Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Coll Radiol ; 10(10): 781-8, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24091048

RESUMO

Transition from film-screen to digital radiography requires changes in radiographic technique and workflow processes to ensure that the minimum radiation exposure is used while maintaining diagnostic image quality. Checklists have been demonstrated to be useful tools for decreasing errors and improving safety in several areas, including commercial aviation and surgical procedures. The Image Gently campaign, through a competitive grant from the FDA, developed a checklist for technologists to use during the performance of digital radiography in pediatric patients. The checklist outlines the critical steps in digital radiography workflow, with an emphasis on steps that affect radiation exposure and image quality. The checklist and its accompanying implementation manual and practice quality improvement project are open source and downloadable at www.imagegently.org. The authors describe the process of developing and testing the checklist and offer suggestions for using the checklist to minimize radiation exposure to children during radiography.


Assuntos
Lista de Checagem/normas , Segurança do Paciente/normas , Pediatria/normas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Intensificação de Imagem Radiográfica/normas , Criança , Humanos , Estados Unidos
2.
AJR Am J Roentgenol ; 199(6): 1337-41, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23169727

RESUMO

OBJECTIVE: The purpose of this article is to educate radiologists and technologists about the clinically relevant portion of the new digital radiography standards. CONCLUSION: Both the International Electrotechnical Commission (IEC standard 62494-1) and the American Association of Physicists in Medicine (AAPM Task Group 116) have developed similar standards for monitoring exposure in digital radiography to eliminate proprietary and confusing terminology. Radiologists and technologists will need to learn three new terms--exposure index, target exposure index, and deviation index--to understand the new standards.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde/normas , Doses de Radiação , Proteção Radiológica/normas , Intensificação de Imagem Radiográfica/normas , Radiometria/normas , Carga Corporal (Radioterapia) , Congressos como Assunto , Humanos , Sociedades Médicas , Tecnologia Radiológica , Terminologia como Assunto
3.
Med Phys ; 32(4): 1205-25, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15895604

RESUMO

Digital imaging provides an effective means to electronically acquire, archive, distribute, and view medical images. Medical imaging display stations are an integral part of these operations. Therefore, it is vitally important to assure that electronic display devices do not compromise image quality and ultimately patient care. The AAPM Task Group 18 (TG18) recently published guidelines and acceptance criteria for acceptance testing and quality control of medical display devices. This paper is an executive summary of the TG18 report. TG18 guidelines include visual, quantitative, and advanced testing methodologies for primary and secondary class display devices. The characteristics, tested in conjunction with specially designed test patterns (i.e., TG18 patterns), include reflection, geometric distortion, luminance, the spatial and angular dependencies of luminance, resolution, noise, glare, chromaticity, and display artifacts. Geometric distortions are evaluated by linear measurements of the TG18-QC test pattern, which should render distortion coefficients less than 2%/5% for primary/secondary displays, respectively. Reflection measurements include specular and diffuse reflection coefficients from which the maximum allowable ambient lighting is determined such that contrast degradation due to display reflection remains below a 20% limit and the level of ambient luminance (Lamb) does not unduly compromise luminance ratio (LR) and contrast at low luminance levels. Luminance evaluation relies on visual assessment of low contrast features in the TG18-CT and TG18-MP test patterns, or quantitative measurements at 18 distinct luminance levels of the TG18-LN test patterns. The major acceptable criteria for primary/ secondary displays are maximum luminance of greater than 170/100 cd/m2, LR of greater than 250/100, and contrast conformance to that of the grayscale standard display function (GSDF) of better than 10%/20%, respectively. The angular response is tested to ascertain the viewing cone within which contrast conformance to the GSDF is better than 30%/60% and LR is greater than 175/70 for primary/secondary displays, or alternatively, within which the on-axis contrast thresholds of the TG18-CT test pattern remain discernible. The evaluation of luminance spatial uniformity at two distinct luminance levels across the display faceplate using TG18-UNL test patterns should yield nonuniformity coefficients smaller than 30%. The resolution evaluation includes the visual scoring of the CX test target in the TG18-QC or TG18-CX test patterns, which should yield scores greater than 4/6 for primary/secondary displays. Noise evaluation includes visual evaluation of the contrast threshold in the TG18-AFC test pattern, which should yield a minimum of 3/2 targets visible for primary/secondary displays. The guidelines also include methodologies for more quantitative resolution and noise measurements based on MTF and NPS analyses. The display glare test, based on the visibility of the low-contrast targets of the TG18-GV test pattern or the measurement of the glare ratio (GR), is expected to yield scores greater than 3/1 and GRs greater than 400/150 for primary/secondary displays. Chromaticity, measured across a display faceplate or between two display devices, is expected to render a u',v' color separation of less than 0.01 for primary displays. The report offers further descriptions of prior standardization efforts, current display technologies, testing prerequisites, streamlined procedures and timelines, and TG18 test patterns.


Assuntos
Terminais de Computador/normas , Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/normas , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/métodos , Sistemas de Informação em Radiologia/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Gráficos por Computador/normas , Guias como Assunto , Humanos , Controle de Qualidade , Intensificação de Imagem Radiográfica/normas , Padrões de Referência , Software , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...