Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 149
Filtrar
1.
Science ; 385(6712): 954-961, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39208112

RESUMO

Recent respiratory outbreaks have garnered substantial attention, yet most respiratory monitoring remains confined to physical signals. Exhaled breath condensate (EBC) harbors rich molecular information that could unveil diverse insights into an individual's health. Unfortunately, challenges related to sample collection and the lack of on-site analytical tools impede the widespread adoption of EBC analysis. Here, we introduce EBCare, a mask-based device for real-time in situ monitoring of EBC biomarkers. Using a tandem cooling strategy, automated microfluidics, highly selective electrochemical biosensors, and a wireless reading circuit, EBCare enables continuous multimodal monitoring of EBC analytes across real-life indoor and outdoor activities. We validated EBCare's usability in assessing metabolic conditions and respiratory airway inflammation in healthy participants, patients with chronic obstructive pulmonary disease or asthma, and patients after COVID-19 infection.


Assuntos
Testes Respiratórios , Expiração , Máscaras , Humanos , Asma/diagnóstico , Biomarcadores/análise , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Testes Respiratórios/métodos , Testes Respiratórios/instrumentação , COVID-19/diagnóstico , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Manejo de Espécimes/métodos , Manejo de Espécimes/instrumentação , Doenças Respiratórias
2.
Artigo em Inglês | MEDLINE | ID: mdl-39205640

RESUMO

Quantitating exercise ventilatory and gas exchange dynamics affords insights into physiological control processes and cardiopulmonary dysfunction. We designed a novel waveform, the chirp waveform, to efficiently extract moderate intensity exercise response dynamics. In the chirp waveform, work rate fluctuates sinusoidally with constant amplitude as sinusoidal period decreases progressively from approximately 8.5 to 1.4 minutes over 30 minutes of cycle ergometry. We hypothesized that response dynamics of pulmonary ventilation (V̇E) and gas exchange (V̇O2 and V̇CO2) extracted from chirp waveform are similar to those obtained from step-wise transitions. Thirty-one participants (14 young-healthy, 7 older-healthy, 10 COPD patients) exercised on three occasions. Participants first performed ramp-incremental exercise for gas exchange threshold (GET) determination. In randomized order, the next two visits involved either chirp or step-wise waveforms. Work rate amplitude (20W to ∼95% GET work rate) and exercise duration (30 min) were the same for both waveforms. A first-order linear transfer function with system gain (G) and time constant (τ) characterized response dynamics. Agreement between model parameters extracted from chirp and step-wise waveforms was established using Bland-Altman analysis and Rothery's Concordance Coefficient (RCC). V̇E, V̇O2, and V̇CO2 Gs showed no systematic bias (p>0.178) and moderate-to-good agreement (RCC>0.772, p<0.01) between waveforms. Similarly, no systematic bias (p=0.815) and good agreement (RCC=0.837, p<0.001) was found for τV̇O2. Despite moderate agreement for τV̇CO2 (RCC=0.794, p<0.001) and τV̇E (RCC=0.722, p=0.083), chirp τ was less (-6.9(11.7)s and -12.2(22.5)s, respectively). We conclude that the chirp waveform is a promising method for measuring exercise response dynamics and investigating physiological control mechanisms.

3.
J Cachexia Sarcopenia Muscle ; 15(3): 1016-1029, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38649783

RESUMO

BACKGROUND: Skeletal muscle dysfunction is a common extrapulmonary manifestation of chronic obstructive pulmonary disease (COPD). Alterations in skeletal muscle myosin heavy chain expression, with reduced type I and increased type II myosin heavy chain expression, are associated with COPD severity when studied in largely male cohorts. The objectives of this study were (1) to define an abnormal myofibre proportion phenotype in both males and females with COPD and (2) to identify transcripts and transcriptional networks associated with abnormal myofibre proportion in COPD. METHODS: Forty-six participants with COPD were assessed for body composition, strength, endurance and pulmonary function. Skeletal muscle biopsies from the vastus lateralis were assayed for fibre-type distribution and cross-sectional area via immunofluorescence microscopy and RNA-sequenced to generate transcriptome-wide gene expression data. Sex-stratified k-means clustering of type I and IIx/IIax fibre proportions was used to define abnormal myofibre proportion in participants with COPD and contrasted with previously defined criteria. Single transcripts and weighted co-expression network analysis modules were tested for correlation with the abnormal myofibre proportion phenotype. RESULTS: Abnormal myofibre proportion was defined in males with COPD (n = 29) as <18% type I and/or >22% type IIx/IIax fibres and in females with COPD (n = 17) as <36% type I and/or >12% type IIx/IIax fibres. Half of the participants with COPD were classified as having an abnormal myofibre proportion. Participants with COPD and an abnormal myofibre proportion had lower median handgrip strength (26.1 vs. 34.0 kg, P = 0.022), 6-min walk distance (300 vs. 353 m, P = 0.039) and forced expiratory volume in 1 s-to-forced vital capacity ratio (0.42 vs. 0.48, P = 0.041) compared with participants with COPD and normal myofibre proportions. Twenty-nine transcripts were associated with abnormal myofibre proportions in participants with COPD, with the upregulated NEB, TPM1 and TPM2 genes having the largest fold differences. Co-expression network analysis revealed that two transcript modules were significantly positively associated with the presence of abnormal myofibre proportions. One of these co-expression modules contained genes classically associated with muscle atrophy, as well as transcripts associated with both type I and type II myofibres, and was enriched for genetic loci associated with bone mineral density. CONCLUSIONS: Our findings indicate that there are significant transcriptional alterations associated with abnormal myofibre proportions in participants with COPD. Transcripts canonically associated with both type I and type IIa fibres were enriched in a co-expression network associated with abnormal myofibre proportion, suggesting altered transcriptional regulation across multiple fibre types.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Humanos , Doença Pulmonar Obstrutiva Crônica/genética , Doença Pulmonar Obstrutiva Crônica/metabolismo , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Fibras Musculares Esqueléticas/metabolismo , Fibras Musculares Esqueléticas/patologia , Músculo Esquelético/patologia , Músculo Esquelético/metabolismo , Transcriptoma , Perfilação da Expressão Gênica
5.
Med Sci Sports Exerc ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38465870

RESUMO

INTRODUCTION: Traditional neuromuscular fatigue assessments are not task-specific and are unable to characterize neuromuscular performance decline during dynamic whole-body exercise. This study used interleaved maximal isokinetic cycling efforts to characterize the dynamics of the decline in neuromuscular performance during ramp-incremental (RI) cycle ergometry exercise to intolerance. METHODS: Eleven young healthy participants (10 male/1 female) performed two RI cycle ergometry exercise tests to intolerance: [1] RI-exercise with peak isokinetic power (Piso) at 80 rev·min-1 measured at baseline and immediately at intolerance from a maximal ~6 s effort; [2] RI-exercise where additional Piso measurements were interleaved every 90 s to characterize the decline in neuromuscular performance during the RI-test. Muscle excitation was measured using EMG during all Piso assessments, and pulmonary gas exchange was measured throughout. RESULTS: Baseline Piso was 832 ± 140 W and RI-exercise reduced Piso to 349 ± 96 W at intolerance (p = 0.001), which was not different from flywheel power at intolerance (303 ± 96 W; p = 0.292). There was no reduction in Piso between baseline cycling and gas exchange threshold (GET; baseline Piso vs. mean Piso below GET: 828 ± 146 vs. 815 ± 149 W; p = 1.00). Piso fell progressively above GET until intolerance (Piso every 90 s above GET: 759 ± 139; 684 ± 141; 535 ± 144; 374 ± 117 W; each p < 0.05 vs. baseline and mean Piso below GET). Peak muscle excitation (EMG) was also reduced only above GET (73 ± 14 % of baseline, at intolerance; p < 0.05). However, the reduction in peak Piso preceded the reduction in peak muscle excitation. CONCLUSIONS: The dynamics of the decline in neuromuscular performance (reduction in Piso and EMG) during RI-exercise are consistent with known intensity-dependent metabolic and traditional pre-post neuromuscular fatigue responses to discrete bouts of constant-power exercise.

7.
Eur J Appl Physiol ; 124(3): 1027-1036, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37803179

RESUMO

PURPOSE: Pathogen transmission during cardio-pulmonary exercise testing (CPET) is caused by carrier aerosols generated during respiration. METHODS: Ten healthy volunteers (age range: 34 ± 15; 4 females) were recruited to see if the physiological reactions to ramp-incremental CPET on a cycle ergometer were affected using an in-line filter placed between the mouthpiece and the flow sensor. The tests were in random order with or without an in-line bacterial/viral spirometer filter. The work rate aligned, time interpolated 10 s bin data were compared throughout the exercise period. RESULTS: From rest to peak exercise, filter use increased only minute ventilation ([Formula: see text]E) (Δ[Formula: see text]E = 1.56 ± 0.70 L/min, P < 0.001) and tidal volume (VT) (ΔVT = 0.10 ± 0.11 L, P = 0.014). Over the entire test, the slope of the residuals for [Formula: see text]CO2 was positive (0.035 ± 0.041 (ΔL/L), P = 0.027). During a ramp-incremental CPET in healthy subjects, an in-line filter increased [Formula: see text]E and VT but not metabolic rate. CONCLUSION: In conclusion, using an in-line filter is feasible, does not affect appreciably the physiological variables, and may mitigate risk of aerosol dispersion during CPET.


Assuntos
Teste de Esforço , Respiração , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Voluntários Saudáveis , Exercício Físico/fisiologia , Volume de Ventilação Pulmonar , Consumo de Oxigênio/fisiologia
8.
Exp Physiol ; 109(3): 322-323, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38156673

Assuntos
Oxigênio
9.
Ann Am Thorac Soc ; 21(5): 727-739, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38109693

RESUMO

Rationale: A COPD Foundation working group sought to identify measures of exercise endurance, a meaningful aspect of physical functioning in everyday life among patients with chronic obstructive pulmonary disease (COPD) that is not fully accepted in regulatory decision making, hampering drug development. Objectives: To demonstrate, as we previously asserted (Casaburi COPD 2022;9:252), that constant work rate cycling endurance time is an appropriate exercise endurance measure in patients with COPD. Methods: To validate this assertion, we assembled an integrated database of endurance time responses, including 8 bronchodilator (2,166 subjects) and 15 exercise training (3,488 subjects) studies (Casaburi COPD 2022;9:520). Results: Construct validity was demonstrated: 1) peak physiologic and perceptual responses were similar for constant work rate and incremental cycling; 2) after bronchodilator therapy, there were greater increases in endurance time in patients with more severe airflow limitation; 3) after exercise training, endurance time increases were similar across airflow limitation severities; and 4) there were correlations between changes in endurance time and changes in mechanistically related physiologic and perceptual variables. Test-retest reliability was demonstrated, with consistency of changes in endurance time at two time points after the intervention. Responsiveness was confirmed, with significant increases in endurance time after active (but not placebo) bronchodilator therapy, with greater increases seen with more severe airflow limitation and after exercise training. On the basis of regression analysis using multiple anchor variables, the minimum important difference for endurance time increase is estimated to be approximately 1 minute. Conclusions: Constant work rate cycling endurance time is a valid exercise endurance measure in COPD, suitable for contributing to the evaluation of treatment benefit supporting regulatory decision making and evidence-based therapeutic recommendations.


Assuntos
Broncodilatadores , Resistência Física , Doença Pulmonar Obstrutiva Crônica , Humanos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/terapia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Broncodilatadores/uso terapêutico , Reprodutibilidade dos Testes , Teste de Esforço/métodos , Tolerância ao Exercício/fisiologia , Volume Expiratório Forçado , Ensaios Clínicos como Assunto , Terapia por Exercício/métodos
10.
Semin Respir Crit Care Med ; 44(5): 661-680, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37429332

RESUMO

Aerobic, or endurance, exercise is an energy requiring process supported primarily by energy from oxidative adenosine triphosphate synthesis. The consumption of oxygen and production of carbon dioxide in muscle cells are dynamically linked to oxygen uptake (V̇O2) and carbon dioxide output (V̇CO2) at the lung by integrated functions of cardiovascular, pulmonary, hematologic, and neurohumoral systems. Maximum oxygen uptake (V̇O2max) is the standard expression of aerobic capacity and a predictor of outcomes in diverse populations. While commonly limited in young fit individuals by the capacity to deliver oxygen to exercising muscle, (V̇O2max) may become limited by impairment within any of the multiple systems supporting cellular or atmospheric gas exchange. In the range of available power outputs, endurance exercise can be partitioned into different intensity domains representing distinct metabolic profiles and tolerances for sustained activity. Estimates of both V̇O2max and the lactate threshold, which marks the upper limit of moderate-intensity exercise, can be determined from measures of gas exchange from respired breath during whole-body exercise. Cardiopulmonary exercise testing (CPET) includes measurement of V̇O2 and V̇CO2 along with heart rate and other variables reflecting cardiac and pulmonary responses to exercise. Clinical CPET is conducted for persons with known medical conditions to quantify impairment, contribute to prognostic assessments, and help discriminate among proximal causes of symptoms or limitations for an individual. CPET is also conducted in persons without known disease as part of the diagnostic evaluation of unexplained symptoms. Although CPET quantifies a limited sample of the complex functions and interactions underlying exercise performance, both its specific and global findings are uniquely valuable. Some specific findings can aid in individualized diagnosis and treatment decisions. At the same time, CPET provides a holistic summary of an individual's exercise function, including effects not only of the primary diagnosis, but also of secondary and coexisting conditions.

11.
Am J Physiol Regul Integr Comp Physiol ; 325(5): R433-R445, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37519253

RESUMO

Identification of the breathing cycle forms the basis of any breath-by-breath gas exchange analysis. Classically, the breathing cycle is defined as the time interval between the beginning of two consecutive inspiration phases. Based on this definition, several research groups have developed algorithms designed to estimate the volume and rate of gas transferred across the alveolar membrane ("alveolar gas exchange"); however, most algorithms require measurement of lung volume at the beginning of the ith breath (VLi-1; i.e., the end-expiratory lung volume of the preceding ith breath). The main limitation of these algorithms is that direct measurement of VLi-1 is challenging and often unavailable. Two solutions avoid the requirement to measure VLi-1 by redefining the breathing cycle. One method defines the breathing cycle as the time between two equal fractional concentrations of lung expired oxygen (Fo2) (or carbon dioxide; Fco2), typically in the alveolar phase, whereas the other uses the time between equal values of the Fo2/Fn2 (or Fco2/Fn2) ratios [i.e., the ratio of fractional concentrations of lung expired O2 (or CO2) and nitrogen (N2)]. Thus, these methods identify the breathing cycle by analyzing the gas fraction traces rather than the gas flow signal. In this review, we define the traditional approach and two alternative definitions of the human breathing cycle and present the rationale for redefining this term. We also explore the strengths and limitations of the available approaches and provide implications for future studies.


Assuntos
Alvéolos Pulmonares , Troca Gasosa Pulmonar , Humanos , Troca Gasosa Pulmonar/fisiologia , Alvéolos Pulmonares/fisiologia , Respiração , Pulmão/fisiologia , Testes Respiratórios , Dióxido de Carbono , Oxigênio
12.
Nat Biomed Eng ; 7(10): 1293-1306, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37349389

RESUMO

The quantification of protein biomarkers in blood at picomolar-level sensitivity requires labour-intensive incubation and washing steps. Sensing proteins in sweat, which would allow for point-of-care monitoring, is hindered by the typically large interpersonal and intrapersonal variations in its composition. Here we report the design and performance of a wearable and wireless patch for the real-time electrochemical detection of the inflammatory biomarker C-reactive (CRP) protein in sweat. The device integrates iontophoretic sweat extraction, microfluidic channels for sweat sampling and for reagent routing and replacement, and a graphene-based sensor array for quantifying CRP (via an electrode functionalized with anti-CRP capture antibodies-conjugated gold nanoparticles), ionic strength, pH and temperature for the real-time calibration of the CRP sensor. In patients with chronic obstructive pulmonary disease, with active or past infections or who had heart failure, the elevated concentrations of CRP measured via the patch correlated well with the protein's levels in serum. Wearable biosensors for the real-time sensitive analysis of inflammatory proteins in sweat may facilitate the management of chronic diseases.


Assuntos
Nanopartículas Metálicas , Dispositivos Eletrônicos Vestíveis , Humanos , Suor/química , Proteína C-Reativa/análise , Proteína C-Reativa/metabolismo , Ouro , Monitorização Fisiológica , Biomarcadores/metabolismo
15.
Med Sci Sports Exerc ; 55(10): 1941, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37170926
17.
Eur J Appl Physiol ; 123(8): 1599-1625, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36917254

RESUMO

Respiratory function has become a global health priority. Not only is chronic respiratory disease a leading cause of worldwide morbidity and mortality, but the COVID-19 pandemic has heightened attention on respiratory health and the means of enhancing it. Subsequently, and inevitably, the respiratory system has become a target of the multi-trillion-dollar health and wellness industry. Numerous commercial, respiratory-related interventions are now coupled to therapeutic and/or ergogenic claims that vary in their plausibility: from the reasonable to the absurd. Moreover, legitimate and illegitimate claims are often conflated in a wellness space that lacks regulation. The abundance of interventions, the range of potential therapeutic targets in the respiratory system, and the wealth of research that varies in quality, all confound the ability for health and exercise professionals to make informed risk-to-benefit assessments with their patients and clients. This review focuses on numerous commercial interventions that purport to improve respiratory health, including nasal dilators, nasal breathing, and systematized breathing interventions (such as pursed-lips breathing), respiratory muscle training, canned oxygen, nutritional supplements, and inhaled L-menthol. For each intervention we describe the premise, examine the plausibility, and systematically contrast commercial claims against the published literature. The overarching aim is to assist health and exercise professionals to distinguish science from pseudoscience and make pragmatic and safe risk-to-benefit decisions.


Assuntos
COVID-19 , Doença Pulmonar Obstrutiva Crônica , Humanos , Pandemias , Pseudociência , Exercícios Respiratórios
18.
Med Sci Sports Exerc ; 55(6): 1097-1104, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36633582

RESUMO

INTRODUCTION: Several studies report that pulmonary oxygen uptake (V̇O 2 ) at the respiratory compensation point (RCP) is equivalent to the V̇O 2 at critical power (CP), suggesting that the variables can be used interchangeably to demarcate the threshold between heavy and severe intensity domains. However, if RCP is a valid surrogate for CP, their values should correspond even when assessed in patients with chronic obstructive pulmonary disease (COPD) in whom the "normal" mechanisms linking CP and RCP are impeded. The aim of this study was to compare V̇O 2 at CP with V̇O 2 at RCP in patients with COPD. METHODS: Twenty-two COPD patients (14 male/8 female; forced expiratory volume in 1 s, 46% ± 17% pred) performed ramp-incremental cycle ergometry to intolerance (5-10 W·min -1 ) for the determination of gas exchange threshold (GET) and RCP. CP was calculated from the asymptote of the hyperbolic power-duration relationship from 3-5 constant-power exercise tests to intolerance. CP was validated with a 20-min constant-power ride. RESULTS: GET was identified in 20 of 22 patients at a V̇O 2 of 0.93 ± 0.18 L·min -1 (75% ± 13% V̇O 2peak ), whereas RCP was identified in just 3 of 22 patients at a V̇O 2 of 1.40 ± 0.39 L·min -1 (85% ± 2% V̇O 2peak ). All patients completed constant-power trials with no difference in peak physiological responses relative to ramp-incremental exercise ( P > 0.05). CP was 46 ± 22 W, which elicited a V̇O 2 of 1.04 ± 0.29 L·min -1 (90% ± 9% V̇O 2peak ) during the validation ride. The difference in V̇O 2 at 15 and 20 min of the validation ride was 0.00 ± 0.04 L, which was not different from a hypothesized mean of 0 ( P = 0.856), thereby indicating a V̇O 2 steady state. CONCLUSIONS: In COPD patients, who present with cardiopulmonary and/or respiratory-mechanical dysfunction, CP can be determined in the absence of RCP. Accordingly, CP and RCP are not equivalent in this group.


Assuntos
Ergometria , Doença Pulmonar Obstrutiva Crônica , Humanos , Masculino , Feminino , Teste de Esforço , Exercício Físico/fisiologia , Pulmão , Consumo de Oxigênio/fisiologia
19.
Chronic Obstr Pulm Dis ; 10(1): 112-121, 2023 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-36599111

RESUMO

Introduction: Smokers with chronic obstructive pulmonary disease (COPD) are at increased risk of muscle weakness. There are limited data describing weakness in smokers with normal spirometry and preserved ratio-impaired spirometry (PRISm), 2 subgroups at risk of respiratory symptom burden and activity limitations. In this study, we evaluated the associations of 2 weakness measures, sit-to-stand (STS) and handgrip strength (HGS), with clinical outcomes in smokers with COPD, normal spirometry, and PRISm. Methods: We evaluated 1972 current and former smokers from the COPD Genetic Epidemiology (COPDGene®) cohort with STS and HGS measurements at their 10-year study visit. Multivariable regression modeling was used to assess associations between weakness measures and the 6-minute walk distance (6MWD) test, the St George's Respiratory Questionnaire (SGRQ), the Short-Form-36 (SF-36), severe exacerbations, and prospective mortality, reported as standardized coefficients (ß), odds ratios (ORs), or hazard ratios (HRs). Results: Compared with HGS, STS was more strongly associated with the 6MWD (ß=0.45, p<0.001 versus. ß=0.25, p<0.001), SGRQ (ß=-0.24, p<0.001 versus ß=-0.18, p<0.001), SF-36 Physical Functioning (ß=0.36, p<0.001 versus ß=0.25, p<0.001), severe exacerbations (OR 0.95, p=0.04 versus OR 0.97, p=0.01), and prospective mortality (HR 0.83, p=0.001 versus HR 0.94, p=0.03). Correlations remained after stratification by spirometric subgroups. Compared with males, females had larger magnitude effect sizes between STS and clinical outcomes. Conclusions: STS and HGS are easy to perform weakness measures that provide important information about functional performance, health-related quality of life, severe exacerbations, and survival in smokers, regardless of spirometric subgroup. This iterates the importance of screening current and former smokers for weakness in the outpatient setting.

20.
Thorax ; 78(3): 258-266, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36283827

RESUMO

BACKGROUND: Selective androgen receptor modulators (SARMs) increase muscle mass via the androgen receptor. This phase 2A trial investigated the effects of a SARM, GSK2881078, in conjunction with exercise, on leg strength in patients with chronic obstructive pulmonary disease (COPD) and impaired physical function. METHODS: 47 postmenopausal women and 50 men with COPD (forced expiratory volume in 1 s 30%-65% predicted; short physical performance battery score: 3-11) were enrolled into a randomised double-blind, placebo control trial. Patients were randomised 1:1 to once daily placebo or oral GSK2881078 (females: 1.0 mg; males: 2.0 mg) for 13 weeks with a concurrent home-exercise programme, involving strength training and physical activity. Primary endpoints were change from baseline in leg strength at 90 days (one-repetition maximum; absolute (kg) and relative (% change)) and multiple safety outcomes. Secondary endpoints included lean body mass, physical function and patient-reported outcomes. RESULTS: GSK2881078 increased leg strength in men. The difference in adjusted mean change from baseline and adjusted mean percentage change from baseline between treatment and placebo were: for women, 8.0 kg (90% CI -2.5 to 18.4) and 5.2% (90% CI -4.7 to 15.0), respectively; for men, 11.8 kg (90% CI -0.5 to 24.0) and 7.0% (90% CI 0.5 to 13.6), respectively. Lean body mass increased, but no changes in patient-reported outcomes were observed. Reversible reductions in high-density lipoprotein-cholesterol and transient elevations in hepatic transaminases were the main treatment-related safety findings. CONCLUSIONS: GSK2881078 was well tolerated and short-term treatment increased leg strength, when expressed as per cent predicted, in men with COPD more than physical training alone. TRIAL REGISTRATION NUMBER: NCT03359473.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Receptores Androgênicos , Masculino , Humanos , Feminino , Receptores Androgênicos/uso terapêutico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Debilidade Muscular/etiologia , Exercício Físico , Método Duplo-Cego
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA