Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 127(4): 042501, 2021 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-34355962

RESUMO

A novel approach for isomer depletion in ion-atom collisions is proposed and considered theoretically. Analyses are performed for the depletion of the ^{93m}Mo isomer for which an unexpectedly large probability was measured in the beam-based experiment of Chiara et al. [Nature (London) 554, 216 (2018)NATUAS0028-083610.1038/nature25483]. The subsequent attempt at a theoretical description based on state-of-the-art atomic theory did not reproduce the experimental result [Wu et al., Phys. Rev. Lett. 122, 212501 (2019)PRLTAO0031-900710.1103/PhysRevLett.122.212501] and showed a dramatic disagreement with the experiment (by many orders of magnitude). This conflict calls for further research on the nature of isomer depletion mechanisms occurring in atomic processes. Here, we propose to consider the ^{93m}Mo isomer depletion as the nuclear excitation by electron capture in resonant transfer process taking into account the momentum distribution of the target electrons. Although our results only slightly shift the upper theoretical limit for the total ^{93m}Mo isomer depletion probability toward the experimental value, they show the importance of considering the Compton profile in the theoretical description, in particular for the L shell, for which the depletion probability increases by many orders of magnitude.

3.
Rev Sci Instrum ; 89(10): 10I126, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399810

RESUMO

A set of gamma ray spectrometers has been designed for ITER within the Radial Gamma Ray Spectrometer (RGRS) project. The aim of this project is designing a system, integrated with the ITER radial neutron camera, which is able to measure the gamma-rays emitted from the plasma with a good energy resolution (about 1.5% at 4.44 MeV) and at high counting rates (in excess of 1 MHz). The RGRS will be able to operate both in the D phase and in the full-power DT phase and will measure gamma rays from (i) reactions between fast ions, such as α particles, and light impurities and (ii) bremsstrahlung emission generated by runaway electron interactions with both plasma bulk and tokamak walls. The RGRS detectors are arranged in nine lines of sights (able to cover a radial region with r < a/3), each featuring a large LaBr3 scintillator crystal. Due to the high neutron flux and magnetic field, several solutions have been adopted to guarantee a good signal to background ratio and MHz counting rate capabilities. The RGRS is capable to combine space and energy distribution measurements of α particles and runaway electrons, which will help the study of the fast particle physics in a burning plasma.

4.
Appl Radiat Isot ; 142: 187-193, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30342378

RESUMO

In this study, we investigated the feasibility of copper ore analysis on a running belt conveyor by measuring the delayed positron annihilation quanta based on the beta-decay of 62Cu, which was previously activated by a D-T, 14 MeV neutron generator. We constructed a model of a belt conveyor that measured 10 m in length to test this method. Our measurements demonstrated the feasibility of the method but practical constraints imposed by user demands and the industrial environment would make the design impractical and cost inefficient.

5.
Nature ; 554(7691): 216-218, 2018 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-29420479

RESUMO

The atomic nucleus and its electrons are often thought of as independent systems that are held together in the atom by their mutual attraction. Their interaction, however, leads to other important effects, such as providing an additional decay mode for excited nuclear states, whereby the nucleus releases energy by ejecting an atomic electron instead of by emitting a γ-ray. This 'internal conversion' has been known for about a hundred years and can be used to study nuclei and their interaction with their electrons. In the inverse process-nuclear excitation by electron capture (NEEC)-a free electron is captured into an atomic vacancy and can excite the nucleus to a higher-energy state, provided that the kinetic energy of the free electron plus the magnitude of its binding energy once captured matches the nuclear energy difference between the two states. NEEC was predicted in 1976 and has not hitherto been observed. Here we report evidence of NEEC in molybdenum-93 and determine the probability and cross-section for the process in a beam-based experimental scenario. Our results provide a standard for the assessment of theoretical models relevant to NEEC, which predict cross-sections that span many orders of magnitude. The greatest practical effect of the NEEC process may be on the survival of nuclei in stellar environments, in which it could excite isomers (that is, long-lived nuclear states) to shorter-lived states. Such excitations may reduce the abundance of the isotope after its production. This is an example of 'isomer depletion', which has been investigated previously through other reactions, but is used here to obtain evidence for NEEC.

6.
Rev Sci Instrum ; 85(11): 11E425, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430332

RESUMO

The high resolution X-Ray crystal spectrometer at the JET tokamak has been upgraded with the main goal of measuring the tungsten impurity concentration. This is important for understanding impurity accumulation in the plasma after installation of the JET ITER-like wall (main chamber: Be, divertor: W). This contribution provides details of the upgraded spectrometer with a focus on the aspects important for spectral analysis and plasma parameter calculation. In particular, we describe the determination of the spectrometer sensitivity: important for impurity concentration determination.

7.
Phys Rev Lett ; 107(7): 073001, 2011 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-21902389

RESUMO

We propose a novel approach for the theoretical analysis of the photoinduced high-resolution K(h)α(1,2) x-ray hypersatellite spectra, which allows us to obtain reliable values of lifetimes of the doubly K-shell ionized states and fundamental information about the relative role of K-shell double photoionization (DPI) mechanisms. It is demonstrated for the first time that the K(h)α(1,2) hypersatellite natural line broadening observed for selected metal atoms with 20 ≤ Z ≤ 30 can be well reproduced quantitatively by taking into account the influences of the open-shell valence configuration (adopted from predictions of the band-structure method) and the outer-shell ionization and excitation following the DPI process.

8.
Rev Sci Instrum ; 81(10): 10E312, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034011

RESUMO

Soft x-ray emission from a Mather-type plasma-focus device (PF-1000) operated at ∼400 kJ was measured. The high density and temperature plasma were generated by the discharge in the deuterium-argon gas mixture in the modified (high-current) plasma-focus configuration. A spherically bent mica crystal spectrograph viewing the axial output of the pinch region was used to measure the x-ray spectra. Spatially resolved spectra including the characteristic x-ray lines of highly ionized Ar and continua were recorded by means of an x-ray film. The x-ray emission of PF-1000 device was studied at different areas of the pinch.

9.
Rev Sci Instrum ; 81(10): 10E315, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21061491

RESUMO

The ITER-oriented JET research program brings new requirements for the low-Z impurity monitoring, in particular for the Be­the future main wall component of JET and ITER. Monitoring based on Bragg spectroscopy requires an absolute sensitivity calibration, which is challenging for large tokamaks. This paper describes both "component-by-component" and "continua" calibration methods used for the Be IV channel (75.9 Å) of the Bragg rotor spectrometer deployed on JET. The calibration techniques presented here rely on multiorder reflectivity calculations and measurements of continuum radiation emitted from helium plasmas. These offer excellent conditions for the absolute photon flux calibration due to their low level of impurities. It was found that the component-by-component method gives results that are four times higher than those obtained by means of the continua method. A better understanding of this discrepancy requires further investigations.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...