1.
J Cardiovasc Electrophysiol ; 34(9): 1961-1968, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37449437

RESUMO

INTRODUCTION: Insertable cardiac monitors (ICMs) are commonly used to diagnose cardiac arrhythmias. False detections in the latest ICM systems remain an issue, primarily due to inaccurate R-wave sensing. New discrimination algorithms were developed and tested to reduce false detections of atrial fibrillation (AF), pause, and tachycardia episodes in ICMs. METHODS: Stored electrograms (EGMs) of AF, pause, and tachycardia episodes detected by Abbott Confirm Rx™ ICMs were extracted from the Merlin.net™ Patient Care Network, and manually adjudicated to establish independent training and testing datasets. New discrimination algorithms were developed to reject false episodes due to inaccurate R-wave sensing, P-wave identification, and R-R interval patterns. The performance of these new algorithms was quantified by false positive reduction (FPR) and true positive maintenance (TPM), relative to the existing algorithms. RESULTS: The new AF detection algorithm was trained on 5911 EGMs from 744 devices, resulting in 66.9% FPR and 97.8% TPM. In the testing data set of 1354 EGMs from 119 devices, this algorithm achieved 45.8% FPR and 97.0% TPM. The new pause algorithm was trained on 7178 EGMs from 1490 devices, resulting in 70.9% FPR and 98.7% TPM. In the testing data set of 1442 EGMs from 340 devices, this algorithm achieved 74.4% FPR and 99.3% TPM. The new tachycardia algorithm was trained on 520 EGMs from 204 devices, resulting in 57.0% FPR and 96.6% TPM. In the testing data set of 459 EGMs from 237 devices, this algorithm achieved 57.9% FPR and 96.5% TPM. CONCLUSION: The new algorithms substantially reduced false AF, pause, and tachycardia episodes while maintaining the majority of true arrhythmia episodes detected by the Abbott ICM algorithms that exist today. Implementing these algorithms in the next-generation ICM systems may lead to improved detection accuracy, in-clinic efficiency, and device battery longevity.


Assuntos
Fibrilação Atrial , Eletrocardiografia Ambulatorial , Humanos , Eletrocardiografia Ambulatorial/métodos , Fibrilação Atrial/diagnóstico , Algoritmos , Síncope/diagnóstico
2.
Heart Rhythm O2 ; 3(5): 560-567, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36340481

RESUMO

Background: The identification of low-voltage proarrhythmic areas for catheter ablation of scar-mediated ventricular tachycardia (VT) remains challenging. Integration of myocardial perfusion imaging (single-photon emission computed tomography/computed tomography; SPECT/CT) and electroanatomical mapping (EAM) may improve delineation of the arrhythmogenic substrate. Objective: To assess the feasibility of SPECT/CT image integration with voltage maps using the EnSite Precision system (Abbott) in patients undergoing scar-mediated VT ablation. Methods: Patients underwent SPECT/CT imaging prior to left ventricular (LV) EAM with the EnSite Precision mapping system. The SPECT/CT, EAM data, and ablation lesions were retrospectively co-registered in the EnSite Precision system and exported for analysis. Segmental tissue viability scores were calculated based on SPECT/CT perfusion and electrogram bipolar voltage amplitude. Concordance, specificity, and sensitivity between the 2 modalities as well as the impact of SPECT/CT spatial resolution were evaluated. Results: Twenty subjects (95% male, 67 ± 7 years old, left ventricular ejection fraction 36% ± 11%) underwent EAM and SPECT/CT integration. A concordance of 70% was found between EAM and SPECT/CT for identification of cardiac segments as scar vs viable, with EAM showing a 68.5% sensitivity and 76.4% specificity when using SPECT/CT as a gold standard. Projection on low-resolution 3D geometries led to an average decrease of 38% ± 22% of the voltage points used. Conclusion: The study demonstrated the feasibility of integrating SPECT/CT with EAM performed retrospectively for characterization of anatomical substrates during VT ablation procedures.

3.
BMC Cardiovasc Disord ; 22(1): 439, 2022 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-36209063

RESUMO

BACKGROUND: Insertable cardiac monitors (ICMs) are small subcutaneously implanted devices that detect changes in R-wave amplitudes (RWAs), effective in arrhythmia-monitoring. Although ICMs have proven to be immensely successful, electrical artefacts are frequent and can lead to misdiagnosis. Thus, there is a growing need to sustain and increase efficacy in detection rates by gaining insight into various patient-specific factors such as body postures and activities. METHODS: RWAs were measured in 15 separate postures, including supine, lying on the right-side (RS) or left-side (LS) and sitting, and two separate ICM orientations, immediately after implantation of Confirm Rx™ ICM in 99 patients. RESULTS: The patients (53 females and 46 males, mean ages 66.62 ± 14.7 and 66.40 ± 12.25 years, respectively) had attenuated RWAs in RS, LS and sitting by ~ 26.4%, ~ 27.8% and ~ 21.2% respectively, compared to supine. Gender-based analysis indicated RWAs in RS (0.32 mV (0.09-1.03 mV), p < 0.0001) and LS (0.37 mV (0.11-1.03 mV), p = 0.004) to be significantly attenuated compared to supine (0.52 mV (0.20-1.03 mV) for female participants. Similar attenuation was not evident for male participants. Further, parasternally oriented ICMs (n = 44), attenuated RWAs in RS (0.37 mV(0.09-1.03 mV), p = 0.05) and LS (0.34 mV (0.11-1.03 mV), p = 0.02) compared to supine (0.48 mV (0.09-1.03 mV). Similar differences were not observed in participants with ICMs in the 45°-relative-to-sternum (n = 46) orientation. When assessing the combined effect of gender and ICM orientation, female participants demonstrated plausible attenuation in RWAs for RS and LS postures compared to supine, an effect not observed in male participants. CONCLUSION: This is the first known study depicting the effects on RWA due to body postures and activities immediately post-implantation with an overt impact by gender and orientation of ICM. Future work assessing the cause of gender-based differences in RWAs may be critical. TRIAL REGISTRATION: Clinical Trials, NCT03803969. Registered 15 January 2019 - Retrospectively registered, https://clinicaltrials.gov/NCT03803969.


Assuntos
Arritmias Cardíacas , Eletrocardiografia Ambulatorial , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Exercício Físico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Postura
4.
Cardiovasc Digit Health J ; 3(2): 80-88, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35493270

RESUMO

Background: Insertable cardiac monitors (ICMs) are accepted tools in cardiac arrhythmia management. Consistent R-wave amplitude (RWA) is essential for optimal detection. Objectives: Assess RWAs with posture/activities at insertion and at 30 days. Methods: Participants (n = 90) with Confirm Rx™ ICM had RWAs measured in different postures (supine, right-side [RS], left-side [LS], sitting, and standing) and defined physical activities (including isometric push [IPUSH] and pull) at 2 time points. ICMs were inserted in 45° to sternum and parasternal orientations. Results: There were significant reductions at insertion with RS, LS, sitting, or standing vs supine (reference position) (all P < .05). At 30 days, significant changes only occurred with LS and sitting (P < .05). Sex had an effect on RWAs, with females having significant variability at insertion (supine vs RS, LS, sitting, standing, and IPUSH; all P < .05). Males showed large RWA interpatient variabilities but minimal differences between positions vs supine. At 30 days, RS, LS, and sitting positions remained significant for females (P < .05), while in males RWAs were higher than at insertion for most postures and activities. The orientation 45° to sternum had consistently higher RWAs vs parasternal orientation at both time points (P < .0001). In females, ICM orientation had no significant effect on RWAs; however, in males the 45° to sternum produced higher RWAs. ICM movement from the insertion site showed no correlation with RWA changes. Conclusion: The mean RWAs were higher at 30 days with less interparticipant and interpostural variability; males had higher RWAs compared to females; 45° to sternum orientation had higher RWAs; and ICM migration from the insertion site did not affect RWAs.

5.
J Cardiovasc Electrophysiol ; 33(4): 741-750, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35118767

RESUMO

BACKGROUND: Insertable cardiac monitors (ICMs) are essential for ambulatory arrhythmia diagnosis. However, definitive diagnoses still require time-consuming, manual adjudication of electrograms (EGMs). OBJECTIVE: To evaluate the clinical impact of selecting only key EGMs for review. METHODS: Retrospective analyses of randomly selected Abbott Confirm Rx™ devices with ≥90 days of remote transmission history were performed, with each EGM adjudicated as true or false positive (TP, FP). For each device, up to 3 "key EGMs" per arrhythmia type per day were prioritized for review based on ventricular rate and episode duration. The reduction in EGMs and TP days (patient-days with at least one TP EGM), and any diagnostic delay (from the first TP), were calculated versus reviewing all EGMs. RESULTS: In 1000 ICMs over a median duration of 8.1 months, at least one atrial fibrillation (AF), tachycardia, bradycardia, or pause EGM was transmitted by 424, 343, 190, and 325 devices, respectively, with a total of 95 716 EGMs. Approximately 90% of episodes were contributed by 25% of patients. Key EGM selection reduced EGM review burden by 43%, 66%, 77%, and 50% (55% overall), while reducing TP days by 0.8%, 2.1%, 0.2%, and 0.0%, respectively. Despite reviewing fewer EGMs, 99% of devices with a TP EGM were ultimately diagnosed on the same day versus reviewing all EGMs. CONCLUSION: Key EGM selection reduced the EGM review substantially with no delay-to-diagnosis in 99% of patients exhibiting true arrhythmias. Implementing these rules in the Abbott patient care network may accelerate clinical workflow without compromising diagnostic timelines.


Assuntos
Fibrilação Atrial , Diagnóstico Tardio , Fibrilação Atrial/diagnóstico , Bradicardia/diagnóstico , Humanos , Estudos Retrospectivos , Taquicardia/diagnóstico
6.
J Interv Card Electrophysiol ; 63(3): 661-668, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34855036

RESUMO

PURPOSE: SharpSense™ technology is an upgradable software enhancement introduced to the Abbott Confirm Rx™ insertable cardiac monitor (ICM). This study aims to characterize the real-world performance of SharpSense algorithms by comparing device detected pause and bradycardia episodes before and after the SharpSense upgrade. METHODS: Confirm Rx devices with at least 90 days monitoring each before and after SharpSense upgrade were included in the study. Bradycardia and pause detections and subcutaneous electrocardiograms (SECGs) within 90 days before and after the upgrade were extracted from Merlin.net™ patient care network for evaluation and adjudicated by expert adjudicators. RESULTS: A total of 197 devices were included in the analysis. Devices were implanted for syncope (35.0%), atrial fibrillation (32.5%), cryptogenic stroke (16.8%), and other indications including palpitations (15.7%). The SharpSense upgrade significantly reduced the number of bradycardia detections by 86.8% and pause detections by 93.1%. In adjudicated SECGs, the upgrade significantly reduced false positive (FP) bradycardia episodes by 91.5% and FP pause episodes by 82.8%. The percentage of devices with at least one FP episode was reduced from 39 to 20% for bradycardia and from 52 to 35% for pause. The number of devices with FP rate greater than 1 episode per week was reduced from 23 to 8% for bradycardia and from 39 to 20% for pause. CONCLUSIONS: In this real-world performance evaluation, the algorithms incorporated in SharpSense software upgrade in Confirm Rx ICMs substantially reduced false positive bradycardia and pause detections and the number of transmitted SECGs for clinic review.


Assuntos
Fibrilação Atrial , Eletrocardiografia Ambulatorial , Algoritmos , Bradicardia/diagnóstico , Humanos , Síncope
7.
J Atr Fibrillation ; 13(5): 2387, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34950332

RESUMO

Subcutaneous loop recorders (SCRMs) are subcutaneous electronic devices which have revolutionized the field of arrhythmia detection. They have become increasingly appealing due to advances such as miniaturization of device, longer battery life, bluetooth capabilities and relatively simple implantation technique without the need for complex surgical suites. They can be implanted in the office, patient bedside without the need to go to the operating room. One of the most common indications for their implantation is detection of atrial fibrillation (AF) after a cryptogenic stroke. They have also been utilized for assessing the success of rhythm control strategies such post pulmonary venous isolation. More recently studies have assessed the utility of SCRMs for detecting silent AF in at risk populations such as patients with sleep apnea or those on hemodialysis. In this paper, we review the evolution of SCRMs, the clinical studies assessing their value for different indications, their role incurrent clinical practice and future avenues in the era of smart wearable devices like apple watch etc.

8.
Pacing Clin Electrophysiol ; 44(10): 1663-1670, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34319603

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) involves stimulation of both right ventricle (RV) and left ventricle (LV). LV pacing from the sites of delayed electrical activation improves CRT response. The RV-LV conduction is typically measured in intrinsic rhythm. The differences in RV-LV conduction patterns and timing between intrinsic rhythm and during paced RV activation, these differences are not fully understood. METHODS: Enrolled patients were implanted with a de novo CRT device and quadripolar LV lead, with lead implant locations at the implanting physician's discretion. QRS duration and conduction delay between the RV lead and each of the four LV electrodes (D1, M2, M3, and P4) were measured during intrinsic conduction and RV pacing. RESULTS: Conduction measurements were collected from 275 patients across 14 international centers (68 ± 13 years of age, 73% male, 45% ischemic, 158 ± 22 ms QRS duration). Mean RV-LV conduction time was shorter during intrinsic conduction versus RV pacing by 59.6 ms (106.5 ± 36.5 versus 166.1 ± 32.1 ms, p < 0.001). The intra-LV activation delay between the latest and earliest activating LV electrode was also shorter during intrinsic conduction versus RV pacing by 6.6 ms (20.6 ± 13.1 vs. 27.2 ± 21.2 ms, p < 0.001). Intrinsic conduction and RV pacing resulted in a different activation order in 72.7% of patients, and the same LV activation order in 27.3%. CONCLUSIONS: Differences in RV-LV conduction time, intra-LV conduction time, and activation pattern were observed between intrinsic conduction and RV pacing. These findings highlight the importance of evaluating intrinsic versus paced ventricular activation to guide LV pacing site selection in CRT patients.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/fisiopatologia , Idoso , Dispositivos de Terapia de Ressincronização Cardíaca , Feminino , Humanos , Masculino , Desenho de Prótese
9.
J Interv Card Electrophysiol ; 61(3): 453-460, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32740689

RESUMO

PURPOSE: Multipoint pacing (MPP) improves left ventricular (LV) electrical synchrony in cardiac resynchronization therapy (CRT). SyncAV automatically adjusts atrioventricular delay (AVD) according to intrinsic AV intervals and may further improve synchrony. Their combination has not been assessed. The objective was to evaluate the improvement in electrical synchrony achieved by SyncAV combined with MPP in an international, multicenter study. METHODS: Patients with LBBB undergoing CRT implant with a quadripolar lead (Abbott Quartet™) were prospectively enrolled. QRS duration (QRSd) was measured by blinded observers from 12-lead ECG during: intrinsic conduction, BiV pacing (conventional biventricular pacing, nominal static AVD), MPP (2 LV cathodes maximally spaced, nominal static AVD), BiV + SyncAV, and MPP + SyncAV. All SyncAV offsets were individualized for each patient to yield the narrowest QRSd during BiV pacing. QRSd changes were compared by ANOVA and post hoc Tukey-Kramer tests. RESULTS: One hundred and three patients were enrolled (65.7 ± 12.1 years, 67% male, 37% ischemic, EF 26.4 ± 6.5%, PR 190.3 ± 39.1 ms). Relative to intrinsic conduction (QRSd of 165 ± 16 ms), BiV reduced QRSd by 11.9% to 145 ± 18 ms (P < 0.001 vs intrinsic), and MPP reduced QRSd by 13.3% to 142 ± 19 ms (P < 0.001 vs intrinsic). However, enabling SyncAV with a patient-optimized offset nearly doubled this QRSd reduction. BiV + SyncAV reduced QRSd by 22.0% to 128 ± 13 ms (P < 0.001 vs BiV), while MPP + SyncAV reduced QRSd further by 25.6% to 122 ± 14 ms (P < 0.05 vs BiV + SyncAV). CONCLUSION: SyncAV can significantly improve acute electrical synchrony beyond conventional CRT, with further improvement achieved by superimposing MPP.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Dispositivos de Terapia de Ressincronização Cardíaca , Eletrocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Humanos , Masculino , Resultado do Tratamento
10.
J Electrocardiol ; 62: 184-189, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32961473

RESUMO

BACKGROUND: Atrial natriuretic peptide (ANP), which is released by the heart in response to acute cardiac stretch, possesses cardiac electrophysiological properties that include modulation of ion channel function and repolarization. However, data regarding whether ANP can directly modulate electrical instability or arrhythmias are largely lacking. OBJECTIVE: This study sought to determine whether ANP modifies onset or electrophysiological characteristics of ventricular fibrillation (VF) induced by severe hypokalemia in an isolated heart model. METHODS: Langendorff-perfused rabbit hearts in the absence and presence of 10 nM ANP (n = 9 in each group) were subjected to a low potassium (K+) perfusate (1.2 mM K+). Left ventricular (LV) epicardial monophasic action potential (MAP) and pressure were monitored continuously. Incidence and time to onset of VF and dominant frequency during VF determined by spectral analysis were evaluated. RESULTS: ANP did not alter ventricular repolarization (MAP duration) or LV pressure during perfusion with physiologic, K+-containing solution. Within the first 30 s after low K+ perfusion, ANP accelerated the onset of beat-to-beat repolarization alternans (100% vs. 33% in ANP-treated vs. non-treated hearts, p < 0.01). During low K+ perfusion, the incidence of VF did not differ between ANP-treated and non-treated hearts (8 of 9 [89%] in each group). However, VF occurred sooner (3.75 ± 0.33 vs. 5.78 ± 0.70 min, P < 0.05) and immediately after VF onset, peak dominant frequency was higher (24.1 ± 7.3 vs. 14.2 ± 2.3 Hz, P = 0.01) in ANP-treated than in non-treated hearts. CONCLUSIONS: ANP accelerates initiation of VF and increases maximum dominant frequency during VF in isolated hearts subjected to severe hypokalemia.


Assuntos
Hipopotassemia , Fibrilação Ventricular , Animais , Arritmias Cardíacas , Fator Natriurético Atrial , Eletrocardiografia , Hipopotassemia/complicações , Coelhos
11.
J Interv Card Electrophysiol ; 57(3): 481-487, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32144679

RESUMO

PURPOSE: Cardiac resynchronization therapy (CRT) with left ventricular (LV) MultiPoint™ pacing (MPP) has been shown to improve CRT response by pacing two LV sites (LV1, LV2). While an additional LV pacing site reduces battery longevity, this cost can be minimized by leveraging an existing device-based capture management algorithm (LVCap™ Confirm). The purpose of this study was to evaluate the MPP battery longevity improvement achieved by configuring LV pacing sites to properly leverage LVCap Confirm. METHODS: Patients previously enrolled in the MORE-CRT MPP trial with existing MPP-enabled CRT-D devices (Abbott Quadra Assura MP™ CD3371-40QC, Quartet™ LV lead) underwent device interrogation. Device electrical characteristics and estimated battery longevities were compared for various MPP settings. RESULTS: At 2.1 ± 1.1 years post-implant, the estimated remaining battery longevity in 65 patients was 70 ± 14 months with MPP Off (LV pacing from minimum capture threshold). Enabling MPP with maximal anatomical separation between LV1 and LV2 cathodes reduced longevity by 15 ± 14%. However, swapping the LV1 and LV2 cathodes, such that the LV1 threshold was the higher of the two, allowed the device to take full advantage of the LVCap™ Confirm capture management algorithm, resulting in significantly lower longevity reduction of 9 ± 11% (p < 0.001). Ultimately, a mean MPP battery longevity improvement of 7.7 ± 10.3% (p < 0.001) was achieved by simply swapping LV1/LV2 configurations. CONCLUSIONS: By properly leveraging device-based capture management features, the impact of MPP on battery longevity can be significantly reduced.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Fontes de Energia Elétrica , Algoritmos , Análise de Falha de Equipamento , Humanos , Fatores de Tempo
12.
Europace ; 21(8): 1193-1202, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31056645

RESUMO

AIMS: Clinical outcomes after radiofrequency catheter ablation (RFCA) remain suboptimal in the treatment of non-paroxysmal atrial fibrillation (AF). Electrophysiological mapping may improve understanding of the underlying mechanisms. To describe the arrhythmia substrate in patients with persistent (Pers) and long-standing persistent (LSPers) AF, undergoing RFCA, using an integrated mechanism mapping technique. METHODS AND RESULTS: Patients underwent high-density electroanatomical mapping before and after catheter ablation. Integrated maps characterized electrogram (EGM) cycle length (CL) in regions with repetitive-regular (RR) activations, stable wavefront propagation, fragmentation, and peak-to-peak bipolar voltage. Among 83 patients (72% male, 60 ± 11 years old), RR activations were identified in 376 regions (mean CL 180 ± 31 ms). PersAF patients (n = 43) showed more RR sites per patient (5.3 ± 2.4 vs. 3.7 ± 2.1, P = 0.002) with faster CL (166 ± 29 vs. 190 ± 29 ms; P < 0.001) and smaller surface area of fragmented EGMs (15 ± 14% vs. 27 ± 17%, P < 0.001) compared with LSPersAF. The post-ablation map in 50 patients remaining in AF, documented reduction of the RR activities per patient (1.5 ± 0.7 vs. 3.7 ± 1.4, P < 0.001) and area of fragmentation (22 ± 17% vs. 8 ± 9%, P < 0.001). Atrial fibrillation termination during ablation occurred at RR sites (0.48 ± 0.24 mV; 170.5 ± 20.2 ms CL) in 31/33 patients (94%). At the latest follow-up, arrhythmia freedom was higher among patients receiving ablation >75% of RR sites (Q4 82.6%, Q3 63.1%, Q2 35.1%, and Q1 0%; P < 0.001). CONCLUSION: The integrated mapping technique allowed characterization of multiple arrhythmic substrates in non-paroxysmal AF patients. This technique might serve as tool for a substrate-targeted ablation approach.


Assuntos
Fibrilação Atrial , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/instrumentação , Mapeamento Potencial de Superfície Corporal/métodos , Eletrofisiologia Cardíaca/métodos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Fenômenos Eletrofisiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Assistência Perioperatória/métodos , Reprodutibilidade dos Testes , Resultado do Tratamento
13.
J Interv Card Electrophysiol ; 54(2): 141-149, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30483980

RESUMO

PURPOSE: Cardiac resynchronization therapy (CRT) with multipoint left ventricular (LV) pacing (MultiPoint™ Pacing [MPP]) improves long-term LV reverse remodeling, though questions persist about how to program LV pacing vectors and delays. We evaluated if an empirical method of programming MPP vectors and delays between pacing pulses improved CRT response similar to pressure-volume loop (PVL) optimized MPP programming. METHODS: Patients undergoing CRT implant (Quadra Assura MP™ CRT-D and Quartet™ LV lead) received MPP with programmed settings optimized either by PVL measurements at implant (PVL-OPT group) or empirically determined by maximizing the spatial separation between the two cathodes and minimal delays between the three ventricular pacing pulses (MAX-SEP group). CRT response was prospectively defined as a reduction in end-systolic volume (ESV) of ≥ 15% relative to baseline at 6 months as determined by a blinded observer. RESULTS: Patient characteristics at baseline (NYHA II-III, ejection fraction [EF] 27 ± 6%, QRS 151 ± 17 ms) were not significantly different between the PVL-OPT (n = 27) and MAX-SEP (n = 26) groups. During the follow-up period, there were no differences in the number of patients requiring reprogramming due to phrenic nerve stimulation or a high threshold for PVL-OPT vs. MAX-SEP (5/27 [19%] vs. 7/26 [27%], p = 0.53). After 6 months, ESV reduction, EF increase, and CRT response rate (RR) were similar for PVL-OPT vs. MAX-SEP (ESV - 20 ± 11 vs. - 22 ± 11%, p = 0.59; EF + 10 ± 4 vs. + 9 ± 7%, p = 0.53; RR 20/27 [74%] vs. 21/26 [81%], p = 0.74), while fewer patients in the PVL-OPT group experienced NYHA class reduction ≥ 2 (4/27 [15%] vs.15/26 [58%], p = 0.002). CONCLUSIONS: Both evaluated methods of MPP programming resulted in similar CRT outcomes. Empirical MPP programming by maximum spatial separation of LV cathodes may be an effective, simple, and non-invasive alternative to pressure-volume optimization.


Assuntos
Estimulação Cardíaca Artificial/métodos , Ecocardiografia/métodos , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Remodelação Ventricular/fisiologia , Idoso , Terapia de Ressincronização Cardíaca/métodos , Estudos de Coortes , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Medição de Risco , Volume Sistólico/fisiologia , Fatores de Tempo , Resultado do Tratamento
14.
Heart Rhythm ; 15(12): 1766-1774, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29940305

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) with multipoint left ventricular (LV) pacing (MultiPoint Pacing [MPP]) improves acute hemodynamics and chronic outcomes in comparison to conventional biventricular pacing (BiV), though MPP programming questions persist. OBJECTIVES: In this multicenter feasibility study, we evaluated the feasibility of using noninvasive systolic blood pressure (SBP) to guide MPP programming and assessed the chronic 6-month echocardiographic CRT response. METHODS: Patients implanted with MPP-enabled CRT-defibrillator devices underwent noninvasive hemodynamic assessment (finger arterial pressure) during a pacing protocol that included atrial-only pacing and various BiV and MPP configurations. Each configuration was repeated 4 times, alternating with a reference pacing configuration, to calculate the SBP difference relative to reference (ΔSBP). CRT configurations with the greatest ΔSBP were programmed. An independent core laboratory analyzed baseline and 6-month echocardiograms, with CRT response defined as a 6-month reduction in LV end-systolic volume ≥ 15%. RESULTS: Forty-two patients (71% male; LV ejection fraction 30.3% ± 7.5%; QRS duration 161 ± 19 ms; 26% had ischemic cardiomyopathy) were enrolled in 4 European centers. Relative to atrial-only pacing, the best BiV and best MPP configurations produced significant SBP elevations of 3.1 ± 4.2 (P < .01) and 4.1 ± 4.1 mm Hg (P < .01), respectively (BiV vs MPP; P < .01). Greater SBP elevations were associated with the best MPP compared with the best BiV configurations in 29 of 37 patients completing the pacing protocol (78%). Of MPP-programmed patients completing the 6-month follow-up visit, 23 of 27 (85%) were classified as CRT responders (6-month reduction in LV end-systolic volume 37.0% ± 13.6%). CONCLUSION: Acute noninvasive hemodynamics after CRT device implantation predominantly favored MPP over BiV programming. MPP programming guided by noninvasive hemodynamics resulted in positive LV structural remodeling.


Assuntos
Estimulação Cardíaca Artificial/métodos , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Hemodinâmica/fisiologia , Monitorização Fisiológica/métodos , Ecocardiografia , Estudos de Viabilidade , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Tempo
15.
Circ Arrhythm Electrophysiol ; 11(3): e005904, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29535136

RESUMO

BACKGROUND: Clinical outcomes after ablation of persistent atrial fibrillation remain suboptimal. Identification of AF drivers using a novel integrated mapping technique may be crucial to ameliorate the clinical outcome. METHODS AND RESULTS: Persistent AF patients were prospectively enrolled to undergo high-density electrophysiological mapping to identify repetitive-regular activities (RRas) before modified circumferential pulmonary vein (PV) ablation. They have been randomly assigned (1:1 ratio) to ablation of RRa followed by modified circumferential PV ablation (mapping group; n=41) or modified circumferential PV ablation alone (control group; n=40). The primary end point was freedom from arrhythmic recurrences at 1 year. In total, 81 persistent AF patients (74% male; mean age, 61.7±10.6 years) underwent mapping/ablation procedure. The regions exhibiting RRa were 479 in 81 patients (5.9±2.4 RRa per patient): 232 regions in the mapping group (n=41) and 247 in the control group (n=40). Overall, 185 of 479 (39%) RRas were identified within the PVs, whereas 294 of 479 (61%) in non-PV regions. Mapping-guided ablation resulted in higher arrhythmia termination rate when compared with conventional strategy (25/41, 61% versus 12/40, 30%; P<0.007). Total radiofrequency duration (P=0.38), mapping (P=0.46), and fluoroscopy times (P=0.69) were not significantly different between the groups. No major procedure-related adverse events occurred. After 1 year, 73.2% of mapping group patients were free from recurrences versus 50% of control group (P=0.03). CONCLUSIONS: Targeted ablation of regions showing RRa provided an adjunctive benefit in terms of arrhythmia freedom at 1-year follow-up in the treatment of persistent AF. These findings might support a patient-tailored strategy in subjects with nonparoxysmal AF and should be confirmed by additional larger, randomized, multicenter studies. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier NCT02571218.


Assuntos
Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Frequência Cardíaca/fisiologia , Imageamento Tridimensional , Cirurgia Assistida por Computador/métodos , Potenciais de Ação , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Fluoroscopia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Resultado do Tratamento
16.
J Interv Card Electrophysiol ; 51(3): 205-214, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29388068

RESUMO

PURPOSE: Cardiac disease frequently has a degenerative effect on cardiac pump function and regional myocardial contraction. Therefore, an accurate assessment of regional wall motion is a measure of the extent and severity of the disease. We sought to further validate an intra-operative, sensor-based technology for measuring wall motion and strain by characterizing left ventricular (LV) mechanical and electrical activation patterns in patients with normal (NSF) and impaired systolic function (ISF). METHODS: NSF (n = 10; ejection fraction = 62.9 ± 6.1%) and ISF (n = 18; ejection fraction = 35.1 ± 13.6%) patients underwent simultaneous electrical and motion mapping of the LV endocardium using electroanatomical mapping and navigational systems (EnSite™ NavX™ and MediGuide™, Abbott). Motion trajectories, strain profiles, and activation times were calculated over the six standard LV walls. RESULTS: NSF patients had significantly greater motion and systolic strains across all LV walls than ISF patients. LV walls with low-voltage areas showed less motion and systolic strain than walls with normal voltage. LV electrical dyssynchrony was significantly smaller in NSF and ISF patients with narrow-QRS complexes than ISF patients with wide-QRS complexes, but mechanical dyssynchrony was larger in all ISF patients than NSF patients. The latest mechanical activation was most often the lateral/posterior walls in NSF and wide-QRS ISF patients but varied in narrow-QRS ISF patients. CONCLUSIONS: This intra-operative technique can be used to characterize LV wall motion and strain in patients with impaired systolic function. This technique may be utilized clinically to provide individually tailored LV lead positioning at the region of latest mechanical activation for patients undergoing cardiac resynchronization therapy. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01629160.


Assuntos
Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Mapeamento Epicárdico/métodos , Interpretação de Imagem Assistida por Computador , Volume Sistólico/fisiologia , Idoso , Fibrilação Atrial/diagnóstico , Terapia de Ressincronização Cardíaca/métodos , Ablação por Cateter/métodos , Eletrocardiografia Ambulatorial/métodos , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Contração Miocárdica/fisiologia , Seleção de Pacientes , Recuperação de Função Fisiológica , Valores de Referência , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
17.
Pacing Clin Electrophysiol ; 41(2): 106-113, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29222865

RESUMO

BACKGROUND: Multipoint left ventricular (LV) pacing (MultiPoint™ Pacing [MPP], Abbott, Sylmar, CA, USA) improves the response rate to cardiac resynchronization therapy (CRT). We evaluated the feasibility of noninvasive radial artery tonometry (RAT) to characterize arterial pressure morphology changes (pre-ejection period [PEP] and ejection duration [ED]) between conventional CRT and MPP pacing interventions. METHODS: Patients with a MPP-enabled CRT device (Quadra Assura MP™, Abbott) underwent noninvasive RAT assessment (SphygmoCor CVMS, AtCor Medical Inc., Itasca, IL, USA) at 3-6 months after implantation. A pacing protocol was performed in a randomized order including one optimized conventional biventricular CRT (CONV) configuration using the distal electrode and five MPP configurations. The PEP, ED, and PEP/ED ratio were determined for each intervention from the RAT pressure waveform and electrocardiogram. RESULTS: Pressure waveforms were successfully recorded in 19 patients (89% male, QRS 147 ± 16 ms, 63% ischemic). In 17/19 (89%) patients, at least one MPP intervention resulted in improved PEP, ED, and PEP/ED compared to CONV. The MPP intervention with greatest separation of LV cathodes and minimum intra-LV delay significantly improved PEP (mean PEP -15 ± 33% vs -8 ± 32% [CONV], P = 0.04) and ED (mean ED +8 ± 8% [MPP] vs +4 ± 7% [CONV], P = 0.02), and PEP/ED (-0.07 ± 0.14 [MPP] vs -0.04 ± 0.13 [CONV], P = 0.02) compared with CONV. CONCLUSIONS: Noninvasive RAT efficiently characterizes changes in PEP and ED between CONV and MPP interventions. MPP configurations using the widest separation among LV cathodes and minimum intra-LV delay may significantly improve RAT-derived parameters as compared to conventional CRT.


Assuntos
Hemodinâmica/fisiologia , Manometria/métodos , Marca-Passo Artificial , Artéria Radial/fisiologia , Idoso , Dispositivos de Terapia de Ressincronização Cardíaca , Ecocardiografia , Eletrocardiografia , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino
18.
Europace ; 19(4): 588-595, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28431058

RESUMO

AIMS: The aim of this study was to evaluate any benefits to the number of viable pacing vectors and maximal spatial coverage with quadripolar left ventricular (LV) leads when compared with tripolar and bipolar equivalents in patients receiving cardiac resynchronization therapy (CRT). METHODS AND RESULTS: A meta-analysis of five previously published clinical trials involving the Quartet™ LV lead (St Jude Medical, St Paul, MN, USA) was performed to evaluate the number of viable pacing vectors defined as capture thresholds ≤2.5 V and no phrenic nerve stimulation and maximal spatial coverage of viable vectors in CRT patients at pre-discharge (n = 370) and first follow-up (n = 355). Bipolar and tripolar lead configurations were modelled by systematic elimination of two and one electrode(s), respectively, from the Quartet lead. The Quartet lead with its four pacing electrodes exhibited the greatest number of pacing vectors per patient when compared with the best bipolar and the best tripolar modelled equivalents. Similarly, the Quartet lead provided the highest spatial coverage in terms of the distance between two furthest viable pacing cathodes when compared with the best bipolar and the best tripolar configurations (P < 0.05). Among the three modelled bipolar configurations, the lead configuration with the two most distal electrodes resulted in the highest number of viable pacing vectors. Among the four modelled tripolar configurations, elimination of the second proximal electrode (M3) resulted in the highest number of viable pacing options per patient. There were no significant differences observed between pre-discharge and first follow-up analyses. CONCLUSION: The Quartet lead with its four electrodes and the capability to pace from four anatomical locations provided the highest number of viable pacing vectors at pre-discharge and first follow-up visits, providing more flexibility in device programming and enabling continuation of CRT in more patients when compared with bipolar and tripolar equivalents.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Eletrodos Implantados/estatística & dados numéricos , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/prevenção & controle , Marca-Passo Artificial/estatística & dados numéricos , Terapia Assistida por Computador/instrumentação , Terapia Assistida por Computador/estatística & dados numéricos , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Ventrículos do Coração , Humanos , Masculino , Prevalência , Resultado do Tratamento
19.
Europace ; 19(2): 329-331, 2017 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28172643

RESUMO

We report a case in which a novel three-dimensional (3D) electromagnetic cardiovascular navigation system (MediGude™, St. Jude Medical, St. Paul, MN, USA) was used to create a 3D reconstruction of the axillary vein and its anatomic course to guide its successful puncture and cannulation. The MediGuide system's projection accuracy has proved to offer a level of precision that is sufficient to achieve axillary vein access. This highlights its enormous possibilities to obtain 3D venous system reconstruction with minimal fluoroscopic use when performing cardiac or even non-cardiac procedures.


Assuntos
Veia Axilar/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Imageamento Tridimensional/métodos , Implantação de Prótese/métodos , Veia Subclávia/diagnóstico por imagem , Humanos , Flebografia , Estudo de Prova de Conceito
20.
Europace ; 19(10): 1700-1709, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27738070

RESUMO

AIMS: In times of evolving cardiac resynchronization therapy, intra-procedural characterization of left ventricular (LV) mechanical activation patterns is desired but technically challenging with currently available technologies. In patients with normal systolic function, we evaluated the feasibility of characterizing LV wall motion using a novel sensor-based, real-time tracking technology. METHODS AND RESULTS: Ten patients underwent simultaneous motion and electrical mapping of the LV endocardium during sinus rhythm using electroanatomical mapping and navigational systems (EnSite™ NavX™ and MediGuide™, SJM). Epicardial motion data were also collected simultaneously at corresponding locations from accessible coronary sinus branches. Displacements at each mapping point and times of electrical and mechanical activation were combined over each of the six standard LV wall segments. Mechanical activation timing was compared with that from electrical activation and preoperative 2D speckle tracking echocardiography (echo). MediGuide-based displacement data were further analysed to estimate LV chamber volumes that were compared with echo and magnetic resonance imaging (MRI). The lateral and septal walls exhibited the largest (12.5 [11.6-15.0] mm) and smallest (10.2 [9.0-11.3] mm) displacement, respectively. Radial displacement was significantly larger endocardially than epicardially (endo: 6.7 [5.0-9.1] mm; epi: 3.8 [2.4-5.6] mm), while longitudinal displacement was significantly larger epicardially (endo: 8.0 [5.0-10.6] mm; epi: 10.3 [7.4-13.8] mm). Most often, the anteroseptal/anterior and lateral walls showed the earliest and latest mechanical activations, respectively. 9/10 patients had concordant or adjacent wall segments of latest mechanical and electrical activation, and 6/10 patients had concordant or adjacent wall segments of latest mechanical activation as measured by MediGuide and echo. MediGuide's LV chamber volumes were significantly correlated with MRI (R2= 0.73, P < 0.01) and echo (R2= 0.75, P < 0.001). CONCLUSION: The feasibility of mapping-guided intra-procedural characterization of LV wall motion was established. CLINICAL TRIAL REGISTRATION: http://www.clinicaltrials.gov; Unique identifier: CT01629160.


Assuntos
Potenciais de Ação , Fenômenos Eletromagnéticos , Monitorização Ambulatorial/instrumentação , Telemetria/instrumentação , Transdutores , Função Ventricular Esquerda , Idoso , Ecocardiografia , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial/métodos , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Volume Sistólico , Sístole , Telemetria/métodos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...