Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
BMJ Glob Health ; 8(12)2023 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-38114235

RESUMO

Diagnostics are widely considered crucial in the fight against antimicrobial resistance (AMR), which is expected to kill 10 million people annually by 2030. Nevertheless, there remains a substantial gap between the need for AMR diagnostics versus their development and implementation. To help address this problem, target product profiles (TPP) have been developed to focus developers' attention on the key aspects of AMR diagnostic tests. However, during discussion between a multisectoral working group of 51 international experts from industry, academia and healthcare, it was noted that specific AMR-related TPPs could be extended by incorporating the interdependencies between the key characteristics associated with the development of such TPPs. Subsequently, the working group identified 46 characteristics associated with six main categories (ie, Intended Use, Diagnostic Question, Test Description, Assay Protocol, Performance and Commercial). The interdependencies of these characteristics were then identified and mapped against each other to generate new insights for use by stakeholders. Specifically, it may not be possible for diagnostics developers to achieve all of the recommendations in every category of a TPP and this publication indicates how prioritising specific TPP characteristics during diagnostics development may influence (or not) a range of other TPP characteristics associated with the diagnostic. The use of such guidance, in conjunction with specific TPPs, could lead to more efficient AMR diagnostics development.


Assuntos
Testes Diagnósticos de Rotina , Resistência Microbiana a Medicamentos , Humanos , Testes Diagnósticos de Rotina/métodos
2.
Biomedicines ; 11(11)2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38002061

RESUMO

Three-dimensional (3D) tumor spheroids are regarded as promising models for utilization as preclinical assessments of chemo-sensitivity. However, the creation of these tumor spheroids presents challenges, given that not all tumor cell lines are able to form consistent and regular spheroids. In this context, we have developed a novel layer-by-layer coating of cellulose nanofibril-polyelectrolyte bilayers for the generation of spheroids. This technique builds bilayers of cellulose nanofibrils and polyelectrolytes and is used here to coat two distinct 96-well plate types: nontreated/non-sterilized and Nunclon Delta. In this work, we optimized the protocol aimed at generating and characterizing spheroids on difficult-to-grow pancreatic tumor cell lines. Here, diverse parameters were explored, encompassing the bilayer count (five and ten) and multiple cell-seeding concentrations (10, 100, 200, 500, and 1000 cells per well), using four pancreatic tumor cell lines-KPCT, PANC-1, MiaPaCa-2, and CFPAC-I. The evaluation includes the quantification (number of spheroids, size, and morphology) and proliferation of the produced spheroids, as well as an assessment of their viability. Notably, our findings reveal a significant influence from both the number of bilayers and the plate type used on the successful formation of spheroids. The novel and simple layer-by-layer-based coating method has the potential to offer the large-scale production of spheroids across a spectrum of tumor cell lines.

3.
Anal Chim Acta ; 1245: 340823, 2023 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-36737129

RESUMO

Cytokines play a very important role in our immune system by acting as mediators to put up a coordinated defense against foreign elements in our body. Elevated levels of cytokines in the body can signal to an ongoing response of the immune system to some abnormality. Thus, the quantification of a panel of cytokines can provide valuable information regarding the diagnosis of specific diseases and state of overall health of an individual. Conventional Enzyme Linked Immunosorbent Assay (ELISA) is the gold-standard for quantification of cytokines, however the need for trained personnel and expensive equipment limits its application to centralized laboratories only. In this context, there is a lack of simple, low-cost and portable devices which can allow for quantification of panels of cytokines at point-of-care and/or resource limited settings. Here, we report the development of a versatile, low-cost and portable bead-based centrifugal microfluidic platform allowing for multiplexed detection of cytokines with minimal hands-on time and an integrated colorimetric signal readout without the need for any external equipment. As a model, multiplexed colorimetric quantification of three target cytokines i.e., Tumor necrosis factor alpha (TNF-α), Interferon gamma (IFN-γ) and Interleukin-2 (IL-2) was achieved in less than 30 min with limits of detection in ng/mL range. The developed platform was further evaluated using spiked-in plasma samples to test for matrix interference. The ease of use, low-cost and portability of the developed platform highlight its potential to serve as a sample-to-answer solution for detection of cytokine panels in resource limited settings.


Assuntos
Colorimetria , Microfluídica , Citocinas , Ensaio de Imunoadsorção Enzimática , Biomarcadores
4.
Bioengineering (Basel) ; 9(11)2022 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-36354514

RESUMO

The liver exhibits complex geometrical morphologies of hepatic cells arranged in a hexagonal lobule with an extracellular matrix (ECM) organized in a specific pattern on a multi-scale level. Previous studies have utilized 3D bioprinting and microfluidic perfusion systems with various biomaterials to develop lobule-like constructs. However, they all lack anatomical relevance with weak control over the size and shape of the fabricated structures. Moreover, most biomaterials lack liver-specific ECM components partially or entirely, which might limit their biomimetic mechanical properties and biological functions. Here, we report 3D bioprinting of a sacrificial PVA framework to impart its trilobular hepatic structure to the decellularized liver extracellular matrix (dLM) hydrogel with polyethylene glycol-based crosslinker and tyrosinase to fabricate a robust multi-scale 3D liver construct. The 3D trilobular construct exhibits higher crosslinking, viscosity (182.7 ± 1.6 Pa·s), and storage modulus (2554 ± 82.1 Pa) than non-crosslinked dLM. The co-culture of HepG2 liver cells and NIH 3T3 fibroblast cells exhibited the influence of fibroblasts on liver-specific activity over time (7 days) to show higher viability (90-91.5%), albumin secretion, and increasing activity of four liver-specific genes as compared to the HepG2 monoculture. This technique offers high lumen patency for the perfusion of media to fabricate a densely populated scaled-up liver model, which can also be extended to other tissue types with different biomaterials and multiple cells to support the creation of a large functional complex tissue.

5.
Biosensors (Basel) ; 12(7)2022 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-35884324

RESUMO

Bioprinting is an acclaimed technique that allows the scaling of 3D architectures in an organized pattern but suffers from a scarcity of appropriate bioinks. Decellularized extracellular matrix (dECM) from xenogeneic species has garnered support as a biomaterial to promote tissue-specific regeneration and repair. The prospect of developing dECM-based 3D artificial tissue is impeded by its inherent low mechanical properties. In recent years, 3D bioprinting of dECM-based bioinks modified with additional scaffolds has advanced the development of load-bearing constructs. However, previous attempts using dECM were limited to low-temperature bioprinting, which is not favorable for a longer print duration with cells. Here, we report the development of a multi-material decellularized liver matrix (dLM) bioink reinforced with gelatin and polyethylene glycol to improve rheology, extrudability, and mechanical stability. This shear-thinning bioink facilitated extrusion-based bioprinting at 37 °C with HepG2 cells into a 3D grid structure with a further enhancement for long-term applications by enzymatic crosslinking with mushroom tyrosinase. The heavily crosslinked structure showed a 16-fold increase in viscosity (2.73 Pa s-1) and a 32-fold increase in storage modulus from the non-crosslinked dLM while retaining high cell viability (85-93%) and liver-specific functions. Our results show that the cytocompatible crosslinking of dLM bioink at physiological temperatures has promising applications for extended 3D-printing procedures.


Assuntos
Bioimpressão , Bioimpressão/métodos , Matriz Extracelular/química , Hidrogéis/química , Fígado , Temperatura , Engenharia Tecidual/métodos , Alicerces Teciduais/química
6.
Macromol Biosci ; 22(10): e2200137, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35899862

RESUMO

Three-dimensional multicellular spheroids (MCSs) are complex structure of cellular aggregates and cell-to-matrix interaction that emulates the in-vivo microenvironment. This research field has grown to develop and improve spheroid generation techniques. Here, we present a new platform for spheroid generation using Layer-by-Layer (LbL) technology. Layer-by-Layer (LbL) containing cellulose nanofibrils (CNF) assemble on a standard 96 well plate. Various bi-layer numbers, multiple cell seeding concentration, and two tumor cell lines (HEK 293 T, HCT 116) are utilized to generate and characterize spheroids. The number and proliferation of generated spheroids, the viability, and the response to the anti-cancer drug are examined. The spheroids are formed and proliferated on the LbL-CNF coated wells with no significant difference in connection to the number of LbL-CNF bi-layers; however, the number of formed spheroids correlates positively with the cell seeding concentration (122 ± 17) and (42 ± 8) for HCT 116 and HEK 293T respectively at 700 cells ml-1 . The spheroids proliferate progressively up to (309, 663) µm of HCT 116 and HEK 293T respectively on 5 bi-layers coated wells with maintaining viability. The (HCT 116) spheroids react to the anti-cancer drug. We demonstrate a new (LbL-CNF) coating strategy for spheroids generation, with high performance and efficiency to test anti-cancer drugs.


Assuntos
Antineoplásicos , Celulose , Antineoplásicos/farmacologia , Linhagem Celular Tumoral , Celulose/farmacologia , Ensaios de Seleção de Medicamentos Antitumorais , Células HEK293 , Humanos , Esferoides Celulares
8.
Sci Rep ; 12(1): 3539, 2022 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-35241725

RESUMO

Microfluidics has emerged rapidly over the past 20 years and has been investigated for a variety of applications from life sciences to environmental monitoring. Although continuous-flow microfluidics is ubiquitous, segmented-flow or droplet microfluidics offers several attractive features. Droplets can be independently manipulated and analyzed with very high throughput. Typically, microfluidics is carried out within planar networks of microchannels, namely, microfluidic chips. We propose that fibers offer an interesting alternative format with key advantages for enhanced optical coupling. Herein, we demonstrate the generation of monodisperse droplets within a uniaxial optofluidic Lab-in-a-Fiber scheme. We combine droplet microfluidics with laser-induced fluorescence (LIF) detection achieved through the development of an optical side-coupling fiber, which we term a periscope fiber. This arrangement provides stable and compact alignment. Laser-induced fluorescence offers high sensitivity and low detection limits with a rapid response time making it an attractive detection method for in situ real-time measurements. We use the well-established fluorophore, fluorescein, to characterize the Lab-in-a-Fiber device and determine the generation of [Formula: see text] 0.9 nL droplets. We present characterization data of a range of fluorescein concentrations, establishing a limit of detection (LOD) of 10 nM fluorescein. Finally, we show that the device operates within a realistic and relevant fluorescence regime by detecting reverse-transcription loop-mediated isothermal amplification (RT-LAMP) products in the context of COVID-19 diagnostics. The device represents a step towards the development of a point-of-care droplet digital RT-LAMP platform.


Assuntos
Dispositivos Lab-On-A-Chip , Vírus/isolamento & purificação , Fluorescência , Lasers
9.
Anal Chem ; 94(2): 787-792, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-34931815

RESUMO

The detection of living organisms at very low concentrations is necessary for the early diagnosis of bacterial infections, but it is still challenging as there is a need for signal amplification. Cell culture, nucleic acid amplification, or nanostructure-based signal enhancement are the most common amplification methods, relying on long, tedious, complex, or expensive procedures. Here, we present a cyanotype-based photochemical amplification reaction enabling the detection of low bacterial concentrations up to a single-cell level. Photocatalysis is induced with visible light and requires bacterial metabolism of iron-based compounds to produce Prussian Blue. Bacterial activity is thus detected through the formation of an observable blue precipitate within 3 h of the reaction, which corresponds to the concentration of living organisms. The short time-to-result and simplicity of the reaction are expected to strongly impact the clinical diagnosis of infectious diseases.


Assuntos
Bactérias , Doenças Transmissíveis , Humanos , Técnicas de Amplificação de Ácido Nucleico/métodos
10.
Electrophoresis ; 42(23): 2538-2551, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34510466

RESUMO

Improved sample preparation has the potential to address unmet needs for fast turnaround sepsis tests. In this work, we report elasto-inertial based rapid bacteria separation from diluted blood at high separation efficiency. In viscoelastic flows, we demonstrate novel findings where blood cells prepositioned at the outer wall entering a spiral device remain fully focused throughout the channel length while smaller bacteria migrate to the opposite wall. Initially, using microparticles, we show that particles above a certain size cut-off remain fully focused at the outer wall while smaller particles differentially migrate toward the inner wall. We demonstrate particle separation at 1 µm resolution at a total throughput of 1 mL/min. For blood-based experiments, a minimum of 1:2 dilution was necessary to fully focus blood cells at the outer wall. Finally, Escherichia coli spiked in diluted blood were continuously separated at a total flow rate of 1 mL/min, with efficiencies between 82 and 90% depending on the blood dilution. Using a single spiral, it takes 40 min to process 1 mL of blood at a separation efficiency of 82%. The label-free, passive, and rapid bacteria isolation method has a great potential for speeding up downstream phenotypic and genotypic analysis.


Assuntos
Bactérias , Técnicas Analíticas Microfluídicas , Sepse , Bactérias/isolamento & purificação , Células Sanguíneas/microbiologia , Humanos , Microfluídica , Sepse/sangue , Sepse/microbiologia
11.
ACS Sens ; 6(9): 3357-3366, 2021 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-34410700

RESUMO

Sepsis is a serious bloodstream infection where the immunity of the host body is compromised, leading to organ failure and death of the patient. In early sepsis, the concentration of bacteria is very low and the time of diagnosis is very critical since mortality increases exponentially with every hour after infection. Common culture-based methods fail in fast bacteria determination, while recent rapid diagnostic methods are expensive and prone to false positives. In this work, we present a sepsis kit for fast detection of bacteria in whole blood, here achieved by combining selective cell lysis and a sensitive colorimetric approach detecting as low as 103 CFU/mL bacteria in less than 5 h. Homemade selective cell lysis buffer (combination of saponin and sodium cholate) allows fast processing of whole blood in 5 min while maintaining bacteria alive (100% viability). After filtration, retained bacteria on filter paper are incubated under constant illumination with the electrochromic precursors, i.e., ferricyanide and ferric ammonium citrate. Viable bacteria metabolically reduce iron(III) complexes, initiating a photocatalytic cascade toward Prussian blue formation. As a proof of concept, we combine this method with antibiotic susceptibility testing to determine the minimum inhibitory concentration (MIC) using two antibiotics (ampicillin and gentamicin). Although this kit is used to demonstrate its applicability to sepsis, this approach is expected to impact other key sectors such as hygiene evaluation, microbial contaminated food/beverage, or UTI, among others.


Assuntos
Compostos Férricos , Sepse , Bactérias , Humanos , Sepse/diagnóstico
13.
Lab Chip ; 21(15): 2932-2944, 2021 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-34114589

RESUMO

With its origin estimated around December 2019 in Wuhan, China, the ongoing SARS-CoV-2 pandemic is a major global health challenge. The demand for scalable, rapid and sensitive viral diagnostics is thus particularly pressing at present to help contain the rapid spread of infection and prevent overwhelming the capacity of health systems. While high-income countries have managed to rapidly expand diagnostic capacities, such is not the case in resource-limited settings of low- to medium-income countries. Aiming at developing cost-effective viral load detection systems for point-of-care COVID-19 diagnostics in resource-limited and resource-rich settings alike, we report the development of an integrated modular centrifugal microfluidic platform to perform loop-mediated isothermal amplification (LAMP) of viral RNA directly from heat-inactivated nasopharyngeal swab samples. The discs were pre-packed with dried n-benzyl-n-methylethanolamine modified agarose beads used to selectively remove primer dimers, inactivate the reaction post-amplification and allowing enhanced fluorescence detection via a smartphone camera. Sample-to-answer analysis within 1 hour from sample collection and a detection limit of approximately 100 RNA copies in 10 µL reaction volume were achieved. The platform was validated with a panel of 162 nasopharyngeal swab samples collected from patients with COVID-19 symptoms, providing a sensitivity of 96.6% (82.2-99.9%, 95% CI) for samples with Ct values below 26 and a specificity of 100% (90-100%, 95% CI), thus being fit-for-purpose to diagnose patients with a high risk of viral transmission. These results show significant promise towards bringing routine point-of-care COVID-19 diagnostics to resource-limited settings.


Assuntos
COVID-19 , Teste para COVID-19 , Humanos , Microfluídica , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , RNA Viral/genética , SARS-CoV-2 , Sensibilidade e Especificidade , Smartphone
14.
Sci Rep ; 11(1): 8467, 2021 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-33875755

RESUMO

Passive particle manipulation using inertial and elasto-inertial microfluidics have received substantial interest in recent years and have found various applications in high throughput particle sorting and separation. For separation applications, elasto-inertial microfluidics has thus far been applied at substantial lower flow rates as compared to inertial microfluidics. In this work, we explore viscoelastic particle focusing and separation in spiral channels at two orders of magnitude higher Reynolds numbers than previously reported. We show that the balance between dominant inertial lift force, dean drag force and elastic force enables stable 3D particle focusing at dynamically high Reynolds numbers. Using a two-turn spiral, we show that particles, initially pinched towards the inner wall using an elasticity enhancer, PEO (polyethylene oxide), as sheath migrate towards the outer wall strictly based on size and can be effectively separated with high precision. As a proof of principle for high resolution particle separation, 15 µm particles were effectively separated from 10 µm particles. A separation efficiency of 98% for the 10 µm and 97% for the 15 µm particles was achieved. Furthermore, we demonstrate sheath-less, high throughput, separation using a novel integrated two-spiral device and achieved a separation efficiency of 89% for the 10 µm and 99% for the 15 µm particles at a sample flow rate of 1 mL/min-a throughput previously only reported for inertial microfluidics. We anticipate the ability to precisely control particles in 3D at extremely high flow rates will open up several applications, including the development of ultra-high throughput microflow cytometers and high-resolution separation of rare cells for point of care diagnostics.

15.
ACS Sens ; 6(3): 842-851, 2021 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-33724791

RESUMO

The biopharmaceutical market has been rapidly growing in recent years, creating a highly competitive arena where R&D is critical to strike a balance between clinical safety and profitability. Toward process optimization, the recent development and adoption of new process analytical technologies (PAT) highlight the dynamic complexity of mammalian/human cell culture processes, as well as the importance of fine-tuning and modeling key metabolites and proteins. In this context, simple, rapid, and cost-effective devices allowing routine at-line monitoring of specific proteins during process development and production are currently lacking. Here, we report the development of a versatile microfluidic protein analysis cartridge allowing the multiplexed bead-based immunodetection of specific proteins directly from complex mixtures with minimal hands-on time. Colorimetric quantification of Chinese hamster ovary (CHO) host cell proteins as key impurities, monoclonal antibodies as target biopharmaceuticals, and lactate dehydrogenase as a marker of cell viability was achieved with limits of detection in the 1-10 ng/mL range and analysis times as short as 30 min. The device was further demonstrated for the monitoring of a Rituximab-producing CHO cell bioreactor over the course of 8 days, providing comparable recoveries to standard enzyme-linked immunosorbent assay (ELISA) kits. The high sensitivity combined with robustness to matrix interference highlights the potential of the device to perform at-line measurements spanning from the bioreactor to the downstream processing.


Assuntos
Produtos Biológicos , Microfluídica , Animais , Células CHO , Técnicas de Cultura de Células , Cricetinae , Cricetulus , Humanos
16.
IEEE Sens J ; 21(12): 13060-13067, 2021 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35582203

RESUMO

Since the COVID-19 outbreak was declared a pandemic by the World Health Organization (WHO) in March 2020, ongoing efforts have been made to develop sensitive diagnostic platforms. Detection of viral RNA provides the highest sensitivity and specificity for detection of early and asymptomatic infections. Thus, this work aimed at developing a label-free genosensor composed of graphene as a working electrode that could be embedded into a flex printed circuit board (FPCB) for the rapid, sensitive, amplification-free and label-free detection of SARS-CoV-2. To facilitate liquid handling and ease of use, the developed biosensor was embedded with a user-friendly reservoir chamber. As a proof-of-concept, detection of a synthetic DNA strand matching the sequence of ORF1ab was performed as a two-step strategy involving the immobilization of a biotinylated complementary sequence on a streptavidin-modified surface, followed by hybridization with the target sequence recorded by the differential pulse voltammetric (DPV) technique in the presence of a ferro/ferricyanide redox couple. The effective design of the sensing platform improved its selectivity and sensitivity and allowed DNA quantification ranging from 100 fg/mL to [Formula: see text]/mL. Combining the electrochemical technique with FPCB enabled rapid detection of the target sequence using a small volume of the sample (5-[Formula: see text]). We achieved a limit-of-detection of 100 fg/mL, whereas the predicted value was ~33 fg/mL, equivalent to approximately [Formula: see text] copies/mL and comparable to sensitivities provided by isothermal nucleic acid amplification tests. We believe that the developed approach proves the ability of an FPCB-implemented DNA sensor to act as a potentially simpler and more affordable diagnostic assay for viral infections in Point-Of-Care (POC) applications.

17.
Immunology ; 162(1): 92-104, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32955733

RESUMO

Basophils are known for their role in allergic inflammation, which makes them suitable targets in allergy diagnostics such as the basophil activation test (BAT) and the microfluidic immunoaffinity basophil activation test (miBAT). Beside their role in allergy, basophils have an immune modulatory role in both innate immunity and adaptive immunity. To accomplish this mission, basophils depend on the capability to migrate from blood to extravascular tissues, which includes interactions with endothelial cells, extracellular matrix and soluble mediators. Their receptor repertoire is well known, but less is known how these receptor-ligand interactions impact the degranulation process and the responsiveness to subsequent activation. As the consequences of these interactions are crucial to fully appreciate the role of basophils in immune modulation and to enable optimization of the miBAT, we explored how basophil activation status is regulated by cytokines and cross-linking of adhesion molecules. The expression of adhesion molecules and activation markers on basophils from healthy blood donors was analysed by flow cytometry. Cross-linking of CD203c, CD62L, CD11b and CD49d induced a significant upregulation of CD63 and CD203c. To mimic in vivo conditions, valid also for miBAT, CD62L and CD49d were cross-linked followed by IgE-dependent activation (anti-IgE), which caused a reduced CD63 expression compared with anti-IgE activation only. IL-3 and IL-33 priming caused increased CD63 expression after IgE-independent activation (fMLP). Together, our data suggest that mechanisms operational both in the microfluidic chip and in vivo during basophil adhesion may impact basophil anaphylactic and piecemeal degranulation procedures and hence their immune regulatory function.


Assuntos
Basófilos/imunologia , Citocinas/imunologia , Imunoglobulina E/imunologia , Imunidade Adaptativa/imunologia , Adolescente , Adulto , Idoso , Antígenos CD/imunologia , Adesão Celular/imunologia , Células Endoteliais/imunologia , Matriz Extracelular/imunologia , Citometria de Fluxo/métodos , Humanos , Hipersensibilidade/imunologia , Imunidade Inata/imunologia , Pessoa de Meia-Idade , Tetraspanina 30/imunologia , Regulação para Cima/imunologia , Adulto Jovem
18.
Nanoscale ; 12(42): 21788-21797, 2020 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-33103175

RESUMO

According to reports by the World Health Organization (WHO), cancer-related deaths reached almost 10 million in 2018. Nearly 65% of these deaths occurred in low- to middle-income countries, a trend that is bound to increase since cancer diagnostics are not currently considered a priority in resource-limited settings (RLS). Thus, cost-effective and specific cancer screening and diagnostics tools are in high demand, particularly in RLS. The selective isolation and up-concentration of rare cells while maintaining cell viability and preventing phenotypic changes is a powerful tool to allow accurate and sensitive downstream analysis. Here, multi-layer cellulose nanofibril-based coatings functionalized with anti-EpCAM antibodies on the surface of disposable microfluidic devices were optimized for specific capture of target cells, followed by efficient release without significant adverse effects. HCT 116 colon cancer cells were captured in a single step with >97% efficiency at 41.25 µL min-1 and, when spiked in whole blood, an average enrichment factor of ∼200-fold relative to white blood cells was achieved. The release of cells was performed by enzymatic digestion of the cellulose nanofibrils which had a negligible impact on cell viability. In particular, >80% of the cells were recovered with at least 97% viability in less than 30 min. Such performance paves the way to expand and improve clinical diagnostic applications by simplifying the isolation of circulating tumor cells (CTCs) and other rare cells directly from whole blood.


Assuntos
Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas , Células Neoplásicas Circulantes , Contagem de Células , Linhagem Celular Tumoral , Separação Celular , Celulose , Humanos
19.
Biosens Bioelectron ; 166: 112442, 2020 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-32755809

RESUMO

Despite significant progress in diagnostics and disease management during the past decades, human immunodeficiency virus (HIV) infections are still responsible for nearly 1 million deaths every year, mostly in resource-limited settings. Thus, novel, accurate and cost-effective tools for viral load monitoring become crucial to allow specific diagnostics and the effective monitoring of the associated antiviral therapies. Herein, we report an effective combination of a (1) padlock probe (PLP)-mediated rolling circle amplification (RCA) bioassay and an (2) agarose bead-based microfluidic device for the affinity chromatography-based capture and detection of RCA products (RCPs) pre-labelled simultaneously with biotin and an organic fluorophore. This method allowed the efficient capture of ~1 µm-sized RCPs followed by their quantification either as discrete signals or an average fluorescence signal, thus being compatible with both high-resolution imaging for maximum sensitivity as well as simpler optical detection setups. A limit of detection < 30 fM was obtained for HIV-1 synthetic target with just a single round of RCA, comparable to recently reported procedures requiring technically complex amplification strategies such as hyperbranching and/or enzymatic digestion/amplification. Furthermore, targeting a set of five conserved regions in the HIV-1 gag gene, the method could specifically detect HIV-1 in 293T cell culture supernatants, as well as a set of 11 HIV-1 NIH reference samples with four different subtypes. The reported method provides simplicity of operation, unique versatility of signal transduction (i.e. average or discrete signals), and potential coupling with previously reported miniaturized photodetectors. These combined features hold promise for bringing RCA-based molecular diagnostics closer to the point-of-care.


Assuntos
Técnicas Biossensoriais , HIV-1 , Cromatografia de Afinidade , HIV-1/genética , Humanos , Microfluídica , Técnicas de Amplificação de Ácido Nucleico
20.
Lab Chip ; 20(3): 514-524, 2020 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-31898702

RESUMO

The simultaneous flow of gas and liquids in large scale conduits is an established approach to enhance the performance of different working systems under critical conditions. On the microscale, the use of gas-liquid flows is challenging due to the dominance of surface tension forces. Here, we present a technique to generate common gas-liquid flows on a centrifugal microfluidic platform. It consists of a spiral microchannel and specific micro features that allow for temporal and local control of stratified and slug flow regimes. We investigate several critical parameters that induce different gas-liquid flows and cause the transition between stratified and slug flows. We have analytically derived formulations that are compared with our experimental results to deliver a general guideline for designing specific gas-liquid flows. As an application of the gas-liquid flows in enhancing microfluidic systems' performance, we show the acceleration of the cell growth of E. coli bacteria in comparison to traditional culturing methods.


Assuntos
Escherichia coli/citologia , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas , Células Cultivadas , Técnicas Analíticas Microfluídicas/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...