1.
J Clin Med ; 13(9)2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38731236

RESUMO

The implantation of cardiac electronic devices (CIEDs), including pacemakers and defibrillators, has become increasingly prevalent in recent years and has been accompanied by a significant rise in cardiac device infections (CDIs), which pose a substantial clinical and economic burden. CDIs are associated with hospitalizations and prolonged antibiotic therapy and often necessitate device removal, leading to increased morbidity, mortality, and healthcare costs worldwide. Approximately 1-2% of CIED implants are associated with infections, making this a critical issue to address. In this contemporary review, we discuss the burden of CDIs with their risk factors, healthcare costs, prevention strategies, and clinical management.

3.
J Cardiovasc Electrophysiol ; 35(3): 379-388, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38185855

RESUMO

BACKGROUND: The mechanism of typical slow-fast atrioventricular nodal re-entrant tachycardia (AVNRT) and its anatomical and electrophysiological circuit inside the right atrium (RA) and Koch's Triangle (KT) are not well known. OBJECTIVE: To identify the potentials of the compact AV node and inferior extensions and to perform accurate mapping of the RA and KT in sinus rhythm (SR) and during AVNRT, to define the tachycardia circuit. METHODS: Consecutive patients with typical AVNRT were enrolled in 12 Italian centers and underwent mapping and ablation by means of a basket catheter with small electrode spacing for ultrahigh-density mapping and a modified signal-filtering toolset to record the potentials of the AV nodal structures. RESULTS: Forty-five consecutive cases of successful ablation of typical slow-fast AVNRT were included. The mean SR cycle length (CL) was 784.1 ± 6 ms and the mean tachycardia CL was 361.2 ± 54 ms. The AV node potential had a significantly shorter duration and higher amplitude in sinus rhythm than during tachycardia (60 ± 40 ms vs. 160 ± 40 ms, p < .001 and 0.3 ± 0.2 mV vs. 0.09 ± 0.12 mV, p < .001, respectively). The nodal potential duration extension was 169.4 ± 31 ms, resulting in a time-window coverage of 47.6 ± 9%. The recording of AV nodal structure potentials enabled us to obtain 100% coverage of the tachycardia CL during slow-fast AVNRT. CONCLUSION: Detailed recording of the potentials of nodal structures is possible by means of multipolar catheters for ultrahigh-density mapping, allowing 100% of the AVNRT CL to be covered. These results also have clinical implications for the ablation of right-septal and para-septal arrhythmias.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Humanos , Nó Atrioventricular/cirurgia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Ablação por Cateter/métodos , Átrios do Coração , Eletrodos
4.
Heart Rhythm ; 20(4): 614-626, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36634901

RESUMO

Atrioventricular nodal reentrant tachycardia (AVNRT) is the most frequent regular tachycardia in humans. In this review, we describe the most recent discoveries regarding the anatomical, physiological, and molecular biological features of the atrioventricular junction that could underlie the typical slow-fast AVNRT mechanisms, as these insights could lead to the proposal of a new theory concerning the circuit of this arrhythmia. Despite several models have been proposed over the years, the precise anatomical site of the reentrant circuit and the pathway involved in the slow-fast AVNRT have not been conclusively defined. One possible way to evaluate all the hypotheses regarding the nodal tachycardia circuit in humans is to map this circuit. Thus, we tried to identify the slow potential of nodal and inferior extension structures by using automated mapping of atrial activation during both sinus rhythm and typical slow-fast AVNRT. This constitutes a first step toward the definition of nodal area activation in sinus rhythm and during slow-fast AVNRT. Further studies and technical improvements in recording the potentials of the atrioventricular node structures are necessary to confirm our initial results.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Supraventricular , Humanos , Nó Atrioventricular , Imunoquímica , Átrios do Coração , Ablação por Cateter/métodos
5.
Pacing Clin Electrophysiol ; 44(12): 2031-2040, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34606098

RESUMO

BACKGROUND: An early, comprehensive rhythm-control therapy is needed in order to treat atrial fibrillation (AF) effectively and to improve ablation outcomes. METHODS: A total of 153 consecutive patients from the CHARISMA registry undergoing AF ablation at eight centers were included. Patients with de novo PVI were classified as having undergone early treatment (ET) if the procedure was performed within 6 months after the first AF episode, and as having undergone delayed treatment (DT) if ablation was performed over 6 months after the first AF episode. RESULTS: One-hundred fifty-three patients were enrolled (69.9% male, 59 ± 10 years, 61.4% paroxysmal AF, 38.6% persistent AF). The time from the first AF episode to the ablation procedure was 1034 ± 1483 days. The ET group comprised 36 patients (25.3%), the DT group 60 (39.2%) and Redo cases were 57 (37.3%). During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/AT recurrence. More DT patients than ET patients suffered recurrences (15.7% vs. 2.2%, p = 0.0452) and the time to AT/AF recurrence was shorter in the group of patients who received an ablation treatment after 6 months (HR = 6.19, 95% CI: 1.7 to 21.9; p = 0.0474). On multivariate Cox analysis, only hypertension (HR = 4.86, 95% CI: 1.6 to 14.98, p = 0.0062) was independently associated with recurrences. Beyond the hypertension risk factor, ET was associated with a low risk of recurrence; recurrence rate ranged from 0% (ET patients without hypertension) to 25.0% (DT patients with hypertension). CONCLUSIONS: An early rhythm-control ablation therapy in the absence of common risk factors was associated with the lowest rate of recurrences.


Assuntos
Fibrilação Atrial/prevenção & controle , Fibrilação Atrial/cirurgia , Ablação por Cateter , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros
6.
J Cardiovasc Electrophysiol ; 32(6): 1540-1548, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33851484

RESUMO

BACKGROUND: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have recently emerged as a viable real-time indicator of tissue characteristics and durability of the lesions created. We report the outcomes of acute and long-term clinical evaluation of the new DirectSense algorithm in AF ablation. METHODS: Consecutive patients undergoing AF ablation were included in the CHARISMA registry. RF delivery was guided by the DirectSense algorithm, which records the magnitude and time-course of the impedance drop. The ablation endpoint was pulmonary vein isolation (PVI), as assessed by the entrance and exit block. RESULTS: 3556 point-by-point first-pass RF applications of >10 s duration were analyzed in 153 patients (mean age=59 ± 10 years, 70% men, 61% paroxysmal AF, 39% persistent AF). The mean baseline LI was 105 ± 15 Ω before ablation and 92 ± 12 Ω after ablation (p < .0001). Both absolute drops in LI and the time to LI drop (LI drop/τ) were greater at successful ablation sites (n = 3122, 88%) than at ineffective ablation sites (n = 434, 12%) (14 ± 8 Ω vs 6 ± 4 Ω, p < .0001 for LI; 0.73 [0.41-1.25] Ω/s vs. 0.35[0.22-0.59 Ω/s, p < .0001 for LI drop/τ). No major complications occurred during or after the procedures. All PVs had been successfully isolated. During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/atrial tachycardia recurrence after the 90-day blanking period. CONCLUSION: The magnitude and time-course of the LI drop during RF delivery were associated with effective lesion formation. This ablation strategy for PVI guided by LI technology proved safe and effective and resulted in a very low rate of AF recurrence over 1-year follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
7.
J Interv Card Electrophysiol ; 61(3): 487-497, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32766944

RESUMO

BACKGROUND: Atrial activation during typical atrioventricular nodal reentrant tachycardia (AVNRT) exhibits anatomic variability and spatially heterogeneous propagation inside the Koch's triangle (KT). The mechanism of the reentrant circuit has not been elucidated yet. Aim of this study is to describe the distribution of Jackman and Haïssaguerre potentials within the KT and to explore the activation mode of the KT, in sinus rhythm and during the slow-fast AVNRT. METHODS: Forty-five consecutive cases of successful slow pathway (SP) ablation of typical slow-fast AVNRT from the CHARISMA registry were included. RESULTS: The KT geometry was obtained on the basis of the electroanatomic information using the Rhythmia mapping system (Boston Scientific) (mean number of points acquired inside the KT = 277 ± 47, mean mapping time = 11.9 ± 4 min). The postero-septal regions bounded anteriorly by the tricuspid annulus and posteriorly by the lateral wall toward the crista terminalis showed a higher prevalence of Jackman potentials than mid-postero-septal regions along the tendon of Todaro and coronary sinus (CS) (98% vs. 16%, p < 0.0001). Haïssaguerre potentials seemed to have a converse distribution across the KT (0% vs. 84%, p < 0.0001). Fast pathway insertion, as located during AVNRT, was mostly recorded in an antero-septal position (n = 36, 80%), rather than in a mid-septal (n = 6, 13.3%) or even postero-septal (n = 3, 7%) location. During typical slow-fast AVNRT, two types of propagation around the CS were discernible: anterior and posterior, n = 31 (69%), or only anterior, n = 14 (31%). During the first procedure, the SP was eliminated, and acute procedural success was achieved (median of 4 [3-5] RF ablations). CONCLUSION: High-density mapping of KT in AVNRT patients both during sinus rhythm and during tachycardia provides new electrophysiological insights. A better understanding and a more precise definition of the arrhythmogenic substrate in AVNRT patients may have prognostic value, especially in high-risk cases. TRIAL REGISTRATION: Catheter Ablation of Arrhythmias With High Density Mapping System in the Real World Practice (CHARISMA) URL: http://clinicaltrials.gov/ Identifier: NCT03793998.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Ventricular , Fascículo Atrioventricular , Átrios do Coração , Humanos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia
8.
Clin Cardiol ; 42(10): 1041-1050, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31411347

RESUMO

Despite the technical improvements made in recent years, the overall long-term success rate of ventricular tachycardia (VT) ablation in patients with ischemic cardiomyopathy remains disappointing. This unsatisfactory situation has persisted even though several approaches to VT substrate ablation allow mapping and ablation of noninducible/nontolerated arrhythmias. The current substrate mapping methods present some shortcomings regarding the accurate definition of the true scar, the modality of detection in sinus rhythm of abnormal electrograms that identify sites of critical channels during VT and the possibility to determine the boundaries of functional re-entrant circuits during sinus or paced rhythms. In this review, we focus on current and proposed ablation strategies for VT to provide an overview of the potential/real application (and results) of several ablation approaches and future perspectives.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Isquemia Miocárdica/complicações , Taquicardia Ventricular/diagnóstico , Humanos , Isquemia Miocárdica/diagnóstico , Prognóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia
9.
Pacing Clin Electrophysiol ; 42(7): 1056-1062, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31116439

RESUMO

The mechanisms of atrial fibrillation (AF) induction and maintenance, including those involved in paroxysmal atrial fibrillation, are not completely known; this limits our ablation strategies and prevents us from understanding what we are actually doing when performing pulmonary vein isolation. In this report, we focus on the commonly used ablation strategies for AF and question the importance of complete pulmonary vein isolation in achieving lasting success in the ablation of AF. We also discuss in detail the absence of durable pulmonary vein isolation in patients without arrhythmic recurrences after AF ablation and the possibility to cure paroxysmal AF without concomitant pulmonary vein isolation, provocatively questioning the dogma of pulmonary vein isolation as the cornerstone of AF ablation. Finally, a prospective personalized approach in the individual patient is advocated.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Humanos , Medicina de Precisão , Recidiva
10.
Sensors (Basel) ; 14(7): 12114-26, 2014 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-25006995

RESUMO

We developed a multichannel system based on superconducting quantum interference devices (SQUIDs) for magnetoencephalography measurements. Our system consists of 163 fully-integrated SQUID magnetometers, 154 channels and 9 references, and all of the operations are performed inside a magnetically-shielded room. The system exhibits a magnetic field noise spectral density of approximatively 5 fT/Hz(1=2). The presented magnetoencephalography is the first system working in a clinical environment in Italy.


Assuntos
Condutometria/instrumentação , Magnetoencefalografia/instrumentação , Magnetometria/instrumentação , Transdutores , Condutividade Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
11.
J Atr Fibrillation ; 7(1): 1075, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-27957085

RESUMO

The discrimination between ventricular (VT) and supraventricular tachycardia (SVT) and the evaluation of their hemodynamic impact are essential issues in the arrhythmia management. A new pacing device features a tachycardia diagnostic system relying on simultaneous recording of the transvalvular impedance (TVI) and a special integrated electric signal derived by the whole set of endocardial electrodes (iECG). The iECG waveform is sensitive to the pattern of ventricular activation, similarly to the surface ECG. The TVI increases in systole and decreases in diastole and the amplitude of this cyclic fluctuation is an expression of the effectiveness of the pump function. In order to test the value of these signals in the analysis of a tachycardia, we have assessed the iECG and TVI modifications induced by different SVTs and tolerated and non-tolerated VTs, during electrophysiological (EP) studies. In case of SVT, the ventricular component of the iECG maintained the same morphology as in sinus rhythm. The peak-peak amplitude of the TVI fluctuation was reduced to 66 ± 11 % of the individual sinus rhythm reference, but the signal was present at every beat and showed a remarkable stability (variation coefficient 0.19 ± 0.01). In case of VT, the ventricular component of the iECG was strikingly different than in sinus rhythm. Regular TVI fluctuation was observed with tolerated VTs (peak-peak amplitude 74 ± 6 %; variation coefficient 0.21 ± 0.04). In contrast, with non-tolerated VTs the TVI amplitude was depressed below 40%, and the signal was virtually absent in the event of very fast VT or VF. Our results confirm that the iECG is a reliable tool to quickly discriminate VTs from SVTs and that TVI can provide information on the severity of the hemodynamic impairment produced by a tachycardia, with potential clinical benefit in the follow-up of pacemaker patients. Furthermore, the application of these signals to automatic algorithms of arrhythmia recognition might improve the specificity of therapy administration by an implantable defibrillator (ICD).

12.
Circ Arrhythm Electrophysiol ; 4(2): 225-34, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21372271

RESUMO

BACKGROUND: The presence of a conduction block at the level of the Koch triangle (KT) and the origin of the multicomponent potentials inside this area are controversial issues. We investigated the propagation of the sinus impulse into the KT and the characteristics of multicomponent potentials recorded in that area in patients with and without atrioventricular nodal reentrant tachycardia (AVNRT). METHODS AND RESULTS: Thirty-two patients (16 with AVNRT, 16 without AVNRT) underwent a sinus rhythm electroanatomic mapping of the right atrium (RA). Conduction velocities in the RA and in the KT were evaluated quantitatively on activation maps and qualitatively on isochronal and propagation maps. The presence, location, and timing of different types of multicomponent potentials were evaluated. A mean of 149±44 points were sampled in the RA, whereas a mean of 79±21 points were collected inside the KT. Propagation block at the level of crista terminalis was not found in any patient, whereas slow conduction inside the KT was found in all (median conduction velocity, 122 cm/s [110 to 135 cm/s] outside KT versus 60 cm/s [48 to 75 cm/s] inside KT; P<0.0001). Jackman potentials were identified inside KT in almost all the patients and were invariably found on the line of collision between the wavefronts activating the KT in opposite directions. CONCLUSIONS: No conduction block was detected inside the KT in patients with and without AVNRT. Conduction slowing was demonstrated during propagation of the sinus impulse inside the KT. The genesis of the Jackman potential may be related to the collision of the wavefronts activating KT in opposite directions.


Assuntos
Potenciais de Ação , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Adulto , Idoso , Análise de Variância , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Feminino , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Cidade de Roma , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/patologia , Terminologia como Assunto , Fatores de Tempo
13.
Indian Pacing Electrophysiol J ; 10(12): 556-61, 2011 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-21346824

RESUMO

Radiofrequency ablation procedures inside the left atrial appendage (LAA) are likely to involve dangerous complications because of a high thrombogenic effect. Cryoablation procedures are supposed to be safer. We describe two cases of successful cryoablation procedures. Two NavX-guided cryoablations of permanent focal atrial arrhythmias arising from the LAA were performed. Left atrial reconstruction and mapping allowed the zone of the earliest atrial potential to be recorded; the entire course of the ablation catheter was monitored. The arrhythmias were successfully ablated; no thrombotic complications were observed.

14.
J Cardiovasc Med (Hagerstown) ; 12(4): 294-6, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20856134

RESUMO

We report a patient with clinical manifestation of arrhythmias and evidence of noncompacted myocardium in both left and right ventricular apex. The diagnosis was made with intracardiac echo performed during the electrophysiologic study. This method has allowed the diagnosis of noncompaction of the ventricular myocardium due to its high resolution. Color Doppler showed trabecular recesses in communication with the ventricular cavity that could not be identified with transthoracic echocardiography.


Assuntos
Ecocardiografia Doppler em Cores , Miocárdio Ventricular não Compactado Isolado/diagnóstico por imagem , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Técnicas Eletrofisiológicas Cardíacas , Humanos , Miocárdio Ventricular não Compactado Isolado/complicações , Miocárdio Ventricular não Compactado Isolado/terapia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia
15.
J Interv Card Electrophysiol ; 29(3): 157-66, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20960225

RESUMO

PURPOSE: The purpose of the study is to evaluate the feasibility and utility of magnetic resonance (MR) image and electroanatomic (EA) maps integration in guiding detailed left ventricle (LV) anatomical and substrate mapping, identifying the most accurate registration strategy. METHODS: Twenty-five patients with dilated ischemic or non-ischemic cardiomyopathy were enrolled. We first verified the feasibility and accuracy of EA mapping and MR image integration using four different strategies (15 patients). Different EA maps were performed according to the strategy in exam: aortic map, collected from the descending portion of the arch to the ascending one; partial or complete LV map, reconstructed with a minimum of 40 widely distributed points or 200 points, respectively. We then evaluated the utility in LV substrate mapping of the most accurate integration method identified (ten patients). RESULTS: Strategy III, based on aortic map and a partial LV map, allowed us to obtain an accurate integration with MR images of aorta and LV with a lower number of EA LV points; we therefore used this strategy during phase II of the study. Both mean LV end diastolic volume and long- and short-axis LV end diastolic diameters obtained by MR were not significantly different compared with Carto measurements. Eighty-eight percent of the segments with transmural/subendocardial scar detected by delayed enhanced MR were localized on bipolar voltage maps projected on MR-integrated images. CONCLUSION: This study shows that integration strategy III represents the optimal registration method. Its clinical utility consists on guiding the catheter roving inside the chamber, mapping all areas of the LV and optimizing scar reconstruction.


Assuntos
Cardiomiopatias/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas/métodos , Imageamento por Ressonância Magnética/métodos , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Análise de Variância , Cardiomiopatias/cirurgia , Ablação por Cateter , Meios de Contraste , Estudos de Viabilidade , Feminino , Fluoroscopia , Gadolínio DTPA , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Modelos Lineares , Masculino , Disfunção Ventricular Esquerda/cirurgia
16.
J Interv Card Electrophysiol ; 27(2): 109-15, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19943098

RESUMO

PURPOSE: We investigated the relationship among esophageal warming, pain perception, and the site of radiofrequency (RF) delivery in the left atrium (LA) during the course of catheter ablation of atrial fibrillation. Such a procedure in awake patients is often linked to the development of visceral pain and esophageal warming. As a consequence, potentially dangerous complications have been described. METHODS: Twenty patients undergoing RF ablation in the LA were studied. An esophageal probe (EP) capable of measuring endoesophageal temperature (ET) was positioned before starting the procedure. The relative position of the EP and the tip of the ablator were evaluated through fluoroscopy imaging before starting each RF delivery, during which the highest value of the temperature was collected. After RF withdrawal, the patients were asked to define the intensity of the experienced pain by using a score index ranging from 0 (no pain) to 4 (pain requiring immediate RF interruption). RESULTS: The mean ET value during ablation was 39.59 +/- 4.71 degrees C. The EP proximity to the ablator's tip showed a high correlation with the development of the highest ET values (Spearman's rank correlation coefficient r = 0.49, confidence interval (CI) 0.55-0.41). Moreover, the highest values of pain intensity were reported when the RF was delivered to the atrial zones close to the EP projection (r = 0.50, CI 0.55-0.42) and when the highest ET levels were reached (r = 0.38, CI 0.30-0.45). CONCLUSIONS: Pain perception in LA ablation is significantly related to esophageal warming and is higher when the RF is delivered near the esophagus. It seems advisable to perform ET monitoring in sedated patients to avoid short- and long-term jeopardizing of the esophageal wall.


Assuntos
Fibrilação Atrial/cirurgia , Queimaduras por Corrente Elétrica/diagnóstico , Queimaduras por Corrente Elétrica/etiologia , Ablação por Cateter/efeitos adversos , Esôfago/lesões , Átrios do Coração/cirurgia , Dor/diagnóstico , Dor/etiologia , Fibrilação Atrial/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Termografia/métodos , Resultado do Tratamento
17.
J Cardiovasc Med (Hagerstown) ; 11(1): 59-60, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19786888

RESUMO

A 48-year-old man with an episode of syncope and family history of sudden cardiac death was evaluated. The ECG showed negative T waves from V1 to V3 with evidence of epsilon-wave. Magnetic resonance imaging showed replacement with fibrofatty tissue in midapical regions of free wall of the right ventricle with dyskinesia. Transthoracic echocardiography revealed only mild enlargement of the middle right ventricular cavity. A programmed ventricular stimulation induced only an unsustained monomorphic ventricular tachycardia. Intracardiac echocardiography showed mild right ventricular enlargement and outflow dilatation (26 mm), microaneurysms with systolic bulging along the apical segment of the right ventricle. Bipolar voltage mapping, performed by the Carto system, detected a circumscribed low potential (<1.5 mV) area at the same level of the right ventricular apex. Cardiovascular imaging improves the detection of abnormal myocardial areas. Further studies are warranted to support this hypothesis.


Assuntos
Displasia Arritmogênica Ventricular Direita/diagnóstico , Ecocardiografia , Imagens com Corantes Sensíveis à Voltagem , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/diagnóstico por imagem , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Displasia Arritmogênica Ventricular Direita/terapia , Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Eletrocardiografia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Síncope/etiologia
18.
Europace ; 11(4): 476-82, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19136492

RESUMO

AIMS: To evaluate clinical and arrhythmic outcomes in post-infarction cardiomyopathy patients implanted with a defibrillator (ICD) for primary prevention of sudden death. METHODS AND RESULTS: The SEARCH-MI registry is a European multi-centre, prospective, observational study enrolling patients after myocardial infarction, chronic left ventricular dysfunction and an ICD implanted for primary prevention of sudden death. Data on 556 patients with at least one recorded follow-up are presented. Survey to Evaluate Arrhythmia Rate in High-risk MI (SEARCH-MI) patients were sicker than those enrolled in MADIT-II with higher New York Heart Association class and left bundle branch block. Total mortality was 10.4%. Close to one-third (30%) of patients experienced episodes of sustained ventricular arrhythmia. One-quarter (23%) received at least one appropriate therapy and 10% inappropriate therapy. Gender (25% males vs. 5% females, P = 0.0009) and history of non-sustained ventricular tachycardia (24% with vs. 18% without P = 0.037) were predictive of appropriate ventricular therapy. CONCLUSION: SEARCH-MI represents the current clinical management of post-MI patients with left ventricular dysfunction indicated to defibrillator implant for primary prevention. European routine clinical practice was influenced by landmark trials and guidelines which impacted on the implantation of cardiac resynchronization therapy in over 25% of such patients. Non-sustained ventricular tachycardia identifies subjects with a higher incidence of appropriate ICD therapy.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Infarto do Miocárdio/complicações , Avaliação de Resultados em Cuidados de Saúde , Sistema de Registros , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Morte Súbita Cardíaca/etiologia , Europa (Continente) , Feminino , Fidelidade a Diretrizes , Inquéritos Epidemiológicos , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/fisiopatologia
19.
Pacing Clin Electrophysiol ; 29 Suppl 2: S29-34, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17169130

RESUMO

BACKGROUND: Large randomized trials show that in appropriately selected patients with left ventricular dysfunction, implantable cardioverter-defibrillators (ICDs) can improve overall survival at 2-5 years. Since direct implementation of the criteria used in the MADIT II and SCD-HeFT will lead to a marked rise in ICD implants, there is a growing fear that increased use of ICDs may cause a dramatic burden to health care systems. The ICD has traditionally been seen as an expensive form of treatment, which is difficult to accept at the first look. This is mainly due to the nonlinear character of the ICD investment, characterized by high initial expenditure, followed by a deferred pay-off in terms of clinical benefits. Cost-effectiveness analysis may help provide a different perspective on the problem of ICD cost, as may estimation of the daily cost of ICD treatment, assuming a time horizon of 5-7 years--a particularly interesting subject for further registry studies. METHODS AND RESULTS: Based on real expenditure data from 2002 to 2005, as recorded in the Search-MI Registry-Italian Sub-study of patients implanted on MADIT II indications, we estimated the daily costs associated with the device and leads. Over a 5-7 year time horizon, the average daily cost was estimated to be euro 4.60-euro 6.70. Translation of these figures into U.S. market conditions suggests a daily cost of around $7.90-$11.40. CONCLUSIONS: These findings appear useful to help evaluate the affordability of ICD in comparison with other therapeutic options in a context of limited available economic resources.


Assuntos
Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/economia , Cardioversão Elétrica/estatística & dados numéricos , Custos de Cuidados de Saúde/estatística & dados numéricos , Prevenção Primária/economia , Sistema de Registros/estatística & dados numéricos , Idoso , Análise Custo-Benefício , Feminino , Humanos , Itália/epidemiologia , Masculino , Prevenção Primária/estatística & dados numéricos
20.
Pacing Clin Electrophysiol ; 29 Suppl 2: S54-60, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17169134

RESUMO

BACKGROUND: Physiologic pacing has been demonstrated to be effective in preventing atrial fibrillation recurrences in patients with sinus bradycardia. Aim of the study was to evaluate long-term incidence of atrial fibrillation in a large population of patients affected by sinus node disease receiving physiologic pacing. Furthermore, predictors of arrhythmia recurrence and effect of pacing mode were investigated. POPULATION: Four hundred twenty-five patients (220 Male, 77 +/- 9 years) were retrospectively analyzed: implanted system was AAI in 20.5% and DDD in 79.5%. Thirty-four percent had atrial fibrillation before implant. RESULTS: Follow-up lasted on average 51 +/- 36 months (median 42, range 1 month-18 years). Sixty-six percent were on antiarrhythmic drug therapy. After 5 years, 89% survived, 74.5% had at least one episode of atrial fibrillation, 39.9% were submitted to electrical cardioversion, 67.2% were hospitalized because of cardiac causes, 33.3% developed permanent atrial fibrillation. Primary conduction system disease and valvular heart disease were independent predictors for atrial fibrillation recurrence. Preimplant atrial fibrillation predicted arrhythmia recurrence during the follow-up, but it did not predict development of permanent atrial fibrillation. AAI pacing, when compared with DDD, was associated to a lower rate of atrial fibrillation recurrences (AAI 28.7%, DDD 53.3%, P < 0.001). CONCLUSION: In spite of expected benefits of physiologic pacing, the development of atrial fibrillation and permanent atrial fibrillation were quite common. The additional benefits of multifunction pacemakers designed to prevent and treat atrial fibrillation should be evaluated in controlled studies.


Assuntos
Arritmia Sinusal/epidemiologia , Arritmia Sinusal/prevenção & controle , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/prevenção & controle , Estimulação Cardíaca Artificial/estatística & dados numéricos , Medição de Risco/métodos , Idoso , Arritmia Sinusal/diagnóstico , Fibrilação Atrial/diagnóstico , Comorbidade , Intervalo Livre de Doença , Feminino , Humanos , Itália/epidemiologia , Estudos Longitudinais , Masculino , Prevalência , Estudos Retrospectivos , Fatores de Risco , Prevenção Secundária