Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Orthop ; 2024: 6471544, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38845777

RESUMO

Introduction: Olecranon fractures are common injuries that require surgical intervention for optimal outcomes. Various fixation methods have been described in the literature, including the use of intramedullary proximal ulna screws in combination with tension band augmentation. Limited research has compared this hybrid technique to other established methods of fixation. This study compared complication and reoperation rates between multiple groups. Methods: A retrospective review was conducted on patients with olecranon fractures who underwent internal fixation at a level 1 trauma center between January 1st, 2013, and April 22nd, 2023. Data was collected using CPT codes, and patients were categorized into five groups based on the method of fixation received: no implant, tension band only, locking olecranon plate, intramedullary screw and tension band hybrid, and others. Variables such as patient demographics, Mayo fracture classification, open vs. closed injury, implant type, reoperation rates, and postoperative complications were recorded. Results: A total of 217 patients were included in the study. No difference was found with implant choice and reoperation rate (p = 0.461). There was a significant difference found with reoperation and fracture type (p = 0.027) and open fracture (p = 0.002). Conclusion: The primary findings of this study indicate no significant difference in implant choice and reoperation rates among the various fixation methods used for olecranon fractures. These findings suggest that the hybrid fixation technique, utilizing intramedullary proximal ulna screws in combination with tension band augmentation, is a viable and comparable treatment option when evaluated against other well-documented methods of fixation. This study also reiterates that severity of initial injury is often the most important factor related to poorer outcomes. Further discussion and analysis of the data will provide a comprehensive understanding of implications and recommendations for olecranon fracture fixation.

2.
J Surg Case Rep ; 2024(2): rjae043, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38328456

RESUMO

An unhelmeted 59-year-old male involved in a motorcycle accident presented with a right dorsal lunate dislocation in the context of a polytrauma evaluation. Soft-tissue attachments were minimal across the carpus, which allowed for an en bloc proximal row carpectomy. Two-year follow-up yielded a satisfactory outcome given the high energy injury mechanism. Proximal row carpectomy is a useful tool which preserves wrist range of motion in the acute trauma setting and is durable, as demonstrated by our patient's postoperative mobilization using a wheelchair.

3.
BMC Musculoskelet Disord ; 24(1): 749, 2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37737167

RESUMO

BACKGROUND: The femoral neck system (FNS) is commonly used for internal fixation of femoral neck fractures and has shown promising results. However, we have observed cases of peri-implant subtrochanteric femur fractures associated with the use of FNS at our institution. This case series aims to investigate four cases of peri-implant subtrochanteric fractures in patients treated with the FNS implant for femoral neck fractures. CASE PRESENTATION: We reviewed 35 patients who underwent treatment with FNS for femoral neck fractures between January 2017 and December 2021 at our level 1 trauma institution. Among these patients, four cases of peri-implant subtrochanteric femur fractures were identified. In contrast, no such fractures occurred in patients treated with cannulated screws or dynamic hip screws (DHS). Interestingly, all four cases of peri-implant fractures were seen in patients with incomplete nondisplaced femoral neck fractures. Only one case involved an identifiable technical error. CONCLUSIONS: This case series sheds light on peri-implant subtrochanteric femur fractures as a previously unreported complication associated with the use of FNS for femoral neck fractures. These fractures were observed exclusively in patients with incomplete nondisplaced fractures who received FNS fixation. No similar complications were observed in patients treated with other types of fixation. This finding suggests the need for caution and further investigation when considering FNS as a treatment option for this specific fracture pattern. The identification of peri-implant subtrochanteric femur fractures as a potential complication of FNS usage in incomplete nondisplaced femoral neck fractures raises important considerations for clinical decision-making and patient management in orthopedic trauma.


Assuntos
Fraturas do Colo Femoral , Fraturas do Quadril , Humanos , Tomada de Decisão Clínica , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/etiologia , Fraturas do Colo Femoral/cirurgia , Fêmur , Colo do Fêmur , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/etiologia , Fraturas do Quadril/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA