Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 8848, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-37258555

RESUMO

Prehistoric monuments often constitute evident landmarks and sometimes, after falling into disuse, fascinated local people enough to stimulate speculations about their origin over time. According to legend, the Hill of Udine (NE Italy) was built by Attila the Hun's soldiers, but its origin (natural or anthropogenic) has been debated until now. Our research analyzed five new 40-m long stratigraphic cores, investigating for the first time the total thickness of the hill and compared the data with the available archaeological information. Moreover, we considered other hills and mounds in northern Italy and other European regions where folklore traditions relate their origin to Attila. The geoarchaeological and ethnographic data prove that the Hill of Udine is a Bronze Age anthropogenic mound erected between 1400 and 1150 BCE and that, later, folklore has transformed the ancestral memory of its origin into legend. By measuring 30 m in height and over 400,000 m3 in volume, the flat-topped hill is the largest prehistoric mound in Europe. This discovery reveals unprecedented skills in earth construction and confirms significant anthropogenic modifications of the environment during Bronze Age.


Assuntos
Arqueologia , Humanos , Europa (Continente) , Itália
2.
Br J Anaesth ; 120(6): 1202-1208, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29793587

RESUMO

BACKGROUND: In obese patients undergoing sleeve gastrectomy, the blood and fatty-tissue concentrations of cefazolin required for adequate antibiotic prophylaxis are uncertain. METHODS: This was a single centre prospective study in obese (Group A: 40≤ BMI ≤50 kg m-2) and severely obese (Group B: 50< BMI ≤65 kg m-2) patients undergoing bariatric surgery. Blood and fatty-tissue samples were collected after a cefazolin 4 g i.v. injection. The primary aim was to compare cefazolin concentrations in subcutaneous fatty tissue with a targeted tissue concentration of 4 µg g-1 according to Staphylococcus aureus resistance breakpoint. RESULTS: One hundred and sixteen patients were included: 79 in Group A and 37 in Group B. At the beginning of the surgery, cefazolin concentration in subcutaneous fatty tissue was 12.2 (5.4) µg g-1 in Group A and 12 (6.1) µg g-1 in Group B (P=0.7). At the end, cefazolin concentrations in subcutaneous fatty tissue were 9.0 (4.9) and 7.8 (4.2) µg g-1 in Groups A and B, respectively (P=0.2). The plasma concentration of free cefazolin during surgery was higher in Group A than in Group B (P<0.0001). Fatty-tissue concentrations of 95% and 83% patients in Groups A and B, respectively, were above S. aureus resistance breakpoint. CONCLUSIONS: After a 4 g dose, the concentrations of cefazolin in fatty tissue were above the 4 µg g-1 tissue concentration target, providing adequate antibiotic tissue concentrations during bariatric surgery. As cefazolin concentration in fatty tissue is a surrogate endpoint, the results should be considered in conjunction with the results on free cefazolin concentrations in subcutaneous tissue. CLINICAL TRIAL REGISTRATION: NCT01537380.


Assuntos
Antibacterianos/farmacocinética , Antibioticoprofilaxia/métodos , Cirurgia Bariátrica/métodos , Cefazolina/farmacocinética , Obesidade Mórbida/metabolismo , Infecção da Ferida Cirúrgica/prevenção & controle , Adulto , Antibacterianos/administração & dosagem , Antibacterianos/uso terapêutico , Índice de Massa Corporal , Cefazolina/administração & dosagem , Cefazolina/uso terapêutico , Esquema de Medicação , Feminino , Gastrectomia , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/cirurgia , Gordura Subcutânea/metabolismo
3.
Pathol Biol (Paris) ; 47(3): 266-8, 1999 Mar.
Artigo em Francês | MEDLINE | ID: mdl-10214620

RESUMO

Implantation of a device for long-term venous access is a simple procedure that can often be done under local anesthesia, with potentiation if needed. The implantation technique involves puncture of a large venous trunk and creation of a subcutaneous space in which the device can be lodged. Although complications are rare, patients should receive strict surveillance both during the immediate postoperative period and throughout use of the device.


Assuntos
Cateterismo Periférico/métodos , Cateteres de Demora , Cateterismo Periférico/efeitos adversos , Humanos
4.
Anesthesiology ; 70(4): 622-4, 1989 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-2929998

RESUMO

The authors evaluated the efficacy and incidence of side effects from blockade of the femoral nerve with 0.5% bupivacaine in 14 children with fracture of the middle third of the femoral shaft. In nine of these children, a pharmacokinetic analysis was also performed. The onset of analgesia occurred in 8.0 +/- 3.5 minutes after blockade of the femoral nerve. One block failed, resulting in iv narcotics being administered to alleviate the pain. In the remaining 13 children, pain decreased to nonexistent in 11 of the children and only mild pain with movement in the remaining two children. The level of analgesia did not change when the children underwent radiographic examination (60 +/- 18 min after the femoral nerve block) and application of traction (124 +/- 19 min after femoral nerve block). The maximum bupivacaine plasma concentration was 0.89 +/- 0.37 microgram/ml, obtained 24.4 +/- 12.6 min after the end of the injection. The femoral nerve blockade with bupivacaine provides prompt, effective, and prolonged analgesia in children suffering from fractures of the femoral shaft, allowing transport, radiographic examination, and application of traction in optimal conditions. Although the sample size was small, the side effects appeared to be rare.


Assuntos
Bupivacaína , Fraturas do Fêmur , Nervo Femoral , Bloqueio Nervoso , Bupivacaína/farmacocinética , Criança , Pré-Escolar , Humanos
7.
Am J Optom Physiol Opt ; 64(4): 256-62, 1987 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-3591896

RESUMO

An investigation into the stability of color appreciation after repeated testing with a light emitting diode (LED) system was undertaken. Experienced subjects viewed a LED simplon that had been set at a plateau intensity (in the photometric range), the principal variation being pulse duration (16 to 320 ms). A forced-choice color naming technique was applied. The investigation revealed a red shift for short duration exposures and an intense yellow shift for long exposures. Prolonged repeated testing produced a peculiar effect in the midrange: a loss of color, supplemented by a white effect, interpreted as a masking or tuning effect, by the achromatic channel.


Assuntos
Percepção de Cores , Testes Visuais , Adulto , Humanos , Pessoa de Meia-Idade , Estimulação Luminosa/métodos , Fatores de Tempo
9.
Ann Gastroenterol Hepatol (Paris) ; 21(3): 137-9, 1985 Jun.
Artigo em Francês | MEDLINE | ID: mdl-4026197

RESUMO

Spontaneous rupture of the spleen is a relatively rare occurrence during the course of chronic pancreatitis. The physiopathology remains imprecise and mechanical factors are associated with pancreatic enzyme diffusion and vascular changes in explaining its aetiology. The diagnosis is difficult since it often mimics an acute exacerbation of pancreatitis or even actual acute pancreatitis when the existence of the pancreatic condition is not previously known. Abdominal echotomography or peritoneal puncture-lavage and, now, CAT scanning are the key factors in reaching the diagnosis.


Assuntos
Pancreatite/complicações , Ruptura Esplênica/complicações , Adulto , Doença Crônica , Humanos , Masculino , Ruptura Espontânea , Ruptura Esplênica/diagnóstico
12.
Appl Opt ; 21(23): 4189-91, 1982 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-20401033
13.
Opt Lett ; 6(10): 478-80, 1981 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-19710743

RESUMO

The number of degrees of freedom of the field scattered by a spherical object is evaluated, in the Born approximation, by means of the eigenfunction technique.

14.
Ophthalmologica ; 176(6): 343-9, 1978.
Artigo em Inglês | MEDLINE | ID: mdl-692987

RESUMO

Electro-oculographic response is recorded from a number of normal subjects: one eye becomes adapted to light, while the contralateral one persists in its dark-adapted state. The viewing eye shows the expected light-induced amplification effect. The contralateral eye shows the expected "paradoxical' curve in 12 cases; in addition, a flat curve is found in 4 cases, and a curve running parallel to that recorded from the light-exposed eye is found in 8 cases. In agreement with a previous report, found in the literature, cortical bio-electrical activity (on-going EEG) also shows a light-induced amplification after the onset of an adapting field. This latter finding is once more confirmed by us. This fact, in conjunction with some recent psychophysical findings (Lansford and Baker effect) leads to infer that interocular EOG influences are mediated by other mechanisms, in addition to spread across facial tissues.


Assuntos
Eletroculografia , Fenômenos Fisiológicos Oculares , Potenciais de Ação , Adaptação à Escuridão , Eletroencefalografia , Lateralidade Funcional , Humanos
15.
Mod Probl Ophthalmol ; 19: 88-91, 1978.
Artigo em Inglês | MEDLINE | ID: mdl-723870

RESUMO

Nowadays, people are encouraged to utilize colour information. In turn, the sources employed for both indoor and outdoor installations show a variegated gamut of spectral distributions. The colour rendering factor refers to the average observer, representative of the normal, young, adult, healthy population. In order to have an idea of the deviations from this ideal case, we have been undertaking a population study. The results up-to-date obtained by the use of the high pressure Na source are now briefly reported.


Assuntos
Percepção de Cores/efeitos da radiação , Luz , Iluminação/métodos , Adulto , Fatores Etários , Carbono , Discriminação Psicológica , Humanos , Sódio
16.
Appl Opt ; 17(8): 1286-9, 1978 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-20197973

RESUMO

The effect of the detector nonlinearity on the statistics of a fluctuating signal is evaluated. The input signal is assumed to be log-normally distributed, which is of interest in the study of the laser propagation through the turbulent atmosphere. Both detector threshold and saturation effects are taken into account.

17.
Appl Opt ; 17(16): 2516-8, 1978 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-20203814

RESUMO

Approximate solutions of the wave equation are investigated, which can be considered as Gaussian beams affected by third-order spherical aberration. In practical cases, such beams are good approximations to the beams emerging from media whose square refractive index is described by a fourth-degree polynomial of the transverse coordinate. The measure of their spherical aberration could be a means for the determination of the coefficient of the fourth-order term in the expression of the square refractive index of the gradedindex medium.

18.
Appl Opt ; 17(18): 2869-71, 1978 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-20203887
19.
Med Res Eng ; 12(5): 20-4, 1977 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-613192

RESUMO

Changes in retinal potential take place when the eye is adequately stimulated. This evoked response, the electroretinogram (ERG) is recorded in vivo by placing an electrode on the cornea, while the reference electrode is grounded elsewhere. In spite of a great deal of work in this field, the very meaning of ERG, in the frame of visual process, is not yet wholly understood. The present paper produces some data which show that the plot of visual performance vs. time, during the course of the day, runs parallel to that of the size of ERG. The meaning of this finding is discussed, by making reference to the electrical analog of the recording circuit, in terms of lumping approximation.


Assuntos
Ritmo Circadiano , Retina/fisiologia , Adolescente , Adulto , Eletrorretinografia , Potenciais Evocados , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...