Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Nucl Med Technol ; 40(3): 187-93, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22872664

RESUMO

UNLABELLED: A high radiochemical purity (RCP) is recommended for radiopharmaceutical compounds used in the clinical practice of nuclear medicine. However, some preparations of (99m)Tc-sestamibi contain excess impurities (>6%). To understand the origin of these impurities, we investigated the effect of sodium nitrate on the RCP of sestamibi preparations by testing eluates from 3 commercially available (99m)Tc generators. METHODS: The sestamibi kits (Stamicis) were reconstituted with (99m)Tc eluate from nitrate-containing wet-column (NCWC), nitrate-free wet-column (NFWC), and nitrate-free dry-column (NFDC) generators. Sodium nitrate was 0.05 mg/mL in eluates from the NCWC generators. The RCP was determined using aluminum oxide sheets as the stationary phase and absolute ethanol as the mobile phase. Succimer, tetrofosmin, oxidronate, exametazine, albumin nanocolloid, and soluble albumin were also tested for their RCP values with eluates from the 3 different (99m)Tc generators. RESULTS: The RCP assessment of (99m)Tc-sestamibi was performed on 127 Stamicis preparations. Significantly lower RCP values were found for Stamicis kits prepared with the NCWC generator than for Stamicis prepared with the NFWC (P < 0.0001) and NFDC (P < 0.0001) generators. The number of Stamicis preparations with an RCP under 94% was greater with the NCWC generator (32 of 53 kits) than with the NFDC (2 of 51 kits) or NFWC (0 of 23 kits) generator. Furthermore, the addition of a 0.05 mg/mL concentration of nitrate in NFWC generator eluates significantly decreased the RCP of the Stamicis preparation. In the absence of nitrate in (99m)Tc eluate, no difference was observed between the RCP values of Stamicis kits prepared with the NFWC and NFDC generators. The (99m)Tc impurities generated by nitrates did not modify the quality of myocardial imaging (normal heart-to-lung ratio, 2.2), probably because these impurities are not in the heart field of view. No other tested (99m)Tc-radiopharmaceutical interfered with nitrates. CONCLUSION: We recommend using nitrate-free generator eluates in (99m)Tc-sestamibi preparations to improve the product quality and prevent unnecessary exposure of the patient to radiation.


Assuntos
Composição de Medicamentos/métodos , Nitratos/análise , Radioquímica , Tecnécio Tc 99m Sestamibi/química , Imagem de Perfusão do Miocárdio
2.
Acta Cardiol ; 63(3): 401-4, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18664034

RESUMO

The occurrence of a coronary spasm after an adenosine stress test is an exceptional event. We report a vasospasm in a patient with normal coronary angiography. The spasm occurred shortly after termination of adenosine infusion on abrupt withdrawal of vasodilation. Ischaemia induced ventricular arrhythmia (bursts of polymorphous tachycardia) that responded well to antispastic therapy. The main identified predisposing factor for coronary spasm was vasospastic angina and adenosine acted as a revealing factor of this unsuspected diagnosis.


Assuntos
Adenosina/efeitos adversos , Dor no Peito/diagnóstico , Vasoespasmo Coronário/induzido quimicamente , Vasodilatadores/efeitos adversos , Angiografia Coronária , Vasoespasmo Coronário/diagnóstico , Vasoespasmo Coronário/fisiopatologia , Diagnóstico Diferencial , Eletrocardiografia , Teste de Esforço/efeitos adversos , Teste de Esforço/métodos , Feminino , Humanos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...