Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Knee Surg ; 36(2): 146-152, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34187069

RESUMO

Periprosthetic fractures around a total knee arthroplasty (TKA), comminuted and intra-articular femur fractures, or fracture nonunions in osteoporotic bone represent technically challenging problems. This is particularly true when the fracture involves a loose femoral component or the pattern results in suboptimal fixation potential. These clinical indications often arise in an older and comorbid patient population in whom a principal goal of treatment includes allowing for early mobilization. Limited data indicate that arthroplasty via distal femoral replacement (DFR) is a reasonable alternative to open reduction and internal fixation, allowing for early ambulation with low complication rates. We performed a retrospective review of trauma and arthroplasty surgeries at three tertiary referral institutions. Adult patients treated for the above with a DFR were included. Patients with active infection, open and/or high-energy injuries and revisions unrelated to fracture were excluded. Patient demographics, treatment details, and outcomes were assessed. Between 2002 and 2017, 90 DFR's were performed for the above indications with a mean follow-up of 24 months. Postoperatively, 80 patients (88%) were allowed to weight bear as tolerated, and at final follow-up, 9 patients (10%) remained dependent on a wheelchair. The average arc of motion at final follow-up was 95 degrees. There were seven (8%) implant-related complications requiring secondary surgeries: two infections, one with associated component loosening; one fracture of the hinge mechanism and one femoral component failure in conjunction with a patellofemoral dislocation (both requiring revision); one case of patellofemoral arthrosis in a patient with an unresurfaced patella; one periprosthetic fracture with associated wound dehiscence; and one case of arthrofibrosis. In each of these cases, only modular components of the DFR were exchanged. All nonmodular components cemented into the femur or tibia were retained. DFR provides a viable reconstruction option in the treatment of acute distal femur fractures, periprosthetic femur fractures, and fracture nonunions. We noted that in an elderly patient population with high comorbidities, the complication and secondary surgery rates remained relatively low, while allowing for immediate weight bearing.


Assuntos
Artroplastia do Joelho , Fraturas do Fêmur , Fraturas Intra-Articulares , Fraturas Periprotéticas , Adulto , Humanos , Idoso , Deambulação Precoce/efeitos adversos , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/etiologia , Fêmur/cirurgia , Artroplastia do Joelho/efeitos adversos , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Fixação Interna de Fraturas/métodos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Fraturas Intra-Articulares/cirurgia , Estudos Retrospectivos , Reoperação/efeitos adversos
2.
Fluids Barriers CNS ; 17(1): 4, 2020 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-31959193

RESUMO

BACKGROUND: Developing novel therapeutic agents to treat amyotrophic lateral sclerosis (ALS) has been difficult due to multifactorial pathophysiologic processes at work. Intrathecal drug administration shows promise due to close proximity of cerebrospinal fluid (CSF) to affected tissues. Development of effective intrathecal pharmaceuticals will rely on accurate models of how drugs are dispersed in the CSF. Therefore, a method to quantify these dynamics and a characterization of differences across disease states is needed. METHODS: Complete intrathecal 3D CSF geometry and CSF flow velocities at six axial locations in the spinal canal were collected by T2-weighted and phase-contrast MRI, respectively. Scans were completed for eight people with ALS and ten healthy controls. Manual segmentation of the spinal subarachnoid space was performed and coupled with an interpolated model of CSF flow within the spinal canal. Geometric and hydrodynamic parameters were then generated at 1 mm slice intervals along the entire spine. Temporal analysis of the waveform spectral content and feature points was also completed. RESULTS: Comparison of ALS and control groups revealed a reduction in CSF flow magnitude and increased flow propagation velocities in the ALS cohort. Other differences in spectral harmonic content and geometric comparisons may support an overall decrease in intrathecal compliance in the ALS group. Notably, there was a high degree of variability between cases, with one ALS patient displaying nearly zero CSF flow along the entire spinal canal. CONCLUSION: While our sample size limits statistical confidence about the differences observed in this study, it was possible to measure and quantify inter-individual and cohort variability in a non-invasive manner. Our study also shows the potential for MRI based measurements of CSF geometry and flow to provide information about  the hydrodynamic environment of the spinal subarachnoid space. These dynamics may be studied further to understand the behavior of CSF solute transport in healthy and diseased states.


Assuntos
Esclerose Lateral Amiotrófica/líquido cefalorraquidiano , Esclerose Lateral Amiotrófica/diagnóstico por imagem , Líquido Cefalorraquidiano/diagnóstico por imagem , Imageamento por Ressonância Magnética , Espaço Subaracnóideo/diagnóstico por imagem , Adulto , Líquido Cefalorraquidiano/fisiologia , Simulação por Computador , Humanos , Hidrodinâmica , Imageamento por Ressonância Magnética/métodos , Masculino , Modelos Biológicos , Canal Medular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...