Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
Magn Reson Med ; 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39219165

RESUMO

PURPOSE: MRI-guidance of cardiac catheterization is currently performed using one or multiple 2D imaging planes, which may be suboptimal for catheter navigation, especially in patients with complex anatomies. The purpose of the work was to develop a robust real-time 3D catheter tracking method and 3D visualization strategy for improved MRI-guidance of cardiac catheterization procedures. METHODS: A fast 3D tracking technique was developed using continuous acquisition of two orthogonal 2D-projection images. Each projection corresponds to a gradient echo stack of slices with only the central k-space lines being collected for each slice. To enhance catheter contrast, a saturation pulse is added ahead of the projection pair. An offline image processing algorithm was developed to identify the 2D coordinates of the balloon in each projection image and to estimate its corresponding 3D coordinates. Post-processing includes background signal suppression using an atlas of background 2D-projection images. 3D visualization of the catheter and anatomy is proposed using three live sagittal, coronal, and axial (MPR) views and 3D rendering. The technique was tested in a subset of a catheterization step in three patients undergoing MRI-guided cardiac catheterization using a passive balloon catheter. RESULTS: The extraction of the catheter balloon 3D coordinates was successful in all patients and for the majority of time-points (accuracy >96%). This tracking method enabled a novel 3D visualization strategy for passive balloon catheter, providing enhanced anatomical context during catheter navigation. CONCLUSION: The proposed tracking strategy shows promise for robust tracking of passive balloon catheter and may enable enhanced visualization during MRI-guided cardiac catheterization.

2.
Magn Reson Med ; 2024 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-39155399

RESUMO

PURPOSE: Myocardial T1ρ mapping techniques commonly acquire multiple images in one breathhold to calculate a single-slice T1ρ map. Recently, non-selective adiabatic pulses have been used for robust spin-lock preparation (T1ρ,adiab). The objective of this study was to develop a fast multi-slice myocardial T1ρ,adiab mapping approach. METHODS: The proposed-sequence reduces the number of breathholds required for whole-heart 2D T1ρ,adiab mapping by acquiring multiple interleaved slices in each breathhold using slice-selective T1ρ,adiab preparation pulses. The proposed-sequence was implemented with two interleaved slices per breathhold scan and was quantitatively evaluated in phantom experiments and 10 healthy-volunteers against a single-slice T1ρ,adiab mapping sequence. The sequence was demonstrated in two patients with myocardial scar. RESULTS: The phantom experiments showed the proposed-sequence had slice-to-slice variation of 1.62% ± 1.05% and precision of 4.51 ± 0.68 ms. The healthy volunteer cohort subject-wise mean relaxation time was lower for the proposed-sequence than the single-slice sequence (137.7 ± 5.3 ms vs. 148.4 ± 8.3 ms, p < 0.001), and spatial-standard-deviation was better (18.7 ± 1.8 ms vs. 21.8 ± 3.4 ms, p < 0.018). The mean within-subject, coefficient of variation was 5.93% ± 1.57% for the proposed-sequence and 6.31% ± 1.92% for the single-slice sequence (p = 0.35) and the effect of slice variation (0.81 ± 4.87 ms) was not significantly different to zero (p = 0.61). In both patient examples increased T1ρ,adiab (maximum American Heart Association-segment mean = 174 and 197 ms) was measured within the myocardial scar. CONCLUSION: The proposed sequence provides a twofold acceleration for myocardial T1ρ,adiab mapping using a multi-slice approach. It has no significant difference in within-subject variability, and significantly better precision, compared to a 2D T1ρ,adiab mapping sequence based on non-selective adiabatic spin-lock preparations.

3.
Front Cardiovasc Med ; 11: 1350345, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39055659

RESUMO

Background: Simultaneous multi-slice (SMS) bSSFP imaging enables stress myocardial perfusion imaging with high spatial resolution and increased spatial coverage. Standard parallel imaging techniques (e.g., TGRAPPA) can be used for image reconstruction but result in high noise level. Alternatively, iterative reconstruction techniques based on temporal regularization (ITER) improve image quality but are associated with reduced temporal signal fidelity and long computation time limiting their online use. The aim is to develop an image reconstruction technique for SMS-bSSFP myocardial perfusion imaging combining parallel imaging and image-based denoising using a novel noise map estimation network (NoiseMapNet), which preserves both sharpness and temporal signal profiles and that has low computational cost. Methods: The proposed reconstruction of SMS images consists of a standard temporal parallel imaging reconstruction (TGRAPPA) with motion correction (MOCO) followed by image denoising using NoiseMapNet. NoiseMapNet is a deep learning network based on a 2D Unet architecture and aims to predict a noise map from an input noisy image, which is then subtracted from the noisy image to generate the denoised image. This approach was evaluated in 17 patients who underwent stress perfusion imaging using a SMS-bSSFP sequence. Images were reconstructed with (a) TGRAPPA with MOCO (thereafter referred to as TGRAPPA), (b) iterative reconstruction with integrated motion compensation (ITER), and (c) proposed NoiseMapNet-based reconstruction. Normalized mean squared error (NMSE) with respect to TGRAPPA, myocardial sharpness, image quality, perceived SNR (pSNR), and number of diagnostic segments were evaluated. Results: NMSE of NoiseMapNet was lower than using ITER for both myocardium (0.045 ± 0.021 vs. 0.172 ± 0.041, p < 0.001) and left ventricular blood pool (0.025 ± 0.014 vs. 0.069 ± 0.020, p < 0.001). There were no significant differences between all methods for myocardial sharpness (p = 0.77) and number of diagnostic segments (p = 0.36). ITER led to higher image quality than NoiseMapNet/TGRAPPA (2.7 ± 0.4 vs. 1.8 ± 0.4/1.3 ± 0.6, p < 0.001) and higher pSNR than NoiseMapNet/TGRAPPA (3.0 ± 0.0 vs. 2.0 ± 0.0/1.3 ± 0.6, p < 0.001). Importantly, NoiseMapNet yielded higher pSNR (p < 0.001) and image quality (p < 0.008) than TGRAPPA. Computation time of NoiseMapNet was only 20s for one entire dataset. Conclusion: NoiseMapNet-based reconstruction enables fast SMS image reconstruction for stress myocardial perfusion imaging while preserving sharpness and temporal signal profiles.

4.
J Cardiovasc Magn Reson ; 26(1): 101000, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38237902

RESUMO

BACKGROUND: Myocardial quantitative susceptibility mapping (QSM) may offer better specificity to iron than conventional T2* imaging in the assessment of cardiac diseases, including intra-myocardial hemorrhage. However, the precision and repeatability of cardiac QSM have not yet been characterized. The aim of this study is to characterize these key metrics in a healthy volunteer cohort and show the feasibility of the method in patients. METHODS: Free breathing respiratory-navigated multi-echo 3D gradient echo images were acquired, from which QSM maps were reconstructed using the Morphology Enhanced Dipole Inversion toolbox. This technique was first evaluated in a susceptibility phantom containing tubes with known concentrations of gadolinium. In vivo characterization of myocardial QSM was then performed in a cohort of 10 healthy volunteers where each subject was scanned twice. Mean segment susceptibility, precision (standard deviation of voxel magnetic susceptibilities within one segment), and repeatability (absolute difference in segment mean susceptibility between repeats) of QSM were calculated for each American Heart Association (AHA) myocardial segment. Finally, the feasibility of the method was shown in 10 patients, including four with hemorrhagic infarcts. RESULTS: The phantom experiment showed a strong linear relationship between measured and predicted susceptibility shifts (R2 > 0.99). For the healthy volunteer cohort, AHA segment analysis showed the mean segment susceptibility was 0.00 ± 0.02 ppm, the mean precision was 0.05 ± 0.04 ppm, and the mean repeatability was 0.02 ± 0.02 ppm. Cardiac QSM was successfully performed in all patients. Focal iron deposits were successfully visualized in the patients with hemorrhagic myocardial infarctions. CONCLUSION: The precision and repeatability of cardiac QSM were successfully characterized in phantom and in vivo experiments. The feasibility of the technique was also successfully demonstrated in patients. While challenges still remain, further clinical evaluation of the technique is now warranted. TRIAL REGISTRATION: This work does not report on a health care intervention.


Assuntos
Estudos de Viabilidade , Ventrículos do Coração , Imagens de Fantasmas , Valor Preditivo dos Testes , Humanos , Reprodutibilidade dos Testes , Masculino , Pessoa de Meia-Idade , Adulto , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Voluntários Saudáveis , Imageamento por Ressonância Magnética , Estudos de Casos e Controles , Idoso , Interpretação de Imagem Assistida por Computador , Meios de Contraste/administração & dosagem , Miocárdio/patologia , Adulto Jovem , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia
5.
Magn Reson Med ; 91(1): 388-397, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37676923

RESUMO

PURPOSE: MR-guided cardiac catheterization procedures currently use passive tracking approaches to follow a gadolinium-filled catheter balloon during catheter navigation. This requires frequent manual tracking and repositioning of the imaging slice during navigation. In this study, a novel framework for automatic real-time catheter tracking during MR-guided cardiac catheterization is presented. METHODS: The proposed framework includes two imaging modes (Calibration and Runtime). The sequence starts in Calibration mode, in which the 3D catheter coordinates are determined using a stack of 10-20 contiguous saturated slices combined with real-time image processing. The sequence then automatically switches to Runtime mode, where three contiguous slices (acquired with partial saturation), initially centered on the catheter balloon using the Calibration feedback, are acquired continuously. The 3D catheter balloon coordinates are estimated in real time from each Runtime slice stack using image processing. Each Runtime stack is repositioned to maintain the catheter balloon in the central slice based on the prior Runtime feedback. The sequence switches back to Calibration mode if the catheter is not detected. This framework was evaluated in a heart phantom and 3 patients undergoing MR-guided cardiac catheterization. Catheter detection accuracy and rate of catheter visibility were evaluated. RESULTS: The automatic detection accuracy for the catheter balloon during the Calibration/Runtime mode was 100%/95% in phantom and 100%/97 ± 3% in patients. During Runtime, the catheter was visible in 82% and 98 ± 2% of the real-time measurements in the phantom and patients, respectively. CONCLUSION: The proposed framework enabled real-time continuous automatic tracking of a gadolinium-filled catheter balloon during MR-guided cardiac catheterization.


Assuntos
Cateterismo Cardíaco , Gadolínio , Humanos , Cateterismo Cardíaco/métodos , Catéteres , Imagens de Fantasmas , Coração
6.
Front Cardiovasc Med ; 10: 1233065, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37859681

RESUMO

Radiofrequency catheter ablation is an established treatment strategy for ventricular tachycardia, but remains associated with a low success rate. MR guidance of ventricular tachycardia shows promises to improve the success rate of these procedures, especially due to its potential to provide real-time information on lesion formation using cardiac MR thermometry. Modern low field MRI scanners (<1 T) are of major interest for MR-guided ablations as the potential benefits include lower costs, increased patient access and device compatibility through reduced device-induced imaging artefacts and safety constraints. However, the feasibility of cardiac MR thermometry at low field remains unknown. In this study, we demonstrate the feasibility of cardiac MR thermometry at 0.55 T and characterized its in vivo stability (i.e., precision) using state-of-the-art techniques based on the proton resonance frequency shift method. Nine healthy volunteers were scanned using a cardiac MR thermometry protocol based on single-shot EPI imaging (3 slices in the left ventricle, 150 dynamics, TE = 41 ms). The reconstruction pipeline included image registration to align all the images, multi-baseline approach (look-up-table length = 30) to correct for respiration-induced phase variations, and temporal filtering to reduce noise in temperature maps. The stability of thermometry was defined as the pixel-wise standard deviation of temperature changes over time. Cardiac MR thermometry was successfully acquired in all subjects and the stability averaged across all subjects was 1.8 ± 1.0°C. Without multi-baseline correction, the overall stability was 2.8 ± 1.6°C. In conclusion, cardiac MR thermometry is feasible at 0.55 T and further studies on MR-guided catheter ablations at low field are warranted.

7.
Front Cardiovasc Med ; 10: 1233093, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37745095

RESUMO

Introduction: Magnetic Resonance Imaging (MRI) is a promising alternative to standard x-ray fluoroscopy for the guidance of cardiac catheterization procedures as it enables soft tissue visualization, avoids ionizing radiation and provides improved hemodynamic data. MRI-guided cardiac catheterization procedures currently require frequent manual tracking of the imaging plane during navigation to follow the tip of a gadolinium-filled balloon wedge catheter, which unnecessarily prolongs and complicates the procedures. Therefore, real-time automatic image-based detection of the catheter balloon has the potential to improve catheter visualization and navigation through automatic slice tracking. Methods: In this study, an automatic, parameter-free, deep-learning-based post-processing pipeline was developed for real-time detection of the catheter balloon. A U-Net architecture with a ResNet-34 encoder was trained on semi-artificial images for the segmentation of the catheter balloon. Post-processing steps were implemented to guarantee a unique estimate of the catheter tip coordinates. This approach was evaluated retrospectively in 7 patients (6M and 1F, age = 7 ± 5 year) who underwent an MRI-guided right heart catheterization procedure with all images acquired in an orientation unseen during training. Results: The overall accuracy, specificity and sensitivity of the proposed catheter tracking strategy over all 7 patients were 98.4 ± 2.0%, 99.9 ± 0.2% and 95.4 ± 5.5%, respectively. The computation time of the deep-learning-based segmentation step was ∼10 ms/image, indicating its compatibility with real-time constraints. Conclusion: Deep-learning-based catheter balloon tracking is feasible, accurate, parameter-free, and compatible with real-time conditions. Online integration of the technique and its evaluation in a larger patient cohort are now warranted to determine its benefit during MRI-guided cardiac catheterization.

8.
Magn Reson Med ; 89(6): 2242-2254, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36763898

RESUMO

PURPOSE: To develop a motion-robust reconstruction technique for free-breathing cine imaging with multiple averages. METHOD: Retrospective motion correction through multiple average k-space data elimination (REMAKE) was developed using iterative removal of k-space segments (from individual k-space samples) that contribute most to motion corruption while combining any remaining segments across multiple signal averages. A variant of REMAKE, termed REMAKE+, was developed to address any losses in SNR due to k-space information removal. With REMAKE+, multiple reconstructions using different initial conditions were performed, co-registered, and averaged. Both techniques were validated against clinical "standard" signal averaging reconstruction in a static phantom (with simulated motion) and 15 patients undergoing free-breathing cine imaging with multiple averages. Quantitative analysis of myocardial sharpness, blood/myocardial SNR, myocardial-blood contrast-to-noise ratio (CNR), as well as subjective assessment of image quality and rate of diagnostic quality images were performed. RESULTS: In phantom, motion artifacts using "standard" (RMS error [RMSE]: 2.2 ± 0.5) were substantially reduced using REMAKE/REMAKE+ (RMSE: 1.5 ± 0.4/1.0 ± 0.4, p < 0.01). In patients, REMAKE/REMAKE+ led to higher myocardial sharpness (0.79 ± 0.09/0.79 ± 0.1 vs. 0.74 ± 0.12 for "standard", p = 0.004/0.04), higher image quality (1.8 ± 0.2/1.9 ± 0.2 vs. 1.6 ± 0.4 for "standard", p = 0.02/0.008), and a higher rate of diagnostic quality images (99%/100% vs. 94% for "standard"). Blood/myocardial SNR for "standard" (94 ± 30/33 ± 10) was higher vs. REMAKE (80 ± 25/28 ± 8, p = 0.002/0.005) and tended to be lower vs. REMAKE+ (105 ± 33/36 ± 12, p = 0.02/0.06). Myocardial-blood CNR for "standard" (61 ± 22) was higher vs. REMAKE (53 ± 19, p = 0.003) and lower vs. REMAKE+ (69 ± 24, p = 0.007). CONCLUSIONS: Compared to "standard" signal averaging reconstruction, REMAKE and REMAKE+ provide improved myocardial sharpness, image quality, and rate of diagnostic quality images.


Assuntos
Coração , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Estudos Retrospectivos , Coração/diagnóstico por imagem , Respiração , Movimento (Física) , Artefatos
9.
Front Cardiovasc Med ; 9: 971869, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36093156

RESUMO

Cardiac MR thermometry shows promise for real-time guidance of radiofrequency ablation of cardiac arrhythmias. This technique uses ECG triggering, which can be unreliable in this situation. A prospective cardiac triggering method was developed for MR thermometry using the active tracking (AT) signal measured from catheter microcoils. In the proposed AT-based cardiac triggering (AT-trig) sequence, AT modules were repeatedly acquired to measure the catheter motion until a cardiac trigger was identified to start cardiac MR thermometry using single-shot echo-planar imaging. The AT signal was bandpass filtered to extract the motion induced by the beating heart, and cardiac triggers were defined as the extremum (peak or valley) of the filtered AT signal. AT-trig was evaluated in a beating heart phantom and in vivo in the left ventricle of a swine during temperature stability experiments (6 locations) and during one ablation. Stability was defined as the standard deviation over time. In the phantom, AT-trig enabled triggering of MR thermometry and resulted in higher temperature stability than an untriggered sequence. In all in vivo experiments, AT-trig intervals matched ECG-derived RR intervals. Mis-triggers were observed in 1/12 AT-trig stability experiments. Comparable stability of MR thermometry was achieved using peak AT-trig (1.0 ± 0.4°C), valley AT-trig (1.1 ± 0.5°C), and ECG triggering (0.9 ± 0.4°C). These experiments show that continuously acquired AT signal for prospective cardiac triggering is feasible. MR thermometry with AT-trig leads to comparable temperature stability as with conventional ECG triggering. AT-trig could serve as an alternative cardiac triggering strategy in situations where ECG triggering is not effective.

10.
J Cardiovasc Magn Reson ; 24(1): 48, 2022 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-35978351

RESUMO

Quantitative susceptibility mapping (QSM) is a powerful, non-invasive, magnetic resonance imaging (MRI) technique that relies on measurement of magnetic susceptibility. So far, QSM has been employed mostly to study neurological disorders characterized by iron accumulation, such as Parkinson's and Alzheimer's diseases. Nonetheless, QSM allows mapping key indicators of cardiac disease such as blood oxygenation and myocardial iron content. For this reason, the application of QSM offers an unprecedented opportunity to gain a better understanding of the pathophysiological changes associated with cardiovascular disease and to monitor their evolution and response to treatment. Recent studies on cardiovascular QSM have shown the feasibility of a non-invasive assessment of blood oxygenation, myocardial iron content and myocardial fibre orientation, as well as carotid plaque composition. Significant technical challenges remain, the most evident of which are related to cardiac and respiratory motion, blood flow, chemical shift effects and susceptibility artefacts. Significant work is ongoing to overcome these challenges and integrate the QSM technique into clinical practice in the cardiovascular field.


Assuntos
Ferro , Imageamento por Ressonância Magnética , Encéfalo , Coração , Humanos , Imageamento por Ressonância Magnética/métodos , Valor Preditivo dos Testes
12.
Eur J Radiol ; 151: 110286, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35452953

RESUMO

PURPOSE: Simultaneous multi-slice (SMS) balanced steady-state free precession (bSSFP) acquisition and iterative reconstruction can provide high spatial resolution and coverage for cardiac magnetic resonance (CMR) perfusion. However, respiratory motion remains a challenge for iterative reconstruction techniques employing temporal regularisation. The aim of this study is to evaluate an iterative reconstruction with integrated motion compensation for SMS-bSSFP first-pass myocardial stress perfusion in the presence of respiratory motion. METHODS: Thirty-one patients with suspected coronary artery disease were prospectively recruited and imaged at 1.5 T. A SMS-bSSFP prototype myocardial perfusion sequence was acquired at stress in all patients. All datasets were reconstructed using an iterative reconstruction with temporal regularisation, once with and once without motion compensation (MC and NMC, respectively). Three readers scored each dataset in terms of: image quality (1:poor; 4:excellent), motion/blurring (1:severe motion/blurring; 3:no motion/blurring), and diagnostic confidence (1:poor confidence; 3:high confidence). Quantitative assessment of sharpness was performed. The number of uncorrupted first-pass dynamics was measured on the NMC datasets to classify patients into 'suboptimal breath-hold (BH)' and 'good BH' groups. RESULTS: Compared across all cases, MC performed better than NMC in terms of image quality (3.5 ± 0.5 vs. 3.0 ± 0.8, P = 0.002), motion/blurring (2.9 ± 0.1 vs. 2.2 ± 0.8, P < 0.001), diagnostic confidence (2.9 ± 0.1 vs. 2.3 ± 0.7, P < 0.001) and sharpness index (0.34 ± 0.05 vs. 0.31 ± 0.06, P < 0.001). Fourteen patients with a suboptimal BH were identified. For the suboptimal BH group, MC performed better than NMC in terms of image quality (3.8 ± 0.4 vs. 2.6 ± 0.8, P < 0.001), motion/blurring (3.0 ± 0.1 vs. 1.6 ± 0.7, P < 0.001), diagnostic confidence (3.0 ± 0.1 vs. 1.9 ± 0.7, P < 0.001) and sharpness index (0.34 ± 0.05 vs. 0.30 ± 0.06, P = 0.004). For the good BH group, sharpness index was higher for MC than NMC (0.34 ± 0.06 vs 0.31 ± 0.07, P = 0.03), while there were no significant differences observed for the other three metrics assessed (P > 0.11). There were no significant differences between suboptimal BH MC and good BH MC for any of the reported metrics (P > 0.06). CONCLUSIONS: Integrated motion compensation significantly reduces motion/blurring and improves image quality, diagnostic confidence and sharpness index of SMS-bSSFP perfusion with iterative reconstruction in the presence of motion.


Assuntos
Suspensão da Respiração , Imageamento por Ressonância Magnética , Coração , Humanos , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Perfusão
13.
Magn Reson Med ; 88(2): 663-675, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35344593

RESUMO

PURPOSE: To implement and evaluate a simultaneous multi-slice balanced SSFP (SMS-bSSFP) perfusion sequence and compressed sensing reconstruction for cardiac MR perfusion imaging with full left ventricular (LV) coverage (nine slices/heartbeat) and high spatial resolution (1.4 × 1.4 mm2 ) at 1.5T. METHODS: A preliminary study was performed to evaluate the performance of blipped controlled aliasing in parallel imaging (CAIPI) and RF-CAIPI with gradient-controlled local Larmor adjustment (GC-LOLA) in the presence of fat. A nine-slice SMS-bSSFP sequence using RF-CAIPI with GC-LOLA with high spatial resolution (1.4 × 1.4 mm2 ) and a conventional three-slice sequence with conventional spatial resolution (1.9 × 1.9 mm2 ) were then acquired in 10 patients under rest conditions. Qualitative assessment was performed to assess image quality and perceived signal-to-noise ratio (SNR) on a 4-point scale (0: poor image quality/low SNR; 3: excellent image quality/high SNR), and the number of myocardial segments with diagnostic image quality was recorded. Quantitative measurements of myocardial sharpness and upslope index were performed. RESULTS: Fat signal leakage was significantly higher for blipped CAIPI than for RF-CAIPI with GC-LOLA (7.9% vs. 1.2%, p = 0.010). All 10 SMS-bSSFP perfusion datasets resulted in 16/16 diagnostic myocardial segments. There were no significant differences between the SMS and conventional acquisitions in terms of image quality (2.6 ± 0.6 vs. 2.7 ± 0.2, p = 0.8) or perceived SNR (2.8 ± 0.3 vs. 2.7 ± 0.3, p = 0.3). Inter-reader variability was good for both image quality (ICC = 0.84) and perceived SNR (ICC = 0.70). Myocardial sharpness was improved using the SMS sequence compared to the conventional sequence (0.37 ± 0.08 vs 0.32 ± 0.05, p < 0.001). There was no significant difference between measurements of upslope index for the SMS and conventional sequences (0.11 ± 0.04 vs. 0.11 ± 0.03, p = 0.84). CONCLUSION: SMS-bSSFP with multiband factor 3 and compressed sensing reconstruction enables cardiac MR perfusion imaging with three-fold increased spatial coverage and improved myocardial sharpness compared to a conventional sequence, without compromising perceived SNR, image quality, upslope index or number of diagnostic segments.


Assuntos
Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Ventrículos do Coração/diagnóstico por imagem , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Perfusão , Reprodutibilidade dos Testes
14.
Magn Reson Med ; 87(2): 702-717, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34554603

RESUMO

PURPOSE: To investigate the use of a high flip-angle (HFA) balanced SSFP (bSSFP) reference image (in comparison to conventional proton density [PD]-weighted reference images) for conversion of bSSFP myocardial perfusion images into dynamic T1 maps for improved myocardial blood flow (MBF) quantification at 1.5 T. METHODS: The HFA-bSSFP (flip angle [FA] = 50°), PD gradient-echo (PD-GRE; FA = 5°), and PD-bSSFP (FA = 8°) reference images were acquired before a dual-sequence bSSFP perfusion acquisition. Simulations were used to study accuracy and precision of T1 and MBF quantification using the three techniques. The accuracy and precision of T1 , and the precision and intersegment variability of MBF were compared among the three techniques in 8 patients under rest conditions. RESULTS: In simulations, HFA-bSSFP demonstrated improved T1 /MBF precision (higher T1 /MBF SD of 30%-80%/50%-100% and 30%-90%/60%-115% for PD-GRE and PD-bSSFP, respectively). Proton density-GRE and PD-bSSFP were more sensitive to effective FA than HFA-bSSFP (maximum T1 /MBF errors of 13%/43%, 20%/43%, and 1%/3%, respectively). Sensitivity of all techniques (defined as T1 /MBF errors) to native T1 , native T2 , and effective saturation efficiency were negligible (<1%/<1%), moderate (<14%/<19%), and high (<63%/<94%), respectively. In vivo, no difference in T1 accuracy was observed among HFA-bSSFP, PD-GRE, and PD-bSSFP (-9 ± 44 ms vs -28 ± 55 ms vs -22 ± 71 ms, respectively; p > .08). The HFA-bSSFP led to improved T1 /MBF precision (T1 /MBF SD: 41 ± 19 ms/0.24 ± 0.08 mL/g/min vs PD-GRE: 48 ± 20 ms/0.29 ± 0.09 mL/g/min and PD-bSSFP: 59 ± 23 ms/0.33 ± 0.11 mL/g/min; p ≤ .02) and lower MBF intersegment variability (0.14 ± 0.09 mL/g/min vs PD-GRE: 0.21 ± 0.09 mL/g/min and PD-bSSFP: 0.20 ± 0.10 mL/g/min; p ≤ .046). CONCLUSION: We have demonstrated the feasibility of using a HFA-bSSFP reference image for MBF quantification of bSSFP perfusion imaging at 1.5 T. Results from simulations demonstrate that the HFA-bSSFP reference image results in improved precision and reduced sensitivity to effective FA compared with conventional techniques using a PD reference image. Preliminary in vivo data acquired at rest also demonstrate improved precision and intersegment variability using the HFA-bSSFP technique compared with PD techniques; however, a clinical study in patients with coronary artery disease under stress conditions is required to determine the clinical significance of this finding.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Circulação Coronária , Humanos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes
15.
Front Cardiovasc Med ; 8: 744779, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34765656

RESUMO

Background: The majority of data regarding tissue substrate for post myocardial infarction (MI) VT has been collected during hemodynamically tolerated VT, which may be distinct from the substrate responsible for VT with hemodynamic compromise (VT-HC). This study aimed to characterize tissue at diastolic locations of VT-HC in a porcine model. Methods: Late Gadolinium Enhancement (LGE) cardiovascular magnetic resonance (CMR) imaging was performed in eight pigs with healed antero-septal infarcts. Seven pigs underwent electrophysiology study with venous arterial-extra corporeal membrane oxygenation (VA-ECMO) support. Tissue thickness, scar and heterogeneous tissue (HT) transmurality were calculated at the location of the diastolic electrograms of mapped VT-HC. Results: Diastolic locations had median scar transmurality of 33.1% and a median HT transmurality 7.6%. Diastolic activation was found within areas of non-transmural scar in 80.1% of cases. Tissue activated during the diastolic component of VT circuits was thinner than healthy tissue (median thickness: 5.5 mm vs. 8.2 mm healthy tissue, p < 0.0001) and closer to HT (median distance diastolic tissue: 2.8 mm vs. 11.4 mm healthy tissue, p < 0.0001). Non-scarred regions with diastolic activation were closer to steep gradients in thickness than non-scarred locations with normal EGMs (diastolic locations distance = 1.19 mm vs. 9.67 mm for non-diastolic locations, p < 0.0001). Sites activated late in diastole were closest to steep gradients in tissue thickness. Conclusions: Non-transmural scar, mildly decreased tissue thickness, and steep gradients in tissue thickness represent the structural characteristics of the diastolic component of reentrant circuits in VT-HC in this porcine model and could form the basis for imaging criteria to define ablation targets in future trials.

17.
Magn Reson Med ; 86(2): 663-676, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33749026

RESUMO

PURPOSE: To enable all-systolic first-pass rest myocardial perfusion with long saturation times. To investigate the change in perfusion contrast and dark rim artefacts through simulations and surrogate measurements. METHODS: Simulations were employed to investigate optimal saturation time for myocardium-perfusion defect contrast and blood-to-myocardium signal ratios. Two saturation recovery blocks with long/short saturation times (LTS/STS) were employed to image 3 slices at end-systole and diastole. Simultaneous multi-slice balanced steady state free precession imaging and compressed sensing acceleration were combined. The sequence was compared to a 3 slice-by-slice clinical protocol in 10 patients. Quantitative assessment of myocardium-peak pre contrast and blood-to-myocardium signal ratios, as well as qualitative assessment of perceived SNR, image quality, blurring, and dark rim artefacts, were performed. RESULTS: Simulations showed that with a bolus of 0.075 mmol/kg, a LTS of 240-470 ms led to a relative increase in myocardium-perfusion defect contrast of 34% ± 9%-28% ± 27% than a STS = 120 ms, while reducing blood-to-myocardium signal ratio by 18% ± 10%-32% ± 14% at peak myocardium. With a bolus of 0.05 mmol/kg, LTS was 320-570 ms with an increase in myocardium-perfusion defect contrast of 63% ± 13%-62% ± 29%. Across patients, LTS led to an average increase in myocardium-peak pre contrast of 59% (P < .001) at peak myocardium and a lower blood-to-myocardium signal ratio of 47% (P < .001) and 15% (P < .001) at peak blood/myocardium. LTS had improved motion robustness (P = .002), image quality (P < .001), and decreased dark rim artefacts (P = .008) than the clinical protocol. CONCLUSION: All-systolic rest perfusion can be achieved by combining simultaneous multi-slice and compressed sensing acceleration, enabling 3-slice cardiac coverage with reduced motion and dark rim artefacts. Numerical simulations indicate that myocardium-perfusion defect contrast increases at LTS.


Assuntos
Imageamento por Ressonância Magnética , Imagem de Perfusão do Miocárdio , Aceleração , Meios de Contraste , Coração/diagnóstico por imagem , Humanos , Perfusão , Sístole
18.
Magn Reson Med ; 85(5): 2661-2671, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33270946

RESUMO

PURPOSE: To develop and evaluate a fast respiratory navigator (fastNAV) for cardiac MR perfusion imaging with subject-specific prospective slice tracking. METHODS: A fastNAV was developed for dynamic contrast-enhanced cardiac MR perfusion imaging by combining spatially nonselective saturation with slice-selective tip-up and slice-selective excitation pulses. The excitation slice was angulated from the tip-up slice in the transverse plane to overlap only in the right hemidiaphragm for suppression of signal outside the right hemidiaphragm. A calibration scan was developed to enable the estimation of subject-specific tracking factors. Perfusion imaging using subject-specific fastNAV-based slice tracking was then compared to a conventional sequence (ie, without slice tracking) in 10 patients under free-breathing conditions. Respiratory motion in perfusion images was quantitatively assessed by measuring the average overlap of the left ventricle across images (avDice, 0:no overlap/1:perfect overlap) and the average displacement of the center of mass of the left ventricle (avCoM). Image quality was subjectively assessed using a 4-point scoring system (1: poor, 4: excellent). RESULTS: The fastNAV calibration was successfully performed in all subjects (average tracking factor of 0.46 ± 0.13, R = 0.94 ± 0.03). Prospective motion correction using fastNAV led to higher avDice (0.94 ± 0.02 vs. 0.90 ± 0.03, P < .001) and reduced avCoM (4.03 ± 0.84 vs. 5.22 ± 1.22, P < .001). There were no statistically significant differences between the 2 sequences in terms of image quality (both sequences: median = 3 and interquartile range = 3-4, P = 1). CONCLUSION: fastNAV enables fast and robust right hemidiaphragm motion tracking in a perfusion sequence. In combination with subject-specific slice tracking, fastNAV reduces the effect of respiratory motion during free-breathing cardiac MR perfusion imaging.


Assuntos
Imagem de Perfusão do Miocárdio , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Movimento (Física) , Estudos Prospectivos
19.
Magn Reson Med ; 85(4): 2069-2083, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33201524

RESUMO

PURPOSE: To develop a novel gadolinium-free model-based quantitative magnetization transfer (qMT) technique to assess macromolecular changes associated with myocardial fibrosis. METHODS: The proposed sequence consists of a two-dimensional breath-held dual shot interleaved acquisition of five MT-weighted (MTw) spoiled gradient echo images, with variable MT flip angles (FAs) and off-resonance frequencies. A two-pool exchange model and dictionary matching were used to quantify the pool size ratio (PSR) and bound pool T2 relaxation ( T2B ). The signal model was developed and validated using 25 MTw images on a bovine serum albumin (BSA) phantom and in vivo human thigh muscle. A protocol with five MTw images was optimized for single breath-hold cardiac qMT imaging. The proposed sequence was tested in 10 healthy subjects and 5 patients with myocardial fibrosis and compared to late gadolinium enhancement (LGE). RESULTS: PSR values in the BSA phantom were within the confidence interval of previously reported values (concentration 10% BSA = 5.9 ± 0.1%, 15% BSA = 9.4 ± 0.2%). PSR and T2B in thigh muscle were also in agreement with literature (PSR = 10.9 ± 0.3%, T2B = 6.4 ± 0.4 us). In 10 healthy subjects, global left ventricular PSR was 4.30 ± 0.65%. In patients, PSR was reduced in areas associated with LGE (remote: 4.68 ± 0.70% vs. fibrotic: 3.12 ± 0.78 %, n = 5, P < .002). CONCLUSION: In vivo model-based qMT mapping of the heart was performed for the first time, with promising results for non-contrast enhanced assessment of myocardial fibrosis.


Assuntos
Cardiomiopatias , Meios de Contraste , Cardiomiopatias/diagnóstico por imagem , Fibrose , Gadolínio , Humanos , Imageamento por Ressonância Magnética
20.
J Magn Reson Imaging ; 53(5): 1446-1457, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33155758

RESUMO

BACKGROUND: Improvements in outcomes for patients with congenital heart disease (CHD) have increased the need for diagnostic and interventional procedures. Cumulative radiation risk is a growing concern. MRI-guided interventions are a promising ionizing radiation-free, alternative approach. PURPOSE: To assess the feasibility of MRI-guided catheterization in young patients with CHD using advanced visualization passive tracking techniques. STUDY TYPE: Prospective. POPULATION: A total of 30 patients with CHD referred for MRI-guided catheterization and pulmonary vascular resistance analysis (median age/weight: 4 years / 15 kg). FIELD STRENGTH/SEQUENCE: 1.5T; partially saturated (pSAT) real-time single-shot balanced steady-state free-precession (bSSFP) sequence. ASSESSMENT: Images were visualized by a single viewer on the scanner console (interactive mode) or using a commercially available advanced visualization platform (iSuite, Philips). Image quality for anatomy and catheter visualization was evaluated by three cardiologists with >5 years' experience in MRI-catheterization using a 1-5 scale (1, poor, 5, excellent). Catheter balloon signal-to-noise ratio (SNR), blood and myocardium SNR, catheter balloon/blood contrast-to-noise ratio (CNR), balloon/myocardium CNR, and blood/myocardium CNR were measured. Procedure findings, feasibility, and adverse events were recorded. A fraction of time in which the catheter was visible was compared between iSuite and the interactive mode. STATISTICAL TESTS: T-test for numerical variables. Wilcoxon signed rank test for categorical variables. RESULTS: Nine patients had right heart catheterization, 11 had both left and right heart catheterization, and 10 had single ventricle circulation. Nine patients underwent solely MRI-guided catheterization. The mean score for anatomical visualization and contrast between balloon tip and soft tissue was 3.9 ± 0.9 and 4.5 ± 0.7, respectively. iSuite provided a significant improvement in the time during which the balloon was visible in relation to interactive imaging mode (66 ± 17% vs. 46 ± 14%, P < 0.05). DATA CONCLUSION: MRI-guided catheterizations were carried out safely and is feasible in children and adults with CHD. The pSAT sequence offered robust and simultaneous high contrast visualization of the catheter and cardiac anatomy. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 1.


Assuntos
Cardiopatias Congênitas , Imagem por Ressonância Magnética Intervencionista , Adulto , Cateterismo Cardíaco , Criança , Pré-Escolar , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA