Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 89(10): 10K121, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399718

RESUMO

We present a device for controlled injection of a variety of materials in powder form. The system implements four independent feeder units, arranged to share a single vertical drop tube. Each unit consists of a 80 ml reservoir, coupled to a horizontal linear trough, where a layer of powder is advanced by piezo-electric agitation at a speed proportional to the applied voltage, until it falls into a drop tube. The dropper has been tested with a number of impurities of low (B, BN, C), intermediate (Si, SiC), and high Z (Sn) and a variety of microscopic structures (flakes, spheres, rocks) and sizes (5-200 µm). For low Z materials, drop rates ∼2-200 mg/s have been obtained showing good repeatability and uniformity. A calibrated light-emitting diode (LED)-based flowmeter allows measuring and monitoring the drop rate during operation. The fast time-response of the four feeders allows combination of steady and pulsed injections, providing a flexible tool for controlled-dose, real-time impurity injection in fusion plasmas.

2.
Rev Sci Instrum ; 85(11): 11E105, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430284

RESUMO

A new compact, multi-channel Solid State Neutral Particle Analyzer (SSNPA) diagnostic based on silicon photodiode array has been designed and is being fabricated for the National Spherical Torus Experiment-Upgrade (NSTX-U). The SSNPA system utilizes a set of vertically stacked photodiode arrays in current mode viewing the same plasma region with different filter thickness to obtain fast temporal resolution (∼120 kHz bandwidth) and coarse energy information in three bands of >25 keV, >45 keV, and >65 keV. The SSNPA system consists of 15 radial sightlines that intersect existing on-axis neutral beams at major radii between 90 and 130 cm, 15 tangential sightlines that intersect new off-axis neutral beams at major radii between 120 and 145 cm. These two subsystems aim at separating the response of passing and trapped fast ions. In addition, one photodiode array whose viewing area does not intersect any neutral beams is used to monitor passive signals produced by fast ions that charge exchange with background neutrals.

3.
Rev Sci Instrum ; 85(11): 11E821, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430386

RESUMO

Rutherford backscattering of energetic particles can be used to determine the thickness of a coating of a low-Z material over a heavier substrate. Simulations indicate that 5 MeV alpha particles from an (241)Am source can be used to measure the thickness of a Li coating on Mo tiles between 0.5 and 15 µm thick. Using a 0.1 mCi source, a thickness measurement can be accomplished in 2 h of counting. This technique could be used to measure any thin, low-Z material coating (up to 1 mg/cm(2) thick) on a high-Z substrate, such as Be on W, B on Mo, or Li on Mo. By inserting a source and detector on a moveable probe, this technique could be used to provide an in situ measurement of the thickness of Li coating on NSTX-U Mo tiles. A test stand with an alpha source and an annular solid-state detector was used to investigate the measurable range of low-Z material thicknesses on Mo tiles.

4.
Rev Sci Instrum ; 84(6): 063506, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23822344

RESUMO

With lithium as a fusion material gaining popularity, a method for producing lithium pellets relatively quickly has been developed for NSTX. The Lithium Pellet Production device is based on an injector with a sub-millimeter diameter orifice and relies on a jet of liquid lithium breaking apart into small spheres via the Plateau-Rayleigh instability. A prototype device is presented in this paper and for a pressure difference of ΔP = 5 Torr, spheres with diameters between 0.91 < D < 1.37 mm have been produced with an average diameter of D = 1.14 mm, which agrees with the developed theory. Successive tests performed at Princeton Plasma Physics Laboratory with Wood's metal have confirmed the dependence of sphere diameter on pressure difference as predicted.

5.
Rev Sci Instrum ; 83(10): 10D304, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126831

RESUMO

Solid state neutral particle analyzer (ssNPA) arrays are operated in current mode on the DIII-D tokamak and the National Spherical Torus Experiment (NSTX). Compared with conventional pulse-counting NPAs, current-mode operation sacrifices energy resolution to obtain economical, high-bandwidth, pitch-angle resolved measurements. With the success from a new three-channel near-vertical-view current mode ssNPA on DIII-D, the apertures on an existing array on NSTX were expanded to increase the particle influx. The sightlines of both arrays intersect heating beams, enabling both active and passive charge exchange measurements. The spatial resolution at beam intersection is typically 5 cm on both devices. Directly deposited ultra-thin foils on the detector surface block stray photons below the energy of 1 keV and also set low energy threshold about 25 keV for deuterium particle detection. Oscillations in neutral flux produced by high frequency magnetohydrodynamics (MHD) instabilities are readily detected.

6.
Rev Sci Instrum ; 83(10): 10D520, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126861

RESUMO

We report on upgrades to the flat-field grazing-incidence grating spectrometers X-ray and Extreme Ultraviolet Spectrometer (XEUS) and Long-Wavelength Extreme Ultraviolet Spectrometer (LoWEUS), at the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Laboratory. XEUS employs a variable space grating with an average spacing of 2400 lines/mm and covers the 9-64 Å wavelength band, while LoWEUS has an average spacing of 1200 lines/mm and is positioned to monitor the 90-270 Å wavelength band. Both spectrometers have been upgraded with new cameras that achieve 12.5 ms time resolution. We demonstrate the new time resolution capability by showing the time evolution of iron in the NSTX plasma.


Assuntos
Física/instrumentação , Espectrofotometria Ultravioleta/instrumentação , Elétrons , Gases em Plasma/química , Fatores de Tempo
7.
Rev Sci Instrum ; 83(10): 10D703, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126877

RESUMO

The objective of the materials analysis particle probe (MAPP) in NSTX is to enable prompt and direct analysis of plasma-facing components exposed to plasma discharges. MAPP allows multiple samples to be introduced to the level of the plasma-facing surface without breaking vacuum and analyzed using X-ray photoelectron spectroscopy (XPS), ion-scattering and direct recoil spectroscopy, and thermal desorption spectroscopy (TDS) immediately following the plasma discharge. MAPP is designed to operate as a diagnostic within the ∼12 min NSTX minimum between-shot time window to reveal fundamental plasma-surface interactions. Initial calibration demonstrates MAPP's XPS and TDS capabilities.

8.
Rev Sci Instrum ; 83(10): 10E532, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23127038

RESUMO

A pair of two dimensional fast cameras with a wide angle view (allowing a full radial and toroidal coverage of the lower divertor) was installed in the National Spherical Torus Experiment in order to monitor non-axisymmetric effects. A custom polar remapping procedure and an absolute photometric calibration enabled the easier visualization and quantitative analysis of non-axisymmetric plasma material interaction (e.g., strike point splitting due to application of 3D fields and effects of toroidally asymmetric plasma facing components).

9.
Rev Sci Instrum ; 83(8): 083506, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22938293

RESUMO

First results of ion and electron temperature profile measurements from the x-ray imaging crystal spectrometer (XICS) diagnostic on the Large Helical Device (LHD) are presented. This diagnostic system has been operational since the beginning of the 2011 LHD experimental campaign and is the first application of the XICS diagnostic technique to helical plasma geometry. The XICS diagnostic provides measurements of ion and electron temperature profiles in LHD with a spatial resolution of 2 cm and a maximum time resolution of 5 ms (typically 20 ms). Ion temperature profiles from the XICS diagnostic are possible under conditions where charge exchange recombination spectroscopy (CXRS) is not possible (high density) or is perturbative to the plasma (low density or radio frequency heated plasmas). Measurements are made by using a spherically bent crystal to provide a spectrally resolved 1D image of the plasma from line integrated emission of helium-like Ar(16 +). The final hardware design and configuration are detailed along with the calibration procedures. Line-integrated ion and electron temperature measurements are presented, and the measurement accuracy is discussed. Finally central temperature measurements from the XICS system are compared to measurements from the Thomson scattering and CXRS systems, showing excellent agreement.

10.
Rev Sci Instrum ; 83(5): 053706, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22667624

RESUMO

A novel imaging adaptor providing the capability to extend a standard single-band infrared (IR) camera into a two-color or dual-band device has been developed for application to high-speed IR thermography on the National Spherical Tokamak Experiment (NSTX). Temperature measurement with two-band infrared imaging has the advantage of being mostly independent of surface emissivity, which may vary significantly in the liquid lithium divertor installed on NSTX as compared to that of an all-carbon first wall. In order to take advantage of the high-speed capability of the existing IR camera at NSTX (1.6-6.2 kHz frame rate), a commercial visible-range optical splitter was extensively modified to operate in the medium wavelength and long wavelength IR. This two-band IR adapter utilizes a dichroic beamsplitter, which reflects 4-6 µm wavelengths and transmits 7-10 µm wavelength radiation, each with >95% efficiency and projects each IR channel image side-by-side on the camera's detector. Cutoff filters are used in each IR channel, and ZnSe imaging optics and mirrors optimized for broadband IR use are incorporated into the design. In-situ and ex-situ temperature calibration and preliminary data of the NSTX divertor during plasma discharges are presented, with contrasting results for dual-band vs. single-band IR operation.

11.
Rev Sci Instrum ; 82(5): 053502, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21639499

RESUMO

The ability to manage inventories of carbon, tritium, and high-Z elements in fusion plasmas depends on means for effective dust removal. A dust conveyor, based on a moving electrostatic potential well, was tested with particles of tungsten, carbon, glass, and sand. A digital microscope imaged a representative portion of the conveyor, and dust particle size and volume distributions were derived before and after operation. About 10 mm(3) volume of carbon and tungsten particles were moved in under 5 s. The highest driving amplitude tested of 3 kV was the most effective. The optimal driving frequency was 210 Hz (maximum tested) for tungsten particles, decreasing to below 60 Hz for the larger sand particles. Measurements of particle size and volume distributions after 10 and 100 cycles show the breaking apart of agglomerated carbon and the change in particle distribution over short timescales (<1 s).

12.
Rev Sci Instrum ; 82(3): 036102, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21456804

RESUMO

Local detection of surface dust is needed for the safe operation of next-step magnetic fusion devices such as ITER. An electrostatic dust detector, based on a grid of interlocking circuit traces biased to 50 V, has been developed to detect dust on remote surfaces and was successfully tested for the first time on the National Spherical Torus Experiment. In this note, we report a helium puff system that clears residual dust from this detector and any incident debris or fibers that might cause a permanent short circuit. Two consecutive helium puffs delivered by three 0.45 mm nozzles at an angle of 30° cleared the entire 5 cm × 5 cm surface of the detector.

13.
Rev Sci Instrum ; 81(10): 10D723, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033916

RESUMO

The use of lithium-coated plasma facing components for plasma density control is studied in the National Spherical Torus Experiment (NSTX). A recently installed liquid lithium divertor (LLD) module has a porous molybdenum surface, separated by a stainless steel liner from a heated copper substrate. Lithium is deposited on the LLD from two evaporators. Two new spectroscopic diagnostics are installed to study the plasma surface interactions on the LLD: (1) A 20-element absolute extreme ultraviolet (AXUV) diode array with a 6 nm bandpass filter centered at 121.6 nm (the Lyman-α transition) for spatially resolved divertor recycling rate measurements in the highly reflective LLD environment, and (2) an ultraviolet-visible-near infrared R=0.67 m imaging Czerny-Turner spectrometer for spatially resolved divertor D I, Li I-II, C I-IV, Mo I, D(2), LiD, CD emission and ion temperature on and around the LLD module. The use of photometrically calibrated measurements together with atomic physics factors enables studies of recycling and impurity particle fluxes as functions of LLD temperature, ion flux, and divertor geometry.

14.
Rev Sci Instrum ; 81(10): 10D917, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033949

RESUMO

The recent availability of broadband microwave quadrature mixers in the Ka-band (28-40 GHz) of frequencies has allowed the fabrication of low-cost direct-conversion detection circuits for use in the variable-frequency correlation reflectometer on the National Spherical Torus eXperiment (NSTX). The quadrature receiver in this case can be implemented as a simple homodyne circuit, without the complication of a single-sideband modulator or a feedforward tracking circuit present in more typical designs. A pair of direct-conversion receivers is coupled with broadband microwave voltage-controlled oscillators to construct a flexible dual-channel radar system with a fast frequency settling time of ∼160 µs. A detailed description of the design and a full characterization of the hardware are provided. Examples of turbulence measurements from radial and poloidal correlation reflectometry on NSTX using a poloidal array of antennas (oriented normal to the magnetic flux surfaces for conventional reflectometry) are presented.

15.
Rev Sci Instrum ; 81(10): 10E102, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033967

RESUMO

The first real-time detection of surface dust inside a tokamak was made using an electrostatic dust detector. A fine grid of interlocking circuit traces was installed in the NSTX vessel and biased to 50 V. Impinging dust particles created a temporary short circuit and the resulting current pulse was recorded by counting electronics. The techniques used to increase the detector sensitivity by a factor of ×10,000 to match NSTX dust levels while suppressing electrical pickup are presented. The results were validated by comparison to laboratory measurements, by the null signal from a covered detector that was only sensitive to pickup, and by the dramatic increase in signal when Li particles were introduced for wall conditioning purposes.

16.
Rev Sci Instrum ; 81(10): 10E326, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034024

RESUMO

Tungsten particles have been introduced into the National Spherical Torus Experiment (NSTX) in Princeton with the purpose to investigate the effects of tungsten injection on subsequent plasma discharges. An experimental setup for the study of tungsten particle transport is described where the particles are introduced into the tokamak using a modified particle dropper, otherwise used for lithium-powder injection. An initial test employing a grazing-incidence extreme ultraviolet spectrometer demonstrates that the tungsten-transport setup could serve to infer particle transport from the edge to the hot central plasmas of NSTX.

17.
Rev Sci Instrum ; 81(10): 10E328, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034026

RESUMO

A high-resolution x-ray imaging crystal spectrometer, whose concept was tested on NSTX and Alcator C-Mod, is being designed for the large helical device (LHD). This instrument will record spatially resolved spectra of helium-like Ar(16+) and will provide ion temperature profiles with spatial and temporal resolutions of <2 cm and ≥10 ms, respectively. The spectrometer layout and instrumental features are largely determined by the magnetic field structure of LHD. The stellarator equilibrium reconstruction codes, STELLOPT and PIES, will be used for the tomographic inversion of the spectral data.

18.
Rev Sci Instrum ; 81(2): 023501, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192490

RESUMO

A new high speed infrared camera has been successfully implemented and produced first set of heat flux measurements on the lower divertor tiles in the NSTX tokamak. High spatial and temporal resolutions, 6.4 mm and 1.6-6.3 kHz, respectively, enable us to investigate detailed structure of heat flux deposition pattern caused by transient events such as edge localized modes. A comparison of the data with a slow infrared camera viewing the same region of interest shows good agreement between the two independent measurements. Data analysis for various plasma conditions is in progress.

19.
Rev Sci Instrum ; 79(10): 10F124, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044608

RESUMO

A linear array of four small biased electrodes was installed in NSTX in an attempt to control the width of the scrape-off layer by creating a strong local poloidal electric field. The set of electrodes was separated poloidally by a 1 cm gap between electrodes and were located slightly below the midplane of NSTX, 1 cm behind the rf antenna, and oriented so that each electrode is facing approximately normal to the magnetic field. Each electrode can be independently biased to +/-100 V. Present power supplies limit the current on two electrodes to 30 A and the other two to 10 A each. The effect of local biasing was measured with a set of Langmuir probes placed between the electrodes and another set extending radially outward from the electrodes, and also by the gas puff imaging diagnostic located 1 m away along the magnetic field lines intersecting the electrodes. Two fast cameras were also aimed directly at the electrode array. The hardware and controls of the biasing experiment will be presented and the initial effects on local plasma parameters will be discussed.

20.
Rev Sci Instrum ; 79(10): 10F303, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044616

RESUMO

Dust production and accumulation present potential safety and operational issues for the ITER. Dust diagnostics can be divided into two groups: diagnostics of dust on surfaces and diagnostics of dust in plasma. Diagnostics from both groups are employed in contemporary tokamaks; new diagnostics suitable for ITER are also being developed and tested. Dust accumulation in ITER is likely to occur in hidden areas, e.g., between tiles and under divertor baffles. A novel electrostatic dust detector for monitoring dust in these regions has been developed and tested at PPPL. In the DIII-D tokamak dust diagnostics include Mie scattering from Nd:YAG lasers, visible imaging, and spectroscopy. Laser scattering is able to resolve particles between 0.16 and 1.6 microm in diameter; using these data the total dust content in the edge plasmas and trends in the dust production rates within this size range have been established. Individual dust particles are observed by visible imaging using fast framing cameras, detecting dust particles of a few microns in diameter and larger. Dust velocities and trajectories can be determined in two-dimension with a single camera or three-dimension using multiple cameras, but determination of particle size is challenging. In order to calibrate diagnostics and benchmark dust dynamics modeling, precharacterized carbon dust has been injected into the lower divertor of DIII-D. Injected dust is seen by cameras, and spectroscopic diagnostics observe an increase in carbon line (CI, CII, C(2) dimer) and thermal continuum emissions from the injected dust. The latter observation can be used in the design of novel dust survey diagnostics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...