Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ecotoxicol Environ Saf ; 172: 403-410, 2019 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-30735972

RESUMO

The present work reports the preparation of CO2-activated carbon (AC) using Stevia rebaudiana (Bertoni) residue as a new carbon precursor. The experimental parameters were optimized via chemometrics tools to obtain an AC with high BET surface area (SBET). The found optimum condition was: activation temperature of 900 °C, CO2 flow of 165 cm3 g-1 and activation time of 60 min, providing an ACop with SBET of 874 m2 g-1. The ACop was characterized from several analytical techniques, which showed that it has heterogeneous morphology features and different surface chemical groups, predominating the acidic character. The adsorption performance of ACop for triclosan (TCS) removal from solution was investigated by kinetic, equilibrium and thermodynamic studies. The results showed that TCS adsorption process onto ACop is spontaneous and endothermic, wherein the mechanism occurs by different steps, which equally play important roles. Additionally, the monolayer adsorption capacity (Qm) was found to be 117.00 mg g-1.


Assuntos
Dióxido de Carbono/química , Carvão Vegetal/química , Stevia/química , Triclosan/química , Adsorção , Carbono/química , Diterpenos do Tipo Caurano , Glucosídeos , Concentração de Íons de Hidrogênio , Cinética , Propriedades de Superfície , Temperatura , Termodinâmica
2.
Int J Anal Chem ; 2018: 1473706, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30402102

RESUMO

The present work reports the development and application of bismuth-film electrode (BiFE), obtained by in situ method on the pencil-lead graphite surface, for simultaneous Cd(II) and Pb(II) determination at trace levels, as alternative to replace the mercury-film electrodes. Experimental factors, deposition time (t d ), deposition potential (E d ), and Bi(III) concentration (C Bi ), were investigated by applying a 23 factorial design using 0.10 mol/L acetate buffer solution (pH 4.5) as supporting electrolyte. The analysis conditions of the differential pulse technique were t d = 250 s, E d = -1.40 V, and C Bi = 250 mg L-1. The validation of the method employing BiFE was accomplished by determination of merit figures. The detection limits were of 11.0 µg L-1 for Cd(II) and 11.5 µg L-1 for Pb(II), confirming that proposed method is attractive and suitable for heavy metals determination. Additionally, the BiFE developed was successfully applied for the Cd(II) and Pb(II) determination in wastewater sample of battery industry.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...