Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 91(8): 085112, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32872913

RESUMO

The Trace Vapor Generator for Explosives and Narcotics (TV-Gen) is a portable and compact instrument designed to deliver a continuous source of trace-level vapors and vapor mixtures. It provides a tool to assist in the independent validation and verification of new materials and sensors under development for the vapor detection of explosives and narcotics. The design was conceived for use with a broad range of analytes, detection systems, materials, and sensors and to switch easily between the clean and analyte vapor streams. The TV-Gen system utilizes nebulization of aqueous analyte solutions, an oven to promote efficient transport, and a control box that provides dedicated computer control with logging capabilities. Resultant vapor streams are stable over several hours, with the vapor concentration controlled by a combination of aqueous analyte solution concentration, liquid flow rate through the nebulizer, and volume flow rate of air through the TV-Gen manifold.

2.
Rev Sci Instrum ; 88(3): 034104, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28372430

RESUMO

A novel vapor delivery testbed, referred to as the Trace Explosives Sensor Testbed, or TESTbed, is demonstrated that is amenable to both high- and low-volatility explosives vapors including nitromethane, nitroglycerine, ethylene glycol dinitrate, triacetone triperoxide, 2,4,6-trinitrotoluene, pentaerythritol tetranitrate, and hexahydro-1,3,5-trinitro-1,3,5-triazine. The TESTbed incorporates a six-port dual-line manifold system allowing for rapid actuation between a dedicated clean air source and a trace explosives vapor source. Explosives and explosives-related vapors can be sourced through a number of means including gas cylinders, permeation tube ovens, dynamic headspace chambers, and a Pneumatically Modulated Liquid Delivery System coupled to a perfluoroalkoxy total-consumption microflow nebulizer. Key features of the TESTbed include continuous and pulseless control of trace vapor concentrations with wide dynamic range of concentration generation, six sampling ports with reproducible vapor profile outputs, limited low-volatility explosives adsorption to the manifold surface, temperature and humidity control of the vapor stream, and a graphical user interface for system operation and testing protocol implementation.

3.
J Chromatogr A ; 1451: 83-90, 2016 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-27207576

RESUMO

Hexamethylene triperoxide diamine (HMTD) is an easily synthesized and highly sensitive organic peroxide frequently used as a primary explosive. The vapor pressure of HMTD is very low, impeding vapor detection, especially when compared to other peroxide explosives, such as triacetone triperoxide (TATP) or diacetone diperoxide (DADP). Despite this fact, HMTD has a perceptible odor that could be utilized in the indirect detection of HMTD vapor. Headspace measurements above solid HMTD samples confirm that HMTD readily decomposes under ambient conditions to form highly volatile products that include formic acid, ammonia, trimethylamine and formamides. The presence and quantity of these compounds are affected by storage condition, time, and synthetic method, with synthetic method having the most significant effect on the content of the headspace. A kinetic study of HMTD decomposition in solution indicated a correlation between degradation rate and the presence of decomposition species identified in the headspace, and provided further insight into the mechanism of decomposition. The study provided evidence for a proton assisted decomposition reaction with water, as well as an intramolecular decomposition process facilitated by the presence of water.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes/análise , Compostos Bicíclicos Heterocíclicos com Pontes/química , Substâncias Explosivas/análise , Substâncias Explosivas/química , Prótons , Água/química , Amônia/análise , Armazenamento de Medicamentos , Formamidas/análise , Formiatos/análise , Cinética , Metilaminas/análise , Fatores de Tempo , Pressão de Vapor , Volatilização
4.
Artigo em Inglês | MEDLINE | ID: mdl-26132346

RESUMO

Chemical detection in complex environments presents numerous challenges for successful implementation. Arrays of sensors are often implemented for complex chemical sensing tasks, but systematic understanding of how individual sensor response characteristics contribute overall detection system performance remains elusive, with generalized strategies for design and optimization of these arrays rarely reported and even less commonly adopted by practitioners. This review focuses on the literature of nonspecific sensor array design and optimization strategies as well as related work that may inform future efforts in complex sensing with arrays.

5.
J Vis Exp ; (89): e51938, 2014 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-25145416

RESUMO

The direct liquid deposition of solution standards onto sorbent-filled thermal desorption tubes is used for the quantitative analysis of trace explosive vapor samples. The direct liquid deposition method yields a higher fidelity between the analysis of vapor samples and the analysis of solution standards than using separate injection methods for vapors and solutions, i.e., samples collected on vapor collection tubes and standards prepared in solution vials. Additionally, the method can account for instrumentation losses, which makes it ideal for minimizing variability and quantitative trace chemical detection. Gas chromatography with an electron capture detector is an instrumentation configuration sensitive to nitro-energetics, such as TNT and RDX, due to their relatively high electron affinity. However, vapor quantitation of these compounds is difficult without viable vapor standards. Thus, we eliminate the requirement for vapor standards by combining the sensitivity of the instrumentation with a direct liquid deposition protocol to analyze trace explosive vapor samples.


Assuntos
Cromatografia Gasosa/métodos , Substâncias Explosivas/análise , Triazinas/análise , Trinitrotolueno/análise , Substâncias Explosivas/química , Triazinas/química , Trinitrotolueno/química , Volatilização
6.
J Chromatogr A ; 1227: 10-8, 2012 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-22265176

RESUMO

The use of thermal desorption systems for the analysis of trace vapors typically requires establishing a calibration curve from vapors generated with a permeation tube. The slow equilibration time of permeation tubes causes such an approach to become laborious when covering a wide dynamic range. Furthermore, many analytes of interest, such as explosives, are not available as permeation tubes. A method for easily and effectively establishing calibration curves for explosive vapor samples via direct deposition of standard solutions on thermal desorption tubes was investigated. The various components of the thermal desorption system were compared to a standard split/splitless inlet. Calibration curves using the direct liquid deposition method with a thermal desorption unit coupled to a cryo-focusing inlet were compared to a standard split/splitless inlet, and a statistical difference was observed but does not eliminate or deter the use of the direct liquid deposition method for obtaining quantitative results for explosive vapors.


Assuntos
Substâncias Explosivas/análise , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Cromatografia Gasosa-Espectrometria de Massas/métodos , Gases/química , Trinitrotolueno/análise , Calibragem , Substâncias Explosivas/isolamento & purificação , Reprodutibilidade dos Testes , Temperatura , Trinitrotolueno/isolamento & purificação
7.
Anal Chim Acta ; 584(1): 78-88, 2007 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-17386588

RESUMO

Electrochemical sensors composed of a ceramic-metallic (cermet) solid electrolyte are used for the detection of gaseous sulfur compounds SO(2), H(2)S, and CS(2) in a study involving 11 toxic industrial chemical (TIC) compounds. The study examines a sensor array containing four cermet sensors varying in electrode-electrolyte composition, designed to offer selectivity for multiple compounds. The sensors are driven by cyclic voltammetry to produce a current-voltage profile for each analyte. Raw voltammograms are processed by background subtraction of clean air, and the four sensor signals are concatenated to form one vector of points. The high-resolution signal is compressed by wavelet transformation and a probabilistic neural network is used for classification. In this study, training data from one sensor array was used to formulate models which were validated with data from a second sensor array. Of the 11 gases studied, 3 that contained sulfur produced the strongest responses and were successfully analyzed when the remaining compounds were treated as interferents. Analytes were measured from 10 to 200% of their threshold-limited value (TLV) according to the 8-h time weighted average (TWA) exposure limits defined by the National Institute of Occupational Safety and Health (NIOSH). True positive classification rates of 93.3, 96.7, and 76.7% for SO(2), H(2)S, and CS(2), respectively, were achieved for prediction of one sensor unit when a second sensor was used for modeling. True positive rates of 83.3, 90.0, and 90.0% for SO(2), H(2)S, and CS(2), respectively, were achieved for the second sensor unit when the first sensor unit was used for modeling. Most of the misclassifications were for low concentration levels (such 10-25% TLV) in which case the compound was classified as clean air. Between the two sensors, the false positive rates were 2.2% or lower for the three sulfur compounds, 0.9% or lower for the interferents (eight remaining analytes), and 5.8% or lower for clean air. The cermet sensor arrays used in this analysis are rugged, low cost, reusable, and show promise for multiple compound detection at parts-per-million (ppm) levels.


Assuntos
Cimentos Cermet , Gases/análise , Compostos de Enxofre/análise , Amônia/análise , Dissulfeto de Carbono/análise , Monóxido de Carbono/análise , Eletroquímica/métodos , Eletrólitos , Gases/classificação , Sulfeto de Hidrogênio/análise , Técnicas de Sonda Molecular , Compostos de Enxofre/classificação , Dióxido de Enxofre/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...