Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cardiol Young ; 33(10): 1840-1845, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36259096

RESUMO

BACKGROUND: Right ventricular outflow tract intervention spans transcatheter, surgical, or hybrid pulmonary valve replacement methodologies. Standardised pre-procedure workup includes cardiac MRI to identify an intended valve site (landing zone). Our institutional practice includes measurement of the right ventricular outflow tract perimeter (circumference) of this site in end-systole. Our primary aim was to compare patients by their perimeter values to the palliative interventions performed (transcatheter versus surgical/hybrid methodologies). METHODS: Retrospective review of patients undergoing pulmonary valve replacement from January 2017 to 2021. We performed perimeter measurements at the intended valve site on advanced imaging; the outcomes of interventions were outlined via descriptive and statistical analyses. RESULTS: A total of 37 patients underwent pulmonary valve replacement that met study criteria - 21 transcatheter, 7 surgical, and 9 hybrid. Median age at intervention was 26 years (range 8-70). The mean end-systolic perimeter of the transcatheter cohort was 88.9 ± 8.7 mm and in the surgical/hybrid cohort measured 106.6 ± 7.5 mm. For the transcatheter cohort, the median "circularised" diameter derived from the perimeter measurement (divided by π) was 27.7 mm (range 24.3-32.4). Notably, this correlated (r = 0.93, p < 0.01) with the median diameter of the narrowest region during actual transcatheter right ventricular outflow tract balloon sizing (lateral imaging) of 27.1 mm (range 23.2-30.1). CONCLUSIONS: Right ventricular outflow tract perimeter measurement to determine circularised diameter is useful in planning pulmonary valve replacement in terms of candidacy of transcatheter versus the need for a surgical/hybrid approach. The circularised diameter correlates with transcatheter right ventricular outflow tract balloon sizing.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Criança , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/cirurgia , Estudos Retrospectivos , Cateterismo Cardíaco/métodos
2.
World J Pediatr Congenit Heart Surg ; 12(2): 213-219, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33684011

RESUMO

BACKGROUND: Surgical pulmonary artery banding (PAB) has been limited in practice because of later requirement for surgical removal or adjustment. The aim of this study is to describe our experience creating a dilatable PAB via transcatheter balloon dilation (TCBD) in congenital heart disease (CHD) patients. METHODS: Retrospective chart review of adjustable PAB-outline anatomical variants palliated and patient outcomes. RESULTS: Sixteen patients underwent dilatable PAB-median age 52 days (range 4-215) and weight 3.12 kg (1.65-5.8). Seven (44%) of the patients were premature, 11 (69%) had ventricular septal defect(s) with pulmonary over-circulation, four (25%) atrioventricular septal defects, and four (25%) single ventricle physiology. Subsequent to the index procedure: five patients have undergone intracardiac complete repair, six patients remain well palliated with no additional intervention, and four single ventricles await their next palliation. One patient died from necrotizing enterocolitis (unrelated to PAB) and one patient required a pericardiocentesis postoperatively. Five patients underwent TCBD of the PAB without complication-Two had one TCBD, two had two TCBD, and another had three TCBD. The median change in saturation was 14% (complete range 6-22) and PAB diameter 1.7 mm (complete range 1.1-5.2). Median time from PAB to most recent outpatient follow-up was 868 days (interquartile range 190-1,079). CONCLUSIONS: Our institution has standardized a PAB technique that allows for transcatheter incremental increases in pulmonary blood flow over time. This methodology has proven safe and effective enough to supplant other institutional techniques of limiting pulmonary blood flow in most patients-allowing for interval growth or even serving as the definitive palliation.


Assuntos
Cardiopatias Congênitas/cirurgia , Cuidados Paliativos/métodos , Artéria Pulmonar/cirurgia , Circulação Pulmonar/fisiologia , Procedimentos Cirúrgicos Vasculares/métodos , Feminino , Cardiopatias Congênitas/fisiopatologia , Humanos , Lactente , Recém-Nascido , Masculino , Artéria Pulmonar/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...