Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Orofac Orthop ; 84(5): 321-339, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35254453

RESUMO

PURPOSE: Masticatory muscles are physically affected by several skeletal features. The muscle performance depends on muscle size, intrinsic strength, fiber direction, moment arm, and neuromuscular control. To date, for the masticatory apparatus, only a two-dimensional cephalometric method for assessing the mechanical advantage, which is a measure for the ratio of the output force to the input force in a system, is available. This study determined the reliability and errors of a three-dimensional (3D) mechanical advantage calculation for the masticatory system. METHODS: Using cone-beam computed tomography images from teenage patients undergoing orthodontic treatments, 36 craniofacial landmarks were identified, and the moment arms for seven muscles and their load moment arms (biomechanical variables) were determined. The 3D mechanical advantage for each muscle was calculated. This procedure was repeated by three examiners. Reliability was verified using the intraclass correlation coefficient (ICC) and the errors by calculating the absolute differences, variance estimator and coefficient of variation (CV). RESULTS: Landmark coordinates demonstrated excellent intra- and interexaminer reliability (ICC 0.998-1.000; p < 0.0001). Intraexaminer data showed errors < 1.5 mm. Unsatisfactory interexaminer errors ranged from 1.51-5.83 mm. All biomechanical variables presented excellent intraexaminer reliability (ICC 0.919-1.000, p < 0.0001; CV < 7%). Interexaminer results were almost excellent, but with lower values (ICC 0.750-1.000, p < 0.0001; CV < 10%). However, the muscle moment arm and 3D mechanical advantage of the lateral pterygoid muscles had ICCs < 0.500 (p < 0.05) and CV < 30%. Intra- and interexaminer errors were ≤ 0.01 and ≤ 0.05, respectively. CONCLUSIONS: Both landmarks and biomechanical variables showed high reliability and acceptable errors. The proposed method is viable for the 3D mechanical advantage measure.


Assuntos
Imageamento Tridimensional , Mandíbula , Adolescente , Humanos , Reprodutibilidade dos Testes , Mandíbula/diagnóstico por imagem , Variações Dependentes do Observador , Tomografia Computadorizada de Feixe Cônico
2.
Case Rep Dent ; 2015: 452765, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26568893

RESUMO

Rehabilitation of patients with anterior conoid teeth may present a challenge for the clinician, especially when trying to mimic the nature with composite resins. This clinical report exemplifies how a patient with conoid upper lateral incisors was rehabilitated with minimally invasive adhesive restorations. Following diagnostic wax-up and cosmetic mock-up, no-prep veneers and ceramic fragments (partial veneers) were constructed with feldspathic porcelain. This restorative material presents excellent reproduction of the optical properties of the dental structure, especially at minimal thicknesses. In this paper, the details about the treatment are described. A very pleasing outcome was achieved, confirming that minimally invasive adhesive restorations are an excellent option for situations in which the dental elements are healthy, and can be modified exclusively by adding material and the patient does not want to suffer any wear on the teeth.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...