Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
1.
Clin Imaging ; 110: 110142, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38696997

RESUMO

PURPOSE: The purpose of this study was to evaluate long-term morphologic changes occurring in the liver after TIPS creation with correlation with hepatic function to gain insight on the physiologic impact of TIPS on the liver. METHODS: This retrospective study included patients who underwent TIPS creation between 2005 and 2022 and had contrasted CT or MRI studies prior to and between 1 and 2 years post procedure. Strict exclusion criteria were applied to avoid confounding. Parenchymal volume and vessel measurements were assessed on the pre- and post-TIPS CT or MRI and MELD scores calculated. RESULTS: Of 580 patients undergoing TIPS creation, 65 patients (mean age, 55 years; 36 males) had pre-TIPS and post-TIPS imaging meeting inclusion criteria at median 16.5 months. After TIPS, the mean MELD score increased (12.9 to 15.4; p = 0.008) and total liver volume decreased (1730 to 1432 mL; p < 0.001). However, the magnitude of volume change did not correlate with MELD change. Neither portosystemic gradient nor TIPS laterality correlated with total or lobar hepatic volume changes or MELD changes. The main portal vein diameter increased (15.0 to 18.7 mm; p < 0.001). Thrombosis of the hepatic vein used for TIPS creation resulted in a mean increase in MELD of +4.1 compared to -2.1 in patients who had a patent and normal hepatic vein (p = 0.007). CONCLUSIONS: Given lack of correlation between portosystemic gradient, hepatic atrophy, hepatic function, and TIPS laterality, the alterations in portal flow dynamics after TIPS may not be impactful to hepatic function. However, hepatic vein patency after TIPS correlated with improved hepatic function.


Assuntos
Fígado , Imageamento por Ressonância Magnética , Derivação Portossistêmica Transjugular Intra-Hepática , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Resultado do Tratamento
3.
Artigo em Inglês | MEDLINE | ID: mdl-38335943

RESUMO

OBJECTIVE: Cement volumes are increasingly linked to orthopedic oncology and neurosurgical outcomes (construct durability, adjacent fracture), but manual cement volumetry remains time prohibitive. The authors aim to report performance of PACS-integrated volumetric software specifically for barium-enhanced polymethylmethacrylate cement. METHODS: Institutional review board-approved single-institution retrospective review of patients from 2019-2022 undergoing kyphoplasty for pathological compression fractures with a quantitative cement infuser providing true cement volume. An operator blinded to true cement volumes retrospectively performed software-assisted volumetry on follow-up computed tomography scans. RESULTS: Included were 91 kyphoplasty levels in 56 patients: mean age, 62 years (range, 34-85 years), 73% female. True cement volume (available for 44 of 66 procedures) was mean 4.5 mL per level (range, 1.2-15.6 mL). Measured cement volume (available for all procedures) yielded a mean of 6.1 mL per level (range, 1.5-27.9 mL). For the 57 levels (39 patients) where both true and measured cement volumes were available, linear regression intercept and slope were 1.46 (95% CI = 0.97-1.95, P < 0.001) and 0.52 (CI = 0.47-0.57, P < 0.001), respectively, suggesting measured volume averaged 1.46 mL greater than true volume, with each additional milliliter of measured volume corresponding to approximately 0.52 mL of true volume. There was no significant difference in the relationship between estimated and actual cement volume in thoracic levels (intercept = -0.24, CI = -1.13 to 0.66, P = 0.61; slope = 0.03, CI = -0.14 to 0.19, P = 0.73) compared with lumbar levels. The goodness-of-fit of the regression model was strong (R2 = 0.81). Discrepancies ranged from 90% underestimation to 52% overestimation; average, 17% overestimation. CONCLUSIONS: Semi-automated volumetry maintained a strong correlation with true volumes across the thoracic and lumbar curvatures, overestimating cement volume by a mean of 17% or 1.46 mL.

5.
J Ultrasound ; 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38332311

RESUMO

RATIONAL AND OBJECTIVES: To increase utilization of contrast-enhanced ultrasound (CEUS) during ultrasound-guided targeted liver biopsies. MATERIAL AND METHODS: Two educational training interventions performed to increase use of CEUS. First, 14 radiologists (fellowship-trained in Abdominal Imaging) given didactic teaching and case presentations on the use of CEUS. Second, hands-on teaching on how to use CEUS provided to the same group. To determine the efficacy of these two interventions, radiologists completed anonymous surveys to determine the level of understanding and acceptability of using CEUS before and 6 months after CEUS training. In addition, the percentage of CEUS assisted liver biopsies was compared for the 6 months before and 6 months after the training. RESULTS: Pre-training survey completed by 11 radiologists and post-training survey completed by 9 radiologists. Before training, 11% survey responders use CEUS routinely, whereas 89% never or rarely used it. After training, 54% of respondents were new users and 100% reported they planned to use CEUS in the future. Unfamiliarity (71%) was the main reason for not using it. After training, 25% reported lack of comfort with using CEUS as the main reason for not using CEUS. During six months before training, CEUS was administered in 6% (10/172) of targeted liver biopsies. Six months after training, CEUS was used nearly twice as often (10%, 16/160, P = 0.09, 1-sided Boschloo test). The number of radiologists using CEUS increased to 57% (8/14) after training compared to 20% (3/14, P = 0.03, 1-sided Boschloo) before training. CONCLUSION: Educational training intervention increases use of CEUS during ultrasound-guided targeted liver biopsies.

9.
Genetics ; 226(3)2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38142447

RESUMO

Circadian clocks are endogenous timekeeping mechanisms that coordinate internal physiological responses with the external environment. EARLY FLOWERING3 (ELF3), PSEUDO RESPONSE REGULATOR (PRR9), and PRR7 are essential components of the plant circadian clock and facilitate entrainment of the clock to internal and external stimuli. Previous studies have highlighted a critical role for ELF3 in repressing the expression of PRR9 and PRR7. However, the functional significance of activity in regulating circadian clock dynamics and plant development is unknown. To explore this regulatory dynamic further, we first employed mathematical modeling to simulate the effect of the prr9/prr7 mutation on the elf3 circadian phenotype. These simulations suggested that simultaneous mutations in prr9/prr7 could rescue the elf3 circadian arrhythmia. Following these simulations, we generated all Arabidopsis elf3/prr9/prr7 mutant combinations and investigated their circadian and developmental phenotypes. Although these assays could not replicate the results from the mathematical modeling, our results have revealed a complex epistatic relationship between ELF3 and PRR9/7 in regulating different aspects of plant development. ELF3 was essential for hypocotyl development under ambient and warm temperatures, while PRR9 was critical for root thermomorphogenesis. Finally, mutations in prr9 and prr7 rescued the photoperiod-insensitive flowering phenotype of the elf3 mutant. Together, our results highlight the importance of investigating the genetic relationship among plant circadian genes.


Assuntos
Proteínas de Arabidopsis , Arabidopsis , Relógios Circadianos , Proteínas de Arabidopsis/genética , Proteínas de Arabidopsis/metabolismo , Relógios Circadianos/genética , Ritmo Circadiano/genética , Regulação da Expressão Gênica de Plantas , Fenômenos Fisiológicos Vegetais , Fatores de Transcrição/genética , Fatores de Transcrição/metabolismo
10.
Nucl Med Commun ; 45(1): 61-67, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37901924

RESUMO

PURPOSE: To report efficiency of resin y90 delivery using SIROS via 175 cm TruSelect microcatheter with double-flush protocol (40 ml dextrose total). METHODS: IRB-approved retrospective review of all patients undergoing SIROS injection of y90 Sir-Spheres via TruSelect from 2019 through 2022 at one quaternary-care academic institution, including medical records. RESULTS: Included were 48 infusions in 25 patients across 11 cancer histologies. Mean planned, delivered, and residual activities were 28 ± 17, 27 ± 17, 1.1 ± 0.56 mCi respectively (mean residual 4.9% ± 2.8%) across flex-dosing precalibrations including 1-day, 2-day, and 3-day SIROS (4/51, 16/51, and 28/51). Mean liver treatment volume was 483 ± 306 ml with target dose mean of 128 ± 26 Gy in non-segmentectomy cases; Radiation segmentectomy was performed in 15/48 (31%). Arterial stasis was documented in 9/48 (19%) of cases. Use of a 3-day precalibrated SIROS dose, use of activity <10 mCi, treatment of smaller liver volumes (<200 ml) and documentation of stasis were associated with higher residual activity ( P  = 0.025, P  = 0.0007, P  = 0.0177, and P  = 0.049, respectively) were associated with higher residuals. CONCLUSION: Combining the new technologies of SIROS and the Truselect microcatheter with a double-flush protocol yielded <10% residual in 94% of y90 infusions. Future studies may clarify if the predictors of high residual dose seen here may warrant microcatheter-specific considerations for dosimetry or dose preparation at the Radiopharmacy level.


Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Injeções , Estudos Retrospectivos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/tratamento farmacológico , Radioisótopos de Ítrio/uso terapêutico , Carcinoma Hepatocelular/terapia
12.
J Vasc Interv Radiol ; 34(10): 1680-1689.e2, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37400054

RESUMO

PURPOSE: To compare the laboratory markers of acute liver injury after transjugular intrahepatic portosystemic shunt (TIPS) creation performed using intravascular ultrasound (IVUS) guidance with those using other techniques. MATERIALS AND METHODS: This single-center, retrospective study examined 293 TIPS procedures performed between 2014 and 2022 (160 men; mean age, 57.4 years; 71.7% with ascites, 158 with IVUS). Laboratory changes on postprocedural day (PPD) 1 were classified based on Common Terminology Criteria for Adverse Events (CTCAE) grades and were compared between IVUS and non-IVUS cases. RESULTS: IVUS cases had a lower baseline Model for End-Stage Liver Disease (MELD) score (12.5 vs 13.7, P = .016), higher pre- (16.8 vs 15.2, P = .009), and post-TIPS (6.6 vs 5.4 mm Hg, P < .001) pressure gradient, smaller stent diameter (9.2 vs 9.9 mm, P < .001), and fewer needle passes (2.4 vs 4.2, P < .001). IVUS predicted a lower PPD 1 CTCAE grade for aspartate transaminase (8.0% vs 22.2% grade ≥ 2, P = .010), alanine transaminase (ALT) (2.2% vs 7.1%, P = .017), and bilirubin (9.4% vs 26.2%, P < .001), findings confirmed using multivariable regression and propensity score analysis. IVUS predicted fewer adverse events (1.3% vs 8.1%, P = .008) and an increased likelihood of PPD 1 discharge (81% vs 59%, P = .004). IVUS was not associated with differences in PPD 30 MELD scores or 30-day survival; however, higher PPD 1 ALT (ß = 1.96, P = .008) and bilirubin levels (ß = 1.38, P = .004) predicted larger PPD 30 MELD score increase. Higher increases in ALT level predicted worse 30-day survival (hazard ratio, 1.93; P = .021). CONCLUSION: IVUS resulted in less laboratory evidence of acute liver injury immediately following TIPS creation.

13.
J Vasc Surg Cases Innov Tech ; 9(3): 101180, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37388670

RESUMO

Management of pancreaticoduodenal artery aneurysms (PDAAs) and gastroduodenal artery aneurysms (GDAAs) with concomitant celiac occlusion represents a challenging clinical scenario. Here, we describe a 62-year-old female with PDAA and GDAA complicated by celiac artery occlusion due to median arcuate ligament syndrome. We used a staged, minimally invasive approach consisting of: (1) a robotic median arcuate ligament release; (2) endovascular celiac artery stenting; and (3) visceral aneurysm coiling. The findings from this case report represent a novel treatment strategy for the management of PDAA/GDAA with celiac artery compression secondary to median arcuate ligament syndrome.

14.
Eur Radiol ; 33(12): 8745-8753, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37382617

RESUMO

OBJECTIVES: To determine whether image reconstruction with a higher matrix size improves image quality for lower extremity CTA studies. METHODS: Raw data from 50 consecutive lower extremity CTA studies acquired on two MDCT scanners (SOMATOM Flash, Force) in patients evaluated for peripheral arterial disease (PAD) were retrospectively collected and reconstructed with standard (512 × 512) and higher resolution (768 × 768, 1024 × 1024) matrix sizes. Five blinded readers reviewed representative transverse images in randomized order (150 total). Readers graded image quality (0 (worst)-100 (best)) for vascular wall definition, image noise, and confidence in stenosis grading. Ten patients' stenosis scores on CTA images were compared to invasive angiography. Scores were compared using mixed effects linear regression. RESULTS: Reconstructions with 1024 × 1024 matrix were ranked significantly better for wall definition (mean score 72, 95% CI = 61-84), noise (74, CI = 59-88), and confidence (70, CI = 59-80) compared to 512 × 512 (wall = 65, CI = 53 × 77; noise = 67, CI = 52 × 81; confidence = 62, CI = 52 × 73; p = 0.003, p = 0.01, and p = 0.004, respectively). Compared to 512 × 512, the 768 × 768 and 1024 × 1024 matrix improved image quality in the tibial arteries (wall = 51 vs 57 and 59, p < 0.05; noise = 65 vs 69 and 68, p = 0.06; confidence = 48 vs 57 and 55, p < 0.05) to a greater degree than the femoral-popliteal arteries (wall = 78 vs 78 and 85; noise = 81 vs 81 and 84; confidence = 76 vs 77 and 81, all p > 0.05), though for the 10 patients with angiography accuracy of stenosis grading was not significantly different. Inter-reader agreement was moderate (rho = 0.5). CONCLUSION: Higher matrix reconstructions of 768 × 768 and 1024 × 1024 improved image quality and may enable more confident assessment of PAD. CLINICAL RELEVANCE STATEMENT: Higher matrix reconstructions of the vessels in the lower extremities can improve perceived image quality and reader confidence in making diagnostic decisions based on CTA imaging. KEY POINTS: • Higher than standard matrix sizes improve perceived image quality of the arteries in the lower extremities. • Image noise is not perceived as increased even at a matrix size of 1024 × 1024 pixels. • Gains from higher matrix reconstructions are higher in smaller, more distal tibial and peroneal vessels than in femoropopliteal vessels.


Assuntos
Artérias , Doença Arterial Periférica , Humanos , Constrição Patológica , Estudos Retrospectivos , Extremidade Inferior/diagnóstico por imagem , Extremidade Inferior/irrigação sanguínea , Angiografia por Tomografia Computadorizada/métodos , Doença Arterial Periférica/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
15.
Plant J ; 114(2): 390-402, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36794876

RESUMO

Directional movements impact the ability of plants to respond and adjust their growth accordingly to the prevailing light environment. The plasma-membrane associated protein, ROOT PHOTOTROPISM 2 (RPT2) is a key signalling component involved in chloroplast accumulation movement, leaf positioning, and phototropism, all of which are regulated redundantly by the ultraviolet/blue light-activated AGC kinases phototropin 1 and 2 (phot1 and phot2). We recently demonstrated that members of the NON-PHOTOTROPIC HYPOCOTYL 3 (NPH3)/RPT2-like (NRL) family in Arabidopsis thaliana, including RPT2, are directly phosphorylated by phot1. However, whether RPT2 is a substrate for phot2, and the biological significance of phot phosphorylation of RPT2 remains to be determined. Here, we show that RPT2 is phosphorylated by both phot1 and phot2 at a conserved serine residue (S591) within the C-terminal region of the protein. Blue light triggered the association of 14-3-3 proteins with RPT2 consistent with S591 acting as a 14-3-3 binding site. Mutation of S591 had no effect on the plasma membrane localization of RPT2 but reduced its functionality for leaf positioning and phototropism. Moreover, our findings indicate that S591 phosphorylation within the C-terminus of RPT2 is required for chloroplast accumulation movement to low level blue light. Taken together, these findings further highlight the importance of the C-terminal region of NRL proteins and how its phosphorylation contributes to phot receptor signalling in plants.


Assuntos
Proteínas de Arabidopsis , Arabidopsis , Arabidopsis/metabolismo , Fototropismo/genética , Fosforilação , Fototropinas/genética , Fototropinas/metabolismo , Proteínas de Arabidopsis/metabolismo , Proteínas Serina-Treonina Quinases/genética , Proteínas Serina-Treonina Quinases/metabolismo , Plantas Geneticamente Modificadas/genética , Luz , Folhas de Planta/metabolismo , Cloroplastos/metabolismo , Fosfoproteínas/metabolismo
17.
J Vasc Interv Radiol ; 34(4): 710-715, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36718760

RESUMO

PURPOSE: To compare the diagnostic accuracy and adverse event rates of intravascular ultrasound (US)-guided transvenous biopsy (TVB) versus those of computed tomography (CT)-guided percutaneous needle biopsy (PNB) for retroperitoneal (RP) lymph nodes. MATERIALS AND METHODS: In this single-institution, retrospective study, 32 intravascular US-guided TVB procedures and a sample of 34 CT-guided PNB procedures for RP lymph nodes where targets were deemed amenable to intravascular US-guided TVB were analyzed. Procedural metrics, including diagnostic accuracy, defined as diagnostic of malignancy or a clinically verifiable benign result, and adverse event rates were compared. RESULTS: The targets of intravascular US-guided TVB were primarily aortocaval (47%, 15/32) or precaval (34%, 11/32), whereas those of CT-guided PNB were primarily right pericaval (44%, 15/34) or retrocaval (44%, 15/34) (P < .001). The targets of intravascular US-guided TVB averaged 2.4 cm in the long axis (range, 1.3-3.7 cm) compared with 2.9 cm (range, 1.4-5.7 cm) for those of CT-guided PNB (P = .02). There was no difference in the average number of needle passes (3.8 for intravascular US-guided TVB vs 3.9 for CT-guided PNB; P = .68). The diagnostic accuracy was 94% (30/32) and the adverse event rate was 3.1% (1/32) for intravascular US-guided TVB, similar to those of CT-guided PNB (accuracy, 91% [31/34]; adverse event rate, 2.9% [1/34]). CONCLUSIONS: Intravascular US-guided TVB had a diagnostic accuracy and adverse event rate similar to CT-guided PNB for RP lymph nodes, indicating that intravascular US-guided TVB may be as safe and effective as conventional biopsy approaches for appropriately selected targets.


Assuntos
Biópsia Guiada por Imagem , Linfonodos , Humanos , Estudos Retrospectivos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Tomografia Computadorizada por Raios X , Ultrassonografia de Intervenção/efeitos adversos
18.
Clin Imaging ; 94: 103-107, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36525881

RESUMO

BACKGROUND: Intraprocedural Cone Beam CT (CBCT) is assessed to examine if use improves diagnosis and embolization rates of acute lower GI bleed (LGIB) and if automatic vessel detection (AVD) software can identify feeding vessels (FV) for embolization. METHODS: Patients with inconclusive DSA findings had CBCT and retrospective analysis with AVD software (Innova 3100, GE Company, USA). Technical success was defined as the ability to detect a lower GIB site while clinical success was defined as successful embolization without evidence of rebleeding or death within 30 days. AVD technical success was defined by the ability to identify the FV on both CTA and CBCT upon independent review by 3 blinded IRs, who also assigned a degree of certainty on a 5-point Likert scale. RESULTS: 74 patients in total were treated for lower GI bleed of which 34 had indeterminate DSA. Of those, 10 patients received DSA only, of which 1 was super selective. 24 patients with GIB on pre-procedural CTA and inconclusive DSA underwent CBCT. Use of CBCT identified 9 bleeds not seen on DSA and an additional source artery in 1 case representing a 42% change in intraprocedural management as all findings were embolized. When a bleed could not be identified on CBCT, but the FV could be identified on CTA, the same suspected FV could be selected on AVD 62% of the time with an average certainty of 4.0. CONCLUSION: CBCT is useful in the intraprocedural detection of GIB when DSA is indeterminate. Furthermore, AVD software can feasibly be utilized to accurately identify FVs for empiric treatment when intraprocedural imaging is inconclusive. LEVEL OF EVIDENCE: Level III, therapeutic study.


Assuntos
Embolização Terapêutica , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Estudos Retrospectivos , Angiografia Digital/métodos , Embolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...