1.
J Appl Clin Med Phys ; 19(2): 265-274, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29322614

RESUMO

The purpose of the present study was to test an idea of and describe a concept of a novel method of detecting defects related to horizontal nonuniformities in ultrasound equipment. The method is based on the analysis of ultrasound images collected directly from the clinical workflow. In total over 31000 images from three ultrasound scanners from two vendors were collected retrospectively from a database. An algorithm was developed and applied to the images, 150 at a time, for detection of systematic dark regions in the superficial part of the images. The result was compared with electrical measurements (FirstCall) of the transducers, performed at times when the transducers were known to be defective. The algorithm made similar detection of horizontal nonuniformities for images acquired at different time points over long periods of time. The results showed good subjective visual agreement with the available electrical measurements of the defective transducers, indicating a potential use of clinical images for early and automatic detection of defective transducers, as a complement to quality control.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias/diagnóstico por imagem , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/normas , Transdutores/normas , Ultrassonografia/normas , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Controle de Qualidade
2.
J Appl Clin Med Phys ; 17(6): 366-378, 2016 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-27929509

RESUMO

The purpose of the present study was to evaluate the relevance of using a phantom to simulate a clinical situation where small low contrast objects are embedded in relatively homogeneous organs in order to discriminate between different ultrasound machines, taking into account human observer variability. One high-end and one general ultrasound machine using the same probe were included. Images containing 4 and 6.4-mm objects of four different contrasts were collected from a greyscale phantom at different depths. Six observers participated in a 4-alternative forced choice study based on 960 images. Variability was determined using bootstrapping. At four of sixteen depth/size/contrast combinations, the visual performance of the high-end machine was significantly higher. The results indicate that it is possible to use a greyscale phantom to discriminate between ultrasound machines in terms of their ability to reproduce clinically relevant low-contrast objects. However, the number of images and number of observers needed are larger than those usually used for constancy control, if the large uncertainties caused by human observer variability is to be taken correctly into account.


Assuntos
Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/instrumentação , Ultrassonografia/métodos , Algoritmos , Humanos , Variações Dependentes do Observador , Doses de Radiação , Razão Sinal-Ruído