranted to evaluate the clinical utility of such measures in relation to treatment response, risk stratification and prognosis in patients with PAH.


Assuntos
Ecocardiografia , Hemodinâmica , Hipertensão Arterial Pulmonar/complicações , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Direita , Idoso , Cateterismo Cardíaco , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Hipertensão Arterial Pulmonar/diagnóstico , Hipertensão Arterial Pulmonar/fisiopatologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/fisiopatologia
6.
Clin Physiol Funct Imaging ; 41(4): 355-365, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33830620

RESUMO

AIMS: Detecting changes in ventricular function after orthotopic heart transplantation (OHT) using transthoracic echocardiography (TTE) is important but interpretation of findings is complicated by lack of data on early graft adaptation. We sought to evaluate echocardiographic measures of ventricular size and function the first year following OHT including speckle tracking derived strain. We also aimed to compare echocardiographic findings to haemodynamic parameters obtained by right heart catheterization (RHC). METHODS AND RESULTS: Fifty OHT patients were examined prospectively with TTE and RHC at 1, 6, and 12 months after OHT. Left ventricle (LV) was assessed with fractional shortening, ejection fraction and systolic tissue velocities. Right ventricular (RV) evaluation included tricuspid annular plane systolic excursion (TAPSE), systolic tissue velocity (S´) and fractional area change (FAC). LV global longitudinal and circumferential strain and RV global longitudinal strain (GLS) and RV lateral wall strain (RVfree) were analysed. No relevant changes occurred in LV echocardiographic parameters, whereas all measures of RV function improved significantly during follow-up. There was an increase in TAPSE (12.4 ± 3.3 mm to 14.4 ± 4.3 mm, p < .01), FAC (36% ± 8% to 41% ± 8%, p < .01), RV GLS (-15.8% ± 4% to -17.8% ± 3.6%, p < .01), and RVfree (-15.5% ± 3.7% to -18.6% ± 3.6%, p < .001). Between 1 and 12 months, pulmonary pressures decreased, whereas pulmonary vascular resistance did not. CONCLUSION: Stable OHT recipients reached steady state regarding LV function 1 month after transplantation. In contrast, RV function displayed gradual improvement the first year following OHT, indicating delayed RV adaptation as compared to the LV. Improved RV function parameters were independent of invasively measured pulmonary pressures.


Assuntos
Transplante de Coração , Disfunção Ventricular Direita , Ecocardiografia , Transplante de Coração/efeitos adversos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Sístole , Função Ventricular Direita
7.
JACC Clin Electrophysiol ; 6(10): 1300-1309, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33092758

RESUMO

OBJECTIVES: This study evaluated if selecting the left ventricular (LV) target segment by echocardiography-derived late mechanical activation, with access to multimodality imaging for scar and venous anatomy, could help to increase responder rates to cardiac resynchronization therapy (CRT). BACKGROUND: LV lead placement is important for clinical outcome, but the optimal strategy for LV lead placement in CRT is still debated. METHODS: This study conducted a prospective, blinded randomized controlled trial on 102 patients with indication for CRT (27% women, 46% with ischemic cardiomyopathy, 63% in New York Heart Association functional class III, 74% with left bundle branch block, and with mean ejection fraction of 23%). Optimal LV lead location was defined as the latest mechanically activated available segment (free of transmural scar), determined by radial strain echocardiography, cardiac computed tomography, and cardiac magnetic resonance (n = 70). The primary endpoint was reduction of LV end-systolic volume by ≥15% at 6 months post-implantation. RESULTS: Patients were followed for 47 ± 21 months. Based on imaging, optimal or adjacent lead placement was feasible in 96% of all cases and was obtained in 83% of the intervention group versus 80% of the control group. Fifty-six percent of the patients were LV end-systolic volume responders compared with the control group (55%) (p = 0.96), and 71% improved ≥1 New York Heart Association functional class (74% vs. 67%; p = 0.43). Death or heart failure hospitalization within 2 years occurred in 6% (2% of the intervention group vs. 10% of the control group; p = 0.07). CONCLUSIONS: Radial strain-guided LV lead placement, in combination with multimodality imaging, did not result in increased clinical or echocardiographic response, nor in a significant reduction of death or heart failure hospitalization. (Combining Myocardial Strain and Cardiac CT to Optimize Left Ventricular Lead Placement in CRT Treatment [CRT Clinic]; NCT01426321).


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Ecocardiografia , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Estudos Prospectivos
8.
BMC Cardiovasc Disord ; 20(1): 259, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32487063

RESUMO

BACKGROUND: Right ventricular (RV) function is a major determinant of outcome in patients with pulmonary hypertension. Cardiac magnetic resonance (CMR) is gold standard to assess RV ejection fraction (RVEFCMR), however this is a crude measure. New CMR measures of RV function beyond RVEFCMR have emerged, such as RV lateral atrio-ventricular plane displacement (AVPDlat), maximum emptying velocity (S'CMR), RV fractional area change (FACCMR) and feature tracking of the RV free wall (FWSCMR). However, it is not fully elucidated if these CMR measures are in parity with the equivalent echocardiography-derived measurements: tricuspid annular plane systolic excursion (TAPSE), S'-wave velocity (S'echo), RV fractional area change (FACecho) and RV free wall strain (FWSecho). The aim of this study was to compare regional RV function parameters derived from CMR to their echocardiographic equivalents in patients with pulmonary hypertension and to RVEFCMR. METHODS: Fifty-five patients (37 women, 62 ± 15 years) evaluated for pulmonary hypertension underwent CMR and echocardiography. AVPDlat, S'CMR, FACCMR and FWSCMR from cine 4-chamber views were compared to corresponding echocardiographic measures and to RVEFCMR delineated in cine short-axis stack. RESULTS: A strong correlation was demonstrated for FAC whereas the remaining measurements showed moderate correlation. The absolute bias for S' was 2.4 ± 3.0 cm/s (relative bias 24.1 ± 28.3%), TAPSE/AVPDlat 5.5 ± 4.6 mm (33.2 ± 25.2%), FWS 4.4 ± 5.8% (20.2 ± 37.5%) and for FAC 5.1 ± 8.4% (18.5 ± 32.5%). In correlation to RVEFCMR, FACCMR and FWSecho correlated strongly, FACecho, AVPDlat, FWSCMR and TAPSE moderately, whereas S' had only a weak correlation. CONCLUSION: This study has demonstrated a moderate to strong correlation of regional CMR measurements to corresponding echocardiographic measures. However, biases and to some extent wide limits of agreement, exist between the modalities. Consequently, the equivalent measures are not interchangeable at least in patients with pulmonary hypertension. The echocardiographic parameter that showed best correlation with RVEFCMR was FWSecho. At present, FACecho and FWSecho as well as RVEFCMR are the preferred methods to assess and follow up RV function in patients with pulmonary hypertension. Future investigations of the CMR right ventricular measures, beyond RVEF, are warranted.


Assuntos
Ecocardiografia , Hipertensão Pulmonar/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Volume Sistólico , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Direita , Idoso , Feminino , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/fisiopatologia
9.
Clin Physiol Funct Imaging ; 39(4): 246-254, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30770630

RESUMO

AIMS: Assessment following heart transplantation (HTx) is routinely performed using transthoracic echocardiography. Differences in long-term mortality following HTx related to donor-recipient matching have been reported, but effects of gender on cardiac size and function are not well studied. The aims of this study were to evaluate differences in echocardiographic characteristics of HTx recipients defined by gender. METHODS AND RESULTS: The study prospectively enrolled 123 (n = 34 female) HTx recipients of which 23 recipients was donor-recipient gender mismatched. Patients were examined with 2-dimensional echocardiography using Philips iE33 ultrasound system. Data were analysed across strata based on recipient gender and gender mismatch. Male recipients had larger left ventricular (LV) mass, thicker septal wall (P<0·001) and larger absolute LV volumes (P<0·001). Mean LV ejection fraction (EF) was higher in females (P<0·05), but no differences in conventional parameters of right ventricular (RV) function were found. Ventricular strain was higher in females than in males: LV global longitudinal strain (P<0·01), RV global longitudinal strain (P<0·05) and RV lateral free wall (P<0·05). The male group receiving a female donor heart had comparable EF and strain parameters to the female group receiving a gender-matched heart. CONCLUSION: We found that female recipient gender was associated with smaller chamber size, higher LV EF and better LV and RV longitudinal strain. Gender-mismatched male recipients appeared to exhibit function parameters similar to gender-matched female recipients. Our results indicate that the gender aspect, analogous to current reference guidelines in general population, should be taken into consideration when examining patients post-HTx.


Assuntos
Ecocardiografia , Transplante de Coração , Coração/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Adulto , Idoso , Feminino , Sobrevivência de Enxerto , Coração/fisiopatologia , Transplante de Coração/efeitos adversos , Transplante de Coração/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores Sexuais , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Função Ventricular Direita , Remodelação Ventricular
10.
Eur J Emerg Med ; 25(2): 78-84, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27893526

RESUMO

OBJECTIVE: Recent studies suggest that administration of O2 in patients with acute myocardial infarction may have negative effects. With the use of cardiac MRI (CMR), we evaluated the effects of supplemental O2 in patients with ST elevation myocardial infarction (STEMI) accepted for acute percutaneous coronary intervention (PCI). MATERIALS AND METHODS: This study was a randomized-controlled trial conducted at two university hospitals in Sweden. Normoxic STEMI patients were randomized in the ambulance to either supplemental O2 (10 l/min) or room air until the conclusion of the PCI. CMR was performed 2-6 days after the inclusion. The primary endpoint was the myocardial salvage index assessed by CMR. The secondary endpoints included infarct size and myocardium at risk. RESULTS: At inclusion, the O2 (n=46) and air (n=49) patient groups had similar patient characteristics. There were no significant differences in myocardial salvage index [53.9±25.1 vs. 49.3±24.0%; 95% confidence interval (CI): -5.4 to 14.6], myocardium at risk (31.9±10.0% of the left ventricle in the O2 group vs. 30.0±11.8% in the air group; 95% CI: -2.6 to 6.3), or infarct size (15.6±10.4% of the left ventricle vs. 16.0±11.0%; 95% CI: -4.7 to 4.1). CONCLUSION: In STEMI patients undergoing acute PCI, we found no effect of high-flow oxygen compared with room air on the size of ischemia before PCI, myocardial salvage, or the resulting infarct size. These results support the safety of withholding supplemental oxygen in normoxic STEMI patients.


Assuntos
Oxigenoterapia/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Adulto , Eletrocardiografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Resultado do Tratamento
11.
Clin Physiol Funct Imaging ; 38(2): 192-199, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27925364

RESUMO

AIMS: Pulmonary hypertension (PH) patients have high mortality due to right ventricular failure. Predictors of poor prognostic outcome are increased right atrial volume (RAV) and elevated mean right atrial pressure (mRAP). Our aim was to determine whether RAV measured with 2D echocardiography (2DE) and 3D echocardiography (3DE) can detect elevated mRAP in patients evaluated for PH. METHODS: Of 85 patients prospectively evaluated for PH, 44 patients (63 ± 15 years, 57% female) had 2DE, 3DE and right heart catheterization within 48 h and were in sinus rhythm. Maximum (RAVmax ) and minimum (RAVmin ) volumes were measured with 3DE. 2D maximum RAV and RA area, inferior vena cava diameter and collapsibility were measured. Invasive mRAP > 8 mmHg was predefined as elevated. RESULTS: RAVmax and RAVmin correlated with mRAP (r = 0·40 and r = 0·35, P<0·05, for both), and so did 2DE maximum RAV (r = 0·42, P = 0·005) and RA area (r = 0·40, P = 0·008). Area under the curve (AUC) from receiver-operating characteristics curves was for 3DE 0·77 for RAVmax , 0·74 for RAVmin , from 2DE, 0·76 for maximum RAV and 0·75 for RA area to discriminate elevated mRAP (P<0·01 for all). PH patients had larger 3D RAV compared with controls (P<0·01). IVC diameter correlated with mRAP (r = 0·41, P = 0·007), but collapsibility did not (P = 0·078). AUC was neither significant for IVC diameter nor for collapsibility for predicting mRAP>8 mmHg. The optimal threshold was 57 ml m-2 for RAVmax , 31 ml m-2 for RAVmin and 36 ml m-2 for 2DE RAV. CONCLUSIONS: Enlarged RA measures with 2DE and 3DE have better discriminatory ability compared with IVC measures, to detect elevated mRAP in patients evaluated for PH.


Assuntos
Função do Átrio Direito , Pressão Atrial , Cardiomegalia/diagnóstico por imagem , Ecocardiografia Tridimensional , Átrios do Coração/diagnóstico por imagem , Hipertensão Pulmonar/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Cardiomegalia/etiologia , Cardiomegalia/fisiopatologia , Feminino , Átrios do Coração/fisiopatologia , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/fisiopatologia , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/fisiopatologia
12.
J Am Soc Echocardiogr ; 31(3): 349-360, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29275986

RESUMO

BACKGROUND: Heart function following heart transplantation (HTx) is influenced by numerous factors. It is typically evaluated using transthoracic echocardiography, but reference values are currently unavailable for this context. The primary aim of the present study was to derive echocardiographic reference values for chamber size and function, including cardiac mechanics, in clinically stable HTx patients. METHODS: The study enrolled 124 healthy HTx patients examined prospectively. Patients underwent comprehensive two-dimensional echocardiographic examinations according to contemporary guidelines. Results were compared with recognized reference values for healthy subjects. RESULTS: Compared with guidelines, larger atrial dimensions were seen in HTx patients. Left ventricular (LV) diastolic volume was smaller, and LV wall thickness was increased. With respect to LV function, both ejection fraction (62 ± 7%, P < .01) and global longitudinal strain (-16.5 ± 3.3%, P < .0001) were lower. All measures of right ventricular (RV) size were greater than reference values (P < .0001), and all measures of RV function were reduced (tricuspid annular plane systolic excursion 15 ± 4 mm [P < .0001], RV systolic tissue Doppler velocity 10 ± 6 cm/sec [P < .0001], fractional area change 40 ± 8% [P < .0001], and RV free wall strain -16.9 ± 4.2% [P < .0001]). Ejection fraction and LV global longitudinal strain were significantly lower in patients with previous rejection. CONCLUSION: The findings of this study indicate that the distribution of routinely used echocardiographic measures differs between stable HTx patients and healthy subjects. In particular, markedly larger RV and atrial volumes and mild reductions in both LV and RV longitudinal strain were evident. The observed differences could be clinically relevant in the assessment of HTx patients, and specific reference values should be applied in this context.


Assuntos
Volume Cardíaco/fisiologia , Ecocardiografia Doppler/métodos , Transplante de Coração , Ventrículos do Coração/diagnóstico por imagem , Volume Sistólico/fisiologia , Transplantados , Função Ventricular Esquerda/fisiologia , Adolescente , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Valores de Referência , Adulto Jovem
13.
Clin Physiol Funct Imaging ; 38(5): 763-771, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29076284

RESUMO

BACKGROUND: Right ventricular (RV) dysfunction may be caused by either pressure or volume overload. RV function is conventionally assessed with echocardiography using tricuspid annular plane systolic excursion (TAPSE), RV fractional area change (RVFAC), tricuspid lateral annular systolic velocity (S') and RV index of myocardial performance (RIMP). The purpose of this study was to evaluate whether RV global longitudinal strain (RVGLS) and RV-free wall strain (RV-free) could add additional information to differentiate these two causes of RV overload. METHODS AND RESULTS: The study enrolled 89 patients with an echocardiographic trans-tricuspid gradient >30 mmHg. Forty-five patients with pulmonary arterial hypertension or chronic thromboembolic pulmonary hypertension (pressure overload) were compared with 44 patients with an atrial septum defect (volume overload). RV size was larger in the volume group (P<0·05). TAPSE and S' were lower in the pressure group (P<0·05, P<0·01). RVFAC was lower in the pressure group (P<0·001) as well as RVGLS (-12·1 ± 3·3% versus -20·2 ± 3·4%, P<0·001) and RV-free (-12·9 ± 3·3% versus -19·4 ± 3·4%, P<0·001). CONCLUSION: In this study, RVGLS and RV-free could more accurately discriminate RV pressure from volume overload than conventional measures. The reason could be that TAPSE and S' are unable to differentiate active deformation from passive entrainment caused by the left ventricle. The pressure group had evidence of marked RV hypertrophy despite standard functional parameters (TAPSE and S) within normal range. This would enhance the value of strain to more sensitively detect abnormal function. A cut-off value of below -16% for RVGLS and RV-free predicts RV pressure overload with high accuracy.


Assuntos
Ecocardiografia Doppler/métodos , Ventrículos do Coração/diagnóstico por imagem , Contração Miocárdica , Volume Sistólico , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Direita , Pressão Ventricular , Idoso , Área Sob a Curva , Fenômenos Biomecânicos , Diagnóstico Diferencial , Feminino , Comunicação Interatrial/complicações , Comunicação Interatrial/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Embolia Pulmonar/complicações , Embolia Pulmonar/fisiopatologia , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Estresse Mecânico , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/fisiopatologia
14.
Echocardiography ; 34(8): 1130-1137, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28664557

RESUMO

BACKGROUND: Although oxygen (O2 ) is routinely used in patients with acute myocardial infarction (AMI), it may have negative effects. In this substudy of the SOCCER trial, we aimed to evaluate the effects of O2 -treatment on myocardial function in patients with ST elevation myocardial infarction (STEMI). METHODS: Normoxic (≥94%) STEMI patients were randomized in the ambulance to either supplemental O2 or room air until the end of the percutaneous coronary intervention (PCI). The patients underwent echocardiography on day 2-3 after the PCI and once again after 6 months. The study endpoints were wall-motion score index (WMSI) and left ventricular ejection fraction (LVEF). RESULTS: Forty-six patients in the O2 group and 41 in the air group were included in the analysis. The index echocardiography showed no significant differences between the groups in WMSI (1.32±0.27 for O2 group vs 1.28±0.28 for air group) or LVEF (47.0±8.5% vs 49.2±8.1%). Nor were there differences at 6 months in WMSI (1.16±0.25 vs 1.14±0.24) or LVEF (53.5±5.8% vs 53.5±6.9%). CONCLUSION: The present findings indicate no harm or benefit of supplemental O2 on myocardial function in STEMI patients. Our results support that it is safe to withhold supplemental O2 in normoxic STEMI patients.


Assuntos
Ecocardiografia/métodos , Ventrículos do Coração/fisiopatologia , Oxigenoterapia/métodos , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Eletrocardiografia , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento
15.
Cardiol J ; 24(4): 374-384, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28198522

RESUMO

BACKGROUND: In select patients with heart failure, cardiac resynchronization therapy (CRT) is the most common complementary treatment besides medical treatment. We aimed to assess the association between post CRT-implant changes in cardiovascular medication and cardiovascular mortality and heart failure hospitalization. METHODS: 211 patients on optimal medical therapy eligible for CRT were retrospectively included in this study (72 ± 7 years, 80% male, 66% left bundle branch block, 48% dilated cardiomyopathy and investigated at baseline and after 6 months. Follow-up with medication, biochemical markers and echocardiography was performed and 3-year mortality data was collected. RESULTS: At 6 months post-implant the cohort was divided into two groups; 157 patients had low dosage furosemide treatment (up to 40 mg) and 54 patients were treated with high dosage (> 40 mg). A composite endpoint of heart failure hospitalization and all-cause mortality was evaluated at 30 months (881 ± 267 days) after the 6-month visit. In multivariate Cox regression analysis, pa-tients in the high dose diuretics group had a higher risk of the primary endpoint (HR 1.9 [1.1-3.4], p = 0.033), but treatment with high dose diuretics was not associated with improved clinical symptoms (r = 0.031, p = 0.64). CONCLUSIONS: High dosage of loop-diuretics was associated with worse medium-term clinical outcome in CRT treated patients. It is unclear whether there is a direct causality between these associations, or if higher prescribed dosage of loop-diuretics is just a marker of more severe disease. Higher dose loop diuretics do not necessarily improve the symptoms and may be harmful to the patient. Prospective trials are warranted to further elucidate these findings. (Cardiol J 2017; 24, 4: 374-384).


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Inibidores de Simportadores de Cloreto de Sódio e Potássio/administração & dosagem , Idoso , Biomarcadores/sangue , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Distribuição de Qui-Quadrado , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Readmissão do Paciente , Modelos de Riscos Proporcionais , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Inibidores de Simportadores de Cloreto de Sódio e Potássio/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
16.
Cardiology ; 132(1): 16-21, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25998033

RESUMO

OBJECTIVES: Despite a lack of scientific evidence, oxygen has long been a part of standard treatment for patients with acute myocardial infarction (AMI). However, several studies suggest that oxygen therapy may have negative cardiovascular effects. We here describe a randomized controlled trial, i.e. Supplemental Oxygen in Catheterized Coronary Emergency Reperfusion (SOCCER), aiming to evaluate the effect of oxygen therapy on myocardial salvage and infarct size in patients with ST elevation myocardial infarction (STEMI) treated with a primary percutaneous coronary intervention (PCI). METHODS: One hundred normoxic STEMI patients accepted for a primary PCI are randomized in the ambulance to either standard oxygen therapy or no supplemental oxygen. All patients undergo cardiovascular magnetic resonance imaging (CMR) 2-6 days after the primary PCI, and a subgroup of 50 patients undergo an extended echocardiography during admission and at 6 months. All patients are followed for 6 months for hospital admission for heart failure and subjective perception of health. The primary endpoint is the myocardial salvage index on CMR. DISCUSSION: Even though oxygen therapy is a part of standard care, oxygen may not be beneficial for patients with AMI and is possibly even harmful. The results of the present and concurrent oxygen trials may change international treatment guidelines for patients with AMI or ischemia.


Assuntos
Angioplastia Coronária com Balão/métodos , Infarto do Miocárdio/terapia , Miocárdio/patologia , Oxigênio/uso terapêutico , Intervenção Coronária Percutânea/efeitos adversos , Eletrocardiografia , Emergências , Humanos , Imageamento por Ressonância Magnética/métodos
17.
Europace ; 16(12): 1779-86, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25031235

RESUMO

AIMS: A cut-off of 9.8% maximum speckle-tracking radial strain in the segment with the latest mechanical delay has been proposed as predictive for selecting the best left ventricular lead placement for positive response on cardiac resynchronization therapy (CRT). However, pacing transmural scar should be avoided, and the purpose of this study was to evaluate the ability of echocardiographic radial strain to predict the presence of scar in the left ventricle segments. METHODS AND RESULTS: A total of 404 left ventricular segments were analysed, from 34 patients eligible for CRT. Pre-operative cardiac magnetic resonance (CMR) and echocardiography were performed, and maximal strain values from echocardiography speckle tracking were compared with CMR data. Hypokinesia and strain values showed a strong correlation (P < 0.001). Even though segments with CMR-verified scar had lower strain values than segments without scar (14.8 ± 7 vs. 16.0 ± 10), the predictive value of the proposed 9.8% cut-off was low (sensitivity 33% and specificity 72%). Scar burden was higher in ischaemic patients (13.5 vs. 5.3% P = 0.0001). Relative difference in strain values (target segment strain compared with the average strain value of the adjacent segments) was higher if there was transmural scar in the target segment as compared with a hypokinetic but viable target segment (87 vs. 38% difference, P = 0.03). CONCLUSION: Speckle tracking radial strain should ideally be complemented by CMR for accurate assessment of viability, especially for patients with ischaemic aetiology of heart failure where transmural scar is more common. Comparison of strain values with the adjacent segments may be helpful for assessing viability.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Ecocardiografia/métodos , Técnicas de Imagem por Elasticidade/métodos , Eletrodos Implantados , Ventrículos do Coração/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Implantação de Prótese/métodos , Idoso , Anisotropia , Terapia de Ressincronização Cardíaca/métodos , Módulo de Elasticidade , Feminino , Ventrículos do Coração/cirurgia , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estresse Mecânico , Resistência à Tração
18.
Eur Heart J Cardiovasc Imaging ; 15(5): 523-31, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24243143

RESUMO

AIMS: To evaluate the feasibility and incremental value of using an integrated bullseye model for presenting data from cardiac computed tomography (CT) and magnetic resonance imaging (MRI) in combination with echocardiography evaluation of segmental mechanical delay for guiding optimal left ventricular lead placement in cardiac resynchronization therapy (CRT). METHODS AND RESULTS: Thirty-nine patients (69 ± 9.7 years, 77% male, 82% with LBBB, 54% with ischaemic cardiomyopathy, 82% New York Heart Association classification of heart failure III) eligible for CRT were included. The left ventricular segment with the latest mechanical activation was determined by echocardiography with speckle tracking radial strain. Cardiac CT scan was used for anatomical evaluation of the coronary sinus and its branches. Cardiac MRI was used for evaluation of viability. A composite bullseye plot was constructed, indicating the most appropriate site for left ventricle (LV) lead placement. The latest mechanical delay was in the basal-anterior (3%), basal-inferior (3%), basal-inferolateral (13%), basal-anterolateral (21%), mid-anterior (8%), mid-inferior (3%), mid-inferolateral (34%), and mid-anterolateral (16%) segment. There were on average 2.5 ± 0.8 veins of suitable sizes (≥1.5 mm in diameter). A preoperative combined bullseye plot indicated that in 53% of the patients, there was a matching vein in the segment with the latest mechanical delay. If immediately adjacent segments were included, an optimal placement was possible in 95% of the patients. At 6 months, there was a statistically significant reduction in the left ventricular end systolic volume and the left ventricular ejection fraction was improved (P < 0.01). CONCLUSION: Presenting data from echocardiography, cardiac CT, and MRI in a combined bullseye plot is both feasible and convenient for indicating the most appropriate site for LV lead placement. An optimal electrode position can be suggested in almost all patients.


Assuntos
Terapia de Ressincronização Cardíaca , Ecocardiografia/métodos , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Estudos de Viabilidade , Feminino , Compostos Heterocíclicos , Humanos , Interpretação de Imagem Assistida por Computador , Iohexol , Masculino , Compostos Organometálicos
19.
Eur Heart J Acute Cardiovasc Care ; 2(2): 131-6, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24222822

RESUMO

Patent foramen ovale (PFO) is present in approximately 25% of the general population. PFO is characterized by intermittent shunting of blood from the right to the left atrium, especially in the context of increased right-sided filling pressures, with risk of paradoxical embolism. We describe a 69-year-old woman presenting with acute chest pain, severe dyspnoea, and acute inferolateral ST-segment elevation on the electrocardiogram. The patient was diagnosed with myocardial infarction and failure of the right cardiac ventricle, which was considered to be secondary to extensive pulmonary embolism leading to increased filling pressures and paradoxical coronary embolism. The patient underwent emergent percutaneous interventions with coronary thrombus extraction and pulmonary thrombus fragmentation and local thrombolysis. The patient was free of symptoms at follow up 6 months later and echocardiography showed substantially improved right ventricular function. We discuss issues related to the diagnosis, treatment, and secondary prevention for patients with concomitant pulmonary and coronary arterial thrombosis.


Assuntos
Angioplastia Coronária com Balão/métodos , Embolia/terapia , Insuficiência Cardíaca/terapia , Trombectomia/métodos , Disfunção Ventricular Direita/terapia , Idoso , Oclusão Coronária/etiologia , Oclusão Coronária/terapia , Estenose Coronária/etiologia , Estenose Coronária/terapia , Vasos Coronários , Feminino , Insuficiência Cardíaca/etiologia , Humanos , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/terapia , Embolia Pulmonar/complicações , Embolia Pulmonar/terapia , Resultado do Tratamento , Disfunção Ventricular Direita/etiologia
20.
Europace ; 15(10): 1445-52, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23515337

RESUMO

AIMS: Atrial fibrillatory rate (AFR) is considered a non-invasive index of atrial remodelling. Low AFR has been associated with favourable outcome of interventions in patients with persistent atrial fibrillation (AF). However, AFR has never been studied in unselected patients with short duration of AF, prone to regain sinus rhythm (SR) spontaneously. The aim of the study was to assess if AFR can predict spontaneous conversion in patients with recent-onset AF. METHODS AND RESULTS: Files of consecutive patients with AF < 48 h seeking emergency room care during a 12-month period were screened (n = 225). Patients with thyroid illness, acute ischaemic heart disease (IHD) or acute congestive heart failure, significant valvular heart disease, congenital heart disease, history of cardiac surgery or catheter ablation, or on class I/III antiarrhythmics were excluded. Atrial fibrillatory rate was obtained by QRST cancellation and time frequency analysis of electrocardiogram at admission. The study population comprised 148 patients (age 64 ± 13 years, 52 men), of whom 48 converted to SR within 18 h. Those converting spontaneously comprised more women, had a higher prevalence of first-ever AF episode, IHD, and a lower AFR. The multivariate analysis revealed: AFR < 350 fibrillations per minute [odds ratio (OR) 3.7, 95% confidence interval (CI) 1.3-10.5, P = 0.016], IHD (OR 5.7, 95% CI 1.5-22.4, P = 0.012) and first-ever AF episode (OR 4.1, 95% CI 1.3-13.0, P = 0.015) as independent predictors of spontaneous conversion. CONCLUSION: A low AFR was predictive of spontaneous conversion in patients with recent-onset AF. Along with first-ever AF episode and IHD, AFR can be used in assessing likelihood of spontaneous conversion, if proven in prospective studies.


Assuntos
Fibrilação Atrial/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Eletrocardiografia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Prevalência , Prognóstico , Sistema de Registros , Remissão Espontânea , Estudos Retrospectivos , Fatores de Risco , Suécia/epidemiologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...