1.
Rev Sci Instrum ; 93(11): 113301, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461450

RESUMO

In this work, the first proof of the principal of an in situ diagnostics of the heavy-ion beam intensity distribution in irradiation of solid targets is proposed. In this scheme, x-ray fluorescence that occurs in the interaction of heavy-ions with target atoms is used for imaging purposes. The x-ray conversion to optical radiation and a transport-system was developed, and its first test was performed in experiments at the Universal Linear Accelerator in Darmstadt, Germany. The Au-beam intensity distribution on thin foils and Cu-mesh targets was imaged using multiple x-ray pinholes (polychromatic imaging) and 2D monochromatic imaging of Cu Kα radiation by using a toroidally bent silicon crystal. The presented results are of importance for application in experiments on the investigation of the equation of states of high energy density matter using high intensity GeV/u heavy-ion beams of ≥1010 particles/100 ns.

2.
Nat Commun ; 13(1): 170, 2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35013380

RESUMO

Ultra-intense MeV photon and neutron beams are indispensable tools in many research fields such as nuclear, atomic and material science as well as in medical and biophysical applications. For applications in laboratory nuclear astrophysics, neutron fluxes in excess of 1021 n/(cm2 s) are required. Such ultra-high fluxes are unattainable with existing conventional reactor- and accelerator-based facilities. Currently discussed concepts for generating high-flux neutron beams are based on ultra-high power multi-petawatt lasers operating around 1023 W/cm2 intensities. Here, we present an efficient concept for generating γ and neutron beams based on enhanced production of direct laser-accelerated electrons in relativistic laser interactions with a long-scale near critical density plasma at 1019 W/cm2 intensity. Experimental insights in the laser-driven generation of ultra-intense, well-directed multi-MeV beams of photons more than 1012 ph/sr and an ultra-high intense neutron source with greater than 6 × 1010 neutrons per shot are presented. More than 1.4% laser-to-gamma conversion efficiency above 10 MeV and 0.05% laser-to-neutron conversion efficiency were recorded, already at moderate relativistic laser intensities and ps pulse duration. This approach promises a strong boost of the diagnostic potential of existing kJ PW laser systems used for Inertial Confinement Fusion (ICF) research.

3.
Opt Express ; 29(8): 12240-12251, 2021 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-33984988

RESUMO

In a recent experimental campaign, we used laser-accelerated relativistic hot electrons to ensure heating of thin titanium wire targets up to a warm dense matter (WDM) state [EPL114, 45002 (2016)10.1209/0295-5075/114/45002]. The WDM temperature profiles along several hundred microns of the wire were inferred by using spatially resolved X-ray emission spectroscopy looking at the Ti Kα characteristic lines. A maximum temperature of ∼30 eV was reached. Our study extends this work by discussing the influence of the laser parameters on temperature profiles and the optimisation of WDM wire-based generation. The depth of wire heating may reach several hundreds of microns and it is proven to be strictly dependent on the laser intensity. At the same time, it is quantitatively demonstrated that the maximum WDM temperature doesn't appear to be sensitive to the laser intensity and mainly depends on the deposited laser energy considering ranges of 6×1018-6×1020 W/cm2 and 50-200 J.

4.
Opt Lett ; 43(16): 3909-3912, 2018 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-30106914

RESUMO

One order of magnitude energy enhancement of the target surface electron beams with central energy at 11.5 MeV is achieved by using a 200 TW, 500 fs laser at an incident angle of 72° with a prepulse intensity ratio of 5×10-6. The experimental results demonstrate the scalability of the acceleration process to high electron energy with a longer (sub-picosecond) laser pulse duration and a higher laser energy (120 J). The total charge of the beam is 400±20 pC(E>2.7 MeV). Such a high orientation and mono-energetic electron jet would be a good method to solve the problem of the large beam divergence in fast ignition schemes and to increase the laser energy deposition on the target core.

5.
Phys Rev Lett ; 119(20): 204801, 2017 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-29219328

RESUMO

A novel method to determine the total hydrogen density and, accordingly, a precise plasma temperature in a lowly ionized hydrogen plasma is described. The key to the method is to analyze the energy loss of swift heavy ions interacting with the respective bound and free electrons of the plasma. A slowly developing and lowly ionized hydrogen theta-pinch plasma is prepared. A Boltzmann plot of the hydrogen Balmer series and the Stark broadening of the H_{ß} line preliminarily defines the plasma with a free electron density of (1.9±0.1)×10^{16} cm^{-3} and a free electron temperature of 0.8-1.3 eV. The temperature uncertainty results in a wide hydrogen density, ranging from 2.3×10^{16} to 7.8×10^{18} cm^{-3}. A 108 MHz pulsed beam of ^{48}Ca^{10+} with a velocity of 3.652 MeV/u is used as a probe to measure the total energy loss of the beam ions. Subtracting the calculated energy loss due to free electrons, the energy loss due to bound electrons is obtained, which linearly depends on the bound electron density. The total hydrogen density is thus determined as (1.9±0.7)×10^{17} cm^{-3}, and the free electron temperature can be precisely derived as 1.01±0.04 eV. This method should prove useful in many studies, e.g., inertial confinement fusion or warm dense matter.

6.
Nat Commun ; 5: 4158, 2014 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-24938756

RESUMO

Stimulated Raman backscattering (SRS) has many unwanted effects in megajoule-scale inertially confined fusion (ICF) plasmas. Moreover, attempts to harness SRS to amplify short laser pulses through backward Raman amplification have achieved limited success. In high-temperature fusion plasmas, SRS usually occurs in a kinetic regime where the nonlinear response of the Langmuir wave to the laser drive and its host of complicating factors make it difficult to predict the degree of amplification that can be achieved under given experimental conditions. Here we present experimental evidence of reduced Landau damping with increasing Langmuir wave amplitude and determine its effects on Raman amplification. The threshold for trapping effects to influence the amplification is shown to be very low. Above threshold, the complex SRS dynamics results in increased amplification factors, which partly explains previous ICF experiments. These insights could aid the development of more efficient backward Raman amplification schemes in this regime.

7.
Phys Rev Lett ; 111(23): 235006, 2013 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-24476284

RESUMO

An experimental program was designed to study the most important issues of laser-plasma interaction physics in the context of the shock ignition scheme. In the new experiments presented in this Letter, a combination of kilojoule and short laser pulses was used to study the laser-plasma coupling at high laser intensities for a large range of electron densities and plasma profiles. We find that the backscatter is dominated by stimulated Brillouin scattering with stimulated Raman scattering staying at a limited level. This is in agreement with past experiments using long pulses but laser intensities limited to 2×10(15) W/cm2, or short pulses with intensities up to 5×10(16) W/cm2 as well as with 2D particle-in-cell simulations.

8.
Rev Sci Instrum ; 81(10): 10E312, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034011

RESUMO

Soft x-ray emission from a Mather-type plasma-focus device (PF-1000) operated at ∼400 kJ was measured. The high density and temperature plasma were generated by the discharge in the deuterium-argon gas mixture in the modified (high-current) plasma-focus configuration. A spherically bent mica crystal spectrograph viewing the axial output of the pinch region was used to measure the x-ray spectra. Spatially resolved spectra including the characteristic x-ray lines of highly ionized Ar and continua were recorded by means of an x-ray film. The x-ray emission of PF-1000 device was studied at different areas of the pinch.