Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Int J Cardiol ; 405: 131939, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38458388

RESUMO

BACKGROUND: Advances in imaging have led to procedural optimization of left atrial appendage closure (LAAC). Contrast-free approaches, guided merely by echocardiography, have been established, however data on this topic remains scarce. In this analysis, we assessed contrast-free procedural results with the LAMBRE LAAC device. METHODS: The multicenter retrospective BoBoMa (Bonn/Bordeaux/Mainz)-Registry included a total of 118 patients that underwent LAAC with LAMBRE devices omitting contrast-dye. Baseline and echocardiographic characteristics as well as intra- and postprocedural complications and outcomes were assessed. RESULTS: Patients were at a mean age of 77.5 ± 7.5 years with high thromboembolic and bleeding risk (CHADS-VASc-score 4.6 ± 1.4, HAS-BLED-score 3.7 ± 1.0, respectively). Renal function was impaired with a mean glomerular filtration rate (GFR) of 50 ± 22 ml/min. Mean procedural time was 47.2 ± 37.5  minutes with a mean radiation dose of 4.75 ± 5.25 Gy*cm2. Device success, defined as proper deployment in a correct position, was achieved in 97.5% (115/118) of cases with repositioning of the occluder in 7.6% (9/118) and resizing in 3.4% (4/118) of cases. No relevant peri-device leakage (>3 mm) was observed with 42% of occluders being implanted in an ostial position. Periprocedural complications occurred in 6.8% (8/118) of cases, including two cases of device embolization and one case of clinically-relevant pericardial effusion requiring surgical intervention. Other complications included pericardial effusion (2.5%, 3/118) and vascular access site complications (1.7%, 2/118). CONCLUSION: Echocardiography-guided contrast-free LAAC using the LAMBRE device is safe and feasible. Further prospective studies including the direct comparison of devices as well as imaging techniques are warranted in contrast-free LAAC.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Humanos , Apêndice Atrial/cirurgia , Apêndice Atrial/diagnóstico por imagem , Masculino , Feminino , Idoso , Estudos Retrospectivos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Idoso de 80 Anos ou mais , Sistema de Registros , Resultado do Tratamento , Ecocardiografia Transesofagiana/métodos , Meios de Contraste/administração & dosagem , Seguimentos
2.
Front Cardiovasc Med ; 11: 1223588, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38468721

RESUMO

Background: There are different types of transcatheter mitral valve repair (TMVr) currently in clinical use, including leaflet approximation, annular cinching, and restoration of the chordal apparatus of the mitral valve (MV). While the concomitant combination (COMBO) therapy of mitral transcatheter edge-to-edge repair (M-TEER) with another TMVr concept has been proven feasible, potentially offering patient-tailored treatment for severe mitral regurgitation (MR), a comparison with M-TEER alone has not been made. Aims: To evaluate the procedural and clinical outcome of COMBO therapies compared with M-TEER alone. Methods: We included consecutive patients undergoing COMBO and M-TEER between March 2015 and April 2018 at our Heart Valve Center, while excluding patients presenting a case of redo or with previous MV surgery. Procedural outcomes and all-cause mortality were compared between COMBO therapy vs. M-TEER alone. Results: A total of 357 patients (mean age 78.9 ± 7.0 years, 53.2% male, M-TEER n = 322, COMBO n = 35; COMBO: MitraClip and the Carillon mitral contour system n = 26, MitraClip and Cardioband n = 5, and MitraClip and NeoChord n = 4) were analyzed. Patients with COMBO therapy had larger left chamber sizes, a lower left ventricular systolic ejection fraction (LVEF; COMBO: 37.4 ± 13.8%, M-TEER: 47.9 ± 14.3%, p < 0.001), and a more severe MR grade (p < 0.001). There were no significant differences in the prevalence of residual MR ≧2+. However, the need for re-intervention, always employing M-TEER, was more common in the COMBO group. During a mean 3.6-year long-term follow-up, there was no significant difference of all-cause mortality between both groups (Log rank p = 0.921). Conclusions: COMBO therapy may still be a beneficial therapy option for patients with severe MR who already have a more dilated left ventricle (LV), a more severe MR, and a more pronounced LV systolic dysfunction. The higher need for re-intervention in the COMBO group may signal more complex anatomies and possibly underlines the necessity of treating significant MR earlier. Future research is required to establish the COMBO approach as a toolbox-like treatment option, thus offering a patient-tailored approach depending on the individual anatomy and pathology.

3.
Eur Heart J Case Rep ; 8(2): ytae060, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38374984

RESUMO

Background: Patients requiring coronary intervention after acute myocardial infarction, with decompensated heart failure and multiple co-morbidities, present a challenging clinical scenario. Addressing such high-risk cases has been a marked increase in the simultaneous support using microaxial flow pump devices, providing a crucial haemodynamic support during procedures. Case summary: We report the case of a 58-year-old man, with a non-ST-segment elevation myocardial infarction in the context of a peripheral vascular surgery. Echocardiography revealed severely reduced left ventricular function and cardiac magnetic resonance imaging demonstrated transmural scars in all but left anterior descending artery area. The patient was of extreme high surgical risk due to the multiple co-morbidities, acute decompensation heart failure, and peripheral artery disease, and, therefore, the heart team preferred protected percutaneous coronary intervention (PCI) over coronary artery bypass graft for revascularization. The peripheral artery disease included severely calcified ascending aorta, occlusions of both femoral arteries, the left subclavian artery, and the right radial artery. Taken together, the heart team agreed on a hybrid approach with surgical implantation of Impella 5.0 via the left subclavian artery, by a single-access technique. Following the intervention procedure, haemostasis of the vascular prosthesis was achieved by an angio-seal technique without complications. The patient recovered satisfactorily, with improved left ventricular function, and discharged 10 days post-procedure. Discussion: The single-access high-risk PCI technique offers a standardized approach for microaxial flow pump devices such as Impella 5.0 and PCI. The subclavian artery as a single-access route for high-risk PCI has demonstrated safety and efficacy.

4.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38099912

RESUMO

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Masculino , Feminino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Idoso , Fatores de Risco , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Fatores de Tempo , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas , Estudos de Viabilidade , Medição de Risco , Desenho de Prótese , Ecocardiografia Tridimensional
5.
J Am Heart Assoc ; 12(24): e031881, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38084735

RESUMO

BACKGROUND: We previously reported procedural and 30-day outcomes of a German early multicenter experience with the PASCAL system for severe mitral regurgitation (MR). This study reports 1-year outcomes of mitral valve transcatheter edge-to-edge repair with the PASCAL system according to MR etiology in a large all-comer cohort. METHODS AND RESULTS: Clinical and echocardiographic outcomes up to 1-year were investigated according to MR etiology (degenerative [DMR], functional [FMR], or mixed [MMR]) in the first 282 patients with symptomatic MR 3+/4+ treated with the PASCAL implant at 9 centers in 2019. A total of 282 patients were included (33% DMR, 50% FMR, 17% MMR). At discharge, MR reduction to ≤1+/2+ was achieved in 58%/87% of DMR, in 75%/97% of FMR, and in 78%/98% of patients with MMR (P=0.004). MR reduction to ≤1+/2+ was sustained at 30 days (50%/83% DMR, 67%/97% FMR, 74%/100% MMR) and at 1 year (53%/78% DMR, 75%/97% FMR, 67%/91% MMR) with significant differences between etiologies. DMR patients with residual MR 3+/4+ at 1-year had at least complex valve morphology in 91.7%. Valve-related reintervention was performed in 7.4% DMR, 0.7% FMR, and 0.0% MMR (P=0.010). At 1-year, New York Heart Association Functional Class was significantly improved irrespective of MR etiology (P<0.001). CONCLUSIONS: In this large all-comer cohort, mitral valve transcatheter edge-to-edge repair with the PASCAL system was associated with an acute and sustained MR reduction at 1-year in all causes. However, in patients with DMR, MR reduction was less pronounced, reflecting the high incidence of complex or very complex anatomies being referred for mitral valve transcatheter edge-to-edge repair.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/etiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Sistema de Registros , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/efeitos adversos
6.
Artigo em Inglês | MEDLINE | ID: mdl-37962288

RESUMO

BACKGROUND: The CLASP IID (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical) trial is the first randomized controlled trial comparing the PASCAL system and the MitraClip system in prohibitive risk patients with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: The study sought to report primary and secondary endpoints and 1-year outcomes for the full cohort of the CLASP IID trial. METHODS: Prohibitive-risk patients with 3+/4+ DMR were randomized 2:1 (PASCAL:MitraClip). One-year assessments included secondary effectiveness endpoints (mitral regurgitation [MR] ≤2+ and MR ≤1+), and clinical, echocardiographic, functional, and quality-of-life outcomes. Primary safety (30-day composite major adverse events [MAE]) and effectiveness (6-month MR ≤2+) endpoints were assessed for the full cohort. RESULTS: Three hundred patients were randomized (PASCAL: n = 204; MitraClip: n = 96). At 1 year, differences in survival, freedom from heart failure hospitalization, and MAE were nonsignificant (P > 0.05 for all). Noninferiority of the PASCAL system compared with the MitraClip system persisted for the primary endpoints in the full cohort (For PASCAL vs MitraClip, the 30-day MAE rates were 4.6% vs 5.4% with a rate difference of -0.8% and 95% upper confidence bound of 4.6%. The 6-month MR≤2+ rates were 97.9% vs 95.7% with a rate difference of 2.2% and 95% lower confidence bound (LCB) of -2.5%, for, respectively). Noninferiority was met for the secondary effectiveness endpoints at 1 year (MR≤2+ rates for PASCAL vs MitraClip were 95.8% vs 93.8% with a rate difference of 2.1% and 95% LCB of -4.1%. The MR≤1+ rates were 77.1% vs 71.3% with a rate difference of 5.8% and 95% LCB of -5.3%, respectively). Significant improvements in functional classification and quality of life were sustained in both groups (P <0.05 for all vs baseline). CONCLUSIONS: The CLASP IID trial full cohort met primary and secondary noninferiority endpoints, and at 1 year, the PASCAL system demonstrated high survival, significant MR reduction, and sustained improvements in functional and quality-of-life outcomes. Results affirm the PASCAL system as a beneficial therapy for prohibitive-surgical-risk patients with significant symptomatic DMR.

7.
JACC Cardiovasc Interv ; 16(23): 2820-2832, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-37905772

RESUMO

BACKGROUND: Favorable 6-month outcomes from the CLASP IID Registry (Edwards PASCAL transcatheter valve repair system pivotal clinical trial) demonstrated that mitral valve transcatheter edge-to-edge repair with the PASCAL transcatheter valve repair system is safe and beneficial for treating prohibitive surgical risk degenerative mitral regurgitation (DMR) patients with complex mitral valve anatomy. OBJECTIVES: The authors sought to assess 1-year safety, echocardiographic and clinical outcomes from the CLASP IID Registry. METHODS: Patients with 3+ or 4+ DMR who were at prohibitive surgical risk, had complex mitral valve anatomy based on the MitraClip Instructions for Use, and deemed suitable for treatment with the PASCAL system were enrolled prospectively. Safety, clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. Study oversight included a central screening committee, echocardiographic core laboratory, and clinical events committee. RESULTS: Ninety-eight patients were enrolled. One-year Kaplan-Meier (KM) estimates of freedom from composite major adverse events, all-cause mortality, and heart failure hospitalization were 83.5%, 89.3%, and 91.5%, respectively. Significant mitral regurgitation (MR) reduction was achieved at 1 year (P < 0.001 vs baseline) including 93.2% at MR ≤2+ and 57.6% at MR ≤1+ with improvements in related echocardiographic measures. NYHA functional class and Kansas City Cardiomyopathy Questionnaire score also improved significantly (P < 0.001 vs baseline). CONCLUSIONS: At 1 year, treatment with the PASCAL system demonstrated safety and significant MR reduction, with continued improvement in clinical, echocardiographic, functional, and quality-of-life outcomes, illustrating the value of the PASCAL system in the treatment of prohibitive surgical risk patients with 3+ or 4+ DMR and complex mitral valve anatomy.


Assuntos
Cateterismo Cardíaco , Insuficiência da Valva Mitral , Humanos , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Ensaios Clínicos como Assunto
8.
Circ Cardiovasc Interv ; 16(8): e012888, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37582170

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is a common and progressive valve disease with significant mortality and hospitalization burden. Tricuspid transcatheter edge-to-edge repair provides a treatment option for high-risk patients with primary and secondary TR. METHODS: The TRILUMINATE trial ([Trial to Evaluate Treatment With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater Tricuspid Regurgitation]; n=85) is an international, prospective, single-arm, multicenter study to investigate the safety and performance of tricuspid transcatheter edge-to-edge repair with the TriClip implant in patients with symptomatic moderate or greater TR. Echocardiographic assessment was performed at a core laboratory. Outcomes included safety and clinical effectiveness and echocardiographic assessment of TR. RESULTS: At 2 years, TR was reduced to moderate or less in 60% of subjects, and reduction of at least 1 grade was achieved in 85.4% of subjects. TR reduction was sustained in 75% of the patients. While most metrics suggest the majority of favorable remodeling occurred within the first 30 days post-procedure, both right ventricular end diastolic diameter and tricuspid annular plane systolic excursion show signals of continued favorable remodeling through 2 years. Substantial improvements in 6-minute walking distance, New York Heart Association functional class, and Kansas City Cardiomyopathy Questionnaire score were sustained from 30 days to 2 years. Even with low rates of cardiovascular mortality (15.3%) and all-cause mortality (18.7%) noted at 2 years, all-cause hospitalization rate decreased from 1.30 events per patient-year 1 year before device implantation to 0.66 events per patient-year 2 years after the TriClip procedure, representing a reduction of 49% (P<0.0001). CONCLUSIONS: Tricuspid transcatheter edge-to-edge repair using the TriClip implant was found to be safe and effective, with sustained benefits at 2 years in subjects with symptomatic moderate or greater TR. Repair efficacy was durable at 2 years in 75% of the patients. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03227757.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Resultado do Tratamento , Estudos Prospectivos , Cateterismo Cardíaco , Índice de Gravidade de Doença
9.
Arch Cardiovasc Dis ; 116(6-7): 352-356, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37391341

RESUMO

Structural heart interventions are steadily increasing, and the majority requires echocardiographic guidance. As a result, imaging specialists are exposed to the harmful effects of scattered ionizing radiation. This X-ray exposure must be quantified, its potential consequences should be monitored by occupational medicine and the "as low as reasonably achievable" principles of radioprotection should be optimized (including increasing the distance, decreasing the duration, using shielding radiation and providing safety training for the imaging specialist). The spatial organization of and shielding provision in the procedural rooms should be designed to optimize radioprotection for all team members.


Assuntos
Exposição à Radiação , Lesões por Radiação , Proteção Radiológica , Humanos , Lesões por Radiação/etiologia , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Ecocardiografia , Doses de Radiação , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle
10.
JACC Cardiovasc Interv ; 16(8): 896-905, 2023 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-37100553

RESUMO

BACKGROUND: Guideline-directed medical therapy (GDMT) optimization is mandatory before transcatheter edge-to-edge mitral valve repair (M-TEER) in patients with secondary mitral regurgitation (SMR) and heart failure (HF) with reduced ejection fraction (HFrEF). However, the effect of M-TEER on GDMT is unknown. OBJECTIVES: The authors sought to evaluate frequency, prognostic implications and predictors of GDMT uptitration after M-TEER in patients with SMR and HFrEF. METHODS: This is a retrospective analysis of prospectively collected data from the EuroSMR Registry. The primary events were all-cause death and the composite of all-cause death or HF hospitalization. RESULTS: Among the 1,641 EuroSMR patients, 810 had full datasets regarding GDMT and were included in this study. GDMT uptitration occurred in 307 patients (38%) after M-TEER. Proportion of patients receiving angiotensin-converting enzyme inhibitors/angiotensin receptor blockers/angiotensin receptor-neprilysin inhibitors, beta-blockers, and mineralocorticoid receptor antagonists was 78%, 89%, and 62% before M-TEER and 84%, 91%, and 66% 6 months after M-TEER (all P < 0.001). Patients with GDMT uptitration had a lower risk of all-cause death (adjusted HR: 0.62; 95% CI: 0.41-0.93; P = 0.020) and of all-cause death or HF hospitalization (adjusted HR: 0.54; 95% CI: 0.38-0.76; P < 0.001) compared with those without. Degree of MR reduction between baseline and 6-month follow-up was an independent predictor of GDMT uptitration after M-TEER (adjusted OR: 1.71; 95% CI: 1.08-2.71; P = 0.022). CONCLUSIONS: GDMT uptitration after M-TEER occurred in a considerable proportion of patients with SMR and HFrEF and is independently associated with lower rates for mortality and HF hospitalizations. A greater decrease in MR was associated with increased likelihood for GDMT uptitration.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Volume Sistólico , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações
11.
Front Cardiovasc Med ; 10: 1029103, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36873404

RESUMO

Aims: For patients with severe mitral valve regurgitation (MR), different kinds of transcatheter mitral valve repair (TMVr) exist, targeting the leaflets, annulus, and chordae. The concomitant combination (COMBO) therapy of TMVrs is rarely used as treatment, and there are very few publications about this therapeutic strategy. We evaluated the effect of COMBO-TMVr on the cardiac left chambers and clinical data, including survival. Methods: We included 35 patients at high risk who underwent concomitant sequential transcatheter mitral valve edge-to-edge repair (M-TEER) and another TMVr for severe MR in our hospital between March 2015 and April 2018. Of these, 13 had adequate follow-up transthoracic echocardiography (TTE) up to around 1 year after the procedure. Results: Survival for all patients was 83% at 1 year, 71% at 2 years, and 63% at 3 years, respectively. In the 13 patients with adequate TTE follow-up, M-TEER plus either Cardioband (n = 4), Carillon Mitral Contour System (n = 7), or Neochord (n = 2) were used, respectively. Ten patients had secondary, and three patients primary MR. After 1 year, changes [median (Q1, Q3)] of left ventricular (LV) end-systolic diameter of -9.9 cm (-11.1, 0.4), LV end-diastolic diameter of -3.3 cm (-8.5, 0.0), LV end-systolic volume (LVESV) of -17.4 mL (-32.6, -0.4), LV end-diastolic volume (LVEDV) of -13.5 mL (-15.9, -3.2), LV mass of -19.5 g (-24.2, -7.6), and left atrial volume (LAV) index (LAVi) of -16.4 mL (-23.3, -11.3) were observed. A significant reduction was also seen in the change ratios of LVESV, LVEDV, LV mass, and LAVi, respectively. Conclusion: We found that COMBO therapy of TMVr seems feasible and may support reverse remodeling of left cardiac chambers during 1 year after the procedure in a cohort of patients at high risk.

12.
JACC Cardiovasc Interv ; 16(2): 140-151, 2023 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-36697148

RESUMO

BACKGROUND: Secondary mitral regurgitation (SMR) is a progressive disease with characteristic pathophysiological changes that may influence prognosis. Although the staging of SMR patients suffering from heart failure with reduced ejection fraction (HFrEF) according to extramitral cardiac involvement has prognostic value in medically treated patients, such data are so far lacking for edge-to-edge mitral valve repair (M-TEER). OBJECTIVES: This study sought to classify M-TEER patients into disease stages based on the phenotype of extramitral cardiac involvement and to assess its impact on symptomatic and survival outcomes. METHODS: Based on echocardiographic and clinical assessment, patients were assigned to 1 of the following HFrEF-SMR groups: left ventricular involvement (Stage 1), left atrial involvement (Stage 2), right ventricular volume/pressure overload (Stage 3), or biventricular failure (Stage 4). A Cox regression model was implemented to investigate the impact of HFrEF-SMR stages on 2-year all-cause mortality. The symptomatic outcome was assessed with New York Heart Association functional class at follow-up. RESULTS: Among a total of 849 eligible patients who underwent M-TEER for relevant SMR from 2008 until 2019, 9.5% (n = 81) presented with left ventricular involvement, 46% (n = 393) with left atrial involvement, 15% (n = 129) with right ventricular pressure/volume overload, and 29% (n = 246) with biventricular failure. An increase in HFrEF-SMR stage was associated with increased 2-year all-cause mortality after M-TEER (HR: 1.39; CI: 1.23-1.58; P < 0.01). Furthermore, higher HFrEF-SMR stages were associated with significantly less symptomatic improvement at follow-up. CONCLUSIONS: The classification of M-TEER patients into HFrEF-SMR stages according to extramitral cardiac involvement provides prognostic value in terms of postinterventional survival and symptomatic improvement.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Volume Sistólico
13.
Int J Cardiol ; 371: 312-318, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36115443

RESUMO

BACKGROUND: Body surface area (BSA) has been reported to be the stronger predictor for prognosis than body mass index in heart failure (HF) patients. The sex-specific association of BSA with mortality has been unclear. METHODS: EuroSMR, a European multicenter registry, included patients who underwent edge-to-edge repair (TEER) for secondary mitral regurgitation (SMR). The outcome was two-year all-cause mortality. RESULTS: The present cohort included 1594 HF patients (age, 74 ± 10 years; male, 66%). Association of calculated BSA with two-year all-cause mortality was evaluated. Patients were classified into three BSA groups: the lowest 10% (S), the highest 10% (L), and intermediate between S and L (M). Mean BSA was 1.87 ± 0.21 m2 (male, 1.94 ± 0.18 m2; female, 1.73 ± 0.18 m2). The association of BSA with the endpoint in females showed a U-shaped curve, indicating worse prognosis for both S and L. The association in males followed a linear regression, demonstrating better prognosis for L. Hazard ratio (HR) of L to S in males was 0.43 (95% confidence interval [CI], 0.25-0.74; p = 0.002), whereas HR of L to M in females was 1.76 (95% CI, 1.11-2.78; p = 0.016) (p for interaction = 0.003). CONCLUSIONS: Sex-specific association patterns demonstrate the complex influence of anthropomorphic factors in HF patients scheduled for TEER. Further investigation beyond simple evaluation of weight and height is needed for better comprehension of the obesity paradox and better prediction of the results of transcatheter therapy in HF patients.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/métodos , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia
14.
JACC Cardiovasc Interv ; 15(24): 2541-2551, 2022 12 26.
Artigo em Inglês | MEDLINE | ID: mdl-36543448

RESUMO

BACKGROUND: In addition to the edge-to-edge MitraClip repair system, the edge-to-spacer PASCAL repair system was approved for percutaneous treatment of severe mitral regurgitation (MR). Comparative data are lacking. OBJECTIVES: The aim of this study was to compare procedural and short-term safety and efficacy of 2 leaflet-based transcatheter mitral valve repair systems. METHODS: Procedural and 30-day outcomes were investigated in a propensity score-matched cohort of 307 PASCAL and 307 MitraClip patients at 10 sites. Matching criteria included sex, age, left ventricular ejection fraction, New York Heart Association functional class, MR etiology, left ventricular end-diastolic diameter, left atrial volume index, and vena contracta width. The primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE). RESULTS: Technical success was 97.0% in the PASCAL group and 98.0% in the MitraClip group (P = 0.624). MR ≤2+ at discharge was comparable in both groups (PASCAL: 93.8% vs MitraClip: 92.4%; P = 0.527), with more patients exhibiting MR ≤1+ in the PASCAL group (70.5% vs 56.6%; P < 0.001). The postprocedural mean gradient was significantly higher in the MitraClip group (3.3 ± 1.5 mm Hg vs 3.9 ± 1.7 mm Hg; P < 0.001). At 30 days, all-cause mortality and MAE rates were similar (mortality: 1.7% vs 3.3%; P = 0.299; MAE: 3.9% vs 5.2%; P = 0.562). CONCLUSIONS: In this first large propensity score-matched comparison, procedural success rates and MAE did not differ significantly between patients treated with the PASCAL or MitraClip valve repair system. Procedural results with less than moderate MR and no elevated transmitral gradient were more common in the PASCAL group, which might have an impact on long-term outcome.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Volume Sistólico , Pontuação de Propensão , Função Ventricular Esquerda , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos
16.
Clin Cardiol ; 45(12): 1236-1245, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36070481

RESUMO

BACKGROUND: The number of MitraClip® implantations increased significantly in recent years. Data regarding the impact of weight class on survival are sparse. HYPOTHESIS: We hypothesized that weight class influences survival of patients treated with MitraClip® implantation. METHODS: We investigated in-hospital, 1-year, 3-year, and long-term survival of patients successfully treated with isolated MitraClip® implantation for mitral valve regurgitation (MR) (June 2010-March 2018). Patients were categorized by weight classes, and the impact of weight classes on survival was analyzed. RESULTS: Of 617 patients (aged 79.2 years; 47.3% females) treated with MitraClip® implantation (June 2010-March 2018), 12 patients were underweight (2.2%), 220 normal weight (40.1%), 237 overweight (43.2%), and 64 obesity class I (11.7%), 12 class II (2.2%), and 4 class III (0.7%). Preprocedural Logistic EuroScore (21.1 points [IQR 14.0-37.1]; 26.0 [18.5-38.5]; 26.0 [18.4-39.9]; 24.8 [16.8-33.8]; 33.0 [25.9-49.2]; 31.6 [13.1-47.6]; p = .291) was comparable between groups. Weight class had no impact on in-hospital death (0.0%; 4.1%; 1.5%; 0.0%; 7.7%; 0.0%; p = .189), 1-year survival (75.0%; 72.0%; 76.9%; 75.0%; 75.0%; 33.3%; p = .542), and 3-year survival (40.0%; 36.8%; 38.2%; 48.6%; 20.0%; 33.3%; p = .661). Compared to normal weight, underweight (hazard ratio [HR]: 1.35 [95% confidence interval [CI]: 0.65-2.79], p = .419), obesity-class I (HR: 0.93 [95% CI: 0.65-1.34], p = .705), class II (HR: 0.39 [95% CI: 0.12-1.24], p = .112), and class III (HR: 1.28 [95% CI: 0.32-5.21], p = .726) did not affect long-term survival. In contrast, overweight was associated with better survival (HR: 1.32 [95% CI: 1.04-1.68], p = .023). CONCLUSION: Overweight affected the long-term survival of patients undergoing MitraClip® implantation beneficially compared to normal weight.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Feminino , Humanos , Masculino , Magreza/complicações , Mortalidade Hospitalar , Sobrepeso/complicações , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Obesidade/complicações , Cateterismo Cardíaco/efeitos adversos
17.
JACC Cardiovasc Interv ; 15(17): 1723-1730, 2022 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-36075643

RESUMO

BACKGROUND: Although transcatheter edge-to-edge repair (TEER) has been shown to improve clinical outcomes and improve quality of life in patients with symptomatic secondary mitral regurgitation (SMR) and left ventricular dysfunction, its effect in patients with atrial SMR (aSMR) has not been well described. OBJECTIVES: The aim of this study was to assess the safety, echocardiographic outcomes, and clinical effectiveness of TEER for aSMR. METHODS: Patients with aSMR in the prospective, observational, multicenter EXPAND (A Contemporary, Prospective, Multi-Center Study Evaluating Real-World Experience of Performance and Safety for the Next Generation of MitraClip Devices) study were identified by an echocardiography core laboratory. Follow-up occurred at discharge, 30 days, and 1 year. Key endpoints included mitral regurgitation (MR) severity, functional class, heart failure hospitalizations, mortality, and 30-day major adverse events. RESULTS: Among 1,041 patients enrolled in EXPAND, 835 patients had evaluable echocardiograms at baseline. Of these, 53 patients had aSMR and 360 had ventricular SMR (vSMR). In the aSMR cohort, TEER resulted in a significant reduction in MR through 1 year (MR grade ≤2 in 100.0%), significantly increased 1-year Kansas City Cardiomyopathy Questionnaire score (+26.6 ± 30.5 points; P < 0.0001), and improved functional class from baseline, similar to the effects among patients with vSMR (MR grade ≤2 in 99.5% at 1 year, 1-year increase in Kansas City Cardiomyopathy Questionnaire score 21.23 ± 24.92 points). Major adverse events at 30 days and leaflet adverse events at 1 year were infrequent in both groups. CONCLUSIONS: In a prospective, real-world, global registry, TEER for aSMR was associated with significant MR reduction and improvement in quality of life and functional class, similar to patients with vSMR. This suggests that TEER may provide clinical benefit in patients with atrial fibrillation with SMR in the setting of heart failure with preserved ejection fraction. (The MitraClip® EXPAND Study of the Next Generation of MitraClip® Devices; NCT03502811).


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Cardiomiopatias/complicações , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento
18.
Eur J Heart Fail ; 24(11): 2162-2171, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36054557

RESUMO

AIMS: Right ventricular dysfunction (RVD), as expressed by right ventricular to pulmonary artery coupling, has recently been identified as a strong outcome predictor in patients undergoing mitral valve edge-to-edge repair (M-TEER) for secondary mitral regurgitation (MR). The aim of this study was to define RVD in patients undergoing M-TEER for primary MR (PMR) and to evaluate its impact on procedural MR reduction, symptomatic development and 2-year all-cause mortality. METHODS AND RESULTS: This multicentre study included patients undergoing M-TEER for symptomatic PMR at nine international centres. The study cohort was divided into a derivation (DC) and validation cohort (VC) for calculation and validation of the best discriminatory value for RVD. A total of 648 PMR patients were included in the study. DC and VC were comparable regarding procedural success and outcomes at follow-up. Sensitivity analysis identified RVD as an independent predictor for 2-year mortality in the DC (hazard ratio [HR] 2.37, 95% confidence interval [CI] 1.47-3.81, p < 0.001), which was confirmed in the VC (HR 2.06, 95% CI 1.36-3.13, p < 0.001). Procedural success (MR ≤2+) and symptomatic improvement at follow-up (New York Heart Association [NYHA] class ≤II) were lower in PMR patients with RVD (MR ≤2+: 82% vs. 93%, p = 0.002; NYHA class ≤II: 57.3% vs. 66.5%, p = 0.09 for with vs. without RVD). In all PMR patients, the presence of RVD significantly impaired 2-year survival after M-TEER (HR 2.23, 95% CI 1.63-3.05, p < 0.001). CONCLUSIONS: Mitral valve edge-to-edge repair is an effective treatment option for PMR patients. The presence of RVD is associated with less MR reduction, less symptomatic improvement and increased 2-year mortality. Accordingly, RVD might be included into pre-procedural prognostic considerations.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Direita , Humanos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia
20.
Diagnostics (Basel) ; 12(7)2022 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-35885559

RESUMO

BACKGROUND: The area of the left ventricular outflow tract (ALVOT) represents a major component of the continuity equation (CE), which is, i.a., crucial to calculate the aortic valve (AV) area (AAV). The ALVOT is typically calculated using 2D echo assessments as the measured anterior-posterior (a/p) extension, assuming a round LVOT base. Anatomically, however, usually an elliptical shape of the LVOT base is present, with the long diameter extending from the medial-lateral axis (m/l), which is not recognized by two-dimensional (2D) echocardiography. OBJECTIVE: We aimed to compare standard and three-dimensional (3D)-echocardiography-derived ALVOT calculation and its use in a standard CE (CEstd) and a modified CE (CEmod) to calculate the AAV vs. computed tomography (CT) multi-planar reconstruction (MPR) measurements of the anatomical ALVOT, and AAV, respectively. METHODS: Patients were selected if 3D transthoracic echocardiography (TTE), 3D transesophageal echocardiography (TEE), and cardiac CT were all performed, and imaging quality was adequate. The ALVOT was assessed using 2D calculation, (a/p only), 3D-volume MPR, and 3D-biplane calculation (a/p and m/l). AAV was measured using both CEstd and CEmod, and 3D-volume MPR. Data were compared to corresponding CT analyses. RESULTS: From 2017 to 2018, 107 consecutive patients with complete and adequate imaging data were included. The calculated ALVOT was smaller when assessed by 2D- compared to both 3D-volume MPR and 3D-biplane calculation. Calculated AAV was correspondingly smaller in CEstd compared to CEmod or 3D-volume MPR. The ALVOT and AAV, using data from 3D echocardiography, highly correlated and were congruent with corresponding measurements in CT. CONCLUSION: Due to the elliptic shape of the LVOT, use of measurements and calculations based on 2D echocardiography systematically underestimates the ALVOT and dependent areas, such as the AAV. Anatomically correct assessment can be achieved using 3D echocardiography and adapted calculations, such as CEmod.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...