Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Magn Reson ; 311: 106666, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31846810

RESUMO

The transverse relaxation time (T2), measured with Carr-Purcell-Meiboom-Gill (CPMG) sequence, has been widely used to obtain the direct dimension data in two-dimension time domain NMR (2D TD-NMR). In this paper we are demonstrating that Continuous Wave Free Precession sequence, with low flip angle (CWFP-T1), can be an alternative to CPMG as direct detection dimension. CWFP-T1 is a fast single shot sequence, like CPMG, and yields an exponential signal governed predominantly by the longitudinal (T1) relaxation time. To obtain the correlations between T1 and T2 (T1-T2 maps) we are proposing the use of CPMG-CWFP-T1 pulse sequence. In this sequence CPMG encodes T2 information (indirect dimension) that modulates the CWFP-T1 (direct dimension) signal amplitudes. CPMG-CWFP-T1 experiments were compared with classical 2D sequences such as Saturation-Recovery-CPMG (SR-CPMG) and Inversion-Recovery-CPMG (IR-CPMG) sequence and yields similar results in phantom sample. The experimental time for the 2D sequences, using single scan, shows that SR-CPMG ≤ CPMG-CWFP-T1 < IR-CPMG. Experimental and simulated results demonstrated that 2D-CPMG-CWFP-T1 maps have higher resolution in T1 dimension than the techniques that uses CPMG as direct dimension. CPMG-CWFP-T1 sequence was also applied to study beef samples, and 2D maps showed higher resolution in the two fat signals than the classical IR-CPMG method.


Assuntos
Análise de Alimentos/métodos , Espectroscopia de Ressonância Magnética/métodos , Tecido Adiposo/química , Algoritmos , Animais , Bovinos , Simulação por Computador , Processamento Eletrônico de Dados , Carne/análise , Conformação Molecular , Razão Sinal-Ruído
2.
Magn Reson Chem ; 57(9): 616-625, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30443995

RESUMO

The traditional way to enhance signal-to-noise ratio (SNR) of nuclear magnetic resonance (NMR) signals is to increase the number of scans. However, this procedure increases the measuring time that can be prohibitive for some applications. Therefore, we have tested the use of several post-acquisition digital filters to enhance SNR up to one order of magnitude in time domain NMR (TD-NMR) relaxation measurements. The procedures were studied using continuous wave free precession (CWFP-T1 ) signals, acquired with very low flip angles that contain six times more noise than the Carr-Purcell-Meiboom-Gill (CPMG) signal of the same sample and experimental time. Linear (LI) and logarithmic (LO) data compression, low-pass infinity impulse response (LP), Savitzky-Golay (SG), and wavelet transform (WA) post-acquisition filters enhanced the SNR of the CWFP-T1 signals by at least six times. The best filters were LO, SG, and WA that have high enhancement in SNR without significant distortions in the ILT relaxation distribution data. Therefore, it was demonstrated that these post-acquisition digital filters could be a useful way to denoise CWFP-T1 , as well as CPMG noisy signals, and consequently reducing the experimental time. It was also demonstrated that filtered CWFP-T1 method has the potential to be a rapid and nondestructive method to measure fat content in beef and certainly in other meat samples.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA