Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Indian Prosthodont Soc ; 24(1): 61-68, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38263559

RESUMO

AIM: The aim of this within-subject prospective clinical study was to investigate the scope of single implant mandibular overdenture by assessing its masticatory efficiency, clinical performance, and patient satisfaction compared to conventional complete dentures. SETTINGS AND DESIGN: Prospective In Vivo Study. MATERIAL AND METHODS: This prospective in vivo study was conducted in the Department of Prosthodontics and Crown and Bridge, Christian Dental College, Ludhiana. A total of 12 completely edentulous patients received a single implant in the mandibular anterior midline region. After the healing period, the conventional maxillary and mandibular dentures were fabricated. 15 days post insertion of the conventional dentures, patients were evaluated for masticatory efficiency, clinical performance including retention and stability, and patient satisfaction. To evaluate the masticatory efficiency blue raspberry and original pink "Hubba Bubba tape gum" were used as a test food. Colorimetric analysis was done to assess variance of hue. To assess clinical performance, retention, and stability of the mandibular denture was recorded using a digital force gauge and was tabulated as per CU-modified Kapur's criteria. OHIP-14 index was used to assess patient satisfaction. After evaluation of the parameters of conventional dentures, the denture was converted into an implant-retained mandibular denture by chairside conversion with locator attachments. 15 days post-implant loading, parameters of the implant retained mandibular overdenture were assessed again followed by statistical analysis. STATISTICAL ANALYSIS USED: The masticatory efficiency was assessed using a paired t-test. The patient satisfaction was sequentially assessed with Wilcoxon signed rank test and thereafter paired t-test was used to compare between conventional complete denture and overdenture. Clinical performance was assessed using the Wilcoxon signed rank test. RESULTS: The masticatory efficiency of single implant mandibular overdenture was higher than that of conventional complete dentures. The clinical performance of the overdenture was higher than that of the conventional denture. Stability being a time-dependent parameter might need longer follow-ups for further conclusions. Patient satisfaction with single implant retained overdenture was significantly higher than conventional complete dentures. CONCLUSION: Single implant mandibular overdenture has improved masticatory efficiency, clinical performance, and patient satisfaction compared to conventional complete dentures.


Assuntos
Implantes Dentários , Satisfação do Paciente , Humanos , Revestimento de Dentadura , Estudos Prospectivos , Prótese Total
2.
J Prosthet Dent ; 130(4): 611.e1-611.e7, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37643941

RESUMO

STATEMENT OF PROBLEM: The development of digital dental technologies has enabled clinicians to use additive and subtractive manufacturing techniques to fabricate interim restorations. However, knowledge of the trueness and precision of such restorations fabricated using digital light processing (DLP) and computer-aided design and computer-aided manufacturing (CAD-CAM) methods is limited. PURPOSE: The purpose of this in vitro study was to assess and compare the accuracy of interim crowns fabricated using DLP and CAD-CAM methods. MATERIAL AND METHODS: A typodont mandibular first molar was prepared for a ceramic crown, and a digital scan (Medit T500) was obtained to design interim crowns by using the CAD software program. The CAD data were designated as the reference data. A total of 20 crowns were fabricated by DLP and CAD-CAM technology. The fabricated interim crowns were further scanned using a laboratory scanner and were superimposed with the CAD data by using a 3-dimensional (3D) point cloud assessing software program (CloudCompare) for the evaluation of trueness and precision. Root mean square values (RMS) were obtained for the evaluation of discrepancies. The Student t test was used to compare data as the Shapiro-Wilk test confirmed the normal distribution. RESULTS: RMS values for the trueness values of the external and intaglio surfaces of the 3D printed and milled interim crown displayed no statistically significant differences (P>.05). Precision for the external surface reported significance (P<.05), whereas that for the intaglio surface reported no significance (P>.05). CONCLUSIONS: The accuracy of interim crowns fabricated by using DLP was comparable with that of milled crowns. Both manufacturing systems produced a true reproduction of the CAD. As for precision, the external surface of the DLP interim crown was statistically different from that of the milled group as it relates to the CAD.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA