1.
J Robot Surg ; 18(1): 54, 2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38280064

RESUMO

Robot-assisted surgery is increasingly used in surgery for cancer. Reduced overview and loss of anatomical orientation are challenges that might be solved with image-guided surgical navigation using electromagnetic tracking (EMT). However, the robot's presence may distort the electromagnetic field, affecting EMT accuracy. The aim of this study was to evaluate the robot's influence on EMT accuracy. For this purpose, two different electromagnetic field generators were used inside a clinical surgical environment: a table top field generator (TTFG) and a planar field generator (PFG). The position and orientation of sensors within the electromagnetic field were measured using an accurate in-house developed 3D board. Baseline accuracy was measured without the robot, followed by stepwise introduction of potential distortion sources (robot and robotic instruments). The absolute accuracy was determined within the entire 3D board and in the clinical working volume. For the baseline setup, median errors in the entire tracking volume within the 3D board were 0.9 mm and 0.3° (TTFG), and 1.1 mm and 0.4° (PFG). Adding the robot and instruments did not affect the TTFG's position accuracy (p = 0.60), while the PFG's accuracies decreased to 1.5 mm and 0.7° (p < 0.001). For both field generators, when adding robot and instruments, accuracies inside the clinical working volume were higher compared to the entire tracking 3D board volume, 0.7 mm and 0.3° (TTFG), and 1.1 mm and 0.7° (PFG). Introduction of a surgical robot and robotic instruments shows limited distortion of the EMT field, allowing sufficient accuracy for surgical navigation in robotic procedures.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Cirurgia Assistida por Computador , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Fenômenos Eletromagnéticos , Cirurgia Assistida por Computador/métodos
2.
Int J Comput Assist Radiol Surg ; 18(9): 1725-1734, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37227572

RESUMO

PURPOSE: Surgical navigation techniques can guide surgeons in localizing pelvic-abdominal malignancies. For abdominal navigation, accurate patient registration is crucial and is generally performed using an intra-operative cone-beam CT (CBCT). However, this method causes 15-min surgical preparation workflow interruption and radiation exposure, and more importantly, it cannot be repeated during surgery to compensate for large patient movement. As an alternative, the accuracy and feasibility of tracked ultrasound (US) registration are assessed in this patient study. METHODS: Patients scheduled for surgical navigation during laparotomy of pelvic-abdominal malignancies were prospectively included. In the operating room, two percutaneous tracked US scans of the pelvic bone were acquired: one in supine and one in Trendelenburg patient position. Postoperatively, the bone surface was semiautomatically segmented from US images and registered to the bone surface on the preoperative CT scan. The US registration accuracy was computed using the CBCT registration as a reference and acquisition times were compared. Additionally, both US measurements were compared to quantify the registration error caused by patient movement into Trendelenburg. RESULTS: In total, 18 patients were included and analyzed. US registration resulted in a mean surface registration error of 1.2 ± 0.2 mm and a mean target registration error of 3.3 ± 1.4 mm. US acquisitions were 4 × faster than the CBCT scans (two-sample t-test P < 0.05) and could even be performed during standard patient preparation before skin incision. Patient repositioning in Trendelenburg caused a mean target registration error of 7.7 ± 3.3 mm, mainly in cranial direction. CONCLUSION: US registration based on the pelvic bone is accurate, fast and feasible for surgical navigation. Further optimization of the bone segmentation algorithm will allow for real-time registration in the clinical workflow. In the end, this would allow intra-operative US registration to correct for large patient movement. TRIAL REGISTRATION: This study is registered in ClinicalTrials.gov (NCT05637359).


Assuntos
Neoplasias Abdominais , Neoplasias Pélvicas , Cirurgia Assistida por Computador , Humanos , Estudos de Viabilidade , Ultrassonografia , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pélvicas/diagnóstico por imagem , Neoplasias Pélvicas/cirurgia , Cirurgia Assistida por Computador/métodos , Imageamento Tridimensional
3.
Ned Tijdschr Geneeskd ; 1652021 05 12.
Artigo em Holandês | MEDLINE | ID: mdl-34346580

RESUMO

OBJECTIVE: In the Netherlands, the surgical mask is part of the standard surgical attire even for the non-sterile personnel in the operation theatre. Solid evidence on the effect on postoperative infection rates is missing. Due to a national scarcity in surgical masks during the first wave of the COVID-19 crisis the usage of these masks was decreased. In our tertiary referral centre for Surgical Oncology, this led to the decision that, for a period of ten weeks, the surgical masks were only being used by the sterile surgical team and not by non-sterile operation theatre personnel. This retrospective study evaluates the influence of this intervention in terms of postoperative wound infection rates. DESIGN: Retrospective cohort study. METHOD: Consecutive patients undergoing surgery during the first COVID-19 wave (2-3-2020 until 11-05-2020) were compared with patients undergoing surgery in the same period a year earlier. Patients undergoing surgery for soft-tissue malignancies were included. Intra-abdominal surgery was excluded. Primary outcome measurement was wound infection rate within 30 days following surgery. Secondary, a cost reduction analysis was made. RESULTS: In the COVID-19 wave, a total of 219 patients underwent surgery for soft-tissue malignancies, compared to 241 a year earlier. The incidence of postoperative wound infection was 58/460 (12.6%) for the total cohort. There was no difference in infection rate between the COVID-19 period and the same period in 2019; 25/219 (11,4%; 95% CI: 7,8-16,4)) vs. 33/241 (13,7%; 95% CI: 9,8-18,6), p = 0,46) respectively. During the COVID-19 wave, a total of 6.400 of surgical masks were used by the personnel in the operation theatre complex, compared to a total of 11.000 in the same period in 2019. This resulted in a reduction of 42% in usage of surgical masks. CONCLUSION: Based on this mono-centric, explorative retrospective cohort study, it seems that omitting the surgical mask for the non-sterile operation theatre personnel does not influence the postoperative wound infection rate. Despite the fact that our sample size is small, the impressive reduction in usage of 42% demands further research initiatives on a larger scale.


Assuntos
COVID-19 , Máscaras , Humanos , Estudos Retrospectivos , SARS-CoV-2 , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/prevenção & controle
4.
Eur J Surg Oncol ; 47(9): 2220-2232, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33895027

RESUMO

The main challenge for radical resection in oral cancer surgery is to obtain adequate resection margins. Especially the deep margin, which can only be estimated based on palpation during surgery, is often reported inadequate. To increase the percentage of radical resections, there is a need for a quick, easy, minimal invasive method, which assesses the deep resection margin without interrupting or prolonging surgery. This systematic review provides an overview of technologies that are currently being studied with the aim of fulfilling this demand. A literature search was conducted through the databases Medline, Embase and the Cochrane Library. A total of 62 studies were included. The results were categorized according to the type of technique: 'Frozen Section Analysis', 'Fluorescence', 'Optical Imaging', 'Conventional imaging techniques', and 'Cytological assessment'. This systematic review gives for each technique an overview of the reported performance (accuracy, sensitivity, specificity, positive predictive value, negative predictive value, or a different outcome measure), acquisition time, and sampling depth. At the moment, the most prevailing technique remains frozen section analysis. In the search for other assessment methods to evaluate the deep resection margin, some technologies are very promising for future use when effectiveness has been shown in larger trials, e.g., fluorescence (real-time, sampling depth up to 6 mm) or optical techniques such as hyperspectral imaging (real-time, sampling depth few mm) for microscopic margin assessment and ultrasound (less than 10 min, sampling depth several cm) for assessment on a macroscopic scale.


Assuntos
Secções Congeladas , Margens de Excisão , Neoplasias Bucais/diagnóstico por imagem , Neoplasias Bucais/cirurgia , Imagem Óptica/métodos , Técnicas Citológicas , Fluorescência , Humanos , Imageamento por Ressonância Magnética , Neoplasias Bucais/patologia , Tomografia Computadorizada por Raios X , Ultrassonografia
5.
Sci Rep ; 11(1): 4657, 2021 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-33633247

RESUMO

The purpose of this study was to evaluate the feasibility of electromagnetic (EM) navigation for guidance on osteotomies in patients undergoing oncologic mandibular surgery. Preoperatively, a 3D rendered model of the mandible was constructed from diagnostic computed tomography (CT) images. Cutting guides and patient specific reconstruction plates were designed and printed for intraoperative use. Intraoperative patient registration was performed using a cone beam CT scan (CBCT). The location of the mandible was tracked with an EM sensor fixated to the mandible. The real-time location of both the mandible and a pointer were displayed on the navigation system. Accuracy measurements were performed by pinpointing four anatomical landmarks and four landmarks on the cutting guide using the pointer on the patient and comparing these locations to the corresponding locations on the CBCT. Differences between actual and virtual locations were expressed as target registration error (TRE). The procedure was performed in eleven patients. TREs were 3.2 ± 1.1 mm and 2.6 ± 1.5 mm using anatomical landmarks and landmarks on the cutting guide, respectively. The navigation procedure added on average half an hour to the duration of the surgery. This is the first study that reports on the accuracy of EM navigation in patients undergoing mandibular surgery.


Assuntos
Campos Eletromagnéticos , Mandíbula/cirurgia , Procedimentos Cirúrgicos Ortognáticos/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador
6.
Br J Oral Maxillofac Surg ; 58(3): 285-290, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32044145

RESUMO

We wanted to find out whether ultrasound (US) can be used to assess the deep resection margins after excision of squamous cell carcinoma (SCC) of the tongue, as intraoperative feedback on their condition might help to prevent them being too close. Resected specimens of cancers of the tongue from 31 patients with SCC of the tongue were suspended in US gel and scanned with a small 5-10MHz US probe. The tumour was readily visible and US could differentiate it from muscle tissue. The margin of normal tongue musculature surrounding the tumour was measured on the US images, and the minimal resection margin was noted and compared with that reported by the histopathologist. The mean (SD) deep resection margins measured on the US images differed by 1.1 (0.9) mm from those reported by the histopathologist (Pearson's correlation coefficient: 0.79, p<0.01). The US measurements took a maximum of five minutes. It is feasible to use US to assess resection specimens of SCC of the tongue as an adjunct to existing strategies (such as frozen section analysis) to help achieve the desired deep surgical margins. The method is easy to incorporate into surgical routine as it does not take long.


Assuntos
Carcinoma de Células Escamosas , Neoplasias da Língua , Secções Congeladas , Humanos , Margens de Excisão , Língua
7.
J Transl Med ; 17(1): 333, 2019 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-31578153

RESUMO

BACKGROUND: In colorectal cancer surgery there is a delicate balance between complete removal of the tumor and sparing as much healthy tissue as possible. Especially in rectal cancer, intraoperative tissue recognition could be of great benefit in preventing positive resection margins and sparing as much healthy tissue as possible. To better guide the surgeon, we evaluated the accuracy of diffuse reflectance spectroscopy (DRS) for tissue characterization during colorectal cancer surgery and determined the added value of DRS when compared to clinical judgement. METHODS: DRS spectra were obtained from fat, healthy colorectal wall and tumor tissue during colorectal cancer surgery and results were compared to histopathology examination of the measurement locations. All spectra were first normalized at 800 nm, thereafter two support vector machines (SVM) were trained using a tenfold cross-validation. With the first SVM fat was separated from healthy colorectal wall and tumor tissue, the second SVM distinguished healthy colorectal wall from tumor tissue. RESULTS: Patients were included based on preoperative imaging, indicating advanced local stage colorectal cancer. Based on the measurement results of 32 patients, the classification resulted in a mean accuracy for fat, healthy colorectal wall and tumor of 0.92, 0.89 and 0.95 respectively. If the classification threshold was adjusted such that no false negatives were allowed, the percentage of false positive measurement locations by DRS was 25% compared to 69% by clinical judgement. CONCLUSION: This study shows the potential of DRS for the use of tissue classification during colorectal cancer surgery. Especially the low false positive rate obtained for a false negative rate of zero shows the added value for the surgeons. Trail registration This trail was performed under approval from the internal review board committee (Dutch Trail Register NTR5315), registered on 04/13/2015, https://www.trialregister.nl/trial/5175 .


Assuntos
Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/cirurgia , Cirurgia Colorretal , Óptica e Fotônica/métodos , Idoso , Neoplasias Colorretais/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade , Análise Espectral , Cirurgiões
8.
Eur J Surg Oncol ; 45(11): 2131-2136, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31227341

RESUMO

INTRODUCTION: In the 8th edition of the AJCC/UICC cancer staging system (AJCC8), the depth of invasion (DOI) of the oral cavity tumor is the discriminative factor in tumor staging over the previously used greatest dimension (GD). In order to obtain a complete representation of how accurate we stage oral cavity cancer clinically, we evaluated the accuracy of measurements of the tumor dimensions on ultrasound (US) and magnetic resonance (MR) imaging by comparing this with the histopathology as the "golden standard". Secondly, we compared the pathological tumor staging of these tumors according to the AJCC7 and AJCC8, to evaluate the effect of the incorporation of the DOI in the AJCC8. MATERIALS AND METHODS: In a retrospective analysis, including 85 oral cavity tumors, the GD and tumor thickness (TT) measured on US and MR, were compared to histopathology with a Pearson correlation coefficient (R) and a Bland-Altman plot. The tumors were staged according to both the AJCC7 and AJCC8. RESULTS: TT was more reliably measured with US (R = 0.67, limits of agreement = 10.7 mm), whereas GD was more reliably measured with MR (R = 0.69, limits of agreement = 25.7 mm). The AJCC8 staging resulted into a higher tumor stage in 21% of the cases, compared to the AJCC7. CONCLUSION: For preoperative tumor staging, the TT is best estimated by the use of US. The incorporation of DOI in the AJCC8 can result in a higher tumor stage in more than twenty percent of the patients, with an associated worse prognosis for the patient.


Assuntos
Neoplasias Bucais/diagnóstico por imagem , Neoplasias Bucais/patologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Carcinoma de Células Escamosas de Cabeça e Pescoço/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/patologia , Neoplasias de Cabeça e Pescoço/cirurgia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neoplasias Bucais/cirurgia , Invasividade Neoplásica , Estadiamento de Neoplasias , Carcinoma de Células Escamosas de Cabeça e Pescoço/cirurgia , Carga Tumoral , Ultrassonografia
11.
Br J Oral Maxillofac Surg ; 57(2): 174-181, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30712957

RESUMO

Resection of maxillary cancer often results in incomplete excision because of the tumour's proximity to important structures such as the orbit. To deal with this problem we prospectively investigated the feasibility of intraoperative imaging during maxillectomy to verify the planned resection margins. In total, six patients diagnosed with maxillary cancer listed for maxillectomy were included, irrespective of the histological type of tumour. Before resection, an accurate intended resection volume was delineated on diagnostic images. At the end of the operation we took a cone-beam computed tomographic (CT) scan of the treated maxilla, after which the accuracy of the resection was quantitatively evaluated by comparing the preoperative resection plan and the images acquired intraoperatively, based on the anatomy. Further resection was then done if necessary and quantitatively evaluated with a second cone-beam CT scan. Postoperatively we compared the results of the scan with those of the histological examination. Of the six, two resections were reported pathologically as less than radical, each of which was detected by intraoperative CT and resulted in extensions of the original resections. The mean (SD) distance between the planned and the actual resection was 1.49 (2.78)mm. This suggests that intraoperative cone-beam CT imaging is a promising way to make an adequate intraoperative assessment of planned surgical margins of maxillary tumours. This allows for intraoperative resection margins to be improved, possibly leading to a better prognosis for the patient.


Assuntos
Maxila/diagnóstico por imagem , Cirurgia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico , Humanos , Margens de Excisão , Neoplasias Maxilares
12.
Breast ; 33: 50-56, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28282587

RESUMO

OBJECTIVES: Accurate tumour localisation is essential for breast-conserving surgery of non-palpable tumours. Current localisation technologies are associated with disadvantages such as logistical challenges and migration issues (wire guided localisation) or legislative complexities and high administrative burden (radioactive localisation). We present MAgnetic MArker LOCalisation (MaMaLoc), a novel technology that aims to overcome these disadvantages using a magnetic marker and a magnetic detection probe. This feasibility study reports on the first experience with this new technology for breast cancer localisation. MATERIALS AND METHODS: Fifteen patients with unifocal, non-palpable breast cancer were recruited. They received concurrent placement of the magnetic marker in addition to a radioactive iodine seed, which is standard of care in our clinic. In a subset of five patients, migration of the magnetic marker was studied. During surgery, a magnetic probe and gammaprobe were alternately used to localise the markers and guide surgery. The primary outcome parameter was successful transcutaneous identification of the magnetic marker. Additionally, data on radiologist and surgeon satisfaction were collected. RESULTS: Magnetic marker placement was successful in all cases. Radiologists could easily adapt to the technology in the clinical workflow. Migration of the magnetic marker was negligible. The primary endpoint of the study was met with an identification rate of 100%. Both radiologists and surgeons reflected that the technology was intuitive to use and that it was comparable to radioactive iodine seed localisation. CONCLUSION: Magnetic marker localisation for non-palpable breast cancer is feasible and safe, and may be a viable non-radioactive alternative to current localisation technologies.


Assuntos
Neoplasias da Mama/diagnóstico , Marcadores Fiduciais , Radioisótopos do Iodo , Imãs , Compostos Radiofarmacêuticos , Adulto , Neoplasias da Mama/patologia , Estudos de Viabilidade , Feminino , Humanos , Palpação
13.
Surg Oncol ; 26(1): 37-45, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28317583

RESUMO

PURPOSE: Uncertainty exists regarding the optimal imaging modality for timely detection of disease progression (DP) after ablation therapy for colorectal liver metastases. We evaluated the diagnostic accuracy of 18F-FDG PET(/CT), CT and MRI for detection of DP following ablation therapy. METHODS: A systematic search was performed on May 18, 2016. The analysis included studies that reported on the diagnostic accuracy of 18F-FDG PET(/CT), CT and/or MRI for post-ablative evaluation of patients with liver metastases. Primary outcome was the diagnostic accuracy of the imaging modalities for detection of DP. Methodological quality was assessed using the QUADAS-2 tool. Pooled sensitivities and specificities were estimated using bivariate random-effects models. RESULTS: Ten studies were included in the meta-analysis, including seven comparative studies. Nine reported data on diagnostic accuracy of 18F-FDG PET(/CT), seven on CT imaging. Only two studies reported the diagnostic accuracy of MRI, hence not included in the meta-analysis. Quality assessment raised concerns about the risk of bias regarding the use of the reference standard, blinding of the index tests and the follow-up time. Pooled sensitivity was respectively 84.6% (75.0-90.6) and 53.4% (29.0-76.4) for 18F-FDG PET(/CT) and CT (P = 0.005). Pooled specificity was respectively 92.4% (86.5-95.9) and 95.7% (87.5-98.6) (P = 0.392). CONCLUSION: 18F-FDG PET/(CT) yields a higher sensitivity for detecting DP after ablation therapy compared with CT and has a comparably high specificity. These findings indicate that the use of 18F-FDG PET(/CT) in this setting particularly allows for minimization of the false-negative rate compared with CT without compromising the low false-positive rate.


Assuntos
Ablação por Cateter/métodos , Neoplasias Colorretais/patologia , Fluordesoxiglucose F18 , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/terapia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia
14.
Eur J Nucl Med Mol Imaging ; 44(7): 1165-1175, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28180965

RESUMO

PURPOSE: Recurrent disease following thermal ablation therapy is a frequently reported problem. Preoperative identification of patients with high risk of recurrent disease might enable individualized treatment based on patients' risk profile. The aim of the present work was to investigate the role of metabolic parameters derived from the pre-ablation 18F-FDG PET/CT as imaging biomarkers for recurrent disease in patients with colorectal liver metastases (CLM). METHODS: Included in this retrospective study were all consecutive patients with CLM treated with percutaneous or open thermal ablation therapy who had a pre-treatment baseline 18F-FDG PET/CT available. Multivariable cox regression for survival analysis was performed using different models for the metabolic parameters (SULpeak, SULmean, SULmax, partial volume corrected SULmean (cSULmean), and total lesion glycolysis (TLG)) corrected for tumour and procedure characteristics. The study endpoints were defined as local tumour progression free survival (LTP-FS), new intrahepatic recurrence free survival (NHR-FS) and extrahepatic recurrence free survival (EHR-FS). Clinical and imaging follow-up data was used as the reference standard. RESULTS: Fifty-four patients with 90 lesions were selected. Univariable cox regression analysis resulted in eight models. Multivariable analysis revealed that after adjusting for lesion size and the approach of the procedure, none of the metabolic parameters were associated with LTP-FS or EHR-FS. Percutaneous approach was significantly associated with a shorter LTP-FS. It was demonstrated that lower values of SULpeak, SULmax, SULmean , and cSULmean are associated with a significant better NHR-FS, independent of the lesion size and number and prior chemotherapy. CONCLUSION: We found no association between the metabolic parameters on pre-ablation 18F-FDG PET/CT and the LTP-FS. However, low values of the metabolic parameters were significantly associated with improved NHR-FS. The clinical implication of these findings might be the identification of high-risk patients who might benefit most from adjuvant or combined treatment strategies.


Assuntos
Técnicas de Ablação , Neoplasias Colorretais/patologia , Progressão da Doença , Fluordesoxiglucose F18 , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/secundário , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/metabolismo , Feminino , Humanos , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
Eur J Surg Oncol ; 42(2): 251-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26746090

RESUMO

BACKGROUND: The success of radiofrequency (RF) ablation is limited by the inability to assess thermal tissue damage achieved during or immediately after the procedure. The goal of this proof-of-principle study was to investigate whether diffuse reflectance (DR) spectroscopy during and after RF ablation of liver tumours could aid in detecting complete tissue ablation. MATERIAL AND METHODS: DR spectra were acquired in vivo in eight patients undergoing RF ablation for unresectable colorectal liver metastases, using a disposable spectroscopy needle. Intraoperative ultrasound imaging was used for accurate positioning of the RF electrode and the spectroscopy needle. Spectral changes were quantified and correlated to tissue histopathology and follow-up CT imaging. RESULTS: For the lesions in which ablation was monitored by DR spectroscopy (N = 8), median tumour size was 1.6 cm (range 0.8-3.3 cm). We found an excellent correlation (97-99%) between thermal damage suggested by spectral changes and histology. DR spectroscopy allowed discrimination between non-ablated and ablated tissue, regardless whether the needle was placed in tumour tissue or in surrounding liver tissue. Additional measurements performed continuously during ablation confirmed that the magnitude of spectral change correlates with the histochemical degree of thermal damage. CONCLUSIONS: Diffuse reflectance spectroscopy allows accurate quantification of thermal tissue damage during and after RF ablation. Real-time feedback by DR spectroscopy could improve the accuracy and quality of the RF procedures by lowering incomplete ablation rates.


Assuntos
Ablação por Cateter , Neoplasias Colorretais/patologia , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Análise Espectral/métodos , Idoso , Área Sob a Curva , Feminino , Humanos , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Curva ROC , Tomografia Computadorizada por Raios X , Carga Tumoral
16.
Breast Cancer Res Treat ; 152(3): 509-18, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26141407

RESUMO

Recognition of the tumor during breast-conserving surgery (BCS) can be very difficult and currently a robust method of margin assessment for the surgical setting is not available. As a result, tumor-positive margins, which require additional treatment, are not found until histopathologic evaluation. With diffuse reflectance spectroscopy (DRS), tissue can be characterized during surgery based on optical parameters that are related to the tissue morphology and composition. Here we investigate which optical parameters are able to detect tumor in an area with a mixture of benign and tumor tissue and hence which parameters are most suitable for intra-operative margin assessment. DRS spectra (400-1600 nm) were obtained from 16 ex vivo lumpectomy specimens from benign, tumor border, and tumor tissue. One mastectomy specimen was used with a custom-made grid for validation purposes. The optical parameter related to the absorption of fat and water (F/W-ratio) in the extended near-infrared wavelength region (~1000-1600 nm) provided the best discrimination between benign and tumor sites resulting in a sensitivity and specificity of 100 % (excluding the border sites). Per patient, the scaled F/W-ratio gradually decreased from grossly benign tissue towards the tumor in 87.5 % of the specimens. In one test case, based on a predefined F/W-ratio for boundary tissue of 0.58, DRS produced a surgical resection plane that nearly overlapped with a 2-mm rim of benign tissue, 2 mm being the most widely accepted definition of a negative margin. The F/W-ratio provided excellent discrimination between sites clearly inside or outside the tumor and was able to detect the border of the tumor in one test case. This work shows the potential for DRS to guide the surgeon during BCS.


Assuntos
Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Análise Espectral/métodos , Neoplasias da Mama/química , Feminino , Humanos , Período Intraoperatório , Mastectomia Segmentar , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Água
17.
Lasers Surg Med ; 47(7): 559-565, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26192889

RESUMO

BACKGROUND: Surgery for colorectal cancer aims for complete tumor resection. Optical-based techniques can identify tumor and surrounding tissue through the tissue specific optical properties, absorption and scattering, which are both influenced by the biochemical and morphological composition of the tissue. OBJECTIVE: To evaluate the feasibility of dual-modality Diffuse Reflectance Spectroscopy-Fluorescence Spectroscopy (DRS-FS) for discrimination between healthy and malignant tissue in colorectal surgery. METHODS: Surgical specimens from colorectal cancer patients were measured immediately after resection using a fiber-optic needle capable of dual-modality DRS-FS. Model-based analyses were used to derive scattering and absorption coefficients and intrinsic fluorescence. Volume fractions of chromophores were estimated. Furthermore, optical data were recorded along a trajectory from healthy tissue towards tumor. RESULTS: Spectral characteristics were identified in 1,273 measured spectra from 21 specimens. Combined DRS and FS discriminated tumor from surrounding tissue with a sensitivity of 95% and a specificity of 88%. Significant spectral changes were seen along the trajectory from healthy tissue to tumor. CONCLUSION: This study demonstrates that dual-modality DRS-FS can identify colorectal cancer from surrounding healthy tissue. The quantification of comprehensible parameters allows robust classification and facilitates extrapolation towards the clinical setting. The technique, here demonstrated in a needle like probe, can be incorporated into surgical tools for optically guided surgery in the near future. Lasers Surg. Med. 47:559-565, 2015. © 2015 Wiley Periodicals, Inc.

18.
J Eur Acad Dermatol Venereol ; 29(4): 738-44, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25175118

RESUMO

BACKGROUND: Cutaneous melanomas are diagnosed worldwide in 231,130 patients per year. The sensitivity and specificity of melanoma diagnosis expresses the need for an additional diagnostic method. Optical coherence tomography (OCT) has shown that it allows morphological (qualitative) description of image features and quantitative analysis of pathology related light scattering by means of the attenuation coefficient (µoct ). OBJECTIVE: We hypothesize that OCT images of nevi will differ qualitatively and quantitatively from melanomas. METHODS: Forty lesions from 33 consecutive patients were imaged with OCT. After data acquisition, excision was performed. Epidermal layer thickness was measured and values of µoct were extracted from 200 OCT images of pigmented lesions. RESULTS: Morphologically, absence of the lower border of the lesion was characteristic for melanoma (P = 0.02). Also, the µoct was different between benign and malignant lesions (P = 0.02). There were no differences in epidermal layer thickness of benign lesions and melanoma. CONCLUSION: Although this preliminary study comprised a small number of patients, quantitative analysis of OCT images in pigmented skin lesions give valuable additional information about lesions characteristics. When using the attenuation coefficient, it might be possible to distinguish between benign lesions and melanomas.


Assuntos
Melanoma/patologia , Nevo Pigmentado/patologia , Neoplasias Cutâneas/patologia , Tomografia de Coerência Óptica , Adulto , Epiderme/patologia , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC
19.
Eur J Cancer ; 50(5): 912-9, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24411080

RESUMO

AIM: The aim of this study is to describe local tumour control after radiofrequency ablation (RFA) and surgical resection (RES) of colorectal liver metastases (CLM) in two independent European Organisations for Research and Treatment of Cancer (EORTC) studies. BACKGROUND: Only 10-20% of patients with newly diagnosed CLM are eligible for curative RES. RFA has found a place in daily practice for unresectable CLM. There are no prospective trials comparing RFA to RES for resectable CLM. METHODS: The CLOCC trial randomised 119 patients with unresectable CLM between RFA (±RES)+adjuvant FOLFOX (±bevacizumab) versus FOLFOX (±bevacizumab) alone. The EPOC trial randomised 364 patients with resectable CLM between RES±perioperative FOLFOX. We describe the local control of resected patients with lesions ≤4 cm in the perioperative chemotherapy arm of the EPOC trial (N=81) and the RFA arm of the CLOCC trial (N=55). RESULTS: Local recurrence (LR) rate for RES was 7.4% per patient and 5.5% per lesion. LR rate for RFA was 14.5% per patient and 6.0% per lesion. When lesion size was limited to 30 mm, LR rate for RFA lesions was 2.9% per lesion. Non-local hepatic recurrences were more often observed in RFA patients than in RES patients, 30.9% and 22.3% respectively. Patients receiving RFA had a more advanced disease. CONCLUSIONS: LR rate after RFA for lesions with a limited size is low. The local control per lesion does not appear to differ greatly between RFA and surgical resection. This study supports the local control of RFA in patients with limited liver metastases. Future studies should evaluate in which patients RFA could be an equal alternative to liver resection.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Ablação por Cateter , Neoplasias Colorretais/terapia , Neoplasias Hepáticas/terapia , Adulto , Idoso , Anticorpos Monoclonais Humanizados/administração & dosagem , Bevacizumab , Quimioterapia Adjuvante , Neoplasias Colorretais/patologia , Terapia Combinada , Intervalo Livre de Doença , Esquema de Medicação , Feminino , Fluoruracila/administração & dosagem , Humanos , Leucovorina/administração & dosagem , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Compostos Organoplatínicos/administração & dosagem , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
20.
Lasers Med Sci ; 29(3): 1297-305, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23504262

RESUMO

Optical coherence tomography (OCT) is an optical technique that measures the backscattering of near-infrared light by tissue. OCT yields in 2D and 3D images at micrometer-scale resolution, thus providing optical biopsies, approaching the resolution of histopathological imaging. The technique has shown to allow in vivo differentiation between benign and malignant epithelial tissue, through qualitative assessment of OCT images, as well as by quantitative evaluation, e.g., functional OCT. This study aims to summarize the principles of OCT and to discuss the current literature on the diagnostic value of OCT in the diagnosis of epithelial (pre)malignant lesions. The authors did a systematic search of the electronic databases PubMed and Embase on OCT in the diagnostic process of (pre)malignant epithelial lesions. OCT is able to differentiate between benign and (pre)malignant lesions of epithelial origin in a wide variety of tissues. In this way, OCT can detect skin cancers, oral, laryngeal, and esophageal cancer as well as genital and bladder cancer. OCT is an innovative technique which enables an optical biopsy of epithelial lesions. The incorporation of OCT in specific tools, like handheld and catheter-based probes, will further improve the implementation of this technology in daily clinical practice.


Assuntos
Epitélio/patologia , Tomografia de Coerência Óptica/métodos , Biópsia , Humanos , Neoplasias/patologia
SELEÇÃO DE REFERÊNCIAS