Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Biomed Eng ; 68(7): 2313-2325, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33784612

RESUMO

OBJECTIVE: Individuals with neurological disease or injury such as amyotrophic lateral sclerosis, spinal cord injury or stroke may become tetraplegic, unable to speak or even locked-in. For people with these conditions, current assistive technologies are often ineffective. Brain-computer interfaces are being developed to enhance independence and restore communication in the absence of physical movement. Over the past decade, individuals with tetraplegia have achieved rapid on-screen typing and point-and-click control of tablet apps using intracortical brain-computer interfaces (iBCIs) that decode intended arm and hand movements from neural signals recorded by implanted microelectrode arrays. However, cables used to convey neural signals from the brain tether participants to amplifiers and decoding computers and require expert oversight, severely limiting when and where iBCIs could be available for use. Here, we demonstrate the first human use of a wireless broadband iBCI. METHODS: Based on a prototype system previously used in pre-clinical research, we replaced the external cables of a 192-electrode iBCI with wireless transmitters and achieved high-resolution recording and decoding of broadband field potentials and spiking activity from people with paralysis. Two participants in an ongoing pilot clinical trial completed on-screen item selection tasks to assess iBCI-enabled cursor control. RESULTS: Communication bitrates were equivalent between cabled and wireless configurations. Participants also used the wireless iBCI to control a standard commercial tablet computer to browse the web and use several mobile applications. Within-day comparison of cabled and wireless interfaces evaluated bit error rate, packet loss, and the recovery of spike rates and spike waveforms from the recorded neural signals. In a representative use case, the wireless system recorded intracortical signals from two arrays in one participant continuously through a 24-hour period at home. SIGNIFICANCE: Wireless multi-electrode recording of broadband neural signals over extended periods introduces a valuable tool for human neuroscience research and is an important step toward practical deployment of iBCI technology for independent use by individuals with paralysis. On-demand access to high-performance iBCI technology in the home promises to enhance independence and restore communication and mobility for individuals with severe motor impairment.


Assuntos
Interfaces Cérebro-Computador , Encéfalo , Mãos , Humanos , Microeletrodos , Quadriplegia
2.
Neuron ; 84(6): 1170-82, 2014 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-25482026

RESUMO

Brain recordings in large animal models and humans typically rely on a tethered connection, which has restricted the spectrum of accessible experimental and clinical applications. To overcome this limitation, we have engineered a compact, lightweight, high data rate wireless neurosensor capable of recording the full spectrum of electrophysiological signals from the cortex of mobile subjects. The wireless communication system exploits a spatially distributed network of synchronized receivers that is scalable to hundreds of channels and vast environments. To demonstrate the versatility of our wireless neurosensor, we monitored cortical neuron populations in freely behaving nonhuman primates during natural locomotion and sleep-wake transitions in ecologically equivalent settings. The interface is electrically safe and compatible with the majority of existing neural probes, which may support previously inaccessible experimental and clinical research.


Assuntos
Eletrodos Implantados , Eletrofisiologia/instrumentação , Telemetria/instrumentação , Animais , Córtex Cerebral/fisiologia , Eletrofisiologia/métodos , Macaca mulatta , Masculino , Neurônios/fisiologia , Sono/fisiologia , Telemetria/métodos , Vigília/fisiologia , Caminhada/fisiologia
3.
Eur Spine J ; 21(8): 1660-73, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22407270

RESUMO

PURPOSE: To gain insight into a new technology, a novel facet arthroplasty device (TFAS) was compared to a rigid posterior fixation system (UCR). The axial and bending loads through the implants and at the bone-implant interfaces were evaluated using an ex vivo biomechanical study and matched finite element analysis. Kinematic behaviour has been reported for TFAS, but implant loads have not. Implant loads are important indicators of an implant's performance and safety. The rigid posterior fixation system is used for comparison due to the extensive information available about these systems. METHODS: Unconstrained pure moments were applied to 13 L3-S1 cadaveric spine segments. Specimens were tested intact, following decompression, UCR fixation and TFAS implantation at L4-L5. UCR fixation was via standard pedicle screws and TFAS implantation was via PMMA-cemented transpedicular stems. Three-dimensional 10 Nm moments and a 600 N follower load were applied; L4-L5 disc pressures and implant loads were measured using a pressure sensor and strain gauges, respectively. A finite element model was used to calculate TFAS bone-implant interface loads. RESULTS: UCR experienced greater implant loads in extension (p < 0.004) and lateral bending (p < 0.02). Under flexion, TFAS was subject to greater implant moments (p < 0.04). At the bone-implant interface, flexion resulted in the smallest TFAS (average = 0.20 Nm) but greatest UCR (1.18 Nm) moment and axial rotation resulted in the greatest TFAS (3.10 Nm) and smallest UCR (0.40 Nm) moments. Disc pressures were similar to intact for TFAS but not for UCR (p < 0.04). CONCLUSIONS: These results are most applicable to the immediate post-operative period prior to remodelling of the bone-implant interface since the UCR and TFAS implants are intended for different service lives (UCR--until fusion, TFAS--indefinitely). TFAS reproduced intact-like anterior column load-sharing--as measured by disc pressure. The highest bone-implant moment of 3.1 Nm was measured in TFAS and for the same loading condition the UCR interface moment was considerably lower (0.4 Nm). For other loading conditions, the differences between TFAS and UCR were smaller, with the UCR sometimes having larger values and for others the TFAS was larger. The long-term physiological meaning of these findings is unknown and demonstrates the need for a better understanding of the relationship between spinal arthroplasty devices and the host tissue as development of next generation motion-preserving posterior devices that hope to more accurately replicate the natural functions of the native tissue continues.


Assuntos
Artroplastia de Substituição/instrumentação , Vértebras Lombares/cirurgia , Articulação Zigapofisária/cirurgia , Artroplastia de Substituição/métodos , Fenômenos Biomecânicos/fisiologia , Humanos , Próteses e Implantes , Amplitude de Movimento Articular/fisiologia , Rotação , Suporte de Carga
4.
Spine J ; 9(1): 96-102, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-18440280

RESUMO

BACKGROUND CONTEXT: Lumbar fusion is traditionally used to restore stability after wide surgical decompression for spinal stenosis. The Total Facet Arthroplasty System (TFAS) is a motion-restoring implant suggested as an alternative to rigid fixation after complete facetectomy. PURPOSE: To investigate the effect of TFAS on the kinematics of the implanted and adjacent lumbar segments. STUDY DESIGN: Biomechanical in vitro study. METHODS: Nine human lumbar spines (L1 to sacrum) were tested in flexion-extension (+8 to -6Nm), lateral bending (+/-6Nm), and axial rotation (+/-5Nm). Flexion-extension was tested under 400 N follower preload. Specimens were tested intact, after complete L3 laminectomy with L3-L4 facetectomy, after L3-L4 pedicle screw fixation, and after L3-L4 TFAS implantation. Range of motion (ROM) was assessed in all tested directions. Neutral zone and stiffness in flexion and extension were calculated to assess quality of motion. RESULTS: Complete laminectomy-facetectomy increased L3-L4 ROM compared with intact in flexion-extension (8.7+/-2.0 degrees to 12.2+/-3.2 degrees, p<.05) lateral bending (9.0+/-2.5 degrees to 12.6+/-3.2 degrees, p=.09), and axial rotation (3.8+/-2.7 degrees to 7.8+/-4.5 degrees p<.05). Pedicle screw fixation decreased ROM compared with intact, resulting in 1.7+/-0.5 degrees flexion-extension (p<.05), 3.3+/-1.4 degrees lateral bending (p<.05), and 1.8+/-0.6 degrees axial rotation (p=.09). TFAS restored intact ROM (p>.05) resulting in 7.9+/-2.1 degrees flexion-extension, 10.1+/-3.0 degrees lateral bending, and 4.7+/-1.6 degrees axial rotation. Fusion significantly increased the normalized ROM at all remaining lumbar segments, whereas TFAS implantation resulted in near-normal distribution of normalized ROM at the implanted and remaining lumbar segments. Flexion and extension stiffness in the high-flexibility zone decreased after facetectomy (p<.05) and increased after simulated fusion (p<.05). TFAS restored quality of motion parameters (load-displacement curves) to intact (p>.05). The quality of motion parameters for the whole lumbar spine mimicked L3-L4 segmental results. CONCLUSIONS: TFAS restored range and quality of motion at the operated segment to intact values and restored near-normal motion at the adjacent segments.


Assuntos
Artroplastia de Substituição/instrumentação , Fenômenos Biomecânicos/fisiologia , Laminectomia/instrumentação , Amplitude de Movimento Articular/fisiologia , Coluna Vertebral/cirurgia , Artroplastia de Substituição/métodos , Feminino , Humanos , Laminectomia/métodos , Vértebras Lombares , Masculino , Pessoa de Meia-Idade
5.
SAS J ; 3(2): 50-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-25802628

RESUMO

BACKGROUND: Facet arthroplasty is a motion restoring procedure. It is normally suggested as an alternative to rigid fixation after destabilizing decompression procedures in the posterior lumbar spine. While previous studies have reported successful results in reproducing normal spine kinematics after facet replacement at L4-5 and L3-4, there are no data on the viability of facet replacement at the lumbosacral joint. The anatomy of posterior elements and the resulting kinematics at L5-S1 are distinctly different from those at superior levels, making the task of facet replacement at the lumbosacral level challenging. This study evaluated the kinematics of facet replacement at L5-S1. METHODS: Six human cadaveric lumbar spines (L1-S1, 46.7 ± 13.0 years) were tested in the following sequence: (1) intact (L1-S1), (2) complete laminectomy and bilateral facetectomy at L5-S1, and (3) implantation of TFAS-LS (Lumbosacral Total Facet Arthroplasty System, Archus Orthopedics, Redmond, Washington) at L5-S1 using pedicle screws. Specimens were tested in flexion (8Nm), extension (6Nm), lateral bending (LB, ± 6Nm), and axial rotation (AR, ± 5Nm). The level of significance was α = .017 after Bonferroni correction for three comparisons: (1) intact vs. destabilized, (2) destabilized vs. reconstructed, and (3) intact vs. reconstructed. RESULTS: Laminectomy-facetectomy at L5-S1 increased the L5-S1 angular range of motion (ROM) in all directions. Flexion-extension (F-E) ROM increased from 15.3 ± 2.9 to 18.7 ± 3.5 degrees (P < .017), LB from 8.2 ± 1.8 to 9.3 ± 1.6 degrees (P < .017), and AR from 3.7 ± 2.0 to 5.9 ± 1.8 degrees (P < .017). The facet arthroplasty system decreased ROM compared to the laminectomy-facetectomy condition in all tested directions (P < .017). The facet arthroplasty system restored the L5-S1 ROM to its intact levels in LB and AR (P > .017). F-E ROM after the facet arthroplasty system implantation was smaller than the intact value (10.1 ± 2.2 vs. 15.3 ± 2.9 degrees, P < .017). The load-displacement curves after the facet arthroplasty system implantation at L5-S1 were sigmoidal, and quality of motion measures were similar to intact, demonstrating graded resistance to angular motion in F-E, LB and AR. CONCLUSIONS: The facet arthroplasty system was able to restore stability to the lumbosacral segment after complete laminectomy and bilateral facetectomy, while also allowing near-normal kinematics in all planes. While F-E ROM after the facet arthroplasty system implantation was smaller than the intact value, it was within the physiologic norms for L5-S1. These results are consistent with previous studies of facet arthroplasty at L3-L4 and L4-L5 and demonstrate that TFAS technology can be adapted to the lumbosacral joint with functionality comparable to its application in superior lumbar levels.

6.
SAS J ; 3(3): 85-90, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-25802631

RESUMO

BACKGROUND: Total disc replacement (TDR) and total facet replacement (TFR) have been the focus of recent kinematics evaluations. Yet their concurrent function as a total joint replacement of the lumbar spine's 3-joint complex has not been comprehensively reported. This study evaluated the effect of a TFR specifically designed to replace the natural facets and supplement the function with the natural disc and with TDR. The ability to replace degenerated facets to complement a pre-existing or simultaneously implanted TDR may allow surgeons to completely address degenerative pathologies of the 3-joint complex of the lumbar spine. We hypothesized that TFR would reproduce the biomechanical function of the natural facets when implanted in conjunction with TDR. METHODS: Lumbar spines (L1-5, 51.3 ± 14.2 years, N = 6) were tested sequentially as follows: (1) intact, (2) after TDR implantation, and (3) after TFR implantation in conjunction with TDR, all at L3-4. Specimens were tested in flexion-extension (+ 8 Nm to - 6 Nm), lateral bending (± 6 Nm), and axial rotation (± 5 Nm). A 400 N compressive follower preload was applied during flexion-extension tests. Three-dimensional segmental motion was recorded and analyzed using analysis of variance in Systat (Systat Software Inc., Chicago, Illinois) and multiple comparisons with Bonferroni correction. RESULTS: The TDR implantation (TDR + natural facets) allowed similar lateral bending (P = .66), but it generally increased flexion-extension (P = .06) and axial rotation (P < .05) range of motion (ROM) at the implanted level compared to intact. The TFR + TDR (following replacement of the natural facets with TFR) decreased ROM to levels similar to intact in lateral bending (P = .70) and axial rotation (P = .23). The TFR + TDR flexion-extension ROM was reduced in comparison to intact and TDR + natural facets (P < .05). CONCLUSIONS: The TFR with TDR was able to restore stability to the lumbar segment after bilateral facetectomy, while allowing near-normal motions in all planes.

7.
Spine (Phila Pa 1976) ; 32(1): 55-62, 2007 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-17202893

RESUMO

STUDY DESIGN: An in vitro biomechanical study to quantify 3-dimensional kinematics of the lumbar spine following facet arthroplasty. OBJECTIVES: To compare the multidirectional flexibility properties and helical axis of motion of the Total Facet Arthroplasty System (TFAS) (Archus Orthopedics, Redmond, WA) to the intact condition and to posterior pedicle screw fixation. SUMMARY OF BACKGROUND DATA: Facet arthroplasty in the lumbar spine is a new concept in the field of spinal surgery. The kinematic behavior of any complete facet arthroplasty device in the lumbar spine has not been reported previously. METHODS: Flexibility tests were conducted on 13 cadaveric specimens in an intact and injury model, and after stabilization with the TFAS and posterior pedicle screw fixation at the L4-L5 level. A pure moment of +/-10 Nm with a compressive follower preload of 600 N was applied to the specimen in flexion-extension, axial rotation, and lateral bending. Range of motion (ROM), neutral zone, and helical axis of motion were calculated for the L4-L5 segment. RESULTS: ROM with the TFAS was 81% of intact in flexion (P = 0.035), 68% in extension (P = 0.079), 88% in lateral bending (P = 0.042), and 128% in axial rotation (P = 0.013). The only significant change in neutral zone with TFAS compared to the intact was an increase in axial rotation (P = 0.011). The only significant difference in helical axis of motion location or orientation between the TFAS and intact condition was an anterior shift of the helical axis of motion in axial rotation (P = 0.013). CONCLUSIONS: The TFAS allowed considerable motion in all directions tested, with ROM being less than the intact in flexion and lateral bending, and greater than the intact in axial rotation. The helical axis of motion with the TFAS was not different from intact in flexion-extension and lateral bending, but it was shifted anteriorly in axial rotation. The kinematics of the TFAS were more similar to the intact spine than were the kinematics of the posterior fixation when applied to a destabilized lumbar spine.


Assuntos
Artroplastia de Substituição/instrumentação , Artroplastia de Substituição/métodos , Vértebras Lombares/fisiologia , Adulto , Idoso , Fenômenos Biomecânicos/instrumentação , Fenômenos Biomecânicos/métodos , Feminino , Humanos , Fixadores Internos , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...