Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Strength Cond Res ; 27(4): 1067-73, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22692109

RESUMO

The purpose of this study was to determine if wearing graduated compression tights, compared with loose fitting running shorts, would increase and or help sustain counter movement jump (CMJ) height after submaximal running. Fourteen competitive runners (6 women and 8 men) participated in this study. The subjects' mean (±SD) for age, height, body mass, percent body fat, resting heart rate, and maximal heart rate were 28.2 ± 14.0 years, 174.7 ± 8.6 cm, 70.2 ± 14.9 kg, 15.5 ± 8.1%, 67.2 ± 7.4 b.min, and 186.5 ± 9.5 b.min, respectively. During testing, subjects wore a Polar RS400 heart rate monitor. Each trial consisted of 15 minutes of continual treadmill running with 5 minutes performed at 50%, 70%, and 85% of the subject's heart rate reserve. Using a Vertec vertical leaper, each subject performed 3 CMJ, both pre- and postrun trials, with the mean value used to measure relative leg power. In addition to the CMJ height data, each subject rated their level of perceived exertion (RPE), and their comfort level, after the postrun trials. The mean postrun CMJ height in graduated compression tights of 60.3 ± 19.4 cm was significantly greater (at the p < 0.05 level) than both the prerun with tights of 57.7 ± 19.4 cm (4.5% increase) and the postrun running shorts of 57.7 ± 19.6 cm (4.5% increase). In addition, the subjects reported a significantly lower level of perceived exertion and greater comfort values while wearing the graduated compression tights. The results of the present study support the use of graduated compression tights for maintenance of lower limb muscle power after submaximal endurance running.


Assuntos
Vestuário , Movimento/fisiologia , Equipamentos Esportivos , Adolescente , Adulto , Teste de Esforço , Feminino , Frequência Cardíaca , Humanos , Extremidade Inferior , Masculino , Força Muscular , Músculo Esquelético/fisiologia , Esforço Físico , Corrida/fisiologia , Análise e Desempenho de Tarefas , Adulto Jovem
2.
J Exp Zool A Ecol Genet Physiol ; 313(1): 45-57, 2010 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-19768738

RESUMO

Felids have a wide range of locomotor activity patterns and maximal running speeds, including the very fast cheetah (Acinonyx jubatas), the roaming tiger (Panthera tigris), and the relatively sedentary domestic cat (Felis catus). As previous studies have suggested a relationship between the amount and type of activity and the myosin heavy chain (MHC) isoform composition of a muscle, we assessed the MHC isoform composition of selected hindlimb muscles from these three felid species with differing activity regimens. Using gel electrophoresis, western blotting, histochemistry, and immunohistochemistry with MHC isoform-specific antibodies, we compared the MHC composition in the tibialis anterior, medial gastrocnemius (MG), plantaris (Plt), and soleus muscles of the tiger, cheetah, and domestic cat. The soleus muscle was absent in the cheetah. At least one slow (type I) and three fast (types IIa, IIx, and IIb) MHC isoforms were present in the muscles of each felid. The tiger had a high combined percentage of the characteristically slower isoforms (MHCs I and IIa) in the MG (62%) and the Plt (86%), whereas these percentages were relatively low in the MG (44%) and Plt (55%) of the cheetah. In general, the MHC isoform characteristics of the hindlimb muscles matched the daily activity patterns of these felids: the tiger has daily demands for covering long distances, whereas the cheetah has requirements for speed and power.


Assuntos
Acinonyx/anatomia & histologia , Músculo Esquelético/química , Cadeias Pesadas de Miosina/análise , Tigres/anatomia & histologia , Acinonyx/fisiologia , Animais , Western Blotting , Gatos , Eletroforese em Gel de Poliacrilamida , Membro Posterior , Isoanticorpos/imunologia , Camundongos/anatomia & histologia , Camundongos/fisiologia , Músculo Esquelético/anatomia & histologia , Isoformas de Proteínas/análise , Tigres/fisiologia
3.
J Strength Cond Res ; 21(2): 506-9, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17530978

RESUMO

The purpose of this study was to compare abdominal muscle activity while performing a crunch on a stability ball with a traditional crunch. Forty-one healthy adults (23 men and 18 women) participated in the study. The subjects performed the crunch with the ball in 2 positions, 1 with the ball at the level of the inferior angles of the scapula (SB-high) and 1 with the ball at the level of the lower lumbar region of the back (SB-low). Surface electromyography was recorded from the upper and lower portions of the rectus abdominis and the external oblique during each repetition. Electromyography values were analyzed using repeated measures analyses of variance and pair-wise comparisons. Muscle activity for the upper and lower portions of the rectus abdominis and external oblique for a traditional crunch was significantly lower than for the crunch performed in the SB-low position but significantly greater than the SB-high position. Our data also showed that, on average, the abdominal muscle activity doubled when the stability ball was moved from the upper to the lower back position. These results support previous findings that a stability ball is not only effective for training the abdominal musculature, but, with the correct placement, it can also significantly increase muscle activity when compared with a traditional crunch. In addition, our results suggest that ball placement is critical for matching the appropriate overload to the condition level of the user.


Assuntos
Eletromiografia , Exercício Físico/fisiologia , Contração Muscular/fisiologia , Músculo Esquelético/fisiologia , Reto do Abdome/fisiologia , Adulto , Análise de Variância , Fenômenos Biomecânicos , Feminino , Humanos , Masculino
4.
J Strength Cond Res ; 19(1): 157-62, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15705027

RESUMO

The present study compared the muscle activity elicited by selected abdominal training devices with muscle activity elicited by a traditional crunch. Forty-six adults participated in the study. The exercise devices tested included the Ab-ONE, Perfect Abs Roller, Ab Scissor, Ab Swing, 6SecondAbs, and the Torso Track. For those devices with variable resistances, all were tested at their high resistance setting. Surface electromyography (EMG) was recorded from the upper and lower portions of the rectus abdominis and the external oblique during each repetition. EMG values were analyzed using repeated measures analyses of variance (ANOVA) and pairwise comparisons. EMG measurements for each abdominal muscle analyzed were highly reliable and differed significantly across the exercises tested. Muscle activity for the upper and lower portions of the rectus abdominis for a normal crunch was lower than for the Ab-ONE, the same as for the Perfect Abs Roller, and higher than for the Ab Scissor, Ab Swing, 6SecondAbs, and Torso Track. External oblique muscle activity for a traditional crunch was higher than for the Perfect Abs Roller and did not differ from the other devices. These results support previous findings that portable abdominal devices are most effective if they not only mimic the mechanics of a traditional crunch, but also provide external resistance to increase involvement of the abdominal musculature.


Assuntos
Músculos Abdominais/fisiologia , Terapia por Exercício/instrumentação , Exercício Físico/fisiologia , Contração Muscular/fisiologia , Adulto , Eletromiografia , Desenho de Equipamento , Feminino , Humanos , Masculino , Recrutamento Neurofisiológico
5.
J Strength Cond Res ; 17(3): 463-8, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12930170

RESUMO

The purpose of this study was to compare the abdominal muscle activity elicited while using 4 portable abdominal training devices vs. a traditional crunch. Thirty-three adults participated in this study. The exercise devices tested included the Ab Roller Plus, Torso Track 2, AB-DOer Pro, and the Perfect Abs. All subjects were tested on the Perfect Abs in both a seated and supine position using low-, medium-, and high-resistance bands. The Torso Track 2 was also tested at low- and high-resistance settings. Surface electromyography (EMG) was recorded from the upper and lower portions of the rectus abdominis, external oblique, and the rectus femoris during each repetition. Statistical analyses were performed on the mean EMG values using a repeated analysis of variance (ANOVA) procedure. There was no significant difference in abdominal muscle activity between the Ab Roller Plus, the Torso Track 2 (high resistance), and a traditional crunch. The mean abdominal muscle activity was significantly lower than a normal crunch, however, when using the AB-DOer, Torso Track (low resistance), and the Perfect Abs seated with the low-resistance band. In contrast, the Perfect Abs, when used in the supine position with the medium- and high-resistance bands, elicited significantly greater mean abdominal muscle activity than a crunch. Of the 4 devices tested, only the Perfect Abs when used in the supine position with the medium- and high-resistance bands, elicited more abdominal activity than a crunch. The results suggest that portable abdominal devices are most effective if they not only mimic the mechanics of a traditional crunch, but also provide external resistance to increase the involvement of the abdominal musculature.


Assuntos
Músculos Abdominais/fisiologia , Eletromiografia , Exercício Físico/fisiologia , Contração Muscular , Adulto , Análise de Variância , Fenômenos Biomecânicos , Feminino , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA