Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Med Chem ; 47(1): 615-8, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22093760

RESUMO

1-Hydroxybisphosphonate derivatives of ciprofloxacin, gatifloxacin and moxifloxacin have been synthesized using Cu(I) catalyzed azide-alkyne 1,3-dipolar cycloaddition reaction. The 1,2,3-triazol linked hydroxybisphosphonate derivative of ciprofloxacin exhibited antibacterial activity comparable to the parent antibiotic and all fluoroquinolone-bisphosphonates displayed osteotropic properties in a bone model.


Assuntos
Antibacterianos/síntese química , Antibacterianos/farmacologia , Fluoroquinolonas/síntese química , Fluoroquinolonas/farmacologia , Organofosfonatos/química , Adsorção , Antibacterianos/química , Antibacterianos/metabolismo , Bactérias/efeitos dos fármacos , Osso e Ossos/efeitos dos fármacos , Osso e Ossos/metabolismo , Durapatita/química , Durapatita/metabolismo , Fluoroquinolonas/química , Fluoroquinolonas/metabolismo , Nanoestruturas
2.
Comp Med ; 58(4): 369-74, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18724779

RESUMO

The multfactorial nature of bone injuries in modern warfare and emergency trauma patients warrants enhancement of existing models. To develop a more appropriate model, rat tibiae (n = 195) were mechanically injured, divided into 2 groups (with or without thermal injury), and contaminated with a range of Staphylococcus aureus (Cowan 1) inocula. In some experiments, S. aureus inocula also contained Escherichia coli or foreign bodies (sand or soil). The primary outcome measure was the amount of S. aureus remaining in the tibia (tibial bacterial load) 24 h after contamination, reported as log10 cfu/g bone. S. aureus showed ID50 and ID95 values of 72 and 977 cfu, respectively. Values were lower than seen previously by using S. aureus strain SMH. S. aureus tibial bacterial loads were higher in tibiae with mechanical and thermal injury (log10 4.15 +/- 0.27 cfu/g) versus mechanical injury alone (log10 3.1 +/- 0.47 cfu/g, P = 0.028). The addition of E. coli to the S. aureus inoculum had no effect on tibial bacterial loads (S. aureus only, log10 4.24 +/- 0.92 cfu/g; S. aureus + E. coli, log10 4.1 +/- 1.0 cfu/g, P = 0.74). Sand, added as a foreign body, increased tibial bacterial load. Combined mechanical and thermal trauma of the tibia is associated with increased S. aureus tibial bacterial loads, increasing the risk of acute osteomyelitis. Understanding the interplay of mechanical and thermal injuries, bimicrobial contamination, and foreign bodies may improve our understanding of traumatic bone injuries and the pathogenesis of osteomyelitis.


Assuntos
Modelos Animais de Doenças , Corpos Estranhos , Osteomielite , Dióxido de Silício , Infecções Estafilocócicas , Tíbia , Fraturas da Tíbia , Animais , Escherichia coli , Consolidação da Fratura , Fraturas Expostas/complicações , Fraturas Expostas/microbiologia , Temperatura Alta , Humanos , Masculino , Osteomielite/microbiologia , Osteomielite/patologia , Ratos , Ratos Sprague-Dawley , Staphylococcus aureus , Tíbia/microbiologia , Tíbia/patologia , Fraturas da Tíbia/complicações , Fraturas da Tíbia/microbiologia , Infecção dos Ferimentos
3.
J Endod ; 34(4): 463-5, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18358898

RESUMO

This study compared the taper variation among Profile, Guidance, and EndoSequence 0.06 tapered rotary files to current standards. Fifteen files of sizes 35, 40, and 45 from each manufacturer were evaluated for a total of 135 files. A digital image of the first 4 mm of each file was captured with light microscope at 22x, calibrated for 0.001-mm accuracy, and analyzed. The diameter of each file was measured at 1 and 4 mm, and the taper was calculated. Of the 3 file systems, 100% of the Profile files, 97.8% of the Guidance files, and 86.7% of the EndoSequence files fell within +/-0.02 taper. All file systems demonstrated variability within their groups. A series of chi(2) analyses indicated that manufacturers tend to produce Guidance and Profile tapers slightly under the ideal 0.06 taper (P < .05). The tapers of EndoSequence files were just as likely to be over or under the advertised 0.06 taper (P > .05).


Assuntos
Instrumentos Odontológicos/normas , Preparo de Canal Radicular/instrumentação , Ligas Dentárias , Desenho de Equipamento , Níquel , Titânio
4.
J Oral Maxillofac Surg ; 64(4): 589-93, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16546637

RESUMO

PURPOSE: The purpose of this study was to evaluate the effect of hyperbaric oxygen therapy on bone regeneration during distraction of irradiated rabbit mandibles. MATERIALS AND METHODS: Twenty New Zealand white rabbits were randomly sub-divided into 4 groups. Group 1 served as control, group 2 received preoperative radiation therapy, group 3 received pre- and postoperative hyperbaric oxygen (HBO) therapy, and group 4 received preoperative radiation therapy and pre- and postoperative HBO therapy. All rabbits underwent a corticotomy of the left body of the mandible after placement of a distraction device. Distraction, at a rate of 1 mm/day and a rhythm of 1 turn/day, began after a 3-day latency period for 14 days. Thirty days after completion of the distraction protocol, the animals were euthanized, and histomorphometric and radiographic data of the distraction segments were obtained. RESULTS: Histomorphometric analysis of new bone fill was greatest in the non-irradiated groups compared to groups receiving radiation therapy, regardless of HBO therapy (P = .03). Pre-corticotomy bone density measurements showed a significant increase in bone density over time (P = .0007). This resulted in a significant relationship between HBO therapy, radiation therapy, and time (P = .0050). CONCLUSIONS: The results of the study support the use of HBO therapy during distraction osteogenesis. Any additional therapeutic benefit of HBO therapy in irradiated bone would require additional investigation.


Assuntos
Regeneração Óssea/fisiologia , Irradiação Craniana/efeitos adversos , Oxigenoterapia Hiperbárica , Mandíbula/cirurgia , Osteogênese por Distração , Análise de Variância , Animais , Densidade Óssea , Mandíbula/efeitos da radiação , Procedimentos Cirúrgicos Bucais , Coelhos , Lesões por Radiação/etiologia , Lesões por Radiação/terapia , Distribuição Aleatória
5.
J Endod ; 32(3): 222-4, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16500231

RESUMO

The purpose of this study was to measure and compare the amount of stress produced by GT ProFile (GT) and ProFile (PF) rotary files lubricated with either RC Prep (RCP) or saline (S) on the walls of prepared simulated canals. Twenty-four 10-mm long canals with a 10 mm radius of curvature were prepared in PL-2 photoelastic acrylic blocks which were lubricated with either RCP or S. The files were inserted into a Nouvag handpiece mounted to an Instron 4502 universal testing machine and lowered into the canal at a rate of 60 mm/min and a rotational speed of 300 RPM. The following four GTs and four PFs were sequentially introduced into predetermined depths of each canal: 20/.10, 20/.08, 20/.06, 20/.04, 40/.04, 35/.04, 30/.04, and 25/.04. Total areas of stress created by each file were captured by digital video images and measured using Image J software. Statistical analysis of the data was performed using a two-way ANOVA (p < 0.05, n = 24). The GT/RCP group demonstrated a significant average of 64.22% less stress than GT/S group. The PF (25, 30, and 35)/RCP groups demonstrated a significant average of 27.02% less stress than the same S groups. PF (40) produced a negligible amount of stress regardless of the lubricant type. The results reveal that using RCP as a lubricant when instrumenting curved canals with GT and PF results in less stress when compared to saline.


Assuntos
Instrumentos Odontológicos , Análise do Estresse Dentário , Ácido Edético , Peróxidos , Preparo de Canal Radicular/instrumentação , Ureia , Ceras , Resinas Acrílicas , Análise de Variância , Cavidade Pulpar/fisiologia , Elasticidade , Falha de Equipamento , Lubrificação , Cloreto de Sódio , Estresse Mecânico , Torque
6.
Bone ; 37(6): 759-69, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16219496

RESUMO

Glucose-dependent insulinotropic polypeptide (GIP) is an incretin hormone, which is secreted from endocrine cells in the small intestine after meal ingestion. GIP has been shown to affect osteoblastic function in vitro; however, the in vivo effects of GIP on bone remodeling remain unclear. In the present study, we investigated the role of GIP in modulating bone turnover, by evaluating serum markers of bone turnover, bone density, bone morphology, and changes in biomechanical bone strength over time (one to five months) in GIP receptor knockout mice (GIPR-/- mice). The GIPR-/- mice showed a decreased bone size, lower bone mass, altered bone microarchitecture and biomechanical properties, and altered parameters for bone turnover, especially in bone formation. Moreover, the effects of GIP on bone mass were site-specific and compensatory mechanism developed over time and ameliorated the impact of the loss of GIP signaling on bone mass. Further, GIPR-/- mice had earlier age-related changes than wild-type mice in body composition, including bone mass, lean body mass, and fat percentage. In summary, our results indicate that GIP has an anabolic effect on bone mass and bone quality and suggests that GIP may be a hormonal link between nutrient ingestion and utilization.


Assuntos
Remodelação Óssea , Osso e Ossos/metabolismo , Receptores dos Hormônios Gastrointestinais/genética , Absorciometria de Fóton , Animais , Biomarcadores/análise , Peso Corporal , Densidade Óssea , Osso e Ossos/química , Osso e Ossos/diagnóstico por imagem , Feminino , Imageamento Tridimensional , Camundongos , Camundongos Knockout
7.
J Endod ; 30(11): 775-7, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15505508

RESUMO

The purpose of this study was to compare the retentive strength of zinc-phosphate cement, glass-ionomer cement, and mineral trioxide aggregate (MTA) cement in the retention of prefabricated posts. The root canals of 60 bovine incisors were prepared and obturated with warm gutta-percha. Post space was prepared, the smear layer removed, and posts were luted with zinc-phosphate cement, glass-ionomer cement, or MTA. The specimens were stored at 37 degrees C and 100% humidity for 2 weeks, and then subjected to increasing axial tensile forces by an Instron machine until bond failure occurred. Data were analyzed by a one-way ANOVA and a Tukey-Kramer multiple comparison test. The retentive strengths of zinc phosphate and glass-ionomer cements were statistically equivalent, and significantly greater than MTA (p < 0.001), which suggests that zinc phosphate or glass-ionomer cement may be superior to MTA when used as luting agents for posts in endodontically treated teeth.


Assuntos
Compostos de Alumínio , Compostos de Cálcio , Colagem Dentária , Adesivos Dentinários , Combinação de Medicamentos , Óxidos , Técnica para Retentor Intrarradicular , Materiais Restauradores do Canal Radicular , Silicatos , Análise de Variância , Animais , Bovinos , Retenção em Prótese Dentária , Análise do Estresse Dentário , Cimentos de Ionômeros de Vidro , Teste de Materiais , Estatísticas não Paramétricas , Resistência à Tração , Cimento de Fosfato de Zinco
8.
Mil Med ; 169(12): 948-51, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15646183

RESUMO

This study compared the ability of various intracanal restorative materials to restore the stiffness of endodontically treated teeth. We randomly placed bovine central incisors into six groups. We did not instrument negative control teeth, and we instrumented, but did not restore, positive control teeth. We restored teeth in the experimental groups with resin-based composite, resin-based composite plus a fiberglass post, or resin-based composite plus a cemented metal post. We subjected all teeth to nondestructive, compressive testing and recorded the stiffness of each sample. Results indicated that performing endodontic access and instrumentation alone resulted in a 24% loss in tooth stiffness. Teeth restored using an intracanal resin bonding technique alone or in combination with a post regained the stiffness lost from access and instrumentation, and teeth that were restored with bonded resin and a metal post cemented with Panavia 21 cement were significantly stiffer than the untreated negative control group (p < 0.05). Our results suggest that intracanal resin bonding techniques may reduce the need for immediate crown placement after endodontic therapy.


Assuntos
Resinas Compostas/uso terapêutico , Coroas , Restauração Dentária Permanente/métodos , Endodontia/instrumentação , Incisivo/fisiologia , Materiais Restauradores do Canal Radicular/uso terapêutico , Tratamento do Canal Radicular/métodos , Fraturas dos Dentes/prevenção & controle , Animais , Bovinos , Restauração Dentária Permanente/instrumentação , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Incisivo/cirurgia , Teste de Materiais , Tratamento do Canal Radicular/instrumentação
9.
J Endod ; 29(3): 184-6, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12669877

RESUMO

The purpose of this study was to determine the efficacy of several milk substitutes compared to whole milk in maintaining the viability of human periodontal ligament (PDL) cells on avulsed teeth. PDL cells were obtained from freshly extracted, healthy third molars and cultured in Eagle's minimal essential media (EMEM). The cells were plated onto 24-well culture plates and allowed to attach for 24 h. EMEM was replaced with refrigerated whole milk (positive control), reconstituted powdered milk, evaporated milk, or one of two baby formulas (Similac or Enfamil). Tap water served as the negative control. Tissue culture plates were incubated with the experimental media at 37 degrees C for 1, 2, 4, or 8 h. Cell viability was determined by a cell proliferation assay (CellTiter 96 AQ Assay), with absorbance read at 450 nM. A two-way ANOVA (p < 0.001) indicated that at 1 h there was no difference in the effect on PDL cell viability between any of the materials and whole milk. At 2 h, Enfamil and Similac performed significantly better than whole milk, whereas evaporated milk performed worse. At 4 h, Enfamil performed better than whole milk, whereas all other milk substitutes performed worse. At 8 h, all substitutes performed worse than whole milk. These results suggest that Enfamil, which is supplied in powder form that does not require special storage and has a shelf life of 18 months, is a more effective storage medium for avulsed teeth than pasteurized milk for at least 4 h.


Assuntos
Leite/fisiologia , Soluções para Preservação de Órgãos/farmacologia , Ligamento Periodontal/efeitos dos fármacos , Análise de Variância , Animais , Dente Pré-Molar/patologia , Divisão Celular/efeitos dos fármacos , Sobrevivência Celular , Células Cultivadas , Meios de Cultura , Fibroblastos/efeitos dos fármacos , Fibroblastos/patologia , Humanos , Concentração de Íons de Hidrogênio , Leite/classificação , Dente Serotino/patologia , Concentração Osmolar , Ligamento Periodontal/citologia , Temperatura , Fatores de Tempo , Avulsão Dentária/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...