1.
J Phys Condens Matter ; 36(21)2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38364273

RESUMO

Passive solid-state radiation detectors, based on the visible photoluminescence (PL) of radiation-induced colour centres in optically transparent lithium fluoride (LiF), polycrystalline thin films are under investigation for proton beam advanced diagnostics. After proton exposure, the latent images stored in LiF as local formations of stable F2and F3+aggregate defects, are directly read with a fluorescence microscope under illumination in the blue spectral range. Adopting a suitable irradiation geometry, the energy density that protons deposit in the material can be recorded as a spatial distribution of these light-emitting defects, from which a luminous replica of the proton Bragg curve can be thereafter extracted and analysed to reconstruct the proton beam energy spectrum. Their peculiar properties, such as wide dynamic range and linearity of the spectrally-integrated PL response vs. dose, make the investigation of two-dimensional LiF film radiation detectors grown on several types of substrate highly attractive. Here, the case of a LiF thin film thermally evaporated on a silica substrate, irradiated at grazing incidence with a 35 MeV proton beam, is investigated and reported for the first time. A comparison of the measured photoluminescent Bragg curve with Monte Carlo simulations demonstrates that the Bragg peak in the film is located at the very same position that would be expected in the underlying silica substrate rather than in LiF. The film packing density is shown not to have a significant effect on the peak depth, while even small nonzero grazing angle of the impinging proton beam is able to significantly modify the shape of the Bragg curve. These findings are ascribed to the effects of multiple Coulomb scattering in both the film and the substrate and are interesting for proton beam diagnostics and dosimetry.

2.
Rev Sci Instrum ; 92(11): 113304, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34852547

RESUMO

In a medical accelerator, real-time monitoring systems of the beam and dose delivered to the patient are mandatory. In this work, we present a compact current profile detector that has been designed and tested in the framework of the TOP-IMPLART (Intensity Modulated Proton Linear Accelerator for RadioTerapy) project. This project foresees the realization of a proton linear accelerator, currently under construction at ENEA Frascati, for proton therapy applications. The linac produces a pulsed proton beam with 3 µs duration at 50 Hz repetition rate with a pulse current between 0.5 and 50 µA. A large dynamic range and spatial constraints make the use of usual noninterceptive beam diagnostics unfeasible. Therefore, the use of a beam current monitor based on a passive RF cavity working in the TM010 mode has been proposed. This paper reports the electromagnetic design of the device guided by a simplified analytical model. A prototype of such a device has been realized, characterized, and tested on the linac with a 35 MeV beam varying the beam current. The test results in air and in vacuum, together with the signal detection systems used, are presented.


Assuntos
Terapia com Prótons , Humanos , Aceleradores de Partículas , Prótons
3.
Radiat Prot Dosimetry ; 186(1): 113-118, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31141142

RESUMO

In the framework of the Italian TOP-IMPLART project (Regione Lazio), ENEA-Frascati, ISS and IFO are developing and constructing the first proton linear accelerator based on an actively scanned beam for tumor radiotherapy with final energy of 150 MeV. An important feature of this accelerator is modularity: an exploitable beam can be delivered at any stage of its construction, which allows for immediate characterization and virtually continuous improvement of its performance. Currently, a sequence of 3 GHz accelerating modules combined with a commercial injector operating at 425 MHz delivers protons up to 35 MeV. Several dosimetry systems were used to obtain preliminary characteristics of the 35-MeV beam in terms of stability and homogeneity. Short-term stability and homogeneity better than 3% and 2.6%, respectively, were demonstrated; for stability an improvement with respect to the respective value obtained for the previous 27 MeV beam.


Assuntos
Aceleradores de Partículas/instrumentação , Prótons , Radiometria/instrumentação , Radiometria/métodos , Desenho de Equipamento , Doses de Radiação
4.
Appl Radiat Isot ; 143: 35-40, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30368051

RESUMO

Development of non-destructive or micro-invasive scientific diagnostic techniques gained an outmost importance in the field of Cultural Heritage, contributing to assess authenticity, provenience and age of the objects, as well as supplying additional information to art conservators, to accomplish suitable restoring and preservative procedures. However, each diagnostic technique has its own advantages and limitations, thus in many cases the optimal sample characterization requires a synergy between different analytical approaches. In this context, Particle Induced X-ray Emission (PIXE) and high energy (HE) PIXE with 3 MeV and 17 MeV proton beams respectively, Elastic Backscattering Spectrometry (EBS) and micro X-Ray Fluorescence (µ-XRF) techniques were applied in a multi-analytical approach to characterize the composition of the artifacts. The analysed samples were four Roman Imperial coins belonging to different periods between 41 A.D. and 4 B.C. The employed Ion Beam Analysis (IBA) and XRF provided comparable quantitative results relative to the main sample elemental composition. The obtained results vary significantly from one coin to the other, depending on the production date and place, and on the conservation conditions.

5.
Rev Sci Instrum ; 89(3): 033302, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29604793

RESUMO

Plasma wakefield acceleration, either driven by ultra-short laser pulses or electron bunches, represents one of the most promising techniques able to overcome the limits of conventional RF technology and allows the development of compact accelerators. In the particle beam-driven scenario, ultra-short bunches with tiny spot sizes are required to enhance the accelerating gradient and preserve the emittance and energy spread of the accelerated bunch. To achieve such tight transverse beam sizes, a focusing system with short focal length is mandatory. Here we discuss the development of a compact and tunable system consisting of three small-bore permanent-magnet quadrupoles with 520 T/m field gradient. The device has been designed in view of the plasma acceleration experiments planned at the SPARC_LAB test-facility. Being the field gradient fixed, the focusing is adjusted by tuning the relative position of the three magnets with nanometer resolution. Details about its magnetic design, beam-dynamics simulations, and preliminary results are examined in the paper.

6.
Radiat Prot Dosimetry ; 180(1-4): 329-333, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29385620

RESUMO

The first proton linear accelerator for tumor therapy based on an actively scanned beam up to the energy of 150 MeV, is under development and construction by ENEA-Frascati, ISS and IFO, under the Italian TOP-IMPLART project. Protons up to the energy of 7 MeV are generated by a customized commercial injector operating at 425 MHz; currently three accelerating modules allow proton delivery with energy up to 27 MeV. Beam homogeneity and reproducibility were studied using a 2D ionizing chamber, EBT3 films, a silicon diode, MOSFETs, LiF crystals and alanine dosimetry systems. Measurements were taken in air with the detectors at ~1 m from the beam line exit window. The maximum energy impinging on the detectors surface was 24.1 MeV, an energy suitable for radiobiological studies. Results showed beam reproducibility within 5% and homogeneity within 4%, on a circular surface of 16 mm in diameter.


Assuntos
Dosimetria Fotográfica/instrumentação , Dosimetria Fotográfica/métodos , Aceleradores de Partículas/instrumentação , Prótons , Fluoretos/química , Transferência Linear de Energia , Compostos de Lítio/química , Silício/química
7.
Med Phys ; 42(8): 4678-84, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26233195

RESUMO

PURPOSE: To study EBT3 GafChromic film in low-energy protons, and for comparison purposes, in a reference (60)Co beam in order to use it as a calibrated dosimetry system in the proton irradiation facility under construction within the framework of the Oncological Therapy with Protons (TOP)-Intensity Modulated Proton Linear Accelerator for RadioTherapy (IMPLART) Project at ENEA-Frascati, Italy. METHODS: EBT3 film samples were irradiated at the Istituto Nazionale di Fisica Nucleare-Laboratori Nazionali di Legnaro, Italy, with a 5 MeV proton beam generated by a 7 MV Van de Graaff CN accelerator. The nominal dose rates used were 2.1 Gy/min and 40 Gy/min. The delivered dose was determined by measuring the particle fluence and the energy spectrum in air with silicon surface barrier detector monitors. A preliminary study of the EBT3 film beam quality dependence in low-energy protons was conducted by passively degrading the beam energy. EBT3 films were also irradiated at ENEA-National Institute of Ionizing Radiation Metrology with gamma radiation produced by a (60)Co source characterized by an absorbed dose to water rate of 0.26 Gy/min as measured by a calibrated Farmer type ionization chamber. EBT3 film calibration curves were determined by means of a set of 40 film pieces irradiated to various doses ranging from 0.5 Gy to 30 Gy absorbed dose to water. An EPSON Expression 11000XL color scanner in transmission mode was used for film analysis. Scanner response stability, intrafilm uniformity, and interfilm reproducibility were verified. Optical absorption spectra measurements were performed on unirradiated and irradiated EBT3 films to choose the most sensitive color channel to the dose range used. RESULTS: EBT3 GafChromic films show an under response up to about 33% for low-energy protons with respect to (60)Co gamma radiation, which is consistent with the linear energy transfer dependence already observed with higher energy protons, and a negligible dose-rate dependence in the 2-40 Gy/min range. Short- and long-term scanner stabilities were 0.5% and 1.5%, respectively; film uniformity and reproducibility were better than 0.5%. CONCLUSIONS: The main purpose of this study was to implement EBT3 dosimetry in the proton low-energy radiobiology line of the TOP-IMPLART accelerator, having a maximum energy of 7 MeV. Low-energy proton and (60)Co calibrated sources were used to investigate the behavior of film response vs to be written in italicum dose. The calibration in 5 MeV protons is currently used for dose assessment in the radiobiological experiments at the TOP-IMPLART accelerator carried out at that energy value.


Assuntos
Dosimetria Fotográfica/métodos , Ar , Calibragem , Radioisótopos de Cobalto/uso terapêutico , Dosimetria Fotográfica/instrumentação , Raios gama , Terapia com Prótons , Doses de Radiação , Radioterapia de Intensidade Modulada/instrumentação , Radioterapia de Intensidade Modulada/métodos , Silício , Água
8.
Rev Sci Instrum ; 86(7): 073301, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26233366

RESUMO

A pulsed, tunable, narrow band radiation source with frequency in the THz region can be obtained collecting the coherent transition radiation produced by a train of ultra-short electron bunches having picosecond scale inter-distance. In this paper, we review the techniques feasible at the SPARC_LAB test facility to produce and manipulate the requested train of electron bunches and we examine the dynamics of their acceleration and compression. In addition, we show how the performances of the train compression and the radiation intensity and bandwidth can be significantly improved through the insertion of a fourth order harmonic cavity, working in the X-band and acting as a longitudinal phase space linearizer.

9.
Phys Rev Lett ; 115(1): 014801, 2015 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-26182099

RESUMO

We present the experimental evidence of the generation of coherent and statistically stable two-color free-electron laser radiation obtained by seeding an electron beam double peaked in energy with a laser pulse single spiked in frequency. The radiation presents two neat spectral lines, with time delay, frequency separation, and relative intensity that can be accurately controlled. The analysis of the emitted radiation shows a temporal coherence and a shot-to-shot regularity in frequency significantly enhanced with respect to the self-amplified spontaneous emission.


Assuntos
Elétrons , Lasers , Cor , Simulação por Computador , Processamento de Imagem Assistida por Computador , Análise Espectral/instrumentação , Análise Espectral/métodos
10.
Phys Rev Lett ; 111(11): 114802, 2013 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-24074094

RESUMO

We present the experimental demonstration of a new scheme for the generation of ultrashort pulse trains based on free-electron-laser (FEL) emission from a multipeaked electron energy distribution. Two electron beamlets with energy difference larger than the FEL parameter ρ have been generated by illuminating the cathode with two ps-spaced laser pulses, followed by a rotation of the longitudinal phase space by velocity bunching in the linac. The resulting self-amplified spontaneous emission FEL radiation, measured through frequency-resolved optical gating diagnostics, reveals a double-peaked spectrum and a temporally modulated pulse structure.

11.
Rev Sci Instrum ; 84(2): 022703, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23464185

RESUMO

The linac driven coherent THz radiation source at the SPARC-LAB test facility is able to deliver broadband THz pulses with femtosecond shaping. In addition, high peak power, narrow spectral bandwidth THz radiation can be also generated, taking advantage of advanced electron beam manipulation techniques, able to generate an adjustable train of electron bunches with a sub-picosecond length and with sub-picosecond spacing. The paper reports on the manipulation, characterization, and transport of the electron beam in the bending line transporting the beam down to the THz station, where different coherent transition radiation spectra have been measured and studied with the aim to optimize the THz radiation performances.

12.
Phys Rev Lett ; 107(22): 224801, 2011 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-22182029

RESUMO

The injection of a seed in a free-electron laser (FEL) amplifier reduces the saturation length and improves the longitudinal coherence. A cascaded FEL, operating in the high-gain harmonic-generation regime, allows us to extend the beneficial effects of the seed to shorter wavelengths. We report on the first operation of a high-gain harmonic-generation free-electron laser, seeded with harmonics generated in gas. The third harmonics of a Ti:sapphire laser, generated in a gas cell, has been amplified and up-converted to its second harmonic (λ(rad)=133 nm) in a FEL cascaded configuration based on a variable number of modulators and radiators. We studied the transition between coherent harmonic generation and superradiant regime, optimizing the laser performances with respect to the number of modulators and radiators.

13.
Phys Rev Lett ; 106(14): 144801, 2011 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-21561195

RESUMO

We report the first experimental implementation of a method based on simultaneous use of an energy chirp in the electron beam and a tapered undulator, for the generation of ultrashort pulses in a self-amplified spontaneous emission mode free-electron laser (SASE FEL). The experiment, performed at the SPARC FEL test facility, demonstrates the possibility of compensating the nominally detrimental effect of the chirp by a proper taper of the undulator gaps. An increase of more than 1 order of magnitude in the pulse energy is observed in comparison to the untapered case, accompanied by FEL spectra where the typical SASE spiking is suppressed.

14.
Phys Rev Lett ; 104(5): 054801, 2010 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-20366769

RESUMO

In this Letter we report the first experiments aimed at the simultaneous demonstration of the emittance compensation process and velocity bunching in a high brightness electron source, the SPARC photoinjector in INFN-LNF. While a maximum compression ratio up to a factor 14 has been observed, in a particular case of interest a compression factor of 3, yielding a slice current of 120 A with less than 2 microm slice emittance, has been measured. This technique may be crucial in achieving high brightness beams in photoinjectors aiming at optimized performance of short wavelength single-pass free electron lasers or other advanced applications in laser-plasma accelerators.

15.
Rev Sci Instrum ; 79(1): 013303, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18248027

RESUMO

The design of photoinjectors for modern free electron laser linac relies heavily on particular beam behavior in the few meters after the gun. To experimentally characterize it a movable emittance meter was proposed and built [L. Catani et al., Rev. Sci. Instrum. 77, 093301 (2006)] based on the beam slicing technique. This paper addresses all the aspects of analysis of the data acquired with the emittance meter and common to any slit based emittance measurement for low energy beams.

16.
Phys Rev Lett ; 99(23): 234801, 2007 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-18233375

RESUMO

In this Letter we report the first experimental observation of the double emittance minimum effect in the beam dynamics of high-brightness electron beam generation by photoinjectors; this effect, as predicted by the theory, is crucial in achieving minimum emittance in photoinjectors aiming at producing electron beams for short wavelength single-pass free electron lasers. The experiment described in this Letter was performed at the SPARC photoinjector site, during the first stage of commissioning of the SPARC project. The experiment was made possible by a newly conceived device, called an emittance meter, which allows a detailed and unprecedented study of the emittance compensation process as the beam propagates along the beam pipe.